PRODUCT RANGE RESIDENTIAL. Hot water heating, dehumidification, residential ventilation

Similar documents
PRODUCT RANGE DEHUMIDIFIERS. For domestic and commercial garages and car storage facilities

VENTILATION WITH HEAT RECOVERY

PRODUCT RANGE POOL HEATING AND COOLING. Swimming pool heat pumps, heat cool systems and water chillers

HCV 4 - HCV 5 - HCH 5 - HCH 8

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

CDP 40 SWIMMING POOL DEHUMIDIFIER

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

TECHNICAL INFORMATION HCC 2 Home ventilation unit for suspended ceiling

SWIMMING POOL AIR MANAGEMENT DanX

2018/19 PRODUCT CATALOGUE

TECHNICAL INFORMATION HCC 2 Home ventilation unit for suspended ceiling

PRODUCT RANGE DEHUMIDIFIERS. For water damage and restoration

DEMAND-CONTROLLED HOME VENTILATION

PRODUCT RANGE 2018 COMMERCIAL/INDUSTRIAL. Heating, cooling, dehumidification, ventilation

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

Technical Information HXV - HRV Ventilation

MOBILE HEATING AND COOLING

Technical Information HCV - HCH Demand-controlled home ventilation

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

DEHUMIDIFIERS & VENTILATORS

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Applications Damage service Building drying Water works Dry storing FEATURES

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

Heat Cool system. Take control of your pool heating and cooling with the Calorex 34 and new Pro-Pac ranges

DOMESTIC DEHUMIDIFIERS FLIPPERDRY

PRODUCT CATALOGUE MOBILE. Heating, drying, cooling, ventilation

Roof top SPACE RPC 450Z R407C M011

RAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Pool dehumidification for comfort and wellness

GHE Dehumidifiers for radiant cooling systems with heat recovery

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

KOMFORT EC DB Suspended heat recovery air handling units

COTES ALL-ROUND THE C30 RANGE

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Condensation drying for industry and trade

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

FH - GH Dehumidifiers for radiant cooling systems

CALOREX TECHNICAL GUIDE PRO-PAC H HY. Air/water heat pumps

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

The Sentinel Kinetic Horizontal Range

HEAT PUMP. Dongguan New Times New Energy Science & Technology Co., Ltd.

EDPAC International Close Control Air Conditioning Products E

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

TOSHIBA AIR CONDITIONING

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

Heat Recovery Air Handling Units

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

2018 PRODUCT CATALOGUE TO HEAT TO COOL TO DRY TO VENTILATE

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Roof top SPACE RPC 315Z R407C MA00

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

NEXT DL NEXT DL. rcgroupairconditioning

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Healthy, comfortable and energy-efficient ventilation

PYXIS U PYXIS U. rcgroupairconditioning

Industrial cooling systems LT

HIWARM COMPACT kw

pyxis pyxisa NEW rcgroupairconditioning

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

TopMaster Air Handling unit. Technical data

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Calorifier/heat pump CombiVal WPE/WPER (300)

Home Solutions for Residential Ventilation

Condensing Units CUS 15-60

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

PRINCIPLE FOR DEHUMIDIFYING CRAWL SPACES

Transcription:

PRODUCT RNGE RESIDENTIL Hot water heating, dehumidification, residential ventilation

BOUT THE DNTHERM GROUP Control your climate The Dantherm Group is a leading provider of climate control products and solutions. The group companies have more than 60 years of experience in designing and manufacturing high quality and energy efficient equipment for heating, cooling, drying and ventilation for a wide range of mobile and fixed applications. Every year Dantherm Group uses significant resources on product development to stay in the forefront and are constantly adapting the products to changing market demands and legislation. The Dantherm Group has strong brands with well-established market positions in the mobile, pool, commercial/industrial and residential markets. Dantherm Group customers benefit from our comprehensive knowledge base and the experience and expertise that we have gained from more than three million climate control products and solutions sold worldwide. Global reach The Dantherm Group is headquartered in Skive, Denmark and has companies in Norway, Sweden, United Kingdom, Germany, France, Switzerland, Italy, Spain, Poland, Russia, China and United rab Emirates and a global distribution network. In 2016 the Dantherm Group was acquired by the Swedish equity fund Procuritas Capital Investors V LP a strong owner with the ambition to continue the development and growth of the company. 2

