MODEL: HY-3E HyPerSteam Atmospheric Convection Steamer

Similar documents
Part Number DOMESTIC. HyPerSteam Atmospheric Convection Steamer BETA 1.0

OPERATOR MANUAL Part Number

important information i keep for operator i important information

OPERATOR MANUAL Part Number

SBF Series ELECTRIC CONNECTIONLESS STEAMER INSTALLATION - OPERATION - MAINTENANCE

OPERATOR MANUAL IMPORTANT INFORMATION KEEP FOR OPERATOR IMPORTANT INFORMATION. Model: HY-6G HyPerSteam Atmospheric Convection Steamer

MODEL HY-6CAV DOMESTIC HYPLUS ATMOSPHERIC STEAMER CAVITIES

OPERATOR MANUAL. Applicable Model(s): HY-6SM HY-6SG HY-6SE. HyPlus Atmospheric Steamer CAVITIES

Part Number Rev. A DOMESTIC

OPERATOR MANUAL IMPORTANT INFORMATION KEEP FOR OPERATOR IMPORTANT INFORMATION

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UN DERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.

OPERATOR MANUAL IMPORTANT INFORMATION KEEP FOR OPERATOR IMPORTANT INFORMATION

Vortex Atmospheric Connectionless Steamer

FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

MODELS SSB-3E/5E/10E & (2)SSB-3E/5E/10E Domestic SMARTSTEAM100 BOILERLESS STEAMER

MODELS VRC-3E & VRC-6E Domestic VORTEX100 CONNECTIONLESS STEAMER

HY-3E, (2)HY-3E, HY-5E & (2)HY-5E HYPERSTEAM ATMOSPHERIC CONVECTION STEAMER

G-SB Series GAS BOILER BASE STEAMER INSTALLATION - OPERATION - MAINTENANCE BLODGETT OVEN COMPANY.

important information i keep for operator i important information

CART & TROUGH ASSEMBLY for BRAISING PAN UNITS

OPERATOR AND SERVICE MANUAL

IMPORTANT INFORMATION KEEP FOR OPERATOR IMPORTANT INFORMATION. Steam Jacketed Kettle

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

OPERATOR MANUAL IMPORTANT INFORMATION IMPORTANT INFORMATION. Steam Jacketed Kettle

OPERATOR AND SERVICE MANUAL

Installation, Operation, Maintenance, & Troubleshooting Model: EQS-AP Quarter Size Convection Oven

Installation, Operation, Maintenance, & Troubleshooting Model: CLG-36-S Electric Cruise Line Griddle Serial:

OPERATOR MANUAL. Steam Jacketed Kettle. Self-Contained Electrically heated Floor mounted Tilting

Installation. Operation. Maintenance LA 36 Deck Oven

MODEL HY-5G & (2)HY-5G HYPERSTEAM ATMOSPHERIC CONVECTION STEAMER

OM-FT DOMESTIC Part Number

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

MODELS NHFP & NHFP(E) BRAISING PANS

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

TM... TECHNICAL MANUAL. Fryer, Deep-Fat, Electric w/solid State Controls NSN:

HA SERIES. CVap Holding Cabinet Owner s Manual

TDB/6 Domestic STEAM JACKETED KETTLE

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

MODEL TA/3 INCLINED MIXER ASSEMBLY Domestic

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Steam Humidifier Fan Pack Installation & Maintenance Instructions

OPERATIONS MAINTENANCE MANUAL

Water Boilers ME10EN, ME15EN. Table of Contents

KPS-E, KLS-E AND KLT-E SERIES

Operation Maintenance. Mobile Oil Caddy

Water Jacketed Fudge Kettle

Installation & Operating Guide

OPERATING MANUAL/ INSTALLATION

Manual Parts Washer. Operating Instructions & Warranty Information

MODEL DEE/4 Domestic STEAM JACKETED KETTLE

Statement of Responsibilities

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

Wax Base Heater & Dispenser

Xaact Spot. Xaact Hot Spot

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

HEATED DISPLAY CABINET

Viking Installation Guide

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

B.I.C.A Built-In Coffee Appliance

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

Part No Revised November / Instruction Manual Model #8150 AND #8151

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

AHPO-6/18 GOLD PROOFER OVEN

INSTRUCTIONS FOR OPERATION AND CARE OF

INSTALLATION GUIDE Dual Fuel Ranges

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

INSTALLATION AND OPERATION INSTRUCTIONS LC-D SERIES COFFEE CONCENTRATE BREWER WITH DIGITAL ELECTRONIC CONTROL CENTER

Installation & Operating Guide

Model: TDH/C Steam Jacketed Kettle

WARMING AND MERCHANDISING CABINET

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

Operation Manual and Parts Directory

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

e Bath Fan with Light User s Guide

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Carbon Dioxide Sample-Draw Detector Operator s Manual

