T S A 048 S 4 N 4 1 T

Similar documents
DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

T P A 048 S 4 N 4 1 T

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

2 shp 13 lc 1 36 t - 1 a

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

14 AC x

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

T P A 120 S 4 S N 1 Y

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

Visit us at For the latest technical information,

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

ELITE Series R-410A - Two-Stage Compressor

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

ELITE Series Variable Capacity

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

13 GEP A L P - 1 A

ELITE Series Variable Capacity

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Commercial High-Efficiency Condensing Units

RGE 13 A T - 1 A

Commercial High-Efficiency Condensing Units

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

PACKAGE AIR CONDITIONER

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

C22FC Bulletin # October 1993 Supersedes May 1993

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

C22 Bulletin # October 1993 Supersedes May 1993

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Ruud Achiever Series Air Conditioners

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

R4H4. Product Specifications

Lennox 8 Series Single Zone - R-410A

16 SEER TWO-STAGE AIR CONDITIONERS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

TECHNICAL SPECIFICATIONS

WCH5**4. Product Specifications

Corp L2 Revised

N4A6. Product Specifications

TECHNICAL SPECIFICATIONS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

R4H4. Product Specifications

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

PAJ3. Product Specifications

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

PAR5. Product Specifications

TECHNICAL SPECIFICATIONS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

CB X 32 mv

TECHNICAL SPECIFICATIONS

R 410A Ducted Horizontal Air Conditioner

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Advance Release September 2009

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

N4H4. Product Specifications

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data. Fig. 1 - Unit 50VR -A

Transcription:

E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S TS T-Class Split System Units R-40A - 50 HZ Bulletin No. 49035 September 2009 MODEL NUMBER IDENTIFICATION Nominal Capacity - 7 to 7.6 kw (2 to 5 Ton) Cooling Capacity - 6.4 to 7.6 kw (2 800 to 60 000 Btuh) T S A 048 S 4 N 4 T Family T = Product Line Unit Type S = Split-System Air Conditioner Major Design Sequence A= First Generation B = Second Generation Nominal Cooling Capacity 024 = 7.0 kw (2 tons) 030 = 8.8 kw (2.5 tons) 036 = 0.5 kw (3 tons) 048 = 4. kw(4 tons) 060 = 7.6 kw (5 tons) Refrigerant Type 4 = R-40A Voltage T = 220/240V-phase-50hz M = 380/420-3phase-50hz Minor Design Sequence = First revision 2 = Second Revision 3 = Third Revision Coil Type 4 = Four-sided Part Load Capability N = No part load, single-stage compressor Cooling Efficiency S = Standard Efficiency

FEATURES AND BENEFITS Contents Dimensions...8 Expanded Ratings - Single Phase Models... Expanded Ratings - Three Phase Models...6 Features And Benefits...2 Installation Clearances...9 Model Number Identification... Optional Conventional Control Systems..7 Ratings - Single Phase...0 Ratings - Three Phase...0 Sound Data...9 Specifications - Single Phase...5 Specifications - Three Phase...6 D C B E F TESTING Rated at test conditions included in Air-Conditioning, Heating and Refrigeration Institute (AHRI) Standard 20/240 when operating at rated voltage and air volumes. Units and components within bonded for grounding to meet safety standards for servicing required by Underwriters Laboratories (UL) and the International Electrotechnical Commission (IEC). Units tested by Intertek for conformity assessment on the conditions set out in the New Approach Directives in support of CE marking. The CE (Conformité Européenne) marking certifies that a product has met EU (European Union) consumer safety, health or environmental requirements. International Organization for Standardization (ISO) 900 Registered Manufacturing Quality System APPLICATIONS 7 through 7.6 kw Single or three-phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See Ratings table. See Indoor Coils and Air Handlers sections for data. Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job. B C D G REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A Unit pre-charged with refrigerant. See Specification table. Condenser Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Entire coil is accessible for cleaning. Polyvinyl Chloride (PVC) coated steel wire coil guard furnished. 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 2

AFEATURES AND BENEFITS High Capacity Liquid Line Drier Furnished with unit for field installation. Approved for use with R-40A systems. Traps any moisture or dirt that could contaminate the refrigerant system. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Manual reset. OPTIONS Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See Ratings Table. Chatleff-style fittings. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at -2 C and closes at 4 C Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. Single Pole, Single Throw (SPST), normally-closed switch, automatic reset switch mounted on suction line. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for -060 models. Must be field fabricated. E COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Factory installed crankcase heater protects against refrigerant migration that can occur during low ambient operation. OPTIONS Compressor Sound Cover A reinforced vinyl compressor cover containing a 38 mm thick batt of fiberglass insulation. All open edges are sealed with a 25 mm wide hook and loop fastening tape. 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 3