RESIDENTIL INDEX RESIDENTIL TO COOL ir cooling and water heating Cooling with heat recovery... 4 Water cooling Homes and offices... 5 TO DRY Dehumidifiers Laundry dryers... 6 Wall mounted... 7 Wall mounted/floor standing... 11 TO VENTILTE Ceiling mounted with heat recovery... 13 Cupboard and wall mounted with heat recovery... 14 Cupboard and wall mounted with heat recovery... 15 ttic mounted with heat recovery... 20 TO CONTROL Residential ventilation controllers Controllers... 23 3

IR COOLING ND WTER HETING COOLING WITH HET RECOVERY Options W 450SC Hot gas defrost Stainless steel case High temperature version for heating water to 65 C Heat reject unit (required when air cooling has priority over water heating) ir filter Cooling down to 7 C (-5 C with hot gas defrost option) Rugged PVC coated galvanised steel case Wall mounted Easy to install and connect W 450SC produces up to 3300 litres of hot water per day at 50 C enough for 660 typical covers per day W 250SC produces up to 2400 litres of hot water per day at 50 C enough for 430 typical covers per day Home hot water heating Beer and wine cellars Waste heat recovery from boiler rooms with water pre-heat capacity Launderettes Spas and clubs Campsites and caravan parks Specifications Units W 250SC W 450SC ir temperature range Water temperature range Max. water flow Min. water flow Max. water resistance Min. water resistance Water connections ir flow External resistance Fan drive Sound level @ 3m Power supply Supply LR FL Power consumed Product size (h x w x d) Weight * -5 with hot gas defrost 4 C C l/min l/min mhd mhd m3/h mmwg db() V/Hz mm kg 7*-36 10-50 14 12 3.5 2.8 22mm pipe stub 1019 0 Direct 57 220-240/1ph/50 13 13 5.5 0.9 665 x 780 x 340 60 7*-36 10-50 22 18 4.8 3.5 22mm pipe stub 1698 0 Direct 59 220-240/1ph/50 20 20 11 1.8 665 x 1245 x 340 95

WTER COOLING HOMES ND OFFICES Options vailable in 60Hz W 1234BC Domestic sizes giving up to 900 litres per hour of cold water production Fully packaged, robust and weatherproof construction Quiet operation Purpose-built for operation in the Gulf region Certified cupronickel WRS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system Non ozone depleting refrigerant (R134) TO COOL Homes and villas Plunge pools * WRS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges. Specifications Units W 634CL W 634CH W 1234BC ir temperature range Water temperature range Output @ 32 C water Input @ 32 C water Output @ 10 C water Input @ 10 C water Nominal cold water production Min./max. tank size Electrical input Power supply Max. supply fuse Starting current Water flow ±10% Flow resistance Connections Nominal air flow Fan external resistance (standard) Fan Sound pressure level @ 3m Product size (w x d x h) Weight C C l/h l V/Hz l/min mhd inch m³/h Pa Type db() mm kg Cooling output and input calculated at +45 C/50% RH ambient air 0-55 10-40 5.5 1.9 2.8 1.4 500 60/500 1.9 220-240/1ph/50 13 32 33 2.1 ¾ BSPM 1500 50 1 x Centrifugal 63 820 x 702 x 762 111 10-55 10-40 5.5 1.9 2.8 1.4 500 60/500 1.9 220-240/1ph/50 13 32 33 2.1 ¾ BSPM 1500 50 1 x Centrifugal 63 820 x 702 x 762 111 10-55 10-40 9.8 3.2 5.9 2.5 900 110/1000 3.2 400/3ph/50 16 48 33 2.1 ¾ BSPM 3000 50 1 x Centrifugal 65 1060 x 705 x 807 157 5

