Acoustic Resonance in Nuclear Boiling Water Reactors

Similar documents
Impact of Flow Induced Vibration Acoustic Loads on the Design of the Laguna Verde Unit 2 Steam Dryer

SNAP, CRACKLE, & POP: THE BWR POWER UPRATE EXPERIMENT

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

10 CFR Part 21 Evaluations

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

Fisher DMA, DMA-AF, DMA-AF-HTC, DSA, and DVI Desuperheaters

Appendix B3 System/Component Cause Codes

15900 HVAC INSTRUMENTATION AND CONTROLS

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Nuclear Electric Heating

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

ANNEX V. AP600 & AP1000 Westinghouse Electric, USA

Pressure Vessel Design Guides And Procedures

Pressure Vessel Design Guides And Procedures

Pool boiling heat transfer enhancement on porous surface tube

Secondary Systems: Condensate/Feedwater Cycle

UGU, A VERSATILE EVAPORATOR IN NUCLEAR INDUSTRY. B. G. Christ RWE NUKEM GmbH Alzenau, Germany

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Understanding Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for the Ammonia Industry

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Steam System Best Practices Document No. 11

PDH & Professional Training

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

Effect of Foundation Embedment of PWR Structures in SSI Analysis considering Spatial Incoherence of Ground Motions

Supercritical Carbon Dioxide Brayton Power Cycle Test Loop - Operations Review

TANKLESS WATER HEATING

Music Sculptures of Glass and Gold

HEAT TRANSPORT SHUTDOWN COOLING

Centrifuge modelling and dynamic testing of Municipal Solid Waste (MSW) landfills

Safety Considerations for Hydrogen Installations

CNG. PSB Industries. NG Series -- Natural Gas Dryers

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

Numerical Standards Listing

Di-440 The Modular Analyser

Drying principles and general considerations

OPUCN CUSTOM INCENTIVE RATE PLAN PERFORMANCE REPORT

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

What to Expect from Your EtaPRO Investment

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Finite Element Analysis, Harmonic Analysis and Modal Analysis of the Car Floor by Using With and Without Stiffener

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

Numerical Standards Listing

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Preventing Fires And Explosions In Pilot Plants And Laboratory Units

MINIMUM TANK GAP. Greater of 3 or one-sixth of sum of adjacent tank diameters. one-half of sum of adjacent tank diameters 20

Stock Vessels for Improved Quality and Energy Savings

The Murphy EVS Electronic Vibration Switch. Installation and Operations Manual Section 20

A Study of the Condenser in Nuclear Power Plants

Gas Piping Facts. Information for properly sizing gas lines for use with tankless water heaters and other gas appliances TANKLESS WATER HEATING

Numerical Standards Listing

Fire Protection at Shearon Harris: Other than being unsafe and illegal, no problems at all

Vermont Yankee Nuclear Power Station Decommissioning

AP1000 European 11. Radioactive Waste Management Design Control Document

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

REGULATORY GUIDE OFFICE OF NUCLEAR REGULATORY RESEARCH. REGULATORY GUIDE (Draft was issued as DG-1170, dated November 2006)

Vacuum Insulated Pipe

Yankee Dryer Safety. Program

Fire Risks of Loviisa NPP During Shutdown States

Dr. MOHAMMAD ABDEL-KARIM Associate Professor

Available at: Last Modified: December 2012

NOISE AND VIBRATION STANDARD

The effect of embedment on a foundation subjected to vertical vibration a field study

Steamist Installation Guidelines

Application of Radioactive Particle Tracking (RPT) and Densitometry for Measuring Liquid Velocity Fields and Void Fraction in Convective Boiling Flows

Commissioning of a 1 MWe Supercritical CO 2 Test Loop

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

2017 FSRUG Thermal Performance Feedwater Heater Troubleshooting FSRUG FWH Troubleshooting 1

Copyright 1984 by ASME DESIGN OF A HEAT RECOVERY STEAM GENERATOR

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Well, you have figured out the world's best offshore pipeline leak detection system. Now, how are you going to install it?

Start Up the Evap System

Takashi USUDA, NMIJ. Source: Report of the ISO International Observer to the 7th CCAUV(2010) by Dr. H.-J. von Martens

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Transport research opportunities and needs: What can fibre optics do for us? Stephen James Engineering Photonics

Boiler Venting. Definitions, Theory and Applications. Presented by: Jason Geagan, National Sales Manager US Draft Co Fort Worth, TX

STEAM AND TRAP FUNDAMENTALS

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Defense Nuclear Facilities Safety Board Mission & Operations

Analysis to speed up of the start-up of steam boiler OP-380

DETECTION AND LOCALIZATION OF MICRO-LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

MST sterilizer overview

High Temperature Water Heat Pipes for Kilopower System

INFLUENCE OF DIFFERENT TEMPERING PERIOD AND VACUUM CONDITIONS ON THE RICE GRAIN BREAKAGE IN A THIN LAYER DRYER

American Nuclear Society (ANS)

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Transcription:

