OR N El) THERMOSTATIC MIXING VALVES I\STALATIO\, OPERATING, ADD MAI \TE\A\CE I\STRUCTIO\ S MODEL: H-32 TYPE: H.3201

Similar documents
THERMOSTAT PIPE UNION AND CHECK VALVE (BOTH INLETS) CHECK VALVE \REI URN LIMITER MIXED

Horne Engineering Ltd INSTALLATION, COMMISSIONING, OPERATING AND MAINTENANCE INSTRUCTIONS

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Installation, Operating and Maintenance Guide

Euromixer Thermostatic Mixing Valves

Own. Thermostatic Mixing Valve. Owner s Manual Containing. Installation, Commissioning and Maintenance guides. Lic. WMKA1895 AS SAI-Global.

Installation, Operating and Maintenance Guide

INSTALLATION INSTRUCTIONS

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Thermostatic mixing valves with replaceable cartridge for centralized systems

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Thermostatic mixing valves with interchangeable cartridges

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Mira Reflex Thermostatic Bar Valve

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Thermostatic Bar Valves

Thermomix Underfloor Heating Control Pack

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Self-help Temperature Adjustment

SEALED THERMAL STORE

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

METRO BASIN MONO MIXER CHR

Installation Instructions and User Guide

Plus Bath Shower Mixing Valve CP and PL30020CP

Powerstock Storage Tank

Intatherm Safe Touch Basin Tap IT1008CP

Kiko Bath Shower Mixing Valve KK90015CP

Inta City Shower Mixing Valve CT20010CP

Thermostatic Bar Valve

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Installation Instructions Thermostatic Bar Shower Valve ALTO ECOTHERM

Installation Instructions Flute Tap Range

Telo Shower Mixing Valve TL10016CP

Alpha CombiMax 350 and 600

shower panel specification manual 2008

INSTALLATION INSTRUCTIONS

Uniclass L725111:D4 EPIC H32. CI/SfB 4 (53.9) X. thermostatic tap specification manual OPTITHERM

AQUABLEND 1500 SOLAR THERMOSTATIC MIXING VALVE

Installation Instructions and User Guide

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Sema thermostatic bar mixer Installation and operating instructions

Rada 425R Installation and Maintenance

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

METRO BATH FILLER MOUNTED CHR

Unvented Electric Water Heater 10/15 litre Undersink

Beautifully Traditional

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

TYNE. Installation and Operating Instructions. Thermostatic bath shower mixer. Installers please note these instructions are to be left with the user

Infra Red Thermostatic Wall Mixer

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Varsity Concealed Shower System

Dove Eco thermostatic bar mixer shower

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower. Installers please note these instructions are to be left with the user

THERMOSTATIC SHOWER VALVE

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

X A M G3/4 G3/

Basin Tap. Time delay maximum 2 seconds

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Deluge Shower Mixing Valve 10045CP

Mira Select Flex Thermostatic Mixer

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

THAMES single lever built-in thermostatic mixer valve

THE QUALIFICATIONS INSTALLATION INSTRUCTIONS NEW SQUARE EXPOSED THERMOSTATIC SHOWER VALVE CHR

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Mira Realm Thermostatic Mixer

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Thermostatic Bath Shower Mixer. Without shower kit.

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

Shower Panels with a Thermostatic Sequential Control

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

VERTICAL GLANDLESS PUMP

Mercury Mixing Kit (Code: ME1053)

Artisan Thermostatic Bath Filler

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Inta City Concealed Shower Mixing Valve CT80010CP

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

FOR INSTALLING AND USING

These instructions must be left with the user.