Professional Warming Drawer and Warming Drawer Cabinet

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

INSTALLATION & OPERATION MANUAL

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Instruction Manual. Cheese Warmer with Pump

Instruction Manual. Double Candy Apple Cooker

User Manual / Installation Instructions

MH70230AS MH70236AS MH70248AS

MODELS SSB-3E/5E/10EF, (2)SSB-3E/5E/10EF, SSB-3G/5G/10GF, (2)SSB-3G/5G/10GF

Transcription:

? IMPORTANT INFORMATION? KEEP FOR OPERATOR? IMPORTANT INFORMATION? OPERATOR MANUAL OM-HY-E Part Number 121004 DOMESTIC MODEL: HY-E HyPerSteam Atmospheric Convection Steamer Self-Contained Electric Heated Capacity: Steamer Pans (12" x 20" x 2½ ) THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.

OM-HY-E IMPORTANT READ FIRST IMPORTANT CAUTION: CAUTION: CAUTION: CAUTION: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT. DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE RIGHT SIDE VENTS, OR WITHIN 12 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER OR KETTLE. LEVEL THE UNIT FRONT TO BACK, OR PITCH IT SLIGHTLY TO THE REAR, TO AVOID DRAINAGE PROBLEMS. TO AVOID DAMAGE OR INJURY, FOLLOW THE WIRING DIAGRAM EXACTLY WHEN CONNECTING A UNIT. DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER. DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN. BLOCKING THE DRAIN IS HAZARDOUS. IMPORTANT: Improper drain connection will void warranty. IMPORTANT: Do not allow any water traps in the line. A trap can cause pressure to build up inside the cavity during steaming, which will make the door gasket leak. NOTICE: NOTICE: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. STEAM CAN CAUSE BURNS. BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT. ALLOW COOKING CHAMBER TO COOL BEFORE CLEANING. CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT. USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY DELIMING AGENT MANUFACTURER. DO NOT MIX DE-LIMING AGENTS (ACID) AND DE-GREASERS (ALKALI). DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS STOPPED TURNING. DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANEL HAS BEEN RETURNED TO ITS PROPER LOCATION. DO NOT USE A CLEANING OR DE-LIMING AGENT THAT CONTAINS ANY SULFAMIC ACID OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT OF ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER. DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE OR THAT IS ALKALINE. USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES. HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH. 2

Table of Contents OM-HY-E OPERATOR WARNINGS... 2 REFERENCES... EQUIPMENT DESCRIPTION... 4 INSPECTION AND UNPACKING... 4 WATER CONDITIONING/REQUIREMENTS... 4 INSTALLATION AND START-UP INSTRUCTIONS... 5 OPERATING INSTRUCTIONS... 8 CLEANING AND MAINTENANCE PROCEDURES CLEANING... 9 MAINTENANCE AND TROUBLESHOOTING... 11 PARTS LIST... 12 SCHEMATICS... 15 SERVICE LOG... 17 WARRANTY PROTECTION... 19 References UNDERWRITERS LABORATORIES, INC. NATIONAL FIRE PROTECTION Pfingsten Road ASSOCIATION Northbrook, Illinois 60062 60 Battery March Park Quincy, Massachusetts 02269 KLENZADE SALES CENTER NFPA/70 The National Electrical Code ECOLAB, Inc. 70 Wabasha NATIONAL SANITATION FOUNDATION St. Paul, Minnesota 55102 475 Plymouth Road 800 28-66 or 612 29-22 Ann Arbor, Michigan 48106