FEATURES AND BENEFITS CONTROLS OPTIONS Compressor Hard Start Kit Single-phase units are equipped with a permanent split capacitor (PSC) compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 2 C. Compressor Time-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See Ratings Tables for usage. Low Ambient Kit Air conditioners operate satisfactorily down to 7 C outdoor air temperature without any additional controls. Low Ambient Control Kit can be field installed, allowing unit operation down to - C. Thermostat Thermostat not furnished with unit and must be ordered extra. See Page 7. Timed-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. F G CABINET Heavy gauge steel cabinet with five station metal wash process. Powder paint finish provides superior rust and corrosion protection. Painted base section. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection suction and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. OPTIONS Hail Guards Constructed of louvered, heavy-gauge steel painted to match cabinet. Surrounds unit on all four sides to prevent damage to the coil. Mounting Base Provides permanent foundation for outdoor units. High density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand the rigors of the sun, heat, cold, moisture, oil and refrigerant. Will not mildew or rot. Can be shipped singly or in packages of 6 to a carton. Unit Stand-Off Kit Black, high-density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 4

SPECIFICATIONS - SINGLE PHASE General Model No. TSA024S4 TSA030S4 TSA036S4 TSA048S4 TSA060S4 Data Nominal kw (tonnage) 7.0 (2) 8.8 (2.5) 0.5 (3) 4. (4) 7.6 (5) Connections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d. - in. 3/4 3/4 7/8 7/8 -/8 Refrigerant (R-40A) furnished.98 kg (4 lbs. 6 oz.).93 kg (4 lbs. 4 oz.) 2.52 kg (5 lbs. 9 oz.) 3.40 kg (7 lbs. 8 oz.) 4.54 kg (0 lbs.) Outdoor Net face area Outer coil.05 (.33).23 (3.22).52 (6.33).95 (2.0).73 (8.67) Coil m 2 (sq. ft.) Inner coil - - - - - - - - - - - -.67 (7.96) Tube diameter - in. 5/6 5/6 5/6 5/6 5/6 Number of rows 2 Fins per meter (per inch) 024 (26) 024 (26) 024 (26) 024 (26) 866 (22) Outdoor Fan Diameter - mm. 457 (8) 457 (8) 559 (24) 559 (24) 559 (24) Number of blades 3 4 4 4 4 Motor W (hp) 75 (/0) 50 (/5) 85 (/4) 85 (/4) 85 (/4) L/s (cfm) 924 (958) 944 (2000) 377 (297) 443 (3058) 46 (3000) Rev/min 842 908 688 696 692 Watts 38 54 250 246 238 Shipping Data - kg (lb.) package 56 (23) 60 (33) 8 (78) 88 (94) 99 (28) Electrical Data Line voltage data - 50 hz - phase 220 / 240V 220 / 240V 220 / 240V 220 / 240V 220 / 240V 2 Maximum overcurrent protection (amps) 25 25 40 35 45 3 Minimum circuit ampacity 4.3 6.4 24. 22. 26.6 Compressor Rated load amps 0.9 2.2 7.9 6.3 9.9 Locked rotor amps 60.0 72.0 98.0 98.0 28.0 Condenser Full load amps 0.7..7.7.7 Fan Motor Locked rotor amps.4 2.0 3. 3. 3. OPTIONAL ACCESSORIES - must be ordered extra Compressor Hard Start Kit 0J42 88M9 Compressor Low Ambient 45F08 Cut-Off Compressor Sound Cover 69J03 Compressor Time-Off 47J27 Control Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Hail Guards 92M87 92M88 92M93 Indoor Blower Off Delay 58M8 Relay Loss of Charge Switch Kit 84M23 Low Ambient Kit 34M72 Mounting Base 69J06 69J07 Refrigerant L5-4-20, L5-4-30, Line Sets L5-4-40, L5-4-50 L5-65-30, L5-65-40, L5-65-50 Field Fabricate Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 4.6 m (5 ft.) length of refrigerant lines. 2 Heating Air Conditioning and Refrigeration type circuit breaker or fuse. 3 Refer to local codes to determine wire, fuse and disconnect size requirements 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 5

