Multi Box HP 10. Accessories, split air to water heat pump PRINT APPROVAL 1 NOVEMBER Installation instructions (2012/11)

Similar documents
GREENSOURCE INSTALLATION MANUAL AIR TO WATER HEAT PUMP WITH DOMESTIC HOT WATER DISTRIBUTION UNIT 6 KW, 7 KW AND 9.5 KW UK/IE (2010/01)

INSTALLATION, COMMISSIONING AND SERVICING INSTRUCTIONS GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Greenline HE C6-C11 E6-E17 Installer Guide

Greenline HE. C6-C11 E6-E11 1x230V. Installer Guide (2012/06) en I

Operating Instructions

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

Connecting cable. Installation instructions (2018/04) US

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Operating instructions

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

SHOWER PUMP. Installation and User Guide. These instructions are to be left with the user

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

General safety precautions English

For the heating engineer. Installation manual. Interface 0-10V VR34

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Unvented Electric Water Heater 10/15 litre Undersink

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

Room-temperature (economy/night) unit TR 212 E

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

General safety precautions English

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Operating instructions

VIESMANN. Installation instructions VITODENS 200-W. for contractors

Quickheat 30 weather compensated boiler control

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

allstor buffer cylinder Instructions for use Instructions for use For the operator Publisher/manufacturer Vaillant GmbH

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Combi Eco Elite Range. User s Guide and Important Warranty Information

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

FP120-Z1 Power supply kit A (70 W) Technical Manual

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

GB162 Concentric Horizontal Vent Kit

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

REMOTE CONTROL FOR CHILLER MYCHILLER

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data Manual

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Networked Access Control Panel. Installation Guide

Dene Bath Shower Mixer

Installation and maintenance instructions

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Baxi Maxflow Combi WM

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Greenstar System Filter

HBPS PRESSURE SENSOR For analogue pressure measurement of refrigerants

Product Data Sheet. Remote Terminals. Features:

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

TR 0603mc U Solar Controller

Door Release Power Supply

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

RTD-10 Installation Instructions

TOSHIBA AIR CONDITIONING

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

DESCRIPTION. 42 mm. 125 mm

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

T550i power shower pump Installation and operating instructions

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

SHOWER PUMP. Installation and User Guide. These instructions are to be left with the user 1

General Routing Interface

Operating instructions

TYNE. Installation and Operating Instructions. Thermostatic bath shower mixer. Installers please note these instructions are to be left with the user

Planning guide. Atec.

Earth-Rite II PLUS Static Earthing System

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

O CRC100. Comfort Room Controller (2015/01) en

GREENSPRING CWi47 INSTALLATION AND OPERATING INSTRUCTIONS WALL HUNG RSF GAS CONDENSING INSTANTANEOUS WATER HEATER FOR MAINS FED DOMESTIC HOT WATER

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SURFACE WARM CEILING HEATERS

HBTS Temperature Sensor For temperature measurement in refrigeration systems

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Guide. Promax SL Condensing Central Heating Boiler

Sema thermostatic bar mixer Installation and operating instructions

Transcription:

Installation instructions Accessories, split air to water heat pump Multi Box HP 10 6 720 801 399-00.1I 6 720 804 408 (2012/11)

