Explosion Proof Manual Call Points Series MCP

Similar documents
Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Flameproof Manual Call Points

Integrated Solutions Low Voltage Systems

Manual Alarm Call Points

Fire Alarm or Emergency Call Points

Explosion Proof Combination Signal db (A) / 5 Joule

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

INSTRUCTION MANUAL (ATEX / IECEx)

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

INSTRUCTION & SERVICE MANUAL

DB4 Range - SPEAKERS - Up to 25 Watts

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Hazardous Area Signalling

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Indoor/outdoor resistance thermometer Model TR60

IECEx Certificate of Conformity

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Explosion-proof Immersion Heater Type D-8660

standards: standards:

ELECTRICAL EX EQUIPMENT

Fixed Gas Detection System/Meridian CERTIFICATION

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

manual addendum DELPHI Ex

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Approved by: Document no.: EGT

Ex LED light fittings

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Operating Instructions

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

DICTATOR Hold-Open Systems for Hazardous Areas

Industrial & Hazardous Area Electrical Equipment

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Certificate of Compliance

IECEx Certificate of Conformity

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

DB5 Intrinsically Safe Sounder Type DB-5

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

DB1 Range - HORNS - Up to 103 db(a)

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Certification Supplement Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Earth-Rite II PLUS Static Earthing System

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Web: LGM Products Ltd.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Sinus Jevi (Explosion-Proof) Condens Heaters

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Certification Supplement Manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

TYPE APPROVAL CERTIFICATE

Electrical Installations Design, Selection, Erection and Inspection

official distributor of Newson Gale Ltd.

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

IECEx Certificate of Conformity

TECHNICAL MANUAL EXPLOSION PROOF MANUAL CALL POINT BCP 135. Scope: EXcite USER MANUAL BCP 135. Date: Page: Page 1 of 6.

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Quick Start Guide For the

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

An optional Ex e terminal chamber is available (see certification section for further details).

INSTRUCTION MANUAL (ATEX / IECEx)

Intrinsically Safe Solutions

Beacons, Lights & Strobes

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Dräger Polytron 5720 IR Toxic Gas Detection

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Illumination unit For sight glass level indicator Model LGI

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

Exp, pressurized systems

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Manual Power relay SR853

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Technical Manual for the Alarm Pull Station PH1

NGC-20-C-E and NGC-20-CL-E

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Datasheet - AZM 161SK-12/12RK-024

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Temperature Measurement Transmitters for field mounting

Transcription:

> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and protection flap > Optional extras include stainless steel lift flap, duty and tag labels www.stahl.de Yodalex range Manual call points designed for use in hazardous or harsh environments ATEX / IECEx / GOST Zone 0 0 For use in x x x x 9E00 Explosion Protection Global (IECEx) Gas explosion protection Ex d IIC T (Ta -ºC to +0ºC) Gb ust explosion protection Ex tb IIIC T8ºC b IP A Europe (ATEX) Ex d IIC T (Ta -ºC to +0ºC) Gb Gas explosion protection E II G Ex d IIC T (Ta -ºC to +0ºC) Gb ust explosion protection E II Ex tb IIIC T8ºC b IP A Certificates and approvals IECEx IECEx BAS 08.0089 Europe (ATEX) Baseefa08ATEX09X Certificates IECEx, ATEX, Brazil (METRO), Russia (GOST-R) WebCode MCPA Control evices /

Versions Break Glass (BG) E00 Push Button (PB) 00E00 Selection Table Version Version Enclosure colour Order number Art. no. Weight kg Break Glass (BG) red normal (R) MCP/BG/SP/Ex/A+B+C+/EU/R 0.000 Manual Call Points, ATEX certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+/EU/R 0.000 Break Glass (BG) red normal (R) MCP/BG/SP/EX/A+B+C+//R 00.000 Manual Call Points, IECEx certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+//R 0.000 Break Glass (BG) red normal (R) MCP/BG/SP/EX/A+B+C+/RU/R 0.000 Manual Call Points, GOST R certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+/RU/R 00.000 Note Accessories, variations and different unit colours are available, to order these please use the table below position of cable entries A B A B Contacts LE Resistors Enclosure colours C 9E00 Break glass call point Push button call point cable entries, supplied with (x) stopping plugs and (x) dust cap standard: change-over contact optional: change-over contacts optional: LE-status indication (up to V C) various resistance values on request additional colours on request C 9E00 / Control evices

Type Code Variations MCP / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts change over SP Explosion protection change over P standard standard x M0 with x stopping plugs and x dust cap glands to be ordered separately Certification ATEX EU IECEx GOST R Colour red R blue green yellow Ex A+B+C+ RU B G Y Accessories lift flap (break glass only) LF end of line resistor inline resistor EOL IL end of line and Inline resistor ILEOL Labels (please specify wording) LE signal duty label tag label LE T Control evices /

Technical ata Electrical data Rated operational voltage Switching capacity Contact element Schematic... 0 V C,... 0 V AC C... 0 V A resitive or A inductive 0... 0 V A resitive or inductive AC... 0 V A resistive or inductive standard: change-over contact optional: change-over contacts Normally open with series monitoring Internal switch connections armed 9 End of line device 8E00 89E00 The call point is supplied in two versions: supplied with or without a monitoring resistor. The version with the monitoring resistor should be connected as shown above. Check panel instructions to ensure the correct value resistor is fitted. If not required, remove and connect as shown in 'A' or 'B' Ratings: Vac: 0 V max. / V min. Imax: A resistive. Vdc: 0 V max. / V min. Contact resistance: 0 millioms max. Conductor size:. sq.mm max. per terminal. Normally open Normally closed End of 9 line device Monitoring device A B 8E00 80E00 When supplied without the monitoring resistor the call point should be connected as shown in 'A' or 'B' above. Legend 9 = Optional end of line resistor Ambient conditions Ambient temperature -... + 0 C Max. relative humidity 9 % at 0 C Mechanical data Enclosure material glass fibre reinforced polyester (GRP) Colour red egree of protection IP cable entries, supplied with (x) stopping plugs and (x) dust cap Connection Terminals way terminal block., mm Earth connection provided as standard Assembly / Installation Assembly via holes through the back box / Control evices

Accessories and Spare Parts esignation Illustration escription Group Order number Art. no. WebCode Cable gland Compound Barrier IIB + H and IIC 8/-0-PXSSK-M0 8888 8J Cable Glands Ex d and Ex e for all Types of Unarmoured Cables Note 0E00 Compound Barrier Cable Glands Ex d and Ex e for all Types IIB + H and IIC 8/-0-PXK-M0 88 8I E00 of Armoured Cables Approvals of cable entries have to be observed. imensional rawings (All imensions in mm / inches) - Subject to Alterations mm /.9, mm /. ", mm /. ", mm /. " mm /.9 ", mm /. " 98 mm /.9 " Break glass call point 0E00 Push button call point We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 0E00 Control evices /