DEHUMIDIFIERS LUNDRY DRYERS Easy to use electronic edry (Languages: DE/IT/FR/E) Operation mode (space drying/laundry drying) Display actual humidity Setting target humidity Program selection (Timer, Turbo-drying) Drying utomatic WT 230 WT 240 WT 250 WT 280 Case made of galvanized steel, hood made of easy to clean plastic, service-friendly housing construction Space-saving wall mounting Blue-Dry -Technology for particularly energy-saving operation even at low humidities and temperatures Fully hermetic rotary compressor Energy-efficient EC-radial fan Maintenance-friendly refrigerant circuit with service connector Condenser and evaporator made of copper tubes with aluminium fins On-demand hot gas defrost system for optimum operation in a cool places Laundry drying Basements and cellars Living rooms Warehouses Preservation Sewage treatment, waterworks Specifications Units WT 230 WT 240 WT 250 WT 280 Capacity (30 C/80% RH) l/24h 35.5 36.5 57.1 79.2 ir flow m 3 /h 750 830 870 920 Energy consumption per kg laundry h/kg 0.25 0.25 0.27 0.30 Drying time h/min 4/55 5/35 5/23 5/13 Operating temperature range C 3-32 3-32 3-32 3-32 Operating humidity range % 35-95 35-95 35-95 35-95 Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50 230/1ph/50 Sound level db() 61 61 60 60 Condensate drain mm 15 x 2 15 x 2 15 x 2 15 x 2 Product size (h x w x d) mm 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345 Weight kg 40 40 42 43 6

DEHUMIDIFIERS WLL MOUNTED CDF 10 CDF 10 with water tank Built into a strong and robust powder coated hot galvanized sheet metal cabinet Evaporator and condenser coils are epoxy-coated for high corrosion resistance The condensate outlet is located at the bottom of the CDF dehumidifier. The outlet stub can be connected to a water hose. Easy accessible washable air filters from front cover Reciprocating compressor xial fan Electronic control and user-friendly display panel ctive, demand-controlled defrosting vailable in white and grey Optional accessories Room hygrostat Water tank, grey or white Basements and cellars Garages and car storage rchives and museums Churches Changing rooms TO DRY Specifications Units CDF 10 Operating temperature range Operating humidity range Dehumidification @ 30 C/60% RH ir flow Power supply Max. power consumption Sound pressure level @ 1m Refrigerant Water container capacity Product size (h x w x d) Weight C % RH l/24h m 3 /h V/Hz db() l mm kg 3-30 40-100 7.5 220 230/1ph/50 0.3 46 R134a 5.5 600 x 535 x 240 28 7

DEHUMIDIFIERS WLL MOUNTED DH 15 Compact design for installation in small areas Self contained with fully automatic operation Integral humidistat Tamper proof controls Epoxy polyester painted zintec steel cabinet Hot gas defrost for low temperature operation ir filter Options Through the wall version Basements and cellars Stairwells Garages and car storage Libraries Drying rooms Store rooms Unheated premises Specifications Units DH 15X Operating temperature range Dehumidification @ 30 C/60% RH Heat recovered to air @ 30 C/60% RH ir flow External static pressure Sound pressure level @ 3m Refrigerant Power supply Nominal power consumption FL Maximum supply fuse LR (compressor start) Product size (w x d x h) Weight Condensate drain size (flexible plastic hose) C l/24h m 3 /h Pa db() V/Hz mm kg mm ID 0-35 15 0.9 225 0 53 R407c 230/1ph/50 0.43 3.8 10 18 825 x 363 x 320 33 10 8