SPECIFICATIONS - THREE PHASE General Model No. TSA036S4 TSA048S4 TSA060S4 Data Nominal kw (tonnage) 0.6 (3) 4.0 (4) 7.6 (5) Connections Liquid line o.d. - in. 3/8 3/8 3/8 (sweat) Suction line o.d. - in. 7/8 7/8 -/8 Refrigerant (R-40A) furnished 2.52 kg (5 lbs. 9 oz.) 3.40 kg (7 lbs. 8 oz.) 4.54 kg (0 lbs.) Outdoor Coil Outdoor Fan Net face area Outer coil.23 (3.22).95 (2.00).73 (8.67) m 2 (sq. ft.) Inner coil - - - - - -.67 (7.96) Tube diameter - in. 5/6 5/6 5/6 Number of rows 2 Fins per meter (per inch) 024 (26) 024 (26) 866 (22) Diameter - mm (in.). 457 (8) 559 (22) 559 (22) Number of blades 4 4 4 Motor W (hp) 25 (/6) 85 (/4) 85 (/4) L/s (cfm) 944 (2000) 443 (3058) 46 (3000) Rev/min 908 688 692 Watts 54 246 238 Shipping Data - kg (lb) package 6 (35) 88 (94) 99 (28) Electrical Data Line voltage data - 50 hz - 3 phase 380 / 420V 380 / 420V 380 / 420V 2 Maximum overcurrent protection (amps) 5 5 20 3 Minimum circuit ampacity 8.6 0.8 4.3 Compressor Rated load amps 6.4 7.8 0.6 Locked rotor amps 46.0 5.5 74.0 Condenser Full load amps 0.55.0.0 Fan Motor Locked rotor amps. 2.3 2.3 OPTIONAL ACCESSORIES - must be ordered extra Compressor Crankcase Heater 93M04 93M05 Compressor Low Ambient Cut-Off 45F08 Compressor Sound Cover 69J03 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Hail Guards 92M87 92M88 92M93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Switch Kit 84M23 Low Ambient Kit 34M72 Mounting Base 69J06 69J07 Refrigerant Line Sets L5-65-30, L5-65-40, L5-65-50 Field Fabricate Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 4.6 m (5 ft.) length of refrigerant lines. 2 Heating Air Conditioning and Refrigeration type circuit breaker or fuse. 3 Refer to local codes to determine wire, fuse and disconnect size requirements. 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 6

OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS - FIELD INSTALLED COMMERCIAL TOUCHSCREEN THERMOSTAT Intuitive Touchscreen Interface - Two Stage Heating / Two Stage Cooling Conventional or Heat Pump - Seven Day Programmable - Four Time Periods/Day - Economizer Output - Title 24 Compliant - ENERGY STAR Qualified - Backlit Display - Automatic Changeover C0STAT02AEL (4W8) Sensors For Touchscreen Thermostat Remote non-adjustable wall mount 20k temperature sensor... C0SNZN0AE2- (47W36) Remote non-adjustable wall mount 0k averaging temperature sensor... C0SNZN73AE- (47W37) Remote non-adjustable duct mount temperature sensor... C0SNDC00AE- (9L22) Outdoor temperature sensor... C0SNSR03AE- (X448) Accessories For Touchscreen Thermostat Locking cover (clear)... C0MISC5AE- (39P2) Remote sensors for C0STAT02AEL can be applied in the following combinations: () C0SNZN0AE-, (2) C0SNZN73AE-, (2) C0SNZN0AE- and () C0SNZN73AE-, (4) C0SNZN0AE-, (3) C0SNZN0AE- and (2) C0SNZN73AE. DIGITAL NON-PROGRAMMABLE THERMOSTATS Intuitive Interface - Automatic Changeover - Simple Up and Down Control Two-stage heating / cooling conventional systems... C0STAT0AEL (3K98) Sensor For Digital Non-Programmable Thermostats Above Remote wall mounted temperature sensor... C0SNZN00AE- (26K57) Intuitive Interface - Automatic Changeover - Backlit Display - Simple Up and Down Control One-stage heating / cooling conventional systems... C0STAT2AEL (5M32) Sensor For Digital Non-Programmable Thermostats Above Outdoor temperature sensor... C0SNSR04AE- (X2658) Accessories For Digital Non-Programmable Thermostats Above Optional wall mounting plate... C0MISC7AE- (X2659) 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 7

DIMENSIONS - MM (INCHES) (4-3/8) (4-3/8) INLET AIR (4-3/8) (4-3/8) INLET INLET OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COMPRESSOR AIR AIR COIL DRAIN OUTLETS (Around perimeter of base) SUCTION LINE CONNECTION 62 (6-3/8) (4-3/8) INLET AIR TOP VIEW LIQUID LINE CONNECTION 62 (6-3/8) (4-3/8) TOP VIEW BASE SECTION A CONDENSER COIL FAN DISCHARGE A AIR COMPRESSOR C B ELECTRICAL INLETS SUCTION & LIQUID LINE CONNECTIONS 2 (5) 2-3/4 (70) SIDE VIEW 3/4 (9) OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) SIDE VIEW Model No. A B C mm inches mm inches mm inches TSA024S4 66 24-/4 64 25-/4 66 24-/4 TSA030S4 66 24-/4 743 29-/4 724 28-/2 TSA036S4 - Single Phase 66 24-/4 743 29-/4 724 28-/2 TSA036S4 - Three Phase 78 28-/4 743 29-/4 724 28-/2 TSA048S4 78 28-/4 946 37-/4 92 36-/4 TSA060S4 78 28-/4 845 33-/4 826 32-/2 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 8