INSTALLATION INSTRUCTIONS

Beautifully Traditional

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

INSTALLATION INSTRUCTIONS

Transcription:

OR N El) THERMOSTATIC MIXING VALVES I\STALATIO\, OPERATING, ADD MAI \TE\A\CE I\STRUCTIO\ S MODEL: H-32 TYPE: H.3201 HOT SUPPLY THERMOSTATIC MIXING VALVE PIPE UNION AND TEMPERATURE ADJUSTMENT TH ERMOM E I ER MIXED FLOW i TEMPERATURE RANGE SHOWN HERE COLD SUPPLY PIPE UNION AND DEAD-LEG VERSION THERMOSTATIC MIXING VALVE HOT SUPPLY PIPE UNION AND TEMPERATURE ADJUSTMENT TH ERMOM E I ER / / - \ MIXED FLOW III ---r r-- - 1 < MIXED RETURN RETURN TO HEATER < PIPE UNION AND COLD SUPPLY SOB _,--11-IERMOSTATIC 1111111111111..."-- RETURN LIMITER RECIRCU_ATIO\ VERSIO \ FLOW INDICATOR /

Page 2 OPERATING CONDITIONS: MAX /M. HOT WATER SUPPLY TEMPERATURE: 85'C MIN I M. HOT WATER SUPPLY TEMPERATURE: MIXED TEMPERATURE + 10 K MAX IM. COLD WATER SUPPLY TEMPERATURE: MIXED TEMPERATURE 10 K MAX /M. STATIC PRESSURE: 10, bar MAX,M. PRESSURE DROP THROUGH VALVE: 2, bar MAX IM. RECOMMENDED FLOW RATE: 2.5 LITRE/sec HOT AND COLD SUPPLY PRESSURES SHOULD BE NOMINALLY EQUAL. (i.e. THE HOT AND COLD STATIC HEAD SHOULD BE EQUAL) RANGES OF TEMPERATURE ADJUSTMENT: (15 to 32 C) (32 to 52*C) (45 to 62 C) (58 to 80 C) INSTALLATION: From the fallowing diagrams, identify the type of system to be installed. The associated pipework on site should be schematically the same as that shown, and the recirc. pump(s) should be located where shown. Ensure that the TEMPERATURE RANGE shown on the ADJUSTMENT LABEL matches the requirement for the job. The MIXING VALVE can be fitted horizontal or vertical, but the FLOW INDICATOR must be in a horizontal pipe with the glass dome uppermost. Before final fitting, ensure that the hot and cold supply pipework is internally clean: if possible, flush throe before final connection to the MIXING VALVE. NEVER apply torque to the MIXING VALVE ASSEMBLY: when making up pipework connections, ALWAYS use two wrenches or spanners. If brazed or soldered pipe fittings are used they should be made up before connecting to the MIXING VALVE. IMPORTANT: Special instructions for fitting the RETURN LIMITER are shown on page 7. HOT SUPPLY HOT RETURN 14 COLD SUPPLY TYPICAL INSTALLATION H-32 THERMOSTATIC MIXING VALVE SUPPLYING PRE MIXED WARM WATER TO SHOWERS OR WASH BASINS. II\

CI-ECK VALVE TEMP./PRESSURE Page 3 RELIEF VALVE COLD SUPPLY 01 MIXED WATER SERVICE (FLOW) -11D-MIXED INKIER SERVICE (RETURN).4 N. VESSEL WATER HEATER TYPICAL INSTALLATION H-32 THERMOSTATIC MIXING VALVE Fl I IE.D TO AN UNVENTED WATER HEATER OR BOILER. vegr COLD WATER STORAGE TPNK HOT WATER SERVICE (FLOW) HOT WATER SERVICE (RETURN).4 01 MIXED WATER SERVICE (FLOW) -13-MIXED WATER SERVICE (RETURN) CALORIFIER OR WATER HEATER COMMISSIONING and TEMPERATURE ADJUSTMENT: To flood the system, open both hot and cold inlet isolating valves. Ensure that the hot and cold supplies are at their designed pressures and temperatures. TYPICAL INSTALLATION Open a few mixed water outlets and wait until the hot and cold inlet temperatures are stable. H-32 THERMOSTATIC MIXING VALVE FITTED TO A CALORIFIER FOR HOT WATER AND MIXED WATER SERVICES. If the mixed water temperature requires adjustment, turn the adjusting key clockwise to reduce the temperature or anti clockwise to increase it. Turn the key only 1/2 TURN at a time and allow the temperature to settle. FOR RECIRCULATION SYSTEMS: When the mixed water temperature has been set, close the taps and start the recirculation pump. Observe the FLOW INDICATOR; while the recirculation pipework is heating up, the ball in the glass dome should be moving actively; (at this stage, the mixed water temperature may show a slight increase). When all the pipework has heated thro e the FLOW INDICATOR will show a reduced flow and any temporary increase in mixed water temperature will return to normal. REMEMBER: When making temperature adjustments, two or three outlets must be running. When checking the recirculation temperature, all outlets must be closed; when outlets are running the FLOW INDICATOR may show no flaw, this is normal. RETURN LIMITER: The RETURN LIMITER is pre set; to alter this setting see instructions on page 7.

