AmpLight group management

Similar documents
AmpLight Lighting Management System

Monitoring Solutions

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

LED Drivers Designed For Control. Anand Upadhyay LED Systems Rosemont IL

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Product Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution


PRESENTS AQUADUCT AUTOMATED WATER-LEAK MONITORING SYSTEM A KINGPIN TECHNOLOGY

The WAVE Plus Instant Notification System for Schools and Colleges

SMS GSM Alarm Messenger

XYZ XYZ XYZ XYZ XYZ XYZ. Energy Utility Based billing for Individual Tenants. Comprehensive Base Station Monitoring. Diesel Generator Monitoring

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

Building Automation solutions

EcoView Energy Management System

wireless. web-based. worthy of the name RACO.

D3 Wireless temperature alarm & monitoring system family. tek-troniks


Continuous, real-time detection, alarming and analysis of partial discharge events

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

IRIS Touch Firmware Enhancements and Additions from Version to Version

DATAssure. Laboratory wireless alarm & monitoring system

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Product Comparison Guide

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

application guide aged care

PROGRAMMABLE 7-DAY RF THERMOSTAT

APPLICATION DATA SHEET

Boztek Solutions` PLAYSTATE

Ion Gateway Cellular Gateway and Wireless Sensors

SC-F3G User Manual 1.0

REA 105 Arc Protection Module. Operator s Manual

Panel Mounted Fault Annunciator Series

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Flow LED robust and streamlined

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Flow LED robust and streamlined

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

Use of the application program

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

HOST SERVER CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM DATA CENTER PLANT BASE STATION. Generator Fuel Level. Battery Monitoring

A secure and smart firm. The JABLOTRON 100 security system with its unique MyJABLOTRON application

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Local Control Network - building controls in perfection

YOUR SCHOOL STAFF NEEDS PROTECTION

Healthy. Atmosphere. for Pigs and Poultry. for a

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Integrated Security Solutions

WAVE SEQUENCER DELIVERS:

Making the Most of Alarms

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Manual GPRS Data Logger PCE-GPRS 2

Connectivity Control Confidence

Products and systems

Security designed for your lifestyle

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Welcome, and thank you for joining us today!

Your partner for intelligent street light systems

Typical applications include the vibration detector. Detection of vibrations and shocks

Outdoor Temperature Sensor

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

Data sheet. Function description. Benefits

Detecting Leaks and Reverse Flow with 60 Series Endpoints

LCF Touch Modbus Datasheet Application Security Advice Caution

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

REMOTE MONITORING AND ALARM SYSTEM

CAN unit for Analog Sensors

C-Bus Four Channel General Input Unit Installation Instructions

Fire Control Panel FS5100

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Arc Fault Protection System D1000

UniStreet simple, costeffective. range. UniStreet. Benefits. Features. Application. Specifications

DYGIZONE GJD910 Lighting Controller & Enunciator

The easiest switch to comfortable white light

Smart Wireless Sensor

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Intelligent addressable fire alarm control panel

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

HF Motion Sensor Introduction

D1000 Arc-fault Protection System

AirFlow Sensor for Dry Contact connection

SECTION LIGHTING CONTROLS

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Wireless M2M Solutions

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Bionics Instrument. Alarm Handling. Gas Alarm Systems

APPLICATION DATA SHEET

Universal fault annunciator for panel mounting

Photoelectric Beam Detector

Parameterisable compact fault annunciator with permanent display

Integrated Security Solutions

Transcription:

AmpLight System Guide AmpLight group management

Table of Contents System description.... 3 Benefits...4 Features....4 Central dimming....5 Benefits....5 Features....5 AmpLight Modules...6 Coded mains...8 Alarms... 10 Reports... 10 2 System Guide - AmpLight group lighting management

