CTBUH Technical Paper

Similar documents
ASSESSING FIRE SAFETY PROVISIONS FOR SATISFYING GREEN OR SUSTAINABLE BUILDING DESIGN CRITERIA: PRELIMINARY SUGGESTIONS

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

ASPECTS OF FIRE SAFETY IN ULTRA HIGHRISE BUILDINGS

Comment on Hawker Stall Fires

Fire Safety Management System in Modern High-rise Buildings - Hong Kong Perspective

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Evacuation Hazards in Crowded Subway Stations

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

Fire Safety in Tall Building: Performance-Based Solutions. Chris Jelenewicz, P.E., FSFPE

SURVEY ON FIRE SERVICE INSTALLATIONS FOR OFFICE BUILDINGS IN HONG KONG

NECESSITY OF CARRYING OUT FULL-SCALE BURNING TESTS FOR POST-FLASHOVER RETAIL SHOP FIRES

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

Underground fires in metro systems failures, accidents and terrorism

A Fire Safety Ranking System for Karaoke Establishments in Hong Kong

DEF Fire Evacuation and Emergency Planning Criteria

Hot Issues in Fire Engineering 12 March 2013

SHOULD SMOKE MANAGEMENT SYSTEM BE PROVIDED IN KARAOKE ESTABLISHMENTS?

Engineering Systems an Incremental Response to Terrorist Threat

OVERVIEW. Increasing Awareness of Occupant Evacuation in Tall Buildings. Traditional Focus has been on Evacuation From Fire

Learning From 50 Years of Hong Kong Skybridges

22 BISHOPSGATE Lift Evacuation Strategy

Hot Issues in Fire Engineering July 2014

NECESSITY OF IN-DEPTH EVALUATION OF LONG-THROW SPRINKLER INSTALLATION AT TALL ATRIA STORING HIGH AMOUNTS OF COMBUSTIBLES

MOIEZ AHMED Chief Fire Warden Director Training - Usha Armour Pvt. Ltd., Bangalore. Fire Drill (Fire Evacuation Drill Procedure)

Evacuation Mode for Total Building Evacuation

Fire safety challenges and performance based fire engineering design of high-rise buildings

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

SURVEY ON THE FIRE SAFETY REQUIREMENTS IN KARAOKE ESTABLISHMENTS

Yunyong P. Utiskul, Ph.D., P.E., CFEI

Fire evacuation drill

Safety Manual: Emergency Response

Passive Fire Protection DuraSystems Barriers Inc.

Simulation of Full-scale Smoke Control in Atrium

technical specification smoke venting systems

Sprinklers Modeling for Tunnel Road Fire Fighting

The Development of Fire Risk Assessment Method for Heritage Building

FULL-SCALE BURNING TESTS FOR RETAIL SHOP FIRES: PRELIMINARY STUDIES

4.13 Security and System Safety

Simulation study of evacuation in high-rise buildings

Legislation Committee No.1

Design of Fire safety in Multi Occupancy Residential Accommodation

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

Emergency Action Plan Leading the Fight

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Fire Safety Strategy

Passive Fire Protection DuraSystems Barriers Inc.

Firefighting operations on fire control centres F5-09 GD

A Brief on Performance- Based Design for Building Fire Safety

SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

SELF PRESERVATION SOCIETY By Jim Creak

Hot Issues in Fire Engineering 28 February 2012

FIRE RISK ASSESSMENT

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

New Auburn Village Center Study Auburn, Maine

Fire Risk Management Policy. UK September 2017

The Macro Quallty Assurance System for Fire Safety Engineering

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

University of Maryland FIRE EVACUATION PLAN

Simulation of Emergency Evacuation in the Arrival Hall of a Crowded Airport

Technical reference Reference & design

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Tall Buildings in Melbourne: Challenging Policy Frameworks

Case Study of Underground Car Park. Team Japan

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Feasibility Study of Use of Elevators in Fire Evacuation in a High-rise Building

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Panic and Emergency Exit Devices

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

NHSScotland Firecode Scottish Fire Practice Note 3 Version 3

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Fire Engineering in High Rise 15 November 2013

- CONSTRUCTION FIRE SAFETY STANDARDS

Design Guidance. Introduction, Approach and Design Principles. Mauritius. November Ministry of Housing and Lands. .. a