OM-HY-E Equipment Description Your Groen HY-E HyPerSteam Convection Steamer is designed to give years of service. It has a stainless steel cavity (cooking chamber) which is served by an independent atmospheric steam generator which is electrically-heated. A powerful blower circulates the steam In the cavity to increase heating efficiency. The cavity holds up to three steam table pans (12" x 20" x 2½"). A 16 gauge stainless steel case encloses the cavity, the steam generator and the control compartment that houses electrical components. Door hinges are reversible (the door may be set to open from the left or right). Operating Controls are on the front panel. The drain system includes a spray condenser, which helps keep steam from escaping from the chamber. Inspection and Unpacking The HY-E will be delivered completely assembled in a heavy shipping carton attached to a skid. On receipt, inspect the carton carefully for exterior damage. CAUTION SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT. Carefully cut the straps around the carton and detach the sides of the carton from the skid. Pull the carton up off the unit. Be careful to avoid personal injury or equipment damage from staples which might be left in the carton walls. The HY-E steamer holds three standard 12"x 20"x 2-½" pans. Write down the model number, serial number and installation date and keep this information for future reference. Space for these entries is provided at the top of the Service Log in the back of this manual. CAUTION THIS UNIT WEIGHS 180 POUNDS (82 KG). YOU SHOULD GET HELP AS NEEDED TO LIFT THIS WEIGHT SAFELY. When starting installation, lift the unit straight up off the skid. Check packing materials to make sure loose parts are not discarded with the material. Water Conditioning It is essential to supply the steam generator with water that will not form scale. Even though the steam generator is engineered to minimize scale formation, scale development depends on the hardness of your water and the number of hours you operate the equipment. In some areas, water is low enough in mineral content to avoid scale formation. But most water supplies are full of minerals which form scale. It is this scale which could lead to an early component failure. Your water utility can tell you about the minerals in your water. The water going to the steam generator should have between 10 and 0 parts per million (ppm) total dissolved solids (TDS) and should have a ph (acidity rating) of 7.0 or higher. Please follow these simple precautions: 1. Do not rely on unproven water treatments which are sold for scale prevention or scale removal. They don t always work. The best way to prevent scale is to supply the purest possible water (10-20 ppm TDS). 2. If your water contains scale-forming minerals, as most water does, use a well-maintained water softener. Whether an exchangeable softener cartridge or a regenerating system is chosen, a regular exchange schedule is essential.. Installing a water meter between the softener and the steamer will provide an accurate gauge of water use, and will help determine when to exchange cartridges or regenerate the softener. 4

Using a water softener will provide longer generator life, higher steam capacity, and reduce maintenance requirements. OM-HY-E 4. If you notice a slowdown in steam production, have the unit checked for scale build-up. Heavy scale reduces the unit s ability to boil water, and can even cause heating elements in the steam generator to overheat and burn out. MINIMIZE SCALE PROBLEMS, BY USING AND MAINTAINING A SOFTENER, AND BY CLEANING THE STEAMER REGULARLY. Groen Steamers are also available with an option for two separate water intakes one for the steam generator (soft water), the other for the spray condenser (untreated water). The steam generator only uses 14 to 1% of a steamer s water. The optional second water connection can reduce treated water requirements. Installation and Start-Up Since softener systems are typically sized by total GPH (gallons per hour), the second intake could reduce treatment requirements by up to 80%, resulting in significant savings. On the HY-E, the twin water connections are side by side on the rear of the unit. When facing the back of the unit, the treated (softened) water intake is on the right. WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. CAUTION DO NOT INSTALL THE UNIT WITH THE RIGHT SIDE VENTS BLOCKED OR WITHIN 12 INCHES OF A HEAT SOURCE (SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER OR KETTLE). TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK. 1. Electrical Supply Connection A. Panel Removal Open the wiring and control panel by removing two screws on the right side panel. Slide the panel forward, and set it aside. B. Supply Voltage The unit must be operated at the rated nameplate voltage, plus or minus 10 percent. C. Phase Selection Refer to the heater schematic (Pages 15 and 16) for wiring information. CAUTION THE UNIT MUST HAVE A SEPARATE GROUND WIRE FOR SAFE OPERATION. D. Terminal Block The terminal block for incoming power is located at the back of the control compartment. 5