Table of Contents Table of Contents 1 Key to symbols and safety instructions................... 2 1.1 Explanation of symbols........................... 2 1.2 Safety regulations............................... 2 2 regulations and Standards.............................. 2 3 Multi Box HP 10....................................... 3 4 Standard delivery..................................... 3 4.1 Items included.................................. 3 4.2 Not included in the delivery....................... 3 5 Fitting............................................... 3 6 Technical information.................................. 5 6.1 Technical data.................................. 5 6.2 Dimensions.................................... 5 6.3 Cabling........................................ 5 7 Installation........................................... 6 7.1 Handling circuit boards........................... 6 7.2 CAN-BUS...................................... 6 7.3 CAN-BUS cable................................. 6 Additional symbols Symbol Meaning a step in an action sequence a reference to a related part in the document or to other related documents a list entry a list entry (second level) Table 1 1.2 Safety regulations General information Please read these instructions carefully and keep them for future reference. Installation and commissioning The Multi Box may only be installed and started up by a competent person. Maintenance and repairs Repairs must only be carried out by a competent person. Inadequately performed repairs can put the operator at risk and impair operation. Use only original spare parts. The heat pump which incorporates this Multi Box unit must be inspected annually and serviced as necessary by a competent person. 2 REGULATIONS AND STANDARDS Installation of this heat pump should be done in accordance with MCS/MIS 3005. 8 Electrical connections................................. 7 8.1 Multi Box HP 10................................. 7 8.2 Wiring diagram Multi Box HP 10 central fault alarm.... 8 8.3 Wiring diagram Multi Box HP 10 mixed circuit 2..... 11 1 Key to symbols and safety instructions 1.1 Explanation of symbols Warning symbols Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. NOTICE indicates possible damage to property or equipment, but where there is no risk of injury. CAUTION indicates possible injury. WARNING indicates possible severe injury. DANGER indicates possible risk to life. Important information Notes contain important information in cases where there is no risk of personal injury or material losses and are identified by the symbol shown on the left. They are bordered by horizontal lines above and below the text. This appliance must be installed and serviced only by a competent person in accordance with the current: IEE Regulations, Building Regulation, Building Standards (Scotland) (Consolidation), Building Regulations (Northern Ireland), local water by-laws, Health & Safety Document 63S (The Electricity at Work Regulations 1989), IS 813 (Eire) and other local requirements. The relevant Standards should be followed, including: BS7074:1: Code of practice for domestic and hot water supply EN:12828: Central heating for domestic premises BS7593: Treatment of water in domestic hot water central heating systems BS EN 14511: Requirements heat pumps for space heating BS EN 378: Safety and environmental requirements for heat pumps The Health and Safety at Work Act 1974 The Management of Health and Safety at Work Regulations 1999 The Construction (Health, Safety and Welfare) Regulations 1996 The Construction (Design and Management) Regulations 1994 The Lifting Operations and Lifting Equipment Regulations 1998 Where no specific instruction is given, reference should be made to the relevant codes of Practice. Potable water: All seals, joints, compounds (including flux and solder) and components used as part of the secondary domestic water system must be approved for use with potable water supplies. This is to certify that the above ranges of products manufactured by Bosch Thermotechnology have been tested and found to comply with: the requirements of the (Water Fittings) Regulations 1999 for England and Wales, the Water Byelaws 2000, Scotland and the Water Regulations Northern Ireland. the requirements of the UK Building Regulations: The Building Regulations 1991 (England & Wales) Requirements G3, L1 and Regulation 7. 2 Multi Box HP 10 6 720 804 408 (2012/11)

Multi Box HP 10 The Building Standards (Scotland) Regulations 1990. Regulation 10 (B2), 22 (J3.3a and J3.4), 27 and 28 (P2.6 and P3). The Building Regulations (Northern Ireland) 2000. 3 Multi Box HP 10 The Multi Box HP 10 is designed for operation with a split air to water heat pump. It includes a PCB (IOB-B) for the control of the following functions: NOTICE: If an IOB-B card is already installed in the system (externally or in the internal unit of the heat pump), only the central fault alarm function can be used. Check whether an IOB-B card has already been installed. 4 Standard delivery 4.1 Items included Multi Box HP 10 Cable glands, 6 pcs. Installation manual 4.2 Not included in the delivery CAN-BUS cable Flow sensor Mixer Heating circuit pump DHW circulation pump, domestic hot water Room temperature controller Cooling is not an option in the UK. General fault alarm Mixed circuit 2 External input 1, 2 Signal output, cooling DHW circulation pump, domestic hot water 5 Fitting 6 720 801 399-05.1I Fig. 1 Fasten to the wall near the heat pump. To do so, secure the four corners of the box with screws suitable for the wall material. Following mounting on the wall, make electrical connections (.Chapter 8). Select the required address and program (.Chapter 8). Screw the cover on to the box. Multi Box HP 10 6 720 804 408 (2012/11) 3

Fitting 2 1 6 720 803 881-01.1I Fig. 2 8)Alternative positioning of the IOB-B card [1] Multi Box HP 10 [2] Control panel in Hydrolight/Hydrocomfort module If an IOB-B card is not installed in the control panel of the internal unit of the heat pump, the card can be removed from the casing and fitted there. 4 Multi Box HP 10 6 720 804 408 (2012/11)

Technical information 6 Technical information 6.1 Technical data Unit Electrical connection values Electrical connection VAC/Hz 230 V/1-50 Hz IP rating IP X1 General information Dimensions (width x depth x height) mm 255 x 83 x 181 Weight kg 1.5 Table 2 Technical data 6.2 Dimensions 6 720 649 559-14.1I Fig. 3 Depth in mm 6 720 649 559-13.2I Fig. 4 Height and width in mm 6.3 Cabling Terminals: L, N, PE Terminals: 55, 56, 57 CAN-BUS Table 3 Cabling Power input Min. 0.75 mm 2 230 V connection Min. 0.75 mm 2 See requirement for CAN- BUS ( chapter 7.3) Multi Box HP 10 6 720 804 408 (2012/11) 5