Experimental Room Fire Studies with Perforated Suspended Ceiling

Official Plan Review: Draft Built Form Policies

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

University of London

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

A Study on the People Evacuation Safety for the. Underground MRT Station

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

The Development of Automatic Fire Alarm Standards and Related Products in China

General Principles of Smoke Control

URBAN DESIGN BRIEF URBAN DESIGN BRIEF 721 FRANKLIN BLVD, CAMBRIDGE August 2018

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Uniclass L7535 EPIC L13. CI/SfB (57) X. secontrols.com. Smoke Ventilation, Natural Ventilation and Window Automation

DRAFT Northeast Quadrant of Kipling Avenue and Highway 7 DRAFT AUGUST 29, Goals Land Use. The goals of this Plan are to:

Occupational Health & Safety Practitioner. Reading BUILDING FIRE SAFETY

- CONSTRUCTION FIRE SAFETY STANDARDS

Element C3.5 Means of Escape

Financing Transportation Successes from other Jurisdictions

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Transcription:

CTBUH Technical Paper http://technicalpapers.ctbuh.org Subject: Paper Title: Fire and Safety Immediate Action in Providing Fire Safety in Cities with Dense Highrise Buildings; The Possibility of Incorporating Skybridges Author(s): Wood, A. 1 Chow, B.K. 2 McGrail, D. 3 Affiliation(s): 1 University of Nottingham 2 The Hong Kong Polytechnic Unviersity 3 WSP Fire Engineering Publication Date: 2004 Original Publication: Paper Type: CIBSE-HKB/ASHRAE-HKIE Shenyang-Hong Kong Joint Symposium on Healthy Building in Urban Environments, Shenyang, China, 29 30 July 2004 1. Book chapter/part chapter 2. Journal paper 3. Conference proceeding 4. Unpublished conference paper 5. Magazine article 6. Unpublished Council on Tall Buildings and Urban Habitat/Author(s)

Immediate action in providing fire safety in cities with dense highrise buildings: The possibility of incorporating skybridges A. Wood School of the Built Environment, University of Nottingham, University Park, Nottingham, UK D. McGrail WSP Fire Engineering, WSP Hong Kong Ltd, 1/F K.Wah Centre, 191 Java Road, North Point, Hong Kong, China W.K. Chow Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China Abstract As the number of major building fires around the world appears to be increasing, the general public is worrying whether they are safe in the event a building fire. Evacuation is a key issue, especially for cities with dense urban areas as in the Far East. This paper, in reviewing fire safety provisions and fire safety engineering approaches in the context of Hong Kong, proposes the 'skybridge' concept as a way of providing immediate action in the consideration of adequate egress paths. 1

1.0 Introduction The number of major building fires in recent times around the world appears to have increased. In Hong Kong alone in the past few years, there has been the 1996 Garley Building fire [1], caused whilst refurbishing lift shafts without temporary fire protection, the 1997 Tsimshatsui Top One Karaoke Bar fire caused by arson [2], and the 2004 MTR fire, also caused by arson [3]. Loss of life in these three fires were 36, 15 and 17 respectively. Around the world, we have seen the 2001 New York World Trade Centre terrorist fire [4], the 2003 Chicago Building fire [5] and the 2003 underground railway arson fire in Korea [6], amongst many others. It is obvious that the fire safety of our buildings and infrastructure is becoming increasingly paramount. In parallel, public perception of the fire safety of buildings is coming under increasing scrutiny. This is especially true of tall buildings, where building populations - and thus risks of loss of life - are more concentrated. Most high rise buildings around the world have been designed with a phased evacuation strategy in mind, i.e. evacuating a number of floors at a time, and leaving the majority of the building occupants in place. Given the high public profile of the events of the World Trade Centre Towers collapse, it is now doubtful that tall building occupants will feel comfortable to remain in a tall building in an emergency situation, as is required of this phased evacuation approach [7]. The alternative simultaneous evacuation strategy, where all building occupants are evacuated at once, would have a huge impact on the design of tall buildings an increased number and width of fire stairs, the consequential impact on floor space, retrospective incorporation in existing buildings etc? Since September 11 th and the World Trade Centre Towers collapse [4], International groups considering the implications [8,9,10] have made recommendations in 3 general areas: (i) (ii) (iii) the improvement of structural systems, especially with respect to progressive collapse, the improvement of fire proofing to structure, fabric and evacuation routes, and the improvement of vertical evacuation systems, specifically elevators and stairs. Whilst this work is vital towards making tall buildings safer, it is perhaps not enough. The risk to our cities is increasing through terrorism, war and accident as urban densities increase, and the problem needs to be tackled at a more fundamental design level, not as an alternative but in addition to the 2