SOUND DATA Unit Model No. Octave Band Sound Power Levels dba, re 0-2 Watts Center Frequency - HZ 25 250 500 000 2000 4000 8000 Sound Rating Number (db) 220/240V - Single Phase Models TSA024S4 5.5 62 64.5 68.5 67 60.5 53.5 76 TSA030S4 52.5 62 67.5 69 67 6.5 54.5 76 TSA036S4 58 68 73.5 75.5 74 69.5 62.5 80 TSA048S4 57.5 67 73 74.5 7 64 58.5 80 TSA060S4 57 63 69.5 7.5 7 65.5 60.5 80 380/420V - Three Phase Models TSA036S4 52.5 6 67 69 67 6.5 52.5 80 TSA048S4 57.5 67 73 74.5 7 64 58.5 80 TSA060S4 57 63 69.5 7.5 7 65.5 60.5 80 NOTE - the octave sound power data does not include tonal correction. Tested according to Air-Conditioning, Heating and Refrigeration Institute (AHRI) Standard 270-95 test conditions. INSTALLATION CLEARANCES - MM (INCHES) See NOTES See NOTES See NOTES NOTES: Service clearance of 762 mm (30 in.) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 94 mm (36 in.) Clearance to one of the remaining two sides may be 305 mm (2 in.) and the final side may be 52 mm (6 in.). A clearance of 60 mm (24 in.) must be maintained between two units. 29 mm (48 in.) clearance required on top of unit. See NOTES CONTROL BOX 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 9