Page 4 ROUTINE INSPECTION: The MIXING VALVE should be inspected annually, or more frequently on sites where scaling is prevalent. Stop the recirculation pump and close all the isolating valves. Clean the strainers, (if fitted), at the hot and cold inlets. Remove the VALVE COVER and CARTRIDGE from the THERMOSTATIC MIXING VALVE. (See page 5, SERVICING THE THERMOSTATIC MIXING VALVE). If scaling has occurred on the internal parts, a full service should be carried out. After re assembling the THERMOSTATIC MIXING VALVE, re open all the isolating valves and re start the recirc. pump. Check at the FLOW INDICATOR that recirculation has been established. Open a few taps and check that the mixed water temperature is normal. FAULT FINDING SYMPTOM POSSIBLE CAUSE ACTION Mixed water temperature too high, when mixed water is being used. Temperature setting too high. Temperature has been set when hot supply temperature is too low. Hot water has migrated into cold water supply. Re adjust temperature setting. Re adjust when hot supply is at design temperature. Close all mixed water outlets and check that cold supply pipework remains cold. Mixed water temperature increaces when no mixed water is being used, (Recirculation only). Mixed water temperature too low, when mixed water is being used. Mixed water temperature too low, when no mixed water is being used, (Recirculation only). Mixed water temperature varies, and does not respond to adjustment. Mixed water flow rate is reduced. Mixed water temperature Suddenly runs cold. Thermostat Element has failed. Return Limiter requires adjustment, or servicing. Temperature setting too low. Hot o supply suppy temperature is low. Recirculation has failed due to pump failure or air locking. Return Limiter requires adjustment, or servicing. The "CARTRIDGE" has seized in the THERMOSTATIC MIXING VALVE. The Thermostat Element has failed. Partly blocked Strainers Supply pressure has fallen. Extra demand has been added to the system. Maximum allowable flow rate has been exceeded. (see OPERATING CONDITIONS)) Replace Thermostat Element. See page 6. Follow instructions on page 7. Re adjust temperature setting. See page 3 temperature at hot supply pipework. Check temperature at boiler or water heater. Check "FLOW INDICATOR" as described in Commissioning, page 3. Follow instructions on page 7. Carry out a full service. See pages 5 & 6 Replace Thermostat Element. See page 6 Clean the Strainers at the hot and cold inlets. Check pressurisation unit and boiler pressure. Check all valves are full open. Check maximum flow rate for the "MIXING VALVE" against maximum expected flow rate. (page 2) Fit auxilliary mixing valve in parallel, or, reduce the system demand.