improved safety mechanisms suggested above. One possible method of improving the safety of tall buildings is by introducing horizontal evacuation at height through use of a skybridge linking towers. The concept of being able to evacuate occupants at a level other than ground, should the building be at risk, seems sensible, especially if any emergency in a tall building effectively cuts off vertical evacuation routes and thus the connection to the ground plane. The Hong Kong Code of Practice for the Provision of Means of Escape in Case of Fire [11] already requires the incorporation of refuge floors into certain high rise buildings. By making further use of these refuge floors for means of escape and commercial activities via high level linkages skybridges could not only greatly increase the level of life safety for building occupants but also add increased commercial viability to these usually dead spaces. This paper discusses the implications of incorporating skybridges in high rise buildings in Hong Kong a city with a history of physical connections between buildings as a strategy for the improved fire safety of cities with dense high rise buildings. It is first, however, necessary to sketch an audit of current regulations / attitudes to fire safety provision in Hong Kong. 2.0 An Audit of Current Fire Safety Provisions Hong Kong There are basically four types of building fires possible in a dense urban fabric such as Hong Kong [12]: (i) Accidental fires: These are fires due to accidents, such as igniting a polyurethane sofa by an electric fault. Many fires reported in the Far East such as the Garley Building fire [1] fall under this category. The heat release rate is usually developed slowly, e.g. approximately 100 kilowatts for 10 minutes. (ii) Arson fires: These fires are set up purposely by igniting sources such as gasoline, e.g. the Hong Kong Karaoke bar fire [2]. The initial heat release rate might be high or low, dependant on intent of the arsonist, with consequences hard to predict. (iii) Attack fires: These might be due to military action or terrorist attack. The whole building might be destroyed within a short period of time by the explosions or resultant fire, e.g. the World Trade 3

Centre, New York [4]. The heat release rate might reach thousands of Megawatts. (iv) Fires due to natural disaster: These are fires created by natural disasters such as earthquakes, e.g. the fires resulting from the 1995 Kobe-Osaka earthquake in Japan [13]. A mass simultaneouslyignited fire on an urban scale might develop, or fire may spread from building to building, attenuated by strong winds. Hong Kong Codes of Practice Fire safety provision for most Hong Kong buildings, as well as buildings internationally, are set up to deal with accidental fires [14]. Normally, passive building construction is combined with active fire protection systems as hardware installations. Very few fire codes ask for software fire safety management [15], until the recent release of BS 7974 [16]. Dealing with an arson fire or terrorist attack fire has been considered, until recently, as a security problem, which would involve police or military expertise. Once a fire occurs, whether accidental or non-accidental, there should be sufficient time for the occupants to leave the building safely. The Passive fire code on means of escape [11] ensures that travel distances are not too long and the number of exits is sufficient. The Code on Fire Resistance in Construction [17] ensures that the building is able to withstand the fire to give building occupants sufficient time to evacuate. The Code on Means of access for fire fighters [18] ensures that firefighters can enter the building to help evacuate occupants and control the fire. The Code on Fire Service Installation and Equipment [19] ensures that there is sufficient support apparatus for the fire fighters. Refuge Floors The design of commercial high-rise buildings in Hong Kong, unlike commercial high-rise buildings elsewhere in the world, require the use of refuge floors. (Refuge floors are also required in industrial, domestic and composite buildings but for the purpose of this paper we will be concentrating upon commercial buildings). All commercial buildings which exceed 25 storeys in height are required to have a refuge floor located at every 25 th floor throughout the building [11]. The incorporation of a refuge floor into a building obviously has a huge impact upon the design of the building, not only from the additional recommendations that are required by the other Hong Kong Codes of Practice such as 4

ventilation, drencher systems and fire resisting floors but also from the effect that they have upon the lettable area of the building. From the point of view of a developer, to lose two whole floors in a 75 storey building to what is in effect dead space is a massive loss to his / her lettable revenue. Fire Safety Management To ensure that all fire safety provisions (hardware) work and occupants know what to do in a fire, there must be an adequate fire safety management system (software) [13,14]. A fire safety plan must include at least the following: Building maintenance plan Staff training plan Fire prevention plan Fire action plan These schemes should be clearly laid down and include what should be done on the passive building design, active fire protection system and control of fire risk factors. Different buildings have different plan layouts, uses and occupants characteristics, therefore, fire safety management schemes need to be building-specific. 3.0 Fire Safety Engineering The use of Fire Safety Engineering in the design of buildings is becoming increasingly widespread throughout the world. Fire Engineering is a relatively new discipline within the engineering field, however, it is quickly becoming recognized as an indispensable part of any engineering design team, particularly where innovation and cost effectiveness are paramount [20]. Whilst European countries are very familiar with the use of fire engineering in the design of buildings, in Asia and the United States it is still perceived as being required only when a building is very complex in design. There is also a misunderstanding among approval authorities, often due to a lack of understanding, that a fire engineered solution should provide equivalence with the code. If this is the case then the code solution is always deemed to be correct, which is obviously not the case. Instead a fire engineered solution should be used to demonstrate the safety of the building occupants or to demonstrate that the functional objectives of the code are satisfied, as opposed to demonstrating that the code solution is always correct. 5