RATINGS - SINGLE PHASE Model Number Gross Cooling Capacity Net Cooling Capacity Power Input kw EER (Energy Efficiency Rating) COP (Coefficient of Perfomance) Output/Input Indoor Unit Model Number Expansion Device Required kw Btuh kw Btuh TSA024S4 7.0 23 800 6.6 22 600 2.0 0.75 3.5 BCRMA7924S005 37L5 TSA024S4 6.9 23 600 6.6 22 600 2.04.0 3.25 CX34-30A/B/C-6F Factory Installed TSA024S4 6.7 22 800 6.4 2 800 2.03 0.75 3.5 CR33-24B-F 37L5 TSA024S4 6.9 23 600 6.6 22 600 2.04.0 3.25 CH33-25B-2F 37L5 TSA030S4 8.4 28 500 8.0 27 200 2.47.00 3.22 BCRMA7924S005 37L5 TSA030S4 8.3 28 300 7.9 27 000 2.45.05 3.24 CX34-30A/B/C-6F Factory Installed TSA030S4 8.7 29 600 8.3 28 400 2.46.55 3.38 CR33-30/36B-F 37L5 TSA030S4 8.9 30 200 8.5 29 000 2.47.75 3.44 CH33-3B-2F 37L5 TSA036S4 0.5 35 900 9.9 33 800 3.3 0.20 2.99 BCRMB9937S005 37L5 TSA036S4 0.2 34 900 9.8 33 400 3.0 0.75 3.5 CX34-36B/C-6F Factory Installed TSA036S4 0.3 35 200 9.9 33 800 3. 0.90 3.9 CR33-30/36B-F 37L5 TSA036S4 0.2 34 800 9.8 33 400 3.0 0.75 3.5 CH33-36B-2F 37L5 TSA048S4 4.3 48 600 3.5 46 000 4.52 0.20 2.99 BCRMC9960S005 9M02 TSA048S4 4. 47 900 3.5 46 000 4.30 0.70 3.4 CX34-44/48C-6F Factory Installed TSA048S4 3.8 47 200 3.2 45 000 4.29 0.50 3.08 CR33-48C-F 9M02 TSA048S4 4.3 48 600 3.6 46 500 4.3 0.80 3.7 CH33-48C-2F 9M02 TSA060S4 5.8 53 700 4.8 50 500 4.82 0.50 3.08 BCRMD960S005 9M02 TSA060S4 6. 54 800 5.4 52 500 4.67.25 3.30 CX34-62D-6F Factory Installed TSA060S4 5.8 53 800 4.9 5 000 4.65.00 3.22 CR33-60D-F 9M02 TSA060S4 5.8 54 000 5. 5 500 4.65.0 3.25 CH33-60D-2F 9M02 Rating test conditions are those included in Air-Conditioning and Refrigeration Institute (ARI) Standard 20/240; 35 C (95 F) outdoor air temperature and 27 C (80 F) db/ (67 F) wb entering evaporator air; minimum external duct static pressure while operating at rated voltage and air volumes. All ratings include the use of a blower time delay relay (TDR). Furnaces and Air Handlers may require an optional time delay relay (58M8) for field installation. See furnace or air handler specifications to determine if relay is needed. RATINGS - THREE PHASE Model Number Gross Cooling Capacity Net Cooling Capacity 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 0 Power Input EER (Energy Efficiency Rating) COP (Coefficient of Perfomance) Output/Input Indoor Unit Model Number Expansion Device Required kw Btuh kw Btuh TSA036S4 0.0 34 200 9.4 32 200 3.28 9.85 2.89 BCRMB9937S3N5 37L5 TSA036S4 9.9 33 600 9.4 32 200 3.07 0.50 3.08 CX34-36B/C-6F Factory Installed TSA036S4 0.0 34 000 9.6 32 600 3.07 0.60 3. CR33-30/36B-F 37L5 TSA036S4 9.8 33 500 9.4 32 000 3.07 0.40 3.05 CH33-36B-2F 37L5 TSA048S4 4.2 48 300 3.3 45 500 4.42 0.30 3.02 BCRMC9960S4N5 9M02 TSA048S4 4.0 47 600 3.3 45 500 4.20 0.85 3.8 CX34-44/48C-6F Factory Installed TSA048S4 3.8 46 900 3.2 45 000 4.9 0.75 3.5 CR33-48C-F 9M02 TSA048S4 4.2 48 400 3.6 46 500 4.2.05 3.24 CH33-48C-2F 9M02 TSA060S4 7.9 6 00 7.0 58 000 5.85 9.90 2.90 BCRMD960S4N5 9M02 TSA060S4 8.3 62 400 7.6 60 000 5.7 0.50 3.08 CX34-62D-6F Factory Installed TSA060S4 7.9 6 000 7. 58 500 5.68 0.30 3.02 CR33-60D-F 9M02 TSA060S4 8.0 6 500 7.3 59 000 5.69 0.40 3.05 CH33-60D-2F 9M02 Rating test conditions are those included in Air-Conditioning and Refrigeration Institute (ARI) Standard 20/240; 35 C (95 F) outdoor air temperature and 27 C (80 F) db/ (67 F) wb entering evaporator air; minimum external duct static pressure while operating at rated voltage and air volumes. All ratings include the use of a blower time delay relay (TDR). Furnaces and Air Handlers may require an optional time delay relay (58M8) for field installation. See furnace or air handler specifications to determine if relay is needed.

