Pretreatments to LLE

Similar documents
Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

Thermo Scientific Dionex SolEx SPE Cartridges

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

GC Injectors. GC Injectors

PROTOCOL FOR FREE LIPID SOP

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

TYPES AND APPROPRIATE INJECTORS

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Standard Operating Procedure for Oil & Grease Method EPA1664A

Chemistry Instrumental Analysis Lecture 29. Chem 4631

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

Environmental Parallel Evaporation Guide EPA Compliant Solvent Concentration

How Important is Performance to your SPE Method Development?

Training Papers Distillation with a Rotary Evaporator

300 series HPLC autosamplers

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.

Methods of solid phase extraction. Methods of solid phase extraction

PARTS CLEANING AND DEGREASING

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Author: JOHN BARLEY, PRODUCT MANAGER, SP INDUSTRIES INC.

160 EXTRACTION. Liquid/Liquid Extraction Apparatus. Continuous Liquid/Liquid Extraction with Built-in SLOW-DRY Concentrator

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Determination of the enthalpy of vaporization of liquids

Freeze Dry Systems and Accessories

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

RESOLUTION OIV-OENO MONOGRAPH ON TANNINS UPDATE OF THE METHOD FOR DETERMINATION OF POLYPHENOLS

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

Laboratory Freeze Dryers Routine Applications

LYOPHILIZATION- THE PROCESS AND INDUSTRIAL USE

Chromatography. Research Supplies. 2014/2015 Catalog

Systems. Visit us at

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

Thermo Scientific Model 1160 Principle of Operation

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

Introduction to Pharmaceutical Freeze Drying

Intelligent. Evaporation.... no task too big

Biotage VacMaster 10 & 20 Sample Processing Station. Operation Manual

Evaporators, Rotary. Total concentration... technology and performance in harmony 13

INCREASE YOUR LAB EFFICIENCY

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

GAS CHROMATOGRAPHY PURDUE UNIVERSITY INSTRUMENT VAN PROJECT. DEMYSTIFICATION ACTIVITY FOR THE GAS CHROMATOGRAPH (Revised: ) INTRODUCTION

Intelligent. Evaporation. Premium Safety Standards Superior Ease of Use Reduced Cost of Ownership

IQ/OQ Protocol Installation Qualification/ Operation Qualification

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

CALIDUS tm the Modular micro Gas Chromatograph

Adsorption Chillers Energysmart Green Cooling

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

FreeZone 2.5 Liter Benchtop Freeze Dryers

1 L Rotary Vacuum Evaporator Instruction Manual

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

Hei-VAP Precision. for the highest level of accuracy. Vacuum Pumps. RPM Regulated Vacuum Pumps

Freeze Dry Systems and Accessories

5 Separation Processes

Laboratory Diaphragm Pumps for Air Gases Liquids

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Premium Laboratory Equipment HBX EVAPORATION GUIDE

GAW - WCCAP recommendation for aerosol drying

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

For the successful distillation of heat sensitive materials

Choosing the best vacuum concentrator for your laboratory. Tips and best practices from industry pioneers

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

1. Desorption Tube Conditioning System

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

Solid Phase Extraction (SPE) for the Analysis of Semivolatile. According to EPA Method 625. Derick Lucas, PhD R&D Sample Preparation Chemist

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Operating manual ELECTRIC ASPIRATOR 00) : 1) Page 1

Purge and Trap Troubleshooting Made Easy?

Freeze Dry Systems and Accessories

Experiment 4: Purification of Liquids by Distillation

Vernier Mini GC Plus Gas Chromatograph (Order Code: GC2-MINI)

OURSE TITLE : MASS TRANSFER OPERATIONS 1 COURSE CODE : 5071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 52 CREDIT : 4 TIME SCHEDULE

Reliable elimination of particles and micro organisms PAGE Protein Precipitation Fast and effective sample clean up of biological samples

Accessories. for perfect freeze drying

Rotary Evaporator Replacement Glassware

Shyam Enterprises 9 PACKAGE UNIT

Operation Manual R205BV, R209BV

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Multifunctional individualists

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Scaled Down EPA Methods 8270 and 625 Solid Phase Extraction of 100 ml Samples or Less

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

KPR SOLVENT CONCENTRATING SYSTEMS

Transcription:

Updated: 12 October 2014 Print version CEE 772: Instrumental Methods in Environmental Analysis Lecture #11 Sample Preparation: Basics and Physical Methods (cont.) (Skoog, nothing) (Harris, Chapt. 28) (817-839) David Reckhow CEE 772 #11 1 Pretreatments to LLE Acidify to <2 8040: Phenols No ph adjustment 8060: Phthalate Esters 8100: PAHs Neutralize 8080: Oganochlorine pesticides & PCBs 8090: nitroaromatics & cyclic ketones 8140: organophosphorus pesticides Alkaline (>11) then acidify (<2) 8250 & 8270: GC/MS for Semivolatiles Drying is sometimes necessary 10 cm column of anhydrous Na 2 SO 4 Addition of powdered anhydrous MgSO 4 David Reckhow CEE 772 #11 2 1

