Flameproof Manual Call Points Series MCP

Similar documents
Flameproof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Flameproof Manual Call Points

Integrated Solutions Low Voltage Systems

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Manual Alarm Call Points

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Explosion Proof Combination Signal db (A) / 5 Joule

Fire Alarm or Emergency Call Points

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Indoor/outdoor resistance thermometer Model TR60

Explosion-proof Immersion Heater Type D-8660

Hazardous Area Signalling

DB4 Range - SPEAKERS - Up to 25 Watts

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

IECEx Certificate of Conformity

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

DB1 Range - HORNS - Up to 103 db(a)

UL HAZARDOUS LOCATIONS SERVICES

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Temperature Measurement Transmitters for field mounting

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Certification Supplement Manual

INSTRUCTION MANUAL (ATEX / IECEx)

DICTATOR Hold-Open Systems for Hazardous Areas

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

ELECTRICAL EX EQUIPMENT

manual addendum DELPHI Ex

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Ex LED light fittings

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Fan Heaters Type VLEx

Operating Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Manual Power relay SR853

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION & SERVICE MANUAL

TYPE APPROVAL CERTIFICATE

ExPolar Heating System

IECEx Certificate of Conformity

Beacons, Lights & Strobes

Illumination unit For sight glass level indicator Model LGI

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Sinus Jevi (Explosion-Proof) Condens Heaters

IECEx Certificate of Conformity

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Approved by: Document no.: EGT

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

standards: standards:

Certification Supplement Manual

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Dräger Polytron 5700 IR Detection of flammable gases and vapours

OPTIBAR DP 7060 Supplementary Instructions

Earth-Rite II PLUS Static Earthing System

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Guide for hazardous areas

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Guide to Hazardous Location Approvals:

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE

ATM Lighting sp. z o.o

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Equipment and Solutions

How Limit Switches Can Stop Machines from Going Boom

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Fixed Gas Detection System/Meridian CERTIFICATION

Certification Supplement Manual

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Rosemount 248 Temperature Transmitter

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Certificate of Conformity

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Transcription:

> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and lift flap > Optional extras include stainless steel lift flap, duty and tag labels www.stahl.de Yodalex range Manual call points designed for use in hazardous or harsh environments ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x 13915E00 Explosion Protection Global (IECEx) Gas and dust IECEx BAS 08.0089X IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008 Ex d IIC T6 Ta -55... +70 C Gb Ex tb IIIC T85 C Ta -55... +70 C Db IP66 Europe (ATEX) Gas and dust Baseefa 08ATEX0269X EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009 E II 2 G Ex d IIC T6 Ta -55... +70 C Gb E II 2 D Ex tb IIIC T85 C Ta -55...+70 C Db IP66 Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (GOST K), Russia (GOST R) WebCode A Signalling Devices /1

Versions Break Glass (BG) 14716E00 Push Button (PB) 04035E00 Selection Table Version Version Enclosure colour Order number Art. no. Weight kg Break Glass (BG) red normal (R) /BG/SP/Ex/A+B+C+D/EU/R 205324 1.000 ATEX certification, Push Button (PB) red normal (R) /PB/SP/Ex/A+B+C+D/EU/R 205334 1.000 Break Glass (BG) red normal (R) /BG/SP/EX/A+B+C+D/IN/R 212400 1.000 IECEx certification, Push Button (PB) red normal (R) /PB/SP/Ex/A+B+C+D/IN/R 212401 1.000 Break Glass (BG) red normal (R) /BG/SP/EX/A+B+C+D/RU/R 212402 1.000 GOST R certification, Push Button (PB) red normal (R) /PB/SP/Ex/A+B+C+D/RU/R 206660 1.000 Note, variations and different unit colours are available, to order these please use the table below Type Code Variations / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts 1 change over SP 2 change over DP Explosion protection standard Ex Cable entries standard 4 x M20 with 3 x Ex d stopping plugs and 1 x dust cap glands to be ordered separately Certification ATEX EU IECEx IN GOST R RU Colour red R blue B green G yellow Y black BK yellow / black stripe YB Labels (please specify wording) Additional approvals lift flap (break glass version only) end of line resistor inline resistor end of line and Inline resistor LED signal duty label tag label A+B+C+D LF EOL IL ILEOL LED D T L /2 Signalling Devices

Technical Data Electrical data Rated operational voltage Switching capacity 12... 50 V DC, 12... 250 V AC DC 12... 30 V 3 A 30... 50 V 1 A AC 12... 250 V 5 A Contact element standard: 1 change-over contact optional: 2 change-over contacts Switch NO or NC System test Test key provided Ambient conditions Operating temperature -40... +70 C range Mechanical data Material Enclosure material glass fibre reinforced polyester (GRP) Surface finish two pack, acrylic polyurethane, various colour options Degree of protection IP66 acc. to IEC 60529 Cable entries 4 cable entries, supplied with (3x) Ex d stopping plugs and (1x) dust cap Position of cable entries Connection Terminals 7 way terminal block., 4 mm 2 Earth connection provided as standard LED status indication optional: red LED status indication (up to 24 V DC) Lift flap stainless steel (break glass version only) Duty label Metalised polyester, customer to specify wording / symbols (see main picture for example) Tag label Stainless steel tag with polyester label, customer to specify max 9 characters Resistors Customer to specify value Mounting / Installation Assembly and Spare Parts via holes through the back box see operating instruction for full details Designation Figure Description Group Order number Art. no. WebCode Cable gland Compound Barrier Cable IIB + H 2 8163/2-20- 138888 8163J Glands Ex d and Ex e for all and IIC PXSS2K-M20 Types of Unarmoured Cables Note Break glass call point 14976E00 14742E00 13952E00 Compound Barrier Cable Glands Ex d and Ex e for all Types of Armoured Cables Approvals of cable entries have to be observed. Break glass call point with lift flap IIB + H 2 and IIC 16555E00 8163/2-20- PX2K-M20 Push button call point 138875 8163I Signalling Devices /3

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 27,24 ± 0,1 [1,07 ± 0,004] 78 [3,07] 39 [1,54] Ø 5,50 [Ø 0,22] 74 [2,91] 11,24 ± 0,1 [0,44 ± 0,004] 107,50 ± 0,1 [4,23 ± 0,004] 13953E00 Break glass manual call point 52 [ 2,05] 10 [ 0,39 ] 27 [ 1,06 ] 40 [ 1,57] 16544E00 Duty label Tag label Lift flap 16554E00 /4 Signalling Devices

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 27,24 ± 0,1 [1,07 ± 0,004] 78 [3,07] 39 [1,54] Ø 5,50 [Ø 0,22] 74 [2,91] 98 [ 3, 86] 11,24 ± 0,1 [0,44 ± 0,004] 107,50 ± 0,1 [4,23 ± 0,004] 13954E00 Push button manual call point 52 [ 2,05] 27 [ 1,06 ] 10 [ 0,39 ] 40 [ 1,57] Duty label Tag label 16545E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Signalling Devices /5