Page 5 THERMOSTATIC MIXING VALVE, SERVICING THE H-32 ADJUSTING SCREW ADJUSTMENT SEALS (3) VALVE COVER COVER SEAL CARTRIDGE PUI I FR (TOOL No. HT-335) Turn the "ADJUSTING SCREW" anti clockwise till it comes to a stop; NOTE THE NUMBER OF TURNS (this helps when resetting the valve). Unscrew and remove the "VALVE COVER". Fit the "CARTRIDGE PUI I FR" to the two tapped holes on the face of the "CARTRIDGE". Withdraw the "CARTRIDGE", "RETURN SPRING", "RETAINING WASHER", and SPRING SUPPORT WASHER". Turn the "ADJUSTING SCREW" fully clockwise and remove it from the "VALVE COVER". Remove the 3 "ADJUSTMENT SEALS", "COVER SEAL", "SPOOL SUPPORT RING", and "SLIDE VALVE SEAL". To remove the "SLIDE VALVE SEAL", pierce it with a sharp pointed probe and ease it from its groove. Clean the internal machined surfaces, in particular the "HOT VALVE FACE" "COLD VALVE FACE" COLD VALVE FACE 0 RING GROOVES THE BORE AT THE "SLIDE VALVE SEAL" THE BORE AT THE "ADJUSTMENT SEALS" THE BORE IMMEDIATELY BELOW THE "SPOOL SUPPORT RING" For cleaning use scouring cloth e.g. "SCOTCHBRITE", or a domestic pot cleaner. CARTRIDGE SEE PAGE 6 HOT INLET SPRING SUPPORT WASHER RETURN SPRING COLD INLET The "CARTRIDGE" servicing instructions are shown on page 6. RE ASSEMBLY: SEALS and 0 RINGS which have been removed should be replaced by new ones and lightly smeared with silicone grease before fitting. The "SLIDE VALVE SEAL" is in two parts, fit the black 0 RING first, then fold the white "TEFLON" ring into a heart shape and enter it into its groove; make sure it is fully entered and flush with the machined bore. SLIDE VALVE SEAL RETAINING WASHER SPOOL SUPPORT RING I HOT VALVE FACE Fit the "RETAINING WASHER" with the side with the chamfered edge facing downwards, i.e. nearest the TEFLON RING. On the "VALVE COVER", lightly smear the bore which carries the "ADJUSTMENT SEALS" with silicone grease and screw in the "ADJUSTING SCREW" all the way to its stop. Slide the "SPRING SUPPORT WASHER" and "RETURN SPRING" on to the CARTRIDGE and insert into the valve body. Screw on the "VALVE COVER", while pushing against the resistance of the "RETURN SPRING". Return the "ADJUSTING SCREW" to its original setting prior to dismantling. PARTS REPLACEMENT SCHEDULE: 0 RING SEALS 3 YEARS All other parts are available but need SLIDE VALVE SEAL 6 YEARS only be replaced if physical damage has occurred. THERMOSTAT ELEMENT 6 YEARS TO ORDER SPARE PARTS: SEE PAGE 8

Page 6 SERVICING THE CARTRIDGE H-32 ELEMENT GUIDE PUSH ROD SEAL '.1.ELEMENT COLLAR ELEMENT SUPPORT SPRING : INDICATES SEALING SURFACES WHICH MUST BE CLEAN, SMOOTH, AND UNDAMAGED. 1) GRIP THE HEXAGON AND 2 RATS WHERE SHOWN ABOVE. 2) UNSCREW AND REMOVE THE ELEMEI1T GUIDE 3) REMOVE THE THERMOSTAT ELEMEI1T. 4) DO NOT ATTEMPT TO REMOVE THE SLIDE VALVE FROM THE SPOOL 5) CLEAN ALL PARTS, EXCEPT THE SPOOL, USING SCOURING CLOTH, e.g. SCOTCHBRITE, OR A DOMESTIC POT CLEANER. NOTE: THE SPOOL HAS AN ANTI FOULING SURFACE TREATMENT WHICH MUST NOT BE SCRATCHED OR ABRADED; IF IT REQUIRES CLEANING, USE A SOFT CLOTH AND WATER. 6) FOR HEAVY SCALE, USE A DESCALING FLUID; DO NOT IMMERSE THE THERMOSTAT ELEMENT IN DESCALING FLUID. 7) ENSURE THE INNER SURFACES OF THE "ELEMENT GUIDE, AND SPODL ARE CLEAN. 8) RENEW THE PUSH ROD SEAL. 9) RENEW THE T1-IERMOSTAT ELEMENFT IF IT IS MORE THAN 6 YEARS OLD. 10) IF RE USING THE 'THERMOSTAT ELEMENTS ; PULL OUT THE PISTON AND ENSURE THAT IT IS CLEAN AND SMOOTH, AND SLIDES FREELY IN IT'S HOUSING. 11) SMEAR THE PISTON WITH SILICONE GREASE BEFORE REPLACING IT. 12) REASSEMBLE THE CARTRIDGE USING TWO SPANNERS AS BEFORE, AND APPLY A LIGHT TORQUE TO SECURE. `4

