Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Similar documents
DOCUMENTATION IPS640

DOCUMENTATION IPS640

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Security Technology KNX-Intrusion Alarm System L240 Installation, Commissioning, Operation

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

ABB STOTZ-KONTAKT GmbH Webinar ABB i-bus KNX Security Module SCM/S

User Manual. Security Systems Security System L208

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

561-MB256 plus. Intruder alarm control panel. Performance features

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Multi-Gas-Controller MGC2

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Remote alarm indicator and test combination MK2430

Process Alarm Module RTA 421

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

User manual. KNXpar. version

Rules for Intruder Alarm Systems

Fire control panel detect 3004 plus and accessories

Audible warning devices for external alarm

IQ8Control C Fire Alarm Panel

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

UP 258E11 OPTISENS OFFICE

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

APPLICATION DATA SHEET

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Annunciator Unit SACO 16 D1. Product Guide

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

SUPREMATouch. Modular Fire & Gas Detection System

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

APPLICATION DATA SHEET

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Annunciator unit. Application

General Routing Interface

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

SUPREMATouch. Modular Fire & Gas Detection System

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Parameterisable compact fault annunciator with permanent display

Instruction Manual December 2001 ENACOCU02

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Engineering Guideline. pac- Carriers Type Universal

Alarm Switchgear AS1-M

Danfoss gas detection Controller unit

ClimaSys Resistance heaters Selection guide

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

ASD 535 Aspirating smoke detector

Operation and Installation Instruction

CU-02 with Senaco Plus

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

And now: sit back and enjoy the presentation! elearning, ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Room Master

Operating instructions

Instrumentation Products and Applications

COMPACT FLAME CONTROLLER CFC 2000

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

On the job around the clock 24/7: Fire detection systems

Installation / Monitoring Technique

No. Icon Name Function

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

IntesisBox BACnet/IP Server - Notifier ID3000 series

PBI Manual. Paradox to KNX-BUS Interface

Operating Manual MS220KA and MSR220KA

Gas Controller Module GC-06

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

561-MB48. Intruder Alarm Control Panel

COMPACT FLAME CONTROLLER CFC 1000

Dynamic Escape Routing system. D.E.R. system. Sicherheitstechnik GmbH

Product and Applications Description

Interface and EOL Modules 8

BC3250. Blowdown Controller

for relative humidity and temperature

Sensor Interface Module Installation/Operation Instructions

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Added password for IP setup page : Password must be in IP format!

Burner control unit BCU 370

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Combi B Alarm box. Mounting instructions

Fire control panels FC360

Excel-EN Conventional Fire Control Panel

for relative humidity and temperature

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Version 4 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A

Installation Instruction. Fire Alarm Control Panel Compact GB0

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

PRELIMINARY EDITION

Burner control unit BCU 370

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Panel Mounted Fault Annunciator Series

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Transcription:

2 Device technology XS/S 1.1 2CDC 071 115 F0008 The Interface XS/S 1.1 integrates the Intrusion Alarm Panel L240 into the KNX intelligent installation system. It is connected to the XIB bus of the Intrusion Alarm Panel. The state of all 80 zones of the Intrusion Alarm Panel can be transferred on the KNX. Further states of the Intrusion Alarm Panel are transferred on the KNX, e.g. the setting state, the alarm state and the signalling device states. Each of the 80 zones can also be contacted via the KNX. The setting can also be undertaken via the KNX, and the alarm system can be reset via the KNX. Every function, which allows access to the intrusion alarm system via the KNX, can be individually inhibited on the Intrusion Alarm Panel. 2.1 Technical data Supply Operating voltage Implemented via the bus KNX: 21 30 V DC XIB: 12 V DC (rated voltage) Voltage range: 10.5 15 V DC Current consumption KNX Current consumption XIB 5 ma Maximum 40 ma, current consumption of the device Outputs Voltage output 12 V Supplied by the XIB 12 V DC supply Maximum current consumption: 500 ma. Short-circuit protection, protected by a selfrestoring fuse in the device. Connections KNX bus connection terminal, red/black Voltage output 12 V DC XIB (incl. voltage input 12 V DC) Connection terminal, yellow/white Screw terminal on upper side of device Operating and display elements LED red and button For assignment of the physical address LED green LED green LED yellow On = XIB voltage (12 V) available Off = XIB voltage (12 V) fault Indicates whether the communication to the Intrusion Alarm Panel functions via the XIB bus. On = communication OK Off = communication fault LED is switched on with a connection between the XIB and KNX. Flickers with data traffic. Enclosure IP 20 To EN 60529 Safety class III To EN 61140 Environmental class II To VdS 2110 Isolation category Overvoltage category Pollution degree III to EN 60 664-1 2 to EN 60664-1 2009 ABB STOTZ-KONTAKT GmbH 5

