set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

Similar documents
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Advance Release September 2009

Centeral Station Air Handling Unit

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Modular Supply Make-Up Air Unit

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

EHH SERIES DRAW THROUGH FAN COILS CFM

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

DIVISION 15 MECHANICAL

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SECTION AIR DUCT ACCESSORIES

LOW STATIC HYDRONIC DUCTED UNIT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

KOMFORT EC DB Suspended heat recovery air handling units

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Direct Fired Heater Model AD Specification

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Series 2 FS 100 HM Q S AH D on innovative. a full green. meeting. line features. Page No Introduction a high unit is. Air Handling Units

DESIGN GUIDELINES SECTION HVAC

Modular Heating & Ventilating Unit Model IGX-HV

50TM COMBINATION HEATING/COOLING UNITS

Double Skin Casing Air Handling Units

39G Air Handling Unit

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

The ultimate in air handling units: directly and indirectly fired

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

AIR HANDLING UNITS. Revision AG 16-07

The ultimate fresh air solution.

VERTICAL FAN COIL UNITS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

SECTION AIR COILS

SSL & SBS Engineering Guide

SECTION CONVECTION HEATING AND COOLING UNITS

Air Handling Units. T F E.

SECTION AIR HANDLING UNIT

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

The ultimate in air handling units: directly and indirectly fired

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Centrifugal Fans, Non-Overloading, Backward Inclined

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

50TM TFF COMBINATION HEATING/COOLING UNITS

Product Specifications. Vertical Floor Consoles By First Co.

SECTION FAN COIL UNITS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

HEATING & COOLING COIL PRODUCTS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Portable Vertical Air-Conditioning and Heating Systems

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

SKYPAK II, 3 Ton Series, gives you a

SECTION (15833) - HVAC POWER VENTILATORS

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

C. Samples for Initial Selection: For units with factory-applied color finishes.

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

WALL-MOUNT HEAT PUMPS - (60HZ)

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Direct Gas-Fired Make-Up Air

EMI ENGINEERING SUBMITTAL

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

The ultimate in air handling units: directly and indirectly fired

Transcription:

1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto reset type) complete with insulated plunum, flexible connection to plunum,support with vibration isolator and all required works. The unit shall be complet with insulated and painted drain pan and a factory fitted frame, with filter media, installed with direct driven forward curved centrifugal fans and 3 speed motor ensures quiet operation, flare fittings - easy & quick installation, standard copper tube aluminium fins (Cu/Al) evaporator coil for maximum heat transfer, carrir lanced sine wave fin pattern to high EER performance, factory supplied expansion devices, accurator and units shall be manufactured as left-hand side (in the direction of air flow) piping connection as standard. set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1.2 complete with all necessary fittings,supports and accessories. Dia. 20mm ml 17 1

1.3 Duct work & Accessories Supply,install,test and commission galvanized steel duct work all as shown on the drawing. Galvanized steel thickness shall be used in accordance with SMACNA standards and/or EBCS-11 & technical specification. Price shall also include vanes, fixing and clamping accessories necessary for proper functioning of air distribution system. a) Internal & external supply & return duct work Kg 283 b) dia.300mm flexible duct ml 32 Volume Damper Supply, fix, test and commission volume dampers of Frame: 1.2mm thick galvanized steel sheet, Frame size:125mm depth and standard flange height of 25mm, Blade: double skinned high quality extruded aluminium aerofoil profiles, Bearing pins: electro plated square steel rod of size 12.7mm X 12.7mm, Bushings: self oiling nylon bushings of internal squre size,bearing pin connecting quadrant: electro plated square steel rod of size 12.7 X 12.7 mm, Blade linkage: steel / aluminium linkage, Blade stopper: 20 mm X20 mm aluminium angle as where shown on the drawings. Price shall include all 1.4 the necessary accessories and connecting pieces. No /On supply & exhaust air branch duct./ 8 size: 200x150mm 1.5 Fire Damper Supply, fix, test and commission Fire damper of approved quality as where shown on the drawings. Price shall include all the necessary accessories and connecting pieces. Dampers shall meet the requirements of NFPA 90A and SMACNA rated dampers for use as Fire barriers for 1-1/2 hr. / 3 hrs fire rating. No 1 1.6 size: 300x250mm Supply & Return Air Linear Diffuser Made of high quality extruded aluminum profiled construction complete with insulated plunum and all required accessories. a ) Supply air linear diffuser : - Flow rate= 165lps size : W=15cm, L=100cm a ) Return air linear diffuser : - Flow rate=165lps size : W=15cm, L=100cm 2 No 8 No 8