DEHUMIDIFIERS WLL MOUNTED DH 30 Self contained with fully automatic operation Integral humidistat Polyester coated evaporator and condenser Plastisol coated galvanised steel cabinet Hot gas defrost for low temperature operation Quiet centrifugal fans Remote humidistat and on/off function Options Through the wall version Electric air heater LPHW air heater Floor stand kit Drying rooms Modular buildings Electrical sub-stations Sports clubs and changing rooms Warehousing and storage Museums, libraries and galleries Garages Specifications Units DH 30X DH 30XP Operating temperature range Dehumidification @ 30 C/60% RH Heat recovered to air @ 30 C/60% RH ir flow External static pressure Sound pressure level @ 3m Refrigerant Power supply Dehumidifier power input FL Maximum supply fuse LR (compressor start) Heater type Heat output Flow rate Product size (w x d x h) Weight Condensate drain size (flexible plastic hose) C l/24h m 3 /h Pa db() V/Hz l/min mm kg mm ID 0-35 30 1.9 700 0 52 R407c 230/1ph/50 0.75 4.4 10 15.8 Optional LPHW 3.0 5.0 782 x 270 x 648 40 16 0-35 30 1.9 700 0 52 R407c 230/1ph/50 0.75 12.7 20 15.8 Standard Electric 2.0-782 x 270 x 648 40 16 TO DRY 9

DEHUMIDIFIERS WLL MOUNTED DH 60 Self contained with fully automatic operation Integral humidistat Polyester coated evaporator and condenser Plastisol coated galvanised steel cabinet Hot gas defrost for low temperature operation Quiet centrifugal fans Remote humidistat and on/off function Options Through the wall version Electric air heater LPHW air heater Floor stand kit rchives and museums Churches Changing rooms Waterworks Garages and car storage Specifications Units DH 60X DH 60XP Operating temperature range Dehumidification @ 30 C/60% RH Heat recovered to air @ 30 C/60% RH ir flow External static pressure Sound pressure level @ 3m Refrigerant Power supply Dehumidifier power input FL Maximum supply fuse LR (compressor start) Heater type Heat output Flow rate Product size (w x d x h) Weight Condensate drain size (flexible plastic hose) C l/24h m 3 /h Pa db() V/Hz l/min mm kg mm ID 0-35 60 3.5 1280 0 54 R407c 230/1ph/50 1.2 7.5 13 30 Optional LPHW 5.0 5.0 1247 x 270 x 648 60 16 0-35 60 3.5 1280 0 54 R407c 230/1ph/50 1.2 24.2 32 30 Standard Electric 4.0-1247 x 270 x 648 60 16 10

DEHUMIDIFIERS WLL MOUNTED/FLOOR STNDING Optional accessories Wireless remote control DRC1 Floor mounting kit Water heating coils Control valve for water heating coils Electric heating coils Exhaust fans Diodes BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors Defrosting CDF 50 Built into a strong and robust powder coated hot galvanized sheet metal cabinet Evaporator and condenser coils are epoxy-coated for high corrosion resistance Fixed to the wall by means of a wall mounting strip supplied with the unit Condensate outlet located at the bottom. Outlet stub can be connected to a ¾" hose Outside connection to mains Controls Built in electronic hygrostat and thermostat Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories) 0-VOLT connection for alarm 230 V for control valve, exhaust fan and pump/boiler RS 485 gate for BMS (Modbus) ctive, demand-controlled defrosting is incorporated in the electronic control. Service For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding. rchives and museums Churches Changing rooms Waterworks Garages and car storage TO DRY Specifications Units CDF 40 CDF 50 CDF 70 Operating temperature range Operating humidity range Dehumidification @ 30 C/60% RH ir flow Power supply Max. power consumption Sound pressure level @ 1m Refrigerant Filter Product size (w x d x h) Weight Condensate drain size (stub) C % RH l/24h m 3 /h V/Hz db() mm kg inch 3-32 40-100 30 400 230/1ph/50 0.78 46 R407c G3 PPI 15 1010 x 327.8 x 699.9 56.5 ¾ 3-32 40-100 53 680 230/1ph/50 1.37 47 R407c G3 PPI 15 1060 x 327.8 x 699.9 65 ¾ 3-32 40-100 55 900 230/1ph/50 1.5 50 R407c G3 PPI 15 1495 x 327.8 x 699.9 75.5 ¾ 11