OM-HY-E The ground terminal is located in the wiring compartment above the terminal block. Minimum size for the ground wire is 10 AWG. E. Supply wire To determine the type of wire you need for the power supply, find the operating voltage and phase on the unit data plate. Refer to the table provided on the next page or to the label on the unit s back for the correct wire size and insulation temperature rating. The Electrical Supply Connection label on back right side of the unit gives directions for proper connection of the terminal block jumpers. The wire specified has to be used, or the unit will not meet Underwriters Laboratories and National Electric Code requirements. The knockout hole is sized for a /4 inch conduit fitting. WARNING TO AVOID DAMAGE OR PERSONAL INJURY, FOLLOW THE ELECTRICAL SCHEMATIC EXACTLY WHEN CONNECTING THE UNIT ELECTRICAL SUPPLY CONNECTIONS FIELD WIRING TABLE - USE ONLY COPPER WIRE 208 VOLT 240 VOLT 480 VOLT INSULATION RATING 1 PHASE PHASE 1 PHASE PHASE PHASE o 6 AWG 10AWG 8 AWG 10 AWG 14 AWG THWN (70 C) 8 AWG 10 AWG 8 AWG 10 AWG 14 AWG THWN (90 o C F. Branch Circuit Protection If you have the twin water connection option, put the treated water (softened) to the right intake We strongly recommend that the HY-E Steamer have its own branch circuit protection. Current and power demands for the different units are as follows: (facing the rear of the unit), and untreated water to the left. Connections for both are made as described above.. Drain Connection VOLTAGE PHASE AMPS MAX. KW 208 1 9 8 2 8 240 1 8 20 8 480 10 8 The HY-E Steamer must be leveled front to back, or even pitched slightly to the rear by adjustment of the bulllet feet on the cabinet base. A 1½ inch (8mm) ID hose may be attached to the drain pipe (supplied). 2. Water Connection(s) Install a check valve to prevent back flow in the incoming cold water line, as required by local plumbing codes. Water pressure in the line should be between 0 and 60 PSIG (210 and 420 kpa). If pressure is above 60 PSIG, a pressure regulator will be needed. A ¾ inch R connector (garden hose type) is used to attach the water supply to the water inlet valve. The minimum water feed line diameter is ½ inch (1mm). Use a washer in the hose connection. Do not allow the connection to leak, no matter how slowly. DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN. There must be at least one-half inch free air gap between the end of the hose and the building drain. The free air gap should be as close as possible to the unit drain. There must also be no other elbows or other restrictions between the unit drain and the two inch free air gap. CAUTION DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER. 6

WARNING BLOCKING THE DRAIN IS HAZARDOUS. Install the drain line with a constant downward pitch. OM-HY-E IMPORTANT: Do not allow any water traps in the line. A trap can cause pressure to build up inside the cavity during steaming, which will make the door gasket leak. DRAIN LINE INSTALLATION (WITH DRAIN BOX) OPTION ONE: To go from Stainless Steel Elbow (P/N 092272) to nearby floor drain, you can use Radiator Hose (McMastero Carr #5297K24 - at least a 212 F rated hose), and one additional hose clamp (P/N 07259). OPTION TWO: Using the hose (P/N 07254) and two hose clamps (P/N 07259), you can connect 1½ copper tubing to the floor drain. NOTE: All drain line runs must be pitched downward approximately ½ per foot. No water traps are allowed in the drain line. (WITHOUT DRAIN BOX) From the Muller Brass coupling-reducer (P/N W-1095), you can connect 1½ copper tubing to the floor drain. 7

OM-HY-E Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. A. Controls Operator controls are on the front right of the unit. The ON switch gets the HyPerSteam ready for use, or shuts it off. The READY indicator light shows that the steam generator is at standby temperature, which means that the cavity is hot enough to begin cooking. The timer is used in three ways: In the OFF position the steam generator stays at a very low boil or holding temperature. When a cook time is set, the unit steams until the timer runs down to OFF. At that time steaming stops, a red light comes on and a beeper sounds. When turned all the way to the ON position, the unit steams continuously. The green light stays lit, and the steamer will not time down. B. Operating Procedure WARNING WHEN YOU OPEN THE DOOR, STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS. If you want to steam continuously, turn the timer to the manual ON position. A green light will come on. The unit will continue steaming until you stop it by turning the timer to OFF. When steaming continuously YOU MUST CONTROL STEAMING TIME. 5. Open the door. Remove the pans from the steamer, using hot pads or oven mitts to protect your hands from the hot pans. 6. To shut down the unit, press the ON switch to the OFF position. The steam generator will automatically drain. 1. Press the ON switch for the steamer. The steam generator will automatically fill with water, and heat the water until the READY light comes on. The indicator should light within 10 minutes. 2. Load food into pans so that it is in uniform layers. Pans should be filled to about the same levels, and should be even on top.. Open the door and slide the pans onto the supports. If you will only be steaming one pan, put it in the middle position. 4. Close the door. With the READY indicator lit, take one of the following steps: If you want to steam the food for a certain length of time, set the timer to that time. The timer will automatically run the steamer for the set time and then turn it off. A red light will come on and a beeper will sound. Steam stops. 8 Controls for the HY-E are simple, and easy to operate.