EXPANDED RATINGS - SINGLE PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA024S4 Cooling Capacity with BCRMA7924S005 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 35 6.6.40.75.89.00 6.3.60.77.9.00 6.0.82.79.94.00 5.6 2.08.82.98.00 390 7.0.4.80.96.00 6.6.60.83.98.00 6.3.82.86.00.00 5.9 2.08.89.00.00 470 7.3.4.86.00.00 6.9.60.89.00.00 6.6.83.92.00.00 6.2 2.09.96.00.00 35 7.0.4.6.73.86 6.7.60.62.75.88 6.3.82.63.77.9 5.9 2.08.65.80.95 390 7.3.4.64.78.92 7.0.6.65.80.95 6.6.83.67.83.99 6.2 2.09.69.87.00 470 7.6.4.67.83.99 7.2.6.69.86.00 6.8.83.7.89.00 6.3 2.09.73.94.00 35 7.4.4.47.59.7 7.0.6.47.60.72 6.7.83.48.6.74 6.2 2.09.49.63.77 390 7.8.4.49.62.76 7.4.6.49.64.78 7.0.84.50.66.8 6.5 2.09.5.68.84 470 8.0.42.50.66.8 7.6.6.5.68.83 7.2.84.52.70.87 6.7 2.0.53.72.9 TSA024S4 Cooling Capacity with CX34-30A/B/C Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 330 6.7.40.77.9.00 6.4.60.79.93.00 6.0.82.8.97.00 5.6 2.07.84.00.00 380 6.9.4.80.95.00 6.6.60.82.98.00 6.2.82.85.00.00 5.8 2.08.88.00.00 425 7.0.4.83.98.00 6.7.60.85.00.00 6.4.83.88.00.00 6.0 2.09.92.00.00 330 7..4.62.75.87 6.7.60.63.77.90 6.4.83.64.79.93 5.9 2.08.66.82.97 380 7.3.4.64.78.9 6.9.6.65.80.94 6.5.83.67.82.98 6. 2.08.69.86.00 425 7.4.4.65.8.95 7.0.60.67.83.98 6.7.83.69.86.00 6.2 2.09.7.89.00 330 7.4.4.47.6.73 7.0.6.48.62.74 6.7.83.49.63.77 6.2 2.09.49.65.79 380 7.6.4.49.62.75 7.3.6.49.64.77 6.9.83.50.65.80 6.4 2.09.5.67.83 425 7.8.4.49.64.78 7.4.6.50.66.8 7.0.84.5.68.83 6.5 2.09.52.70.87 TSA024S4 Cooling Capacity with CR33-24B-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 330 6.4.40.76.89.99 6.2.59.77.9.00 5.8 80.80.94.00 5.5 2.07.82.97.00 380 6.6.40.78.93.00 6.3.60.80.95.00 6.0.82.82.98.00 5.7 2.08.86.00.00 425 6.9.40.8.96.00 6.5.60.83.98.00 6.2.82.86.00.00 5.8 2.08.89.00.00 330 6.9.40.6.74.86 6.6.60.62.75.88 6.2.82.63.77.9 5.7 2.08.65.80.94 380 7..4.63.76.90 6.7.60.64.78.92 6.3.82.65.80.95 5.9 2.08.67.83.98 425 7.2.4.64.79.93 6.8.60.65.8.96 6.4.83.67.83.98 6.0 2.08.69.87.00 330 7.3.4.48.60.7 6.9.60.48.6.73 6.6.83.49.62.75 6. 2.09.49.64.78 380 7.5.4.49.6.74 7.2.6.49.63.76 6.7.83.50.64.78 6.3 2.09.50.66.8 425 7.6.4.49.63.77 7.3.6.50.64.79 6.9.84.5.66.8 6.4 2.09.5.68.85 TSA024S4 Cooling Capacity with CH33-25B-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 330 6.9.4.78.93.00 6.6.60.80.95.00 6.2.82.82.98.00 5.7 2.08.86.00.00 380 7..4.82.97.00 6.7.60.84.99.00 6.4.83.86.00.00 6.0 2.08.90.00.00 425 7.3.4.85.00.00 6.9.60.87.00.00 6.6.83.90.00.00 6.2 2.09.94.00.00 330 7.3.4.62.76.89 6.9.60.63.78.92 6.5.83.65.80.95 6.0 2.09.67.83.98 380 7.4.4.64.79.94 7..6.66.8.96 6.7.83.67.84.99 6.2 2.09.69.87.00 425 7.6.4.66.82.98 7.2.6.68.85.00 6.8.83.70.88.00 6.3 2.09.72.92.00 330 7.6.4.47.6.73 7.2.6.48.62.75 6.8.83.49.63.78 6.3 2.09.50.65.8 380 7.8.4.48.63.77 7.4.6.49.64.79 7.0.84.50.66.82 6.5 2.0.5.68.85 425 8.0.42.50.65.80 7.6.6.50.67.83 7.2.84.5.69.85 6.6 2.0.52.7.89 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page