In order to persuade both clients and approval authorities that the incorporation of skybridges into a buildings design aids real benefit, we need to satisfy two fundamentally different criteria. Whilst a client will always be interested in providing the most cost effective solution for the safety of his building occupants, the approval authorites, on the other hand, are not concerned about cost effectiveness but purely life safety, which can obviously cause interesting problems. If a building design is to incorporate a skybridge then the client will want to see real benefit in terms of cost and the approval authorities will want to see a real benefits in terms of life safety. By using fire safety engineering we can address both these criteria in detail. For example if we look at the incorporation of a refuge floor into a high rise building, what is the functional objective of a refuge floor? The objective of a refuge floor can be broken up into a number of different aspects, summarised as follows [21]: - 1. Serve as a place of rest for evacuating occupants 2. Break up evacuation stairs on the refuge floor this reduces the possibility of smoke logged stairs and also reduces the possible stack effect created. 3. Serve to protect disabled/ injured people for a long period of time until fire fighters can rescue them. 4. Act as a command point of the rescue teams to assist evacuation and achieve orderly evacuation of the building. 5. Serving as a fire-fighting base for fire fighters to attack the fire. 6. Serve as a starting point for using lifts for evacuation if this is possible depending on severity and location of the fire, lift design, and number of occupants required to be evacuated. Therefore in order to allow the removal of the refuge floor, all of the above functional objectives should be satisfied. By incorporating a skybridge between two or more buildings all of these objectives can be satisfied whilst increasing the let table area available for the client use. For example as opposed to having a dead space at the 25 th floor of every high rise building you could have interconnected retail areas or restaurants, and only in the case of a fire is the skybridge 6

required to fulfil its secondary function as a means of escape to an adjacent place of safety. The skybridge also provides an increased level of life safety when compared to a refuge floor. With a refuge floor people always remain in the same building in which the fire incident has occurred, with a skybridge you are moving people away from the initial fire incident into another building unaffected by fire. 4.0 An existing network of building linkage in Hong Kong It is currently possible to walk for a square kilometre or more in the Central District of Hong Kong without touching the ground, on a network of skybridges at first floor level. This completely public, pedestrian network runs through buildings instead of around them and is made up of a series of elevated covered walkways that link up the internal circulation systems of a group of buildings. The network began in the 1970 s, in the area to the west of Statue Square, where one land owner Hong Kong Land desired to connect all his adjacent buildings so as to maximise the Fig. 1: The Start of the Skybridge network HongKong Land s linking up of its buildings in the Central District of Hong Kong in the 1970 s access to the commercial activities contained at first floor. This internal, airconditioned link between The Landmark, Alexandra House, Prince s Building, The Mandarin Hotel, Swire House and the Connaught Centre [see Figure 1] became the start of the skybridge network. 7

Today, the network is much extended [see Figure 2]. With the exception of the short area between Chater Gardens and the Hong Kong and Shanghai Bank Headquarters, it is possible to alight on this network at Pacific Place in Admiralty, and not leave it until the Macau Ferry Terminal in Sheung Wan, almost two kilometres away. There is a great variation in the physical make-up of the skybridges. Some are open pedestrian bridges over roads, others are covered walkways between buildings. Much of it is still an internal, air-conditioned link. Fig. 2: Plan of the Central District of Hong Kong, showing current first floor Skybridge linkage / pedestrian network The route is interesting since not only does it create a comfortable pedestrian environment, away from vehicular traffic and a hot, humid climate, it has diverted public routes through traditionally non-public buildings offices, hotels, banks etc. In doing this, it has essentially elevated and extended the public domain upwards, to include both the ground and first floors. And, along this vibrant route in the air, public facilities have flourished: shops, restaurants, galleries etc. 8