System description AmpLight group management is a cabinet-based solution for monitoring and control of road and street lights. It is designed for road authorities such as medium to large municipalities and highway authorities in need for a reliable street lighting control system that can be hosted on-premise. The cabinet controller connects to a group of LED or conventional street lights and can be deployed in both retrofit and new-build scenarios. The cabinets are connected to the light management system through a cellular data connection or wired Ethernet. The light management software is enterprisehosted, by the customer, leveraging the IT infrastructure and capabilities of the customer. A group of luminaires can be controlled by installing an SCU (segment control unit), a surge guard and a battery module in a cabinet. Outdoor luminaires are connected by the electrical infrastructure to the cabinet. The user can then control on/off times based on Astroclock (including trimming), photocell (when installed), or user specified times, remotely with a web application. In an emergency, the user can control the lights manually using the web application or SMS commands from a pre-configured mobile device. Communication between the SCU and a server hosting the application software is enabled via cellular network with SIM card installed in the SCU. Alternatively, the SCU can communicate with the server over wired LAN. When an energy meter is installed, energy consumption is transferred to the AmpWeb server and is visible in the dashboard. Consumption reports are available on a daily, monthly, quarterly, annual or a 3-year basis on overall project or cabinet level. Different switch and dimming schedules can be programmed and assigned to specific dates in advance to save energy. Critical alarms can be configured for notification via SMS text messages on a user s mobile device: a list of alarms is included in this document. The switching operations of cabinet remains functional, even if the connectivity with the server is lost temporarily (about one to 2 days: after that there will be small drifts). In such cases, data is stored in the SCU up to 30 days and will transfer the data to server when connectivity is restored. System Guide - AmpLight group lighting management 3

Benefits Manage your KPIs whilst optimizing your total cost of ownership with automated failure reporting Real-time status feedback increasing maintenance efficiency Maximize your energy savings without compromising safety at night Retrofit - enable benefits of remote light management on existing infrastructure Central dimming - further optimize energy savings; reduced CO 2 footprint and light pollution. Features Map-based GUI with visual indication on status for day-to-day operations Asset information for cabinets and connected luminaires. Scheduled, Astronomical and photocell-based ON/ OFF functionality. Critical alarms over SMS on user mobile device. Programming of schedules remotely and local; manual override operation. Hourly, daily and monthly energy graphs. Scheduled, central dimming with 12 levels. Detailed alarms for maintenance and troubleshooting. Remote cabinet monitoring and control via standard mobile SMS text service. Alarms in server dashboard, per email and per SMS in case of failures Detailed reports for alarms, meter readings, burn time, actions and lights in HTML or Excel formats delivered by email. Designed for and tested under harsh grid conditions. Supports multiple circuits from a cabinet. 4 System Guide - AmpLight group lighting management

Central dimming Central dimming uses coded mains to centrally broadcast dimming signals over mains wiring connected to a large set of luminaires. It overcomes limitations of voltage dimming (such as and conventional power line technology). Central dimming uses your existing infrastructure and leverages LED technology for lower light levels and faster dimming. Benefits Additional energy savings - up to 40% Better ROI - uses existing infrastructure Lower carbon footprint Secure and reliable No impact on the operating lifetime of the luminaires Broad luminaire support: 1 10 V or DALI Safety full light whenever required Features Trouble-free central dimming (up to 40% energy savings, depending on dimming profile) Communicate dimming information from cabinet to luminaires Constant light output (irrespective of voltage fluctuation or line voltage drop) Supports both 1 10 V and DALI dimmable driverbased luminaires Transmits dimming information over long distances No bulky voltage step down transformers for dimming No signal interference from external sources, such as RF No disturbances to other devices in the grid, unlike Powerline Central or local (each luminaire) dimming override possible using an external trigger Flexible dimming level scheduling; 12 levels to choose (including 100% and OFF) 6 kv surge protection Continuous streaming of dimming information over mains Communication does not depend on luminaires (like in RF mesh and Powerline communication) Light management Cabinet/SCU Street lights Connectivity to backend Connectivity through the power grid System Guide - AmpLight group lighting management 5

AmpLight Modules SCU (Segment Control Unit) Main AmpLight cabinet controller Interfaces like the switch, the RS485 and the current are built in the SCU. External modules may be required based on a case-to-case basis 1 to 3-phase mains input Cabinet door monitoring Mains voltage monitoring Photocell input Integrated GPRS USB for software flashing A-bus for power and communications with the other AmpLight modules RS 485 (optional) Contact rating: 5 A (NO) /3 A (NC) @ 277 Vac resistive. 10 A (NO) @ 125 Vac resistive Communication modules for external power metering units Required for meters with RS485 connection 30456789 kwh 2134 kw 4057 2 1 LM24-DIN Switch (optional) Consists of two individually controllable relays. These relays are galvanically isolated and are used for switching minor loads on and off directly and threephase or larger loads via an intermediate breaker. Battery If the main power fails, the Battery will instantaneously take over the power supply of the A Bus. This enables the CPU to store data and send a main power failure alarm to the central server via GPRS/ SMS before it shuts down safely. Initial capacity of 950 mah (7.4 V). Li-Polymer rechargeable, includes safety circuit 1 2 3 4 5 Normally open Common Normally closed Common Normally open 6 System Guide - AmpLight group lighting management