Commissioning KNX safety extra low voltage SELV 24 V DC Temperature range Operation -5 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 93 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, ProM Dimensions 90 x 36 x 64 mm (H x W x D) Mounting width Mounting depth 2 modules at 18 mm 68 mm Installation On 35 mm mounting rail To EN 60 715 Mounting position Weight Housing, colour as required 0.077 kg Plastic housing, grey Approvals KNX to EN 50 090-1, -2 VdS (only for non-reacting operation) VdS class C approved (only in conjunction with Intrusion Alarm Panel L240) CE mark In accordance with the EMC guideline and low voltage guideline Application program Number of communication objects Maximum number of group addresses Maximum number of associations Interface L240/1.0 179 254 255 Note The programming requires the software tool ETS2 V1.2 or higher. If ETS3 is used, a *.VD3 or higher type file must be imported. The application program is available in the ETS3 at ABB/Security and Surveillance/Interfaces. The device does not support the closing function of a project or the KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code (ETS3), it has no effect on this device. Data can still be read and programmed. Note The Intrusion Alarm Panel L240 requires a firmware version V4.40 (or higher) to ensure that Interface XS/S 1.1 can be operated. The firmware version is indicated on the Keypad L840/PT as soon as the voltage supply is applied on the alarm panel. 2009 ABB STOTZ-KONTAKT GmbH 6

2.2 Circuit diagram 2CDC 072 184 F0007 (1) Input XIB Terminals A, B for data communication and +, - for device power supply. (2) LED green 12 V OK On = XIB voltage (12 V) available Off = XIB voltage (12 V) fault (3) LED green XIB OK Indicates whether the communication to the Intrusion Alarm Panel functions via the XIB bus. On = communication OK Off = communication fault (4) LED yellow Data LED is switched on with a connection between the XIB and KNX. Flickers with data traffic. (5) 12 V out 12 V DC voltage supply, maximum 500 ma Is taken from the XIB 12 V DC supply: yellow = +, white = - (6) KNX Bus connection terminal (7) Button and LED Button and LED for programming of the physical address in the KNX system (8) Label carrier Important The 12 V DC output (5) may not be connected should the interface be used in a VdS approved system. 2009 ABB STOTZ-KONTAKT GmbH 7

Commissioning 2.3 Dimension drawing 2CDC 072 185 F0007 2009 ABB STOTZ-KONTAKT GmbH 8

2.4 Assembly and installation The device is installed in the enclosure of the Intrusion Alarm Panel L240. The required DIN mounting rail is included in the Intrusion Alarm Panel. Alternatively, installation in a distribution board is possible provided that no VdS compliant requirements are to be fulfilled. The mounting position can be selected as required. Accessibility to the device for the purpose of operation, testing, visual inspection, maintenance and repair must be provided compliant to DIN VDE 0100-520. Commissioning requirements In order to commission the device, a PC with ETS from ETS2 V1.2 or higher as well as an interface to the ABB i-bus, e.g. via a KNX interface, as well as an Intrusion Alarm Panel L240 (including battery and a keypad L840/PT) is required. The installation and commissioning may only be carried out by qualified electrical specialists. The appropriate norms, guidelines, regulations and specifications should be observed when planning and setting up electrical installations. Protect the device from damp, dirt and damage during transport, storage and operation. Only operate the device within the specified technical data limits! The device should only be operated in an enclosed housing (distribution board)! Supplied state The application program is preloaded in the factory. In order to carry out a complete reprogramming of the device it should be unloaded using the ETS beforehand. The device is assigned with the physical address 15.15.255 in the factory. Assignment of the physical address The assignment of the address of the ABB i-bus Interface XS/S 1.1 is carried out via the ETS and the programming button on the device. Cleaning If devices become dirty, they can be cleaned using a dry cloth. Should a dry cloth not remove the dirt, the device can be cleaned using a slightly damp cloth and soap solution. Corrosive agents or solutions should never be used. Maintenance The device is maintenance-free. No repairs should be carried out by unauthorised personnel if damage occurs, e.g. during transport and/or storage. The warranty expires if the device is opened. 2009 ABB STOTZ-KONTAKT GmbH 9