EXPANDED RATINGS - SINGLE PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA030S4 Cooling Capacity with BCRMA7924S005 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 355 8.0.67.74.87.99 7.6.90.76.89.00 7.2 2.7.78.92.00 6.7 2.48.80.96.00 445 8.4.68.79.94.00 8.0.9.8.97.00 7.5 2.8.84.99.00 7.0 2.49.87.00.00 535 8.7.69.84.99.00 8.3.92.86.00.00 7.9 2.9.89.00.00 7.4 2.50.93.00.00 355 8.4.68.60.72.84 8.0.9.6.74.86 7.6 2.8.62.75.89 7.0 2.49.63.78.92 445 8.8.69.63.77.9 8.4.93.64.79.93 7.9 2.20.66.8.97 7.4 2.50.68.84.99 535 9..7.66.82.97 8.7.94.67.84.99 8. 2.20.69.87.00 7.6 2.5.7.9.00 355 8.9.70.47.59.70 8.4.93.47.60.7 7.9 2.20.48.6.73 7.4 2.5.49.62.75 445 9.3.7.48.62.75 8.8.94.49.63.76 8.3 2.2.50.65.79 7.7 2.52.50.66.82 535 9.6.72.50.65.80 9..96.5.66.82 8.6 2.22.5.68.85 8.0 2.53.52.70.88 TSA030S4 Cooling Capacity with CX34-30A/B/C-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 355 8.0.67.74.87.99 7.6.90.76.89.00 7.2 2.7.78.92.00 6.7 2.48.80.96.00 445 8.4.68.79.94.00 8.0.9.8.97.00 7.5 2.8.84.99.00 7.0 2.49.87.00.00 535 8.7.69.84.99.00 8.3.92.86.00.00 7.9 2.9.89.00.00 7.4 2.50.93.00.00 355 8.4.68.60.72.84 8.0.9.6.74.86 7.6 2.8.62.75.89 7.0 2.49.63.78.92 445 8.8.69.63.77.9 8.4.93.64.79.93 7.9 2.20.66.8.97 7.4 2.50.68.84.99 535 9..7.66.82.97 8.7.94.67.84.99 8. 2.20.69.87.00 7.6 2.5.7.9.00 355 8.9.70.47.59.70 8.4.93.47.60.7 7.9 2.20.48.6.73 7.4 2.5.49.62.75 445 9.3.7.48.62.75 8.8.94.49.63.76 8.3 2.2.50.65.79 7.7 2.52.50.66.82 535 9.6.72.50.65.80 9..96.5.66.82 8.6 2.22.5.68.85 8.0 2.53.52.70.88 TSA030S4 Cooling Capacity with CR33-30/36B-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 400 8.5.69.79.93.00 8.0.92.80.95.00 7.6 2.8.83.98.00 7. 2.49.86.00.00 470 8.7.69.83.98.00 8.3.92.85.00.00 7.9 2.9.87.00.00 7.4 2.50.9.00.00 545 9.0.70.87.00.00 8.6.93.89.00.00 8. 2.2.92.00.00 7.6 2.5.95.00.00 400 8.9.70.62.76.90 8.4.93.63.78.92 8.0 2.20.65.80.95 7.4 2.50.67.83.98 470 9..7.65.8.95 8.7.94.66.83.97 8. 2.20.68.85.00 7.6 2.5.70.88.00 545 9.4.7.67.84.99 8.9.94.69.87.00 8.4 2.2.7.90.00 7.8 2.52.73.93.00 400 9.4.7.48.6.74 8.9.95.48.62.76 8.4 2.2.49.64.78 7.8 2.52.50.66.8 470 9.6.72.49.64.78 9..96.49.65.80 8.6 2.22.50.67.83 8.0 2.53.5.69.86 545 9.8.73.50.66.82 9.3.96.5.68.85 8.7 2.23.52.70.87 8. 2.53.53.72.9 TSA030S4 Cooling Capacity with 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 2 CH33-3B-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 400 8.6.69.78.93.00 8..92.80.95.00 7.7 2.9.82.98.00 7.2 2.49.85.00.00 470 8.9.70.82.98.00 8.4.93.84.00.00 8.0 2.20.87.00.00 7.5 2.5.90.00.00 545 9..7.86.00.00 8.7.94.88.00.00 8.3 2.2.9.00.00 7.7 2.52.95.00.00 400 9.0.70.62.76.89 8.6.94.63.78.92 8. 2.20.65.80.95 7.5 2.5.66.83.98 470 9.3.7.63.80.95 8.9.95.66.82.97 8.3 2.2.67.85.00 7.7 2.52.70.88.00 545 9.6.72.67.84.99 9..95.68.86.00 8.5 2.22.70.89.00 7.9 2.53.73.93.00 400 9.5.72.47.6.73 9.0.95.48.62.75 8.5 2.22.49.63.78 7.9 2.52.50.65.80 470 9.8.73.49.63.78 9.3.96.49.65.80 8.7 2.23.50.66.82 8. 2.53.5.69.86 545 0.0.74.49.66.8 9.5 970.49.67.84 8.9 2.24.5.69.87 8.3 2.54.52.72.9