ENERGY-EFFICIENT VENTILTION SOLUTIONS BLNCED WHOLE-HOUSE MECHNICL VENTILTION WITH HET RECOVERY FOR PRIVTE HOMES. 12

RESIDENTIL VENTILTION CEILING MOUNTED WITH HET RECOVERY HCC 2 PL Optional accessories Dantherm pp Wireless remote control (HRC 3) Wired control (HCP 10) Dantherm PC Tool VOC air quality sensor Private houses Villas partments Hygrostat CO₂ sensor ccessory control HC 2 Electric pre-heating coils for installation in fresh air duct fterheaters High efficiency heat recovery up to 94% EC fan motors with low energy consumption (low SPI) Only 300mm installation headroom height is required Time controlled ventilation level, based on 11 different built in pre-programmed week programs. This reduces power consumption in periods with low ventilation demands Summer cooling mode Fireplace mode, creating a momentary inside overpressure, to enhance chimney functionality Easy-to-install and commissioning solution with built in air measure ports, for easy balancing with PC-Tool Electronically left/right fan direction switching, allowing same unit type to adapt any physical installation requirements, regardless of ceiling and wall selection TCP/IP ModBus connection, for inter-operation with Building Management System Specifications Units HCC 2 Max. air flow (max. @ 100 Pa) m 3 /h 200 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Operating range DIBt m 3 /h 70 to 140 Operating range Passivhaus m 3 /h 70 to 140 Efficiency DIBt % 93.8 Efficiency Passivhaus % 93 Installation surrounding temperature C +12 - +40 Maximum humidity in extract air @ 25 C RH% 65 Outdoor temperature (without preheating installed) C -12 2 - +50 Outdoor temperature (with preheating installed) C -25 - +50 Cabinet Product size (w x h x d without bracket) mm 600 x 279 x 1122 Duct connections ø mm 125 - female Weight kg 34 Fire classification of the unit EN 13501 class E Drainage hose included ø/length 1/2" 2m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 127 1 Requires an optional Energy Efficiency Class + kit (including VOC sensor and RH% sensor). 2 Preheating is recommended when outside temperatures are below -5 C to ensure balanced operation of the home ventilation unit. 13 TO VENTILTE

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 300 Optional accessories Dantherm pp Wireless remote control (HRC 3) Wired control (HCP 10) Dantherm PC Tool VOC air quality sensor Private houses Villas partments Hygrostat ccessory control HC 2 CO₂ sensor Electric heating coil for installation in the unit cabinet fterheaters Demand-controlled ventilation with integrated humidity sensor This reduces power consumption at times with low ventilation demands Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality High efficiency heat recovery EC fan motors with extremely low energy consumption (low SPI) Easy-to-install and commission solution with built -in air pressure spigots for easy calibration Highly customizable units, by adding a high variety of internal as well as external accessories HCV 300 models takes up only as little space as a 60x60cm cupboard Specifications Units HCV 300 Max. air flow (max. @ 100 Pa) m 3 /h 180 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate Efficiency EN13141-7 dry (h SUP ) % 86 Installation surrounding temperature C 12-50 Outdoor temperature without preheater installed (t OD ) C -12 - +50 Outdoor temperature with preheater installed C -25 - +50 Cabinet Product size (w x h x d without bracket) mm 600 x 1000 x 430 Ducts Ø mm 125 - female Weight kg 36.5 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) "/m ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 170 14

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 400 Optional accessories Dantherm pp Wireless remote control (HRC 3) Wired control (HCP 10) Dantherm PC Tool VOC air quality sensor Private houses Villas partments Hygrostat CO₂ sensor ccessory control HC 2 Electric heating coil for installation in the unit cabinet fterheaters Demand-controlled ventilation with integrated humidity sensor This reduces power consumption at times with low ventilation demands Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality High efficiency heat recovery EC fan motors with extremely low energy consumption (low SPI) Easy-to-install and commission solution with built -in air pressure spigots for easy calibration Highly customizable units, by adding a high variety of internal as well as external accessories HCV 400 models takes up only as little space as a 60x60cm cupboard Specifications Units HCV 400 Max. air flow (max. @ 100 Pa) m 3 /h 240 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 86 Installation surrounding temperature C 12-50 Outdoor temperature without preheater installed (t OD ) C -12 - +50 Outdoor temperature with preheater installed C -25 - +50 Cabinet Product size (w x h x d without bracket) mm 540 x 1050 x 549 Ducts Ø mm 160 - female Weight kg 42.5 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) "/m ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 170 1 Requires an optional Energy Efficiency Class + kit (including VOC sensor and RH% sensor). 15 TO VENTILTE