Surge Guard The Surge Guard is designed specifically for the LCN7700 Segment Control Unit, making this module able to withstand surge pulses up to ± 6 kv and burst pulses up to ± 4 kv. Four rated channels, each of which has a built-in thermal protection Withstands surge pulses up to ± 6 kv and burst pulses up to ± 4 kv 3-Phase Coil The AmpLight 3-Phase Coil / current-sensor can be used in combination with the AmpLight Current to measure the supplied mains currents, in order to monitor possible failures and unsafe situations. Power failures, cable breakages, street lamp failures are immediately reported to the central server. Transformer ratio 1000:1 (primary:secondary) Accuracy: 1.5% Current (optional) The Current a highly reliable monitoring device designed for detecting asymmetrical earth leakage in electrical systems and for monitoring current changes in each phase of up to two three-phase circuits. It is used to detect and report under-current, overcurrent, lamp failures, and earth leakage alarms. Leakage current: Input range: 1 to 15 ma, rel. accuracy: ± 0.3% FSD, abs. accuracy ± 5% FSD Current sensor detection range: 5 to 65 A Leakage Coil The AmpLight Leak Coil / current-sensor can be used in combination with the AmpLight Current to measure the leakage current, in order to monitor possible failures and unsafe situations. Earth leakage are immediately reported to the central server.. System Guide - AmpLight group lighting management 7

Coded mains Coded mains components in the control cabinet The Coded Mains Transmitter and Transformer together send a digitally encoded dimming signal with an amplitude of 2 V or 2.6 V and a frequency of 150 Hz or 180 Hz over the mains wiring. Coded mains transformer (LL or LN) Max load: LL= 22 kva; LN=45 kva Built-in 6 kv surge protection Supports 380 to 480 V LL or 120 to 277 V LN load Coded mains transmitter The transmitter can receive dim signals over DALI interface or via 3 times dry contact interfaces from external controller. A coded mains transmitter sends a 3-phase coded signal (dimming information) over the mains wiring, which is decoded in the luminaires. Input 120 to 277 Vac 6KV surge protection Emergency input Coded mains components in the luminaire Coded mains driver Philips Xitanium Full Programmable LED drivers are specifically designed to deliver the highest performance, protection and configurability. Coded mains receiver function integrated in driver 8 System Guide - AmpLight group lighting management

Coded mains receiver LN (Optional for any 1 10 V/DALI driver) Use the Coded Mains Receiver is available to translate Coded Mains to DALI or 1 10 V for standard luminaires with DALI or 1 10 V drivers. Built-in 6 kv surge protection Automatically detects the type of driver connected (DALI or 1 10V) and configures accordingly Coded mains receiver adaptor (Optional for L-L 380 to 480 V) For luminaires working on 380 to 480 V line-line application, the Coded Mains receiver adaptor is used in conjunction with a Coded Mains receiver LN to step down the voltage from 380 to 480 Vac to 220 to 277 Vac. Designed to work with a coded mains receiver and no other connected devices to ensure performance of coded mains System Guide - AmpLight group lighting management 9

Alarms The following list contains the alarms that are supported by AmpLight. Battery mode Battery not connected Battery shutdown Breaker/contactor error - no current on all circuits Burn time exceeded Cabinet door open Coded mains transformer connection error Coded mains transmitter dry contact activated Coded mains transmitter emergency override Coded mains transmitter HW error Communication is not available - per class Configuration Dispatch Failed Leakage Detected Light on, manually on or contactor hanging Light switching failed Main power failure Missing meter Missing module Module not responding Current error - above threshold - per phase Current error - below threshold - per phase Overvoltage error - per phase Photocell broken Switch module not working Undervoltage/No voltage error - per phase Reports You can generate the following reports as HTML or Excel files: Meter reports Detailed meter Consumption report Energy billing report Burn time report Action report Alarm Modules Light commands Photo cell Light status Reports Other Lamp surveillance Preventive lamp replacement Critical lamp failure 10 System Guide - AmpLight group lighting management

System Guide - AmpLight group lighting management 11

Version 1, 14 February 2018 2018 Philips Lighting Holding B.V., all rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. www.lighting.philips.com