Cleaning OM-HY-E To keep your HY-E Steamer in proper working condition, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generator and cavity. A. Suggested Tools 1. Mild detergent 2. Stainless steel exterior cleaner such as Zepper. Steam generator de-liming agent, such as Groen Delimer Descaler, Lime-Away or an equivalent. A liquid de-liming agent will be easier to use than crystals or powders. See the warning about chlorides, below 4. De-greaser, such as EncompasS, Malone 4, Puritan Puribrute, or Con-Lie 5. Cloth or sponge 6. Plastic wool or a brush with soft bristles 7. Spray bottle 8. Measuring cup 9. Nylon pad 10. Towels 11. Plastic disposable gloves 12. Funnel B. Procedure 1. Exterior Cleaning a. Prepare a warm solution of the mild detergent as instructed by the supplier. Wet a cloth with this solution and wring it out. Use the moist cloth to clean the outside of the unit. Do not allow freely running liquid to touch the controls, the control panel, any electrical part, or any open louver. b. To remove material which may be stuck to the unit, use plastic wool, a fiber brush, or a plastic or rubber scraper with a detergent solution. c. Stainless steel surfaces may be polished with a recognized stainless steel cleaner such as Zepper. PRECAUTIONS WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE STEAMER. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT. DON T MIX DE-LIMING AGENTS (ACID) WITH DE-GREASERS (ALKALI) ANYWHERE IN THE UNIT AVOID CONTACT WITH ANY CLEANERS, DE-LIMING AGENT OR DE-GREASER AS RECOMMENDED BY THE SUPPLIER. MANY ARE HARMFUL. READ THE WARNINGS AND FOLLOW THE DIRECTIONS! EVEN WHEN THE UNIT HAS BEEN SHUT OFF, DON T PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS STOPPED TURNING. DON T OPERATE THE UNIT UNLESS THE TWO REMOVABLE INTERIOR PARTITIONS HAVE BEEN PUT BACK IN THEIR PROPER LOCATIONS. DON T USE ANY CLEANING OR DE- LIMING AGENT THAT CONTAINS ANY SULFAMIC AGENT OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID (HCl). TO CHECK FOR CHLORIDE CONTENT SEE ANY MATERIAL SAFETY DATA SHEETS PROVIDED BY THE CLEANING AGENT MANUFACTURER. IMPORTANT DO NOT USE ANY METAL MATERIAL (SUCH AS METAL SPONGES) OR METAL IMPLEMENTS (SUCH AS A SPOON, SCRAPER OR WIRE BRUSH) THAT MIGHT SCRATCH THE SURFACE. SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW. DO NOT USE STEEL WOOL, WHICH MAY LEAVE PARTICLES IMBEDDED IN THE SURFACE WHICH COULD EVENTUALLY CAUSE CORROSION AND PITTING. 9

OM-HY-E Steam Generator and Cooking Chamber The steamer cavity and steam generator may be cleaned separately. When cleaning is scheduled, or if the CLEAN light is on, follow these simple deliming instructions. REMEMBER: DON T ALLOW DE-LIMING AGENTS TO MIX WITH DE- GREASERS. a. Set the timer to OFF position. b. Turn off the steamer for five minutes. c. Open the door and allow the cavity to cool. d. After the cavity has cooled five minutes, make sure that the fan has stopped and remove the fan baffle partition by lifting it up and toward the center of the cavity. e. Wipe out the cavity. Make sure the drain holes at the back of the cavity are clear of debris. f. Turn on the steamer and pour two cups of Groen Delimer Descaler (P/N 114800), Lime- A-Way or equivalent into the delimer port as shown below. (use a measuring cup or funnel to help prevent spilling). Do not use any de-limer that contains chlorine. g. Replace fan baffle partition. h. Close door. i. Set the timer for 10 minutes. If the CLEAN light comes on, repeat the procedure with double the amount of delimer. If the CLEAN light comes on again, call the authorized Groen Service agent in your area. (See listing enclosed with this manual).. j. WEAR PROTECTIVE GLOVES AND EYE PROTECTION FOR THIS STEP. When the steamer beeper sounds, turn off the steamer and open the door. After the fan has stopped, remove the fan baffle partition and rinse it well in a sink. Wipe out the cavity completely. If necessary, use a damp nylon pad. k. Reinstall the fan baffle. l. After 10 minutes, close the door and turn on the steamer to flush the steam generator tank. m. Set the time for 10 minutes. n. When the beeper sounds, open the door and turn off the steamer. Wipe out the steamer. If it will no longer be used, leave it off. Otherwise, wait 10 minutes and turn it back on. When the READY light comes on, the steamer is ready for operation. If the CLEAN light stays on: a. Check that the water supply is on and that the supply hose is not kinked. With the problem corrected, turn the steamer off or 10 seconds and then re-start. b. Repeat steam generator cleaning. Industry experts agree that regular deliming of your steamer is essential for top-notch performance....forensic evidence from most disabled steamers usually indicates that deliming isn t happening as frequently as supervisors might think. The big problem is that operators don t take care of their steamers, said (a) dealer sales manager... All steamers break when they re not delimed, he said. Deliming is just like changing the oil in your car. No matter how good your car is, if you don t change the oil, it goes down. You must delime your steamer...and when you do delime, do it according to directions in the owner s manual....for Groen, you have to take out the racks and get inside, but the process again is simple, tool-less and quick, about 25 minutes......food Service Equipment ReportsK Vol. 1, m9 The process for deliming your HY-E Steamer is simple, tool-less and quick. 10