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 500 Optional accessories Dantherm pp Wireless remote control (HRC 3) Wired control (HCP 10) Dantherm PC Tool VOC air quality sensor Private houses Villas partments Hygrostat CO₂ sensor ccessory control HC 2 Electric heating coil for installation in the unit cabinet fterheaters Demand-controlled ventilation with integrated humidity sensor This reduces power consumption at times with low ventilation demands Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality High efficiency heat recovery EC fan motors with extremely low energy consumption (low SPI) Easy-to-install and commission solution with built -in air pressure spigots for easy calibration Highly customizable units, by adding a high variety of internal as well as external accessories Specifications Units HCV 500 Max. air flow (max. @ 100 Pa) m 3 /h 300 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 86 Installation surrounding temperature C 12-50 Outdoor temperature without preheater installed (t OD ) C -12 - +50 Outdoor temperature with preheater installed C -25 - +50 Cabinet Product size (w x h x d without bracket) mm 700 x 1050 x 605 Ducts Ø mm 160 - female Weight kg 49.5 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) "/m ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 170 1 Requires an optional Energy Efficiency Class + kit (including VOC sensor and RH% sensor). 16

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 700 Optional accessories Dantherm pp Wireless remote control (HRC 3) Wired control (HCP 10) Dantherm PC Tool VOC air quality sensor Private houses Villas Hygrostat CO₂ sensor ccessory control HC 2 Electric heating coil for installation in the unit cabinet fterheaters Demand-controlled ventilation with integrated humidity sensor This reduces power consumption at times with low ventilation demands Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality High efficiency heat recovery EC fan motors with extremely low energy consumption (low SPI) Easy-to-install and commission solution with built -in air pressure spigots for easy calibration Highly customizable units, by adding a high variety of internal as well as external accessories Specifications Units HCV 700 Max. air flow (max. @ 100 Pa) m 3 /h 450 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 85 Installation surrounding temperature C 12-50 Outdoor temperature without preheater installed (t OD ) C -12 - +50 Outdoor temperature with preheater installed C -25 - +50 Cabinet Product size (w x h x d without bracket) mm 700 x 1050 x 750 Ducts Ø mm 200 - female Weight kg 64.0 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) "/m ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 234 1 + can be obtained with optional accessory kit. 17 TO VENTILTE

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 4 Optional accessories Wireless remote control (HRC 2) ccessory control HC 1 Hygrostat CO₂ sensor Pre- and after-heating coils Demand-controlled ventilation with integrated humidity sensor High efficiency heat recovery EC motors with extremely low energy consumption (low SPI) Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit HCV 4 is suitable for installation in 60 x 60cm cupboards Integrated control panel HCP 4 in front Private houses Villas partments Specifications Units HCV 4 Max. air flow (max. @ 100 Pa) m 3 /h 275 Bypass Yes, manual Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 89.5 Surrounding temperature where the unit is installed C 10-50 Operational temperature range without pre-heating C -13 2 - +50 Operational temperature range with pre-heating C -30 - +50 Cabinet Product size (h x w x d standard mounting rail/rail for plan mounting) mm 1005 x 530 x 434/419 Duct connection mm 125 Weight kg 32 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 88 1 Requires an Energy Efficiency Class + kit (including CO 2 sensor and HC 1 accessory control). 2 We recommend preheating at temperatures under -6 C to ensure a balanced operation. 18