THE THERMOSTATIC REIURN LIMITER Page 7 PARTS UST REF. DESCRIPTION 1 COUPLING SEAL 2 VALVE SEAT COUPLING NUT 3 VALVE PLUG 4 RETURN SPRING 5 VALVE COVER 6 OAP SEAL 7 ADJUSTING SCREW 8 ADJUSTMENT CAP 9 COVER SEAL 10 GUIDE RING 11 Fl FMENT ASSEMBLY PARTS REPLACEMENT SCHEDULE: 0 RING SEALS ELEMENT ASSEMBLY 3 YEARS 6 YEARS All other parts are available but need only be replaced if physical damage has occurred. TEMPERATURE ADJUSTMENT The RETURN LIMITER is factory pre set according to your order, it controls the temperature of the recirculating mixed water when all the draw off taps are closed. If, during these periods the mixed water temperature is too high or too low, the RETURN LIMITER can be re set as follows. Unscrew the ADJUSTMENT CAP (8), and turn the ADJUSTING SCREW (7) clockwise to reduce the temperature, or anti clockwise to increase it. The calibration is approx. 6*C per 1/2 turn of the adjusting screw. While the ADJUSTMENT CAP is off, there may be a slight leakage of water. SERVICING Unscrew the VALVE COVER (5) and withdraw and clean the internal parts. Check that the VALVE PLUG (3) is free to slide through the VALVE SEAT (2), and that the ELEMENT ASS'Y. (11) is free to slide in the VALVE COVER (5). Lubricate 0 RINGS with silicone oil or grease. When a new ELEMENT ASST. is required, a slight re adjustment may be necessary. { MIXED RETURN RETURN LIMIER RETURN TO HEATER < FLOW INDICATOR ENSURE THAT THE GLASS DOME ON THE FLOW INDICATOR IS POSMONED VERTICALLY UPWARDS. NOTE DIRECTION OF FLOW.

Page 8 THERMOSTATIC MIXING VALVE H-32 TYPE: H.3201 PARTS LIST SERIAL No. REF. DESCRIPTION 1 ADJUSTING SCREW 2 LCCKSHIELD NUT 3 ADJUSTMENT SEAL (3) 4 VALVE COVER 5 COVER SEAL 6 RETURN SPRING 7 COUPLING SEAL (2) 8 SLIDE VALVE SEAL 9 VALVE BODY 10 RETAINING WASHER 11 SPOOL SUPPORT RING 12 OUTLET BODY TO ORDER SPARE PARIS QUOTE: VALVE TYPE & SERIAL No. PART REF. No. PART NAME THIS DRAWING No. SPARES FOR HORNE-32 T.M.V. TYPE: H.3201 SERIAL No. HH-2345 13 PUSH ROD 14 ELEMENT GUIDE 15 PUSH ROD SEAL 16 OVER HEAT SPRING 17 SLIDE VALVE 18 SLIDE VALVE RETAINER 19 SPRING SUPPORT WASHER 20 ELEMENT COLLAR 21 ELEMENT SUPPORT SPRING 22 THERMOSTAT ELEMENT 23 SPOOL SUDS VALVE SEAL REF. 8, DR'O. No. 7308 STANDARD SPARES KIT COMPRISES ITEMS MARKED: * DWG. No. 7308 THE HORNE ENGINEERING CO. LTD. Tel. 01505 321455 Fax. 01505 336287 PO BOX 7, RANKINE STRELI, WEB SITE: www.horne.co.uk JOHNSTONE, RENFREWSHIRE, PA5 8BD E mail: sales horne.co.uk