Maintenance OM-HY-E The HY-E Steamer is designed for minimum 2. Inspect the cooking chamber drain to be sure it maintenance, and no user adjustments should be is not blocked. necessary. Certain parts may need replacement after prolonged use. If there is a need for service, only Groen personnel or authorized Groen representatives should perform the work.. Adjust the latch pin to allow for changes that might occur as the gasket ages. Always supply water with a low mineral count that meets the standards outlined in the Water Conditioning section of this manual. The unit contains no fuses that should be replaced by the operator If steam or condensate is seen leaking from around the door, take the following steps: 1. Check the door gasket. Replace it if it is cracked or split. a. Loosen the lock nut at the base of the latch pin, then turn the latch pin ¼ turn clockwise, and tighten the lock nut. b. After adjustment, run the unit to test for further steam leakage. c. If there is still leakage, repeat the adjustment. d. Continue adjusting the pin clockwise until the door fits tightly enough to prevent leakage. Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the check list is marked with (Y), it means that the work should be done by a factoryauthorized service representative. SYMPTOM WHO WHAT TO CHECK! Steam generator does not fill User a. Is the ON switch depressed? with water. b. Is the water supply connected? c. Is the water turned on? d. Check for low water pressure (less than 0 PSI or 210 kpa). e. Is the screen at the water connection clogged? f. Has the steam generator been delimed?! No steam. User a. Is the ON switch depressed? b. Is the water supply connected? c. Is the water turned on? d. Are steamer doors open? e. Is the steam generator limed up?! Red light comes on after four User a. Is the water supply connected? minutes. b. Is the water turned on? c. Has the unit been delimed? (Refer to Cleaning Section)! Excessive steam escaping User a. Is the water spray hose kinked or obstructed? from rear of unit Auth Service b. Is the water spray solenoid connected?(y) Rep Only c. Is the drain properly vented? (Y) 11

OM-HY-E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. REAR VIEW Ke Key Description Part No. y Description Part No. 1 Right Side Panel 096796 18 Top Side Cover 096777 2 Door Assembly, Complete 094150 19 Back Panel 096795 Door Handle 07012 20 Water Valve - Two Way 07125 4 Door Gasket 094147 20a Dual Water Valve 108702 5 Left pan Rack 094148 21 Steamer Table - Optional 10091 6 Blower Cover/Rack 096788 22 Drip Tray 094151 7 Door Locking Pin 078914 2 Timer Fastener Nut 101145 8 Door Pin Lock Nut 0082 24 Tinnerman Clip (for Timer Lamps) 096849 9 Green Timer Lamp 096897 25 Diverter and Vent Assembly 088876 10 Red Timer Lamp 096898 % Heat Shield 118127 11 Cavity Fan 096790 % Dual Water Kit 108702 12 Timer 096826 % Optional Legs 041121 1 Time Knob 040225 % Drain Box Flap Kit 10714 14 Red Clean Lamp 096889 % Drain Kit 088879 15 Green Ready Lamp 096890 % Diverter and Vent Kit 088862 16 Cavity Power Switch 088876 % P. C. Board Cover 10099 17 Mylar Overlay Plate 096872 % Supports 099901 % Part Not Shown 12

OM-HY-E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. Key Description Part No. Key Description Part No. 1a Heater Element, 200 Volt 094118 11 Transformer 208/240/480 Volt Pri./ 100912 1b Heater Element, 208 Volt 094129 24 Volt Sec. 75 VA 1c Heater Element, 240 Volt 09410 For 208/240 Volt Units 1d Heater Element, 480 Volt 09412 12 High Heat Contactor 096729 2 Heater Element Gasket 04266 For 480 Volt Units High Limit Thermostat 094161 12b Low Heat Contactor 101165 4 Thermostat Clamp 09482 (24 Volt Coil) 5 Water Level Probes 070178 12c High Heat Contactor 101166 6 Water Valve - Two Way 07125 (240 Volt Coil) 7 Water Level Board 096882 1 Toroid Transformer 480 Volt Pri./ 101110 8 Control Board 098666 240 Volt Sec. 115 VA 9 Fuse, Three Amp 07785 14 Fuse Holder* 077854 10 Fuse, 20 Amp 071489 *Part Not Shown in Photograph 1