Soxhlet Extraction David Reckhow CEE 772 #11 3 Soxhlet Extraction Good for soils, sediments & sludges Used with thimbles Or glass wool plugs Typical extraction solvents Toluene/methanol (10:1) Acetone/hexane (1:1) Methylene chloride David Reckhow CEE 772 #11 4 2

Distillation Theory David Reckhow CEE 772 #11 5 Kuderna Danish Concentrators Ideal for concentrating ether extracts Common procedures Use with heated water bath Boiling chips Good to pre wet snyder column by adding 1 ml of solvent to top Balls should chatter, but chambers should not be flooded May take 10 20 minutes Stop at apparent volume of ~1 ml Exchange solvent may be added at this time & concentration continued David Reckhow CEE 772 #11 6 3

Rotary Evaporation Rotary evaporators (also called "rotavaps" in lab slang) are used to remove solvents from reaction mixtures and can accommodate volumes as large as 3 liters. A typical rotary evaporator has a heatable water bath to keep the solvent from freezing during the evaporation process. The solvent is removed under vacuum, is trapped by a condenser and is collected for easy reuse or disposal. Most labs use a simple water aspirator vacuum on their rotavaps, so a rotavap can not be used for air and watersensitive materials unless special precautions are taken. David Reckhow CEE 772 #11 7 Use of Rotavaps 1. Empty and then replace the solvent collection flask on the unit. 2. Place your flask on the rotary evaporator. 3. Use the speed control to rotate the flask. A typical rotavap uses a variable speed sparkless induction motor that spins at 0 220 rpm and provides high constant torque. 4. Turn on the aspirator vacuum. On most models, the vacuum on/off control is managed by turning a stopcock at the top of the condenser. 5. Lower your flask into the water bath. On most models, a convenient handle (with height locking mechanism) moves the entire condenser/motor/flask assembly up and down. You can also adjust the tilt of the condenser assembly. Be sure not to put the flask into a water bath that exceeds the boiling point of your solvent!! For small amounts of common solvents you don't need to turn on the bath heater. 6. The solvent should start collecting on the condenser and drip into the receiving flask. Some solvents (such as ether or methylene chloride) are so volatile that they will also evaporate from the receiving flask and be discharged down the drain. To prevent this you can place a cooling bath on the receiver or (on some models) use a dry ice condenser. 7. Once all your solvent has evaporated, release the vacuum, raise the flask out of the water bath and turn off the rotation. Remove your flask. David Reckhow CEE 772 #11 8 4

Rotavap tips Always use distilled water in your heating bath. Otherwise, scale will build up in the bath and coat the thermistor and heating coils. This is very difficult to remove and reduces the efficiency of the bath. In addition, regular tap water will promote the growth of spectacularly disgusting algae colonies, particularly during the summer months. To reduce the amount of evaporation from your water bath, simply add some small plastic balls to the water bath. This reduces the surface area for evaporation and therefore the rate at which the water level drops. The ground glass joint holding your flask does not need to be greased, but on rare occasions it (or the bump bulb) may get "frozen". Some companies sell special joint clips that can free frozen joints simply by screwing them in one direction. David Reckhow CEE 772 #11 9 David Reckhow CEE 772 #11 10 5

Freeze Dryers in EVE Manifold Dryer Labconco Freeze Dryer 8 8 liter Marcus 5c Tray Dryer Labconco FreeZone 6 6 liter Marston 24 David Reckhow CEE 772 #11 11 Freeze Drying I Three stages Pre freezing at atmospheric pressure (A) Slow cooling produces large crystals, which improves sublimation Fast cooling better preserves biological samples Primary Drying Pressure is lowered in sample compartment (C ) to 0.06 mbar or below Sample pressure drops (B) and sample warms leading to removal of ice by sublimation Rate depends on difference between vapor pressure of the product (B) compared to the vapor pressure of the condenser (D) Condenser is usually 20 C cooler than product (e.g., 50 to 80C) David Reckhow CEE 772 #11 12 6

Freeze Drying II Secondary Drying Removal of last 5 10% of moisture Higher temp: isothermal desorption 30 50% of primary drying time Source of heat during drying Ambient (room) heat Manifold drying (Model 8) May be increased with a water bath Thermal conductor shelf Tray drying (FreeZone 6) David Reckhow CEE 772 #11 13 Tray Dryers Typical Sublimation Cycle Temperature A B D When primary drying is complete, product temperature equals shelf temperature As drying proceeds, product temperature Remains below shelf temperature Pressure C Time David Reckhow CEE 772 #11 14 7

External valve Manifold Dryers David Reckhow CEE 772 #11 15 Flasks Manifold Dryers David Reckhow CEE 772 #11 16 8

Manifold Dryers Pre freezing Either shell freeze or angle flask to avoid breakage Water expands when frozen David Reckhow CEE 772 #11 17 Purge and Trap The purge and trap method is used specifically to remove and concentrate volatile analytes from liquids or solids. The goal in this case is to concentrate 100% of the analyte Purge gas is swept through the heated sample and volatilized components go with it into a trap. The trap contains particles made of adsorbent compounds that the analytes adsorb onto. After trapping the analytes for a specified procedure time, the flow through the trap is reversed and analytes desorb back off of the trap and into the injection port of the GC. David Reckhow CEE 772 #11 18 9