RESIDENTIL VENTILTION CUPBORD ND WLL MOUNTED WITH HET RECOVERY HCV 5 Optional accessories Wireless remote control (HRC 2) ccessory control HC 1 Hygrostat CO₂ sensor Pre- and after-heating coils Demand-controlled ventilation with integrated humidity sensor High efficiency heat recovery EC motors with extremely low energy consumption (low SFP) Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit HCV 5 is suitable for installation instead of 60 x 60cm cupboards Integrated control panel HCP 4 in front Private houses Villas partments Specifications Units HCV 5 Max. air flow (max. @ 100 Pa) m 3 /h 375 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 88 Efficiency Passivhaus % 80 Surrounding temperature where the unit is installed C 10-50 Operational temperature range without pre-heating C -13 2 - +50 Operational temperature range with pre-heating C -30 - +50 Cabinet Product size (h x w x d(standard mounting rail/rail for plan mounting) mm 1055 x 590 x 584/569 Duct connection mm 160 Weight kg 32 Fire classification of the unit EN 13501 class E Drainage hose included (Ø/length) ¾" - 1m Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 154 1 Requires an Energy Efficiency Class + kit (including CO 2 sensor and HC 1 accessory control). 2 We recommend preheating at temperatures under -6 C to ensure a balanced operation. 19 TO VENTILTE

RESIDENTIL VENTILTION TTIC MOUNTED WITH HET RECOVERY Optional accessories Wireless remote control (HRC 2) ccessory control HC 1 Hygrostat CO₂ sensor Pre- and after-heating coils HCH 5 Demand-controlled ventilation with integrated humidity sensor High efficiency heat recovery EC motors with extremely low energy consumption (low SPI) Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit HCH models are suitable for installation on uninsulated attics Separate HCP 4 control panel included + 2m cable Private houses Villas partments Specifications Units HCH 5 Max. air flow (max. @ 100 Pa) m 3 /h 375 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 88 Efficiency Passivhaus % 81 Surrounding temperature where the unit is installed C -20 - +50 Operational temperature range without pre-heating C -13 2 - +50 Operational temperature range with pre-heating C -30 - +50 Cabinet Product size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 x 580 Duct connection mm 160 Weight kg 52 Fire classification of the unit EN 13501 class E Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 154 1 Requires an Energy Efficiency Class + kit (including CO 2 sensor and HC 1 accessory control). 2 We recommend preheating at temperatures under -6 C to ensure a balanced operation. 20

RESIDENTIL VENTILTION TTIC MOUNTED WITH HET RECOVERY Optional accessories Wireless remote control (HRC 2) ccessory control HC 1 Hygrostat CO₂ sensor Pre- and after-heating coils HCH 8 Demand-controlled ventilation with integrated humidity sensor High efficiency heat recovery EC motors with extremely low energy consumption (low SPI) Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit HCH models are suitable for installation on uninsulated attics Separate HCP 4 control panel included + 2m cable Private houses Villas partments Specifications Units HCH 8 Max. air flow (max. @ 100 Pa) m 3 /h 530 Bypass Yes, automatic Performance Energy consumption class (SEC-class), average climate /+ 1 Efficiency EN13141-7 dry (h SUP ) % 86 Efficiency Passivhaus % 83 Surrounding temperature where the unit is installed C -20 - +50 Operational temperature range without pre-heating C -13 2 - +50 Operational temperature range with pre-heating C -30 - +50 Cabinet Product size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 780 Duct connection mm 250 Weight kg 70 Fire classification of the unit EN 13501 class E Electrical Power supply V/Hz 230/1ph/50 Max. power consumption (without heater options fitted) W 246 1 Requires an Energy Efficiency Class + kit (including CO 2 sensor and HC 1 accessory control). 2 We recommend preheating at temperatures under -6 C to ensure a balanced operation. 21 21 TO VENTILTE

RESIDENTIL VENTILTION CONTROLLERS TO CONTROL DDITIONL CONTROL OPTIONS WITH SIMPLE CONTROL PNEL, DNTHERM PP OR N DVNCED WIRELESS REMOTE CONTROL. 22 22