OM-HY-E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. Key Description Part No. Key Description Part No. 1 Red Timer Lamp 096898 26 Drain Hose,* Steam Generator 096806 2 Green Timer Lamp 096897 27 Spray Nozzle* 0789 Tinnerman Clip 096849 28 Spray Hose* 096807 4 Timer 096826 29 Water Inlet Hose* 09677 5 Red Clean Lamp 096889 0 Motor Capacitor* 09681 6 Green Ready Lamp 096890 1 Drain Hose, Cavity* 11295 7 Cavity Power Switch 09689 2 Ready Thermostat 088865 8 Door Switch 096857 20 AMP Fuses 071489 9 Water Level Board 096882 4 AMP Fuse* 07785 10 Steamer Control Board 098666 5* Timer Fastener Nut* 101145 11 Steam Port 11810 208/240 Volt Units 11a Steam Port Gasket 099250 6 High Heat Contactor 096729 12 Fan Motor 096740 7* Harnesses*-Call Groen Authorized Svc Agent 12a Motor Seal 096868 480 Volt Units 1 Upper Steam Hose 100925 8 Low Heat Contactor (24 Volt Coil) 101165 14 Lower Clean Hose 100926 9 High Heat Contactor(240 Volt Coi)l 101166 15 Hose Clamps 1-/8" 01087 40* Toroid Transformer 115 VA, 480 Volt 101110 16 Electric Heater Gasket 04266 Pri./20 Volt Sec.* 17 Transformer 208/240/480 Volt Pri./ 100912 41* Fuse Holder* 077854 24 Volt Sec. 75 VA 42* Fuse.75 AMP SLO-BLO* 101112 19a Electric Heater, 208 Volt 094129 4* Harnesses*-Call Groen Authorized Svc Agent 19b Electric Heater, 240 Volt 09410 Cavity 096825 19c Electric Heater, 480 Volt 09412 Insulation 09678 19d Electric Heater, 200 Volt 094118 Water Flow Reducer 106445 20 High Limit Thermostat 094161 Water Fill Assembly 100988 21 Steam Generator 09686 Drain Box (old style) 100975 *21a Insulation Steam Generator 100922 Tube 100975 22 Fuse Block 096809 Boiler with Insulation 10092 2 Terminal Block 088214 Safety Valve 01455 24 Inlet Water Valve - Two Way* 07125 Grommet 00492 Brackets 094189 Thermostat (old style) 099947 25 Drain Valve* 07124 Drain Tube Assembly 100989 Brackets 099991 *Part Not Shown in Photograph 14

Electrical Schematics L1 480V XF H1 F LOW 18AWG 600V 105EC H2 24 VAC HIGH H H4 TR1 X2 RED DRAIN VALVE 10 AWG 600V JUMPERS X L2 X L1 X L2 L EXCEPT 480V DO CONNECT POWER TO THESE TERMINALS H1 X1 240V 208V H2 24 VAC H TRANSFORMER TR1 WIRING SCHEME X2 H4 E POWER D SW1 BOILER READY K2 K1 C LO HI DRAIN WATER LEVEL RED CONTROLS CLEAN L1 L2 HTR WF A AM REFER TO SWITCH DIAGRAM K1 K1 K DOOR C1 AC SWITCH K2 M CLEAN FILL VALVE READY FAN RELAY HIGH POWER CONTACTOR TIMER MOTOR TB1 20A F1 L1 X L2 18AWG L 20A F2 GND HEATER HIGH LIMIT 265EF 12 AWG 14 AWG 14 AWG 12 AWG L1 L2 L L4 K4 C1 T1 T2 T4 4 T 1 14AWG 600V 200EC 6 TYP. 2 6 5 18AWG 200EC 2500W 1 6 2 4 2500W 500W 5 8KW CAVITY POWER SWITCH W/ON-OFF LEGEND SHOWN IN OFF POSITION TIMER 12 Off 11 Off 21 K1 22 24 MANUAL TIMING DONE WV4 GR R GR K4 K2 ALL WIRES ARE 22 Ga 150V UNLESS NOTED ALL WIRES TO MOTOR ARE 18 Ga 600V 125EC MIN. WV COND. SPRAY 500 WATT HEATER ON BEEPER DONE READY K CAPACITOR 208/240V= uf 0V 14 1 12 10 9 8 6 5 KEY 2 1 MOTOR 600 RPM M1 CAVITY POWER SWITCH SHOWN IN OFF POSITION E D L Back View A B C OFF CAVITY POWER SWITCH SHOWN IN OFF POSITION ORANGE DOT INDICATOR (C) (B) Back View Back View (D) (E) SWITCH USED AFTER 2/1/95 208 and 240 Volt Models 15 OM-HY-E