Purge & Trap A. purge & simultaneous trap B. thermal desorption David Reckhow CEE 772 #11 19 P&T EPA purging vessel design 5 ml sample Room temp. Use N 2 or He 20 40 ml/min 10 15 min David Reckhow CEE 772 #11 20 10

P&T Example Trap Desorb @ 180 C 20 60 ml/min backflush 1.5 4 min Tenax 2,6 diphenylene oxide polymer OV 1 Methyl silicone polymer Used for EPA methods# 8010: Halogenated VOCs 8015: Nonhalogenated VOCs (high temp): Ether, Ethanol, MEK 8020: Aromatic VOCs (BTEX, chlorobenzenes) 8030: (high temp) Acrolein, Acetonitrile, Acrylonitrile From CFR Title 40 David Reckhow CEE 772 #11 21 Purge and Trap Commercial Unit Varian LSC 2000 David Reckhow CEE 772 #11 22 11

Closed Loop Stipping Brechbuhler unit Marston 5 High concentration factor 1 liter of sample down to 0.010 ml extract David Reckhow CEE 772 #11 23 CLSA Purge and Adsorb on 1.5 mg activated carbon Extract into carbon disulfide David Reckhow CEE 772 #11 24 12

Solid Phase Extraction Steps 1. Addition of solvent to solvate the functional groups 2. Adsorption of sample (Loading step): 1 ml to 1 L 3. Sample clean up 4. Elution From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 25 SPE cont. Three formats: disks, cartridges & syringe barrel From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 26 13

SPE cont. Cut away of a syringe barrel From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 27 SPE cont. Syringe barrel method with vacuum manifold From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 28 14

SPE cont. Other methods of sample application to syringe barrels From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 29 Disk methods SPE cont. From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 30 15

SPE cont. Manifold assembly for disk extractions From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 31 SPME SPME is used to extract from liquid, air, or sludge without using any solvents. A silica fiber coated with a stationary phase for a GC is attached to a syringe. The fiber is exposed to sample for a certain time to allow the phase to become saturated with analyte. After sampling, the fiber is retracted into the syringe and the syringe gets injected into the inlet of the GC. SPME does not remove all of the analyte because it is an equilibrium reaction. It usually can obtain 30-50% of the molecules. Because the binding to the stationary phase of the fiber is a partitioning reaction, there is an equilibrium involved. Equilibration time for analytes must be obtained using calibration experiments. David Reckhow CEE 772 #11 32 16

SPME Schematic of a typical setup From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 33 From: Junk, 1987 David Reckhow CEE 772 #11 34 17

SPE Common sorbents used for SPE From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 35 SPE cont. Bonded phases From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 36 18

SPE cont. Ion exchange mechanism for 2,4 D From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 37 SPE Method for elution of reverse phase SPE using ethyl acetate and methanol From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 38 19

SPE appl. Selective elution of alachlor and its sulfonic acid metabolite with ethyl acetate and methanol From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 39 Breakthrough curve Atrazine on C18 From: Solid Phase Extraction by Thurman & Mills David Reckhow CEE 772 #11 40 20

Simple Hydrophobicity Test Hydrophobic NOM Retained on XAD 8 TOC#1 TOC#2 Mesophilic NOM Retained on XAD 4, but not on XAD 8 TOC#2 TOC#3 Hydrophilic NOM Not retained TOC#3 TOC#1 TOC#2 TOC#3 Test Water XAD-8 XAD-4 David Reckhow CEE 772 #11 41 To Waste Isolation/Fractionation based on Hydrophobicity Back elution with NaOH Allows recovery of fractions and check of direct fractionation Desorbable hydrophobics = TOC#4 Desorbable mesophilics = DOC #5 NaOH TOC#4 Test Water XAD-8 XAD-4 TOC#5 David Reckhow CEE 772 #11 42 To Waste 21

Fractionation based on Hydrophobicity II A. XAD-8 Eluent Water Sample Humic Substances Eluent XAD-8 B. XAD-4 Semi-Hydrophilic NOM XAD-4 Eluent Eluent Permeate RO Hydrophilic NOM Rotary Evaporator Condensate David Reckhow (Retentate) CEE 772 #11 43 Comprehensive NOM Fractionation Filter Water Sample Hydrophobic Resin Amberlite XAD-8 Hydrophobic Bases Weak Hydrophobic Acids Hydrophobic Neutrals Cation Exchange Resin MSC-1 Hydrophilic Bases Anion Exchange Resin Duolite A-7 Humic Acid Amberlite XAD-8 Fulvic Acid David Reckhow CEE 772 #11 44 Hydrophilic Neutrals Hydrophilic Acids 22

Molecular Size separations Ultrafiltration series vs parallel membrane calibration Size Exclusion Chromatography HPSEC vs LC Others FFF Stirrer Membrane David Reckhow CEE 772 #11 45 To next lecture David Reckhow CEE 772 #11 46 23