RESIDENTIL VENTILTION CONTROLLERS CONTROLLERS Dantherm pp The Dantherm pp, which is available for ios and ndroid via the pp store and Google play, offers a user-friendly and intuitive way to control the residential ventilation unit. The pp is connected to the wifi router of the house. TO CONTROL Dantherm pp Demand control operation Manual operation Week program operation Night operation Manual bypass cooling Summer cooling Fireplace mode larms Settings menu Wireless remote control (HRC 2 & HRC 3) Wireless remote control Dantherm offers a wireless remote control, which can be mounted on the wall or placed on a shelf. The remote control is designed for the user, but also includes a special installer menu, allowing the installer to do extensive settings, without the use of the PC Tool. The remote control has an acoustic alarm that will sound when the filters need to be inspected or replaced. The user features are: Fan speed in manual mode. Select demand mode (requires RH and/or VOC sensors to be mounted) Select week mode and week program 1-11 Manually open bypass. It closes again automatically Enable fireplace boost mode. Seven minutes with overpressure inside the house for easy ignition of a fireplace Enable away mode in which the unit decreases permanently to speed 1 Enable night mode in which the unit decreases to speed 1. The time night mode can be adjusted Remaining filter period + adjustment of same Temperature readings in all four duct connections, including the remote control s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory) Setting time and date 23

RESIDENTIL VENTILTION CONTROLLERS CONTROLLERS Wired control (HCP 10) Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. lternatively Dantherm can supply a box to fix to the wall in an appropriate place. The HCP 10 wired control gives the user the following options: Wired control Manual control of air change (step 0-4) Control of air change with week program Demand controlled air change (if RH and VOC sensors are connected) Enable summer mode (only extract air) Enable manual bypass (requires an optional mechanical bypass to be mounted) Enable fireplace mode Reading and resetting of alarms, including filter alarm The wired HCP 10 control offers the possibility of adjusting the air volumes without using Dantherm s PC Tool. Dantherm PC Tool Kit (HPT 1) PC Tool Kit The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality. 24

RESIDENTIL VENTILTION CONTROLLERS CONTROLLERS Control panel (HCV 300, 400, 500, 700) The HCV units, has an built-in foil based control panel, with four buttons for controls, and nine LED feedback signals. TO CONTROL *ccessory Fan speed LED indication Bypass Short press - 6 hours bypass* Long press - Summer mode Warning / larm Red LED - larm Orange LED - Filter warning Long press - Filter reset Manual fan Short press - Fan speed Long press - Fireplace mode uto fan Short press - Week program Long press - Demand* Control panel (HCV 4, HCV 5, HCH 5, HCH 8) The drawing below shows the buttons, LEDs and sound outlets on the control panel which is included with the unit and the remote control which is an optional accessory. Status LED: Green = OK Yellow = change filter Red = system fault Nominal air volume Fan step 3 adjusted using potentiometers on rear of the control panel coustic alarm Manual bypass Summer mode utomatic demand control Fan speed (0)123 Manual control of fan speed Fan speed 01234 Fire place function Current fan speed Shown for 2 mins. after actuation 25

WHY CHOOSE OUR RESIDENTIL PRODUCTS CHOOSING THE BEST SOLUTION Unique Dantherm Group products for hot water heating, home ventilation, storage, drying and laundry drying for your home. DOMESTIC VENTILTION SOLUTIONS Balanced whole-house mechanical ventilation with heat recovery for private homes. PRESERVING YOUR PERSONL ITEMS Whether it is a classic car, wine collection, artwork or space drying our dehumidifiers will provide protection from humidity damage. CRETING HELTHY ENVIRONMENTS Improve your indoor air quality and recover heat with our low-energy and highly efficient ventilation solutions - for new-build or retrofit. SUSTINBLE HETING SOLUTIONS Hot water heat pumps provide a sustainable heating solution which, compared to fossil fuel or direct electric systems, will dramatically cut operating costs and carbon emission. REDUCE OPERTING COSTS We focus on developing energy saving units PROTECTING THE ENVIRONMENT Our development teams focus on reducing the carbon foot print by making our products as environmentally friendly as possible. USER ND MINTENNCE FRIENDLY Our products are easy to install, use and maintain. 26

Dantherm Ltd. Unit 12, Galliford Road Maldon CM9 4XD United Kingdom +44 (0)1621 856611 sales.uk@dantherm.com danthermgroup.co.uk