Electrical Schematics OM-HY-E 480 Volt Model 16

Electrical Schematics E POWER D SW1 Off 21 18AWG 600V 105EC H H1 H2 H4 TR1 F RED XF 24 VAC X2 BOILER READY K2 K1 TIMER 12 Off 11 K1 22 24 LOW C LO HI DRAIN WATER LEVEL CONTROLS CLEAN L1 L2 HTR WF AM K1 DOOR AC SWITCH TIMING DONE HIGH A MANUAL K2 WV4 GR R GR K1 K C1 M K4 K2 DRAIN VALVE RED WV ALL WIRES ARE 22 Ga 150V UNLESS NOTED ALL WIRES TO MOTOR ARE 18 Ga 600V 125EC MIN. CLEAN FILL VALVE READY FAN RELAY HIGH POWER CONTACTOR TIMER MOTOR COND. SPRAY 500 WATT HEATER ON BEEPER DONE READY TB1 CAVITY POWER SWITCH W/ON-OFF LEGEND SHOWN IN OFF POSITION 20A F1 OFF 18AWG K Back View 20A F2 KEY CAPACITOR 208/240V= uf 0V 14 1 12 10 9 8 6 5 2 1 GND HEATER HIGH LIMIT 265EF CAVITY POWER SWITCH SHOWN IN OFF POSITION ORANGE DOT INDICATOR 12 AWG 14 AWG 14 AWG 12 AWG 14AWG 600V 200EC 6 TYP. MOTOR 600 RPM M1 Back View SWITCH USED AFTER 2/1/95 L1 L2 L L4 K4 C1 T1 T2 4 T 1 T4 CAVITY POWER SWITCH SHOWN IN OFF POSITION 2 5 H1 X1 E D 200V L Back View H2 24 VAC A B C 2500W 1 6 2 4 18AWG 200EC 240V 220V 500W H H4 X2 TRANSFORMER TR1 WIRING SCHEME 80/415 Volt Three Phase and 220/240 Volt One Phase Models (C) (B) (D) (E) 6 2500W 5 8KW DO CONNECT POWER TO THESE TERMINALS L1 L2 L L4 L1 L2 L L4 C1 T2 4 T 1 T4 PHASE 80/415V C1 T1 T2 T T4 T1 4 1 2 6 6 2 6 5 5 10 AWG 600V JUMPERS 2500W 1 6 2 4 1 X X TOP 2500W 10 AWG 600V JUMPERS 2500W TOP L1 N N L1 L2 L 6 5 2 4 2500W 5 OM-HY-E 17

OM-HY-E Service Log Model No. Serial No. Date Purchased Purchase Order No. Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by 18

OM-HY-E LIMITED WARRANTY TO COMMERCIAL PURCHASERS* (Continental U.S., Hawaii and Canadian Sales Only) Groen Foodservice Equipment ( Groen Equipment ) has been skillfully manufactured, carefully inspected, and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for (12) twelve months with the following conditions an subject to the following limitations. I. This parts and labor warranty is limited to Groen Equipment sold to the original commercial purchaser/users (but not original equipment manufacturers {O.E.M.}), at its original place of installation in the continental United States, Hawaii and Canada. II. III. IV. Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is the sole responsibility of the purchaser/user. Groen,, or an authorized service representative, will repair or replace, at Groen s sole election, any Groen equipment, including but not limited to, drawoff valves, safety valves, gas and electric components, found to be defective during the warranty period. As to warranty service in the territory described above, Groen will absorb labor and portal to portal transportation costs (time and mileage) for the first twelve (12) months from date of installation or fifteen (15) months from date of shipment from Groen. This warranty does not cover boiler maintenance, calibration, periodic adjustments as specified in operating instructions or manuals, and consumable parts such as scraper blades, gaskets, packing, etc., or labor costs incurred for removal of adjacent equipment or objects to gain access to Groen Equipment. This warranty does not cover defects caused by improper installation, abuse, careless operation, or improper maintenance of equipment. This warranty does not cover damage caused by poor water quality or improper boiler maintenance. V. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REMEDIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL GROEN BE LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF THIS WARRANTY. VI. Groen Equipment is for commercial use only. If sold as a component of another (O.E.M.) Manufacturer s equipment, or if used as a consumer product, such Equipment is sold AS IS and without any warranty. *(Covers all Foodservice Equipment Ordered after October 1, 1995) 19

1055 Mendell Davis Drive Jackson, MS 9272 Telephone 601 72-90 Fax 601 7-9587 OM-HY-E (Revised 2/98) Part Number 121004