Acoustic Resonance in Nuclear Boiling Water Reactors Thomas G. Scarbrough Division of Engineering Office of New Reactors U.S. Nuclear Regulatory Commission Pennsylvania State University Center for Acoustics and Vibration Workshop April 29-30, 2013

Introduction Some nuclear power plants with boiling water reactors (BWRs) have experienced significant acoustic resonance in their reactor and steam systems. In some cases, acoustic resonance has resulted in damage to plant components in reactor pressure vessel (RPV) and steam lines. As a result, nuclear power plant applicants and licensees evaluate potential adverse flow effects during initial plant design and startup of new reactors, and for power uprates of operating reactors. 2

Boiling Water Reactor 3

Boiling Water Reactor Pressure Vessel 4

Acoustic Resonance Turbulent steam flow in RPV can excite large-scale, low-frequency acoustic modes Steam flow over safety valves (SVs), safety relief valves (SRVs), and other branch lines can couple with high-frequency acoustic mode of branch steam column Pressure fluctuations with low and high frequencies in RPV and steam lines can impact steam dryer Acoustic resonance has caused severe vibration of steam line components 5

Strouhal Analysis Strouhal number can be defined as fd/u, where f is frequency at which shear layer oscillates, D is sidebranch opening diameter, and U is steady flow speed of shear layer Strouhal numbers can vary with pipe diameter ratio, distance from upstream elbows, and acoustic damping Strouhal number chart developed by Ziada and Shine to predict critical flow velocity at which acoustic resonances may be initiated 6

Valve Tone Excitation in BWR Steam Lines 7

Singing Safety Relief Valve 8

U.S. BWR Unit 2 Steam Dryer Experience In June 2002, steam dryer cover plate failed after 90 days of power uprate operation (117% original power). In June 2003, steam dryer hood failed after additional 300 days of power uprate operation. In March 2004, steam dryer cracked after additional 8 months of power uprate operation. 9

BWR Unit 2 Steam Dryer Failures (2002 and 2003) 10

U.S. BWR Unit 1 Steam Dryer Experience In November 2003, steam dryer hood failed after 1 year of power uprate operation (117% original power). 6x9 inch plate of steam dryer outer bank lost in reactor coolant and steam system Damage also found to steam line components 11

BWR Unit 1 Steam Dryer Failure (Nov. 2003) 12

Example BWR Steam Dryer Replacement In Spring 2005, BWR Units 1 and 2 steam dryers replaced with improved design Unit 2 steam dryer instrumented with pressure sensors, strain gages, and accelerometers BWR steam lines instrumented with strain gages to calculate pressure load on Unit 1 steam dryer based on Unit 2 benchmark Highest pressure load of 0.65 psi 2 /Hz (168 db) on steam dryer during BWR power uprate operation 13

BWR Unit 2 Replacement Steam Dryer 14

BWR Unit 2 Steam Dryer Pressure Spectral Densities (790 MWe Original Licensed Power Level) 15

BWR Unit 2 Steam Dryer Pressure Spectral Densities (930 MWe Power Uprate Power Level) 16

Safety Relief Valve Damage In late 2005, SRV in BWR Unit 2 experienced short circuiting Unit 2 reduced power for inspection with broken SRV actuator parts found Both BWR units shut down for inspection with damage found to several SRVs SRV damage caused by severe vibration from acoustic resonance As a result, licensee initiated program to eliminate acoustic resonance from BWR steam lines 17

BWR Acoustic Resonance Elimination Analysis indicated that SV and SRV branch line length could not be reduced sufficiently to cause acoustic resonance to occur at steam velocity beyond operating conditions Licensee installed deadleg T-connection pipe in SV and SRV branch lines to effectively lengthen branch line and cause acoustic resonance to occur at lower steam velocity with reduced pressure fluctuations Upon reactor restart, measurements indicated significant acoustic resonance sources eliminated 18

Acoustic Resonance Lessons Learned NRC Regulatory Guide 1.20 revised to provide guidance on potential adverse flow effects Operating BWRs proposing power uprate and new BWR applications evaluate potential adverse flow effects from acoustic resonance Vendors have developed proprietary methods using data from replacement steam dryers and steam lines to determine pressure load and stress on steam dryers BWR licensees monitor steam dryer and steam line data during power ascension and implement steam dryer inspection program during refueling outages 19

References S.A. Hambric, et al., Flow-Induced Vibration Effects on Nuclear Power Plant Components Due to Main Steam Line Valve Singing, U.S. NRC NUREG/CP-0152, Volume 6, Proceedings of the Ninth NRC/ASME Symposium on Valves, Pumps and Inservice Testing, 2006. G. DeBoo, et al., Identification of Quad Cites Main Steam Line Acoustic Sources and Vibration Reduction, 2007 ASME Pressure Vessels and Piping Division Conference, Proceedings of PVP2007, July 2007. S. Ziada, Flow-Excited Acoustic Resonance in Industry, Institute of Thermomechanics, Flow Induced Vibration, Zolotarev & Horacek, eds., Prague, 2008. 20