5.0 Incorporating skybridges at height The idea of the skybridge is not new. From the 16 th Century when Antonio Contino s Bridge of Sighs joined Venice s Pallazo Ducale to the adjacent prison, connections between buildings above the ground plane have been an instrumental element of both fictional and realized visions. There are currently more than a dozen tower and skybridge arrangements in existence across the world (for more on the historical background of the Skybridge, see Wood [22]). The use of the Skybridge to date though has been restricted to these isolated, one-off examples. Incorporation of physical connections at height throws up considerable challenges; structurally, operationally and psychologically, as well as in design and occupant terms. If skybridges are to become a realistic proposition for the improved safety of tall buildings in dense cities such as Hong Kong, we need to look at these implications in turn: Impact on Client Brief Impact on Internal Planning; the Skylobby Optimum Vertical Placing of the Skybridge Strategic Planning for Incorporation Impact on Structure and Fabric; the Skyportal 6.0 Conclusions It is obvious that, potentially, skybridges could be a significant element in the quest to make our tall buildings safer. In addition, the use of Skybridges gives an opportunity for the maximizing of commercial floor space through increased evacuation efficiency. In Petronas Towers, for example, by fire-rating the skybridge and providing an alternative escape route, not only were evacuation times for a single tower significantly reduced, it was also possible to omit two fire escape stairs form the design which would otherwise have been needed [23]. 9

6.0 References 1. W.K. Chow Numerical studies on recent large high-rise building fire. ASCE Journal of Architectural Engineering, Vol. 4, No. 2, p. 65-74 (1998). 2. SCMP 15 die as fire rips through karaoke bar, South China Morning Post, Hong Kong, 26 January 1997. 3. SCMP 14 injured in peak-hour MTR arson attack Editorial, pp. A1, South China Morning Post, Hong Kong, 6 January, 2004. 4. Federal Emergency Management Agency. World Trade Centre building performance study: Data collection, preliminary observations and Recommendations. FEMA 403. USA. May 2002. 5. SCMP Chicago nightclub fire, South China Morning Post, Hong Kong, 18-19 February 2003. 6. SCMP Taegu's subway line has been beset by disaster Main Section, p.10, South China Morning Post, Hong Kong, 19 February, 2003. 7. Barber, D (2003), Will Occupants of Tall Buildings Obey Instructions from Wardens in Staged Evacuations? CIB-CTBUH International Conference on Tall Buildings, Kuala Lumpur, October 2003. CIB Publication No: 290. 8. Roberts, J. Safety in tall buildings, and other buildings with large occupancy. ISTRUCTE London, July 2002. 9. Wainwright, F. and Bressington, P. Extreme events: The Arup view. Arup UK. May 2002. 10. Foster & Partners. Tall bldgs study: Safety considerations after 11 September. London. 2002. 11. Code of Practice for Provisions of Means of Escape in case of Fire and Allied Requirements, Buildings Department, Hong Kong (1996). 12. W.K. Chow Instant responses On the attack fire at World Trade Centre International Journal on Engineering Performance-Based Fire Codes, Vol. 3, No. 3, p. 128-129 (2001). 13. Japan s worst nightmare, Hong Kong Standard, 18 January (1995). 14. W.K. Chow Proposed fire safety ranking system EB-FSRS for existing high-rise nonresidential buildings in Hong Kong ASCE Journal of Architectural Engineering, Vol. 8, No. 4, p. 116-124 (2002). 15. H.L. Malhotra, Fire safety in buildings, Building Research Establishment report, Department of the Environment, Building Research Establishment, Fire Research Station, Borehamwood, Herts, WD6 2BL, UK (1987). 16. BS 7974 Application of Fire Safety Engineering Principles to the Design of Buildings - Code of Practice, British Standards Institution, UK (2001). 17. Code of Practice for Fire Resisting Construction, Buildings Department, Hong Kong (1996). 18. Code of Practice for Provisions of Means of Access for Firefighting and Rescue Purposes, Buildings Department, Hong Kong (1995). 19. Code of Practice for Minimum Fire Service Installation and Equipment, Fire Services Department, Hong Kong (1998). 20. McGrail D. K., Lay S. F., State of the art building design using fire safety engineering, 2003 Mainland Hong Kong Joint Symposium HKIE-BSD, ASHRAE, CIBSE 21. Olsson P. (2001) Performance-Based Fire Safety Design of Super High-rise Structures, Proceedings from the Building for the 21st Century Conference, The Council on Tall Buildings and Urban Habitat, London. 22. Wood, A. Pavements in the Sky: The use of the skybridge in tall buildings. Architectural Research Quarterly. Volume?. No.? 2004. Cambridge University Press. UK. 23. Pelli, C. and Crosbie, M. Petronas Towers: The architecture of high construction. Wiley- Academy. 2001. Confp1 10