Heat Recovery Unit Supply, fix, test and commission heat recovery unit of approved quality as where shown on the drawings. Price shall include all the necessary accessories and connecting pieces. 1.7 The supply and extract ventilation unit shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule.the combined supply and extract with heat recovery unit, shall supply filtered fresh air the room and vitiated air shall be extracted from the same room. The supply air shall be precooled by the cold extract air via the integrated counter-flow heat exchanger element. A summer bypass shall be included (excludes 90S) that shall allow fresh air to bypass the heat exchanger, when the incoming air temperature is at or above the designated set point. No 1 - Flow rate = 340 lps - Static Pressure = 200Pa. Dual split DX-Air conditioning unit : a) Outdoor Unit 2. Eighth Floor 2.1 i) For Director room on eighth floor /OU-02/ - Cooling capacity = 10.74 Kw set 1 3

i) For Director room on eighth floor/iu-02/, - Cooling capacity = 5.59Kw (2 pieces to 1 outdoor unit) 2.2 complete with all necessary fittings,supports and accessories. ml 45 Dia. 20mm Single split DX-Air conditioning unit : a) Out Door Unit 3. Seventh Floor i) For Deputy Director room on seventh floor/ou-03/ - Cooling capacity =7.035Kw 3.1 set 1 4

i) For Deputy Director room on seventh floor/iu-03/, - Cooling capacity = 7.035Kw (1 piece to 1 outdoor unit) 5

complete with all necessary fittings,supports and accessories. 3.2 ml 40 Dia. 20mm Dual split DX-Air conditioning unit : a) Out Door Unit. i) For Meeting room on seventh floor/ou-04/ - Cooling capacity =10.74Kw 3.3 set 1 i) For Meeting room on seventh floor /IU-04/- Cooling capacity = 5.59Kw (2 pieces to 1 outdoor unit) 6

4. AIR CONDITIONING SYSTEM (Sixth Floor) Multi split DX-Air conditioning unit : a) Outdoor Unit i) For IT & Server room on sixth floor/ou-05/ - Cooling capacity =13.20Kw 4.1 set 1 i) For IT & Server room on sixth floor/iu-05/, - Cooling capacity = 5.56Kw (2 pieces to 1 outdoor unit) 4.2 complete with all necessary fittings,supports and accessories. ml 25 Dia. 20mm Dual split DX-Air conditioning unit : a) Out Door Unit 5. Fifth Floor 7

i) For Meeting room on fifth floor/ou-06/ - Cooling capacity =10.74Kw 5.1 i) For meeting room on fifth floor/iu-06/, - Cooling capacity = 5.59Kw (2 pieces to 1 outdoor unit) a) Outdoor Unit set 1 8

i) For IT & Server room on fifth floor /OU-07/ - Cooling capacity =13.20Kw 9

set 1 i) For IT & Server room on fifth floor /IU-07/, - Cooling capacity = 5.56Kw (2 pieces to 1 outdoor unit) 5.2 complete with all necessary fittings,supports and accessories. ml Dia. 20mm 25 6. Fourth Floor Single split DX-Air conditioning unit : a) Outdoor Unit i) For UNCDF room on fourth floor/ou-08/ - Cooling capacity =7.035Kw 6.1 set 1 10

i) For UNCDF room on fourth floor/iu-08/, - Cooling capacity = 7.035Kw(1 piece to 1 outdoor unit) 11

6.2 complete with all necessary fittings,supports and accessories. ml 42 Dia. 20mm Single split DX-Air conditioning unit : a) Out Door Unit 7. Ground Floor i) For CCTV room on ground floor/ou-09/ - Cooling capacity =6.4Kw 7.1 No 1 i) For CCTV room on ground floor/iu-09/, - Cooling capacity = 6.4Kw(1 piece to 1 outdoor unit) 7.2 complete with all necessary fittings,supports and accessories. ml 7 Dia. 20mm 12

8.1 8. Toilet Ventilation System (Ground to Ninth floors) Exhaust Air Fan /Twin-Fan/ Supply, fix, test and commision toilets exhaust twin fans of approved quality, complete with all connecting pieces, controls and all accessories. The unit shall be designed to garante uninterupted air exhaust this achived by means of a fan in duty and another one stand -by waiting to start automatically in case of break down of the first fan. Duty and stand-by fans shall be manually or automatically exchanged. a) i) Twin Fan Q=525lps H=250Pa. Set 1 8.2 Duct work & Accessories Supply,install,test and commission galvanized steel sheet thickness shall be 0.6mm and comply with provisions of SMACNA standard and EBCS-11. Price shall also include fixing and clamping accessories. Kg 440 a) Exhaust duct work 8.3 Volume Damper Supply, fix, test and commission volume dampers of approved quality as where shown on the drawings. Price shall include all the necessary accessories and connecting pieces. /On supply & exhaust air branch duct./ No 21 8.4 size: 100x100mm Exhaust Air Grill Made of high quality extruded aluminum profiled construction with the advantage of corrosion resistance and rigidity. No 21 i.) size: 150x150mm 13