Installation 7 Installation 7.1 Handling circuit boards CAUTION: Always wear a a ground-connected bracelet when handling electronics. Circuit boards with control electronics are sensitive to discharges of static electricity (ESD ElectroStatic Discharge) when handled. To prevent damaging the components, special care is therefore required when handled. 6 720 614 366-24.1I Fig. 5 Anti static bracelet Damage is usually latent, and a circuit board can operate correctly during commissioning but show signs of problems later. Charged objects may only be problematic if they are in close proximity to the electronics. Keep a distance of at least one metre from expanded polystyrene, protective plastic and other packaging, synthetic material (e.g. fleeces) and similar before starting work. A method for good ESD protection is a ground-connected bracelet when handling electronics. This bracelet must be put on before opening the screened metal bag/packaging or before exposing an installed board. The bracelet must be worn until the circuit board is enclosed in its screen packaging or closed electric box. Replaced, returned circuit boards must be handled in the same way. 7.2 CAN-BUS CAUTION: Interference. The CAN-BUS cable must be screened and laid with a minimum distance of 100mm separately from the power cable. CAUTION: Do not mix up the 12 V and CAN-BUS connections! The processors will be damaged beyond repair if 12 V is connected to the CAN-BUS. Ensure that the four cables which are to be connected to the contacts on the printed circuit boards are made with their corresponding markings. The printed circuit boards in the Hydrolight/Hydrocomfort unit, and accessories board if applicable, are connected via the CAN-BUS communication line. The CAN (Controller Area Network) is a system that facilitates communication between microprocessor-based modules/ printed circuit boards. A room controller is available as an accessory and must be connected by a CAN-BUS cable. Suitable cable for external laying is cable type LIYCY (TP) 2x2x0.5. The cable must be twisted pair and screened. The screen must only be earthed at one end and to the chassis. Maximum cable length is 30 m between the internal room controller and the internal Hydro unit. The CAN-BUS cable must not be routed together with the mains cable that carry 230 V or 400 V. The minimum clearance is 100 mm. Routing of these cable together with the sensor cables is not permitted. The connection between the circuit boards is by four wires, because the 12V-supply between the circuit boards must also be connected. The circuit boards have markings for both the 12V and CAN-BUS connections. 7.3 CAN-BUS cable Requirement for external CAN-BUS: Shielded line Twisted pair Minimum cross-section: 0.5 mm 2 Approved for outdoor applications Maximum length 30 m One end must be connected to the earth conductor (not GND) 6 720 614 366-25.1I Fig. 6 Using an anti static bracelet 6 Multi Box HP 10 6 720 804 408 (2012/11)

Electrical connections 8 Electrical connections 8.1 Multi Box HP 10 1 2 3 6 720 801 399-10.1I Fig. 7 Multi Box HP 10 [1] CAN-BUS term switch ON/OFF [2] Address selection [3] Program selection If the IOB-B PCB is the last component in the CAN-BUS chain, the term switch [1] must be in the "ON" position. Multi Box HP 10 6 720 804 408 (2012/11) 7

Electrical connections 8.2 Wiring diagram Multi Box HP 10 central fault alarm a) 1 2 3 b) 2b 2a 1 2 6 720 801 399-12.1I Fig. 8 Wiring diagram a) 230 V output signal b) voltage free contact a) 230 V output signal: [1] CAN-BUS connections [2] Central fault alarm, 230 V [3] Power supply, 230 V AC b) Voltage free contact: [1] CAN-BUS connections [2] Central fault alarm [2a] Signal input [2b] Signal output CAN-BUS connections: [GND]Earth [CANL]CAN low [CANH]CAN high [+12V]12V connection Note for output N, 57: Maximum permissible load: 150 W resistive * 5 A starting current * 3 A breaking current In the event of larger loads a suitable relay must be installed (not included in standard delivery). 8 Multi Box HP 10 6 720 804 408 (2012/11)

Electrical connections 8.2.1 Connection Hydrolight/Hydrocomfort module 6 1 2 5 3 4 6 720 801 399-15.2I Fig. 9 Connection to the main PCB in Hydrolight/Hydrocomfort module [1] Control panel in Hydrolight/Hydrocomfort module [2] Interface board [3] Main PCB (IOB-A) [4] Accessories board (IOB-B) [5] CAN-BUS signal, connected to Multi Box [6] Multi Box HP 10 CAN-BUS connections: [GND]Earth [CANL]CAN low [CANH]CAN high [+12V]12V connection Multi Box HP 10 6 720 804 408 (2012/11) 9

Electrical connections 8.2.2 Address selection general fault alarm 6 720 801 399-03.1I Fig. 10 Address and program selection Address selection A=0. Program selection P=2. 10 Multi Box HP 10 6 720 804 408 (2012/11)

Electrical connections 8.3 Wiring diagram Multi Box HP 10 mixed circuit 2 1 2 3 4 6 720 803 881-02.2I Fig. 11 Wiring diagram, Hydrolight/Hydrocomfort module with mixed circuit 2 [Solid line = factory connected] 8.3.1 Mixing valve, heating circuit 2 (E12.Q11) open/closed [Dotted line = connected at installation] The mixing valve E12.Q11 is opened by the signal at connection point [1] No Term if E12.TT is connected, Term if last component in the 51 and closed by the signal at connection point 52 at the terminal J6 ( CAN-BUS chain Fig 12). [2] Program selection [3] No Term IOB-A in internal unit of heat pump [4] Mains power supply [E12.TT.P1] Room temperature sensor, LED [E12.TT.T5] Room temperature sensor, heating circuit 2 1 [E12.T1] Flow temperature sensor, heating circuit 2 [E12.B12] External input 1 [E12.B11] External input 2 [E31.RM2.TM1-5] Dew point alarm (non functional) [E31.Q11] Signal output, cooling potential free (non functional) 2 [E12.G1] Heating circuit pump, heating circuit 2 6 720 648 125-39.1I [E41.G6] DHW circulation pump, domestic hot water [E12.Q11] Mixing valve, heating circuit 2 [E12.TT] LCD room temperature controller, heating circuit 2 Fig. 12 J6 connecting terminal Note for output N, 57: Maximum permissible load: 150 W resistive * 5 A starting current * 3 A breaking current In the event of larger loads a suitable relay must be installed (not included in standard delivery). [1] Mixing valve, closing signal [2] Mixing valve, opening signal [E12.Q11]Mixing valve Multi Box HP 10 6 720 804 408 (2012/11) 11

Electrical connections 8.3.2 Wiring diagram Multi Box HP 10 mixed circuit 2 with 230 V output N, 57 1 2 3 4 6 720 803 881-05.1I Fig. 13 Wiring diagram, Hydrolight/Hydrocomfort module with mixed circuit 2 with 230 V output N, 57 [Solid line = factory connected] [Dotted line = connected at installation] [1] No Term if E12.TT is connected, Term if last component in the CAN-BUS chain [2] Program selection [3] No Term IOB-A in internal unit of heat pump [4] Mains power supply [E12.TT.P1] Room temperature sensor, LED [E12.TT.T5] Room temperature sensor, heating circuit 2 [E12.T1] Flow temperature sensor, heating circuit 2 [E12.B12] External input 1 [E12.B11] External input 2 [E31.RM2.TM1-5] Dew point alarm (non functional) [E12.G1] Heating circuit pump, heating circuit 2 [E41.G6] DHW circulation pump, domestic hot water [E12.Q11] Mixing valve, heating circuit 2 [E12.TT] LCD room temperature controller, heating circuit 2 Note for output N, 57: 230 V if jumper pin 55 and 56 inserted. Maximum permissible load: 150 W resistive * 5 A starting current * 3 A breaking current In the event of larger loads a suitable relay must be installed (not included in standard delivery). 12 Multi Box HP 10 6 720 804 408 (2012/11)

Electrical connections 8.3.3 Connection Hydrolight/Hydrocomfort module 5 1 4 2 3 6 720 803 881-03.1I Fig. 14 Connection to the main PCB in Hydrolight/Hydrocomfort module [1] Control panel in Hydrolight/Hydrocomfort module [2] Interface board [3] Main PCB (IOB-A) [4] CAN-BUS signal, connected to Multi Box [5] Multi Box HP 10 (IOB-B) CAN-BUS connections: [GND]Earth [CANL]CAN low [CANH]CAN high [+12V]12V connection Multi Box HP 10 6 720 804 408 (2012/11) 13

Electrical connections 8.3.4 Address selection, mixed circuit 2 9 6 720 801 881-04.1I Fig. 15 Address and program selection Address selection A=0. Program selection P=9. 14 Multi Box HP 10 6 720 804 408 (2012/11)

Notes Multi Box HP 10 6 720 804 408 (2012/11) 15

Bosch Thermotechnik GmbH Sophienstrasse 30-32 D-35576 Wetzlar www.bosch-thermotechnology.com