EXPANDED RATINGS - SINGLE PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA036S4 Cooling Capacity with BCRMB9937S005 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 455 0.0 2.09.76.89.00 9.4 2.40.78.9.00 8.9 2.74.80.94.00 8.3 3.4.83.98.00 570 0.4 2.0.8.96.00 9.9 2.4.83.98.00 9.4 2.75.86.00.00 8.8 3.5.89.00.00 685 0.9 2..85.00.00 0.4 2.42.88.00.00 9.8 2.76.9.00.00 9.3 3.6.95.00.00 455 0.6 2.0.6.73.86 0. 2.4.62.75.88 9.5 2.76.64.77.9 8.9 3.6.65.80.95 570. 2.2.64.78.92 0.6 2.42.66.8.95 9.8 2.77.67.83.98 9. 3.7.69.87.00 685.4 2.2.67.83.98 0.8 2.42.69.86.00 0. 2.77.7.89.00 9.4 3.7.73.93.00 455.3 2.2.47.60.7 0.7 2.42.48.6.73 0.0 2.77.49.62.75 9.4 3.7.49.64.78 570.7 2.3.49.63.76. 2.43.50.64.78 0.4 2.78.5.66.8 9.7 3.8.52.68.84 685 2.2 2.4.5.66.8.4 2.44.52.68.84 0.7 2.79.53.70.87 0.0 3.9.54.72.9 TSA036S4 Cooling Capacity with CX34-36B/C-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 9.9 2.09.77.9.00 9.4 2.39.79.93.00 8.8 2.74.8.96.00 8.3 3.4.84.99.00 565 0.3 2.0.8.96.00 9.7 2.40.83.98.00 9. 2.75.86.00.00 8.6 3.5.89.00.00 660 0.6 2.0.85.00.00 0. 2.4.87.00.00 9.6 2.76.90.00.00 9.0 3.6.94.00.00 470 0.4 2.0.62.75.87 9.8 2.40.63.77.90 9.3 2.75.64.79.93 8.7 3.5.66.82.96 565 0.8 2..64.78.93 0.3 2.4.65.8.96 9.6 2.76.67.83.98 9.0 3.6.69.86.00 660. 2.2.67.83.98 0.5 2.42.68.85.00 9.8 2.77.70.88.00 9. 3.6.72.92.00 470 0.9 2..48.60.72 0.3 2.42.48.6.74 9.7 2.76.49.63.76 9. 3.6.50.65.79 565.3 2.2.49.63.76 0.7 2.42.49.64.78 0. 2.77.50.66.8 9.4 3.7.5.68.84 660.7 2.3.50.65.80.0 2.43.5.67.83 0.4 2.78.5.69.86 9.7 3.7.53.7.90 TSA036S4 Cooling Capacity with CR33-30/36B-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 0.0 2.09.77.9.00 9.4 2.40.79.93.00 8.9 2.74.8.96.00 8.3 3.4.84.99.00 565 0.4 2.0.8.96.00 9.8 2.40.83.98.00 9.3 2.75.86.00.00 8.7 3.5.89.00.00 660 0.7 2..86.00.00 0. 2.4.88.00.00 9.6 2.76.9.00.00 9.0 3.6.94.00.00 470 0.6 2.0.6.75.88 0.0 2.4.63.76.90 9.4 2.75.64.79.93 8.8 3.5.66.82.96 565.0 2..64.79.93 0.3 2.4.65.8.96 9.7 2.76.67.84.98 9.0 3.6.69.87.00 660.3 2.2.67.83.98 0.6 2.42.68.86.00 0.0 2.77.70.89.00 9.3 3.6.73.92.00 470. 2.2.47.60.72 0.6 2.42.48.6.74 0.0 2.77.48.63.76 9.3 3.7.49.64.79 565.6 2.2.48.62.76 0.9 2.43.49.64.79 0.3 2.78.50.66.8 9.6 3.8.5.68.85 660.9 2.3.50.66.8.3 2.44.5.67.83 0.6 2.78.52.69.86 9.8 3.8.53.72.90 TSA036S4 Cooling Capacity with CH33-36B-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 9.9 2.09.77.9.00 9.3 2.39.79.93.00 8.8 2.74.8.96.00 8.2 3.4.84.99.00 565 0.3 2.0.8.96.00 9.7 2.40.83.98.00 9. 2.75.85.00.00 8.6 3.5.89.00.00 660 0.6 2.0.85.00.00 0. 2.4.87.00.00 9.5 2.76.90.00.00 8.9 3.6.94.00.00 470 0.4 2.0.62.75.87 9.8 2.40.63.76.90 9.3 2.75.64.79.93 8.7 3.5.66.8.96 565 0.8 2..64.78.93 0.2 2.4.65.80.95 9.6 2.76.67.83.98 8.9 3.6.69.86.00 660. 2.2.66.82.98 0.5 2.42.68.85.00 9.8 2.77.70.88.00 9. 3.6.72.92.00 470 0.8 2..47.60.72 0.3 2.42.48.6.74 9.7 2.76.49.63.76 9. 3.6.49.64.79 565.3 2.2.48.62.76 0.7 2.42.49.64.78 0. 2.77.50.65.80 9.4 3.7.5.68.84 660.7 2.3.50.65.80.0 2.43.5.67.83 0.4 2.78.52.69.86 9.7 3.8.53.7.89 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 3

EXPANDED RATINGS - SINGLE PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA048S4 Cooling Capacity with BCRMC9960S005 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 575 3.5 3.03.75.88.99 2.7 3.4.77.90.00 2.0 3.84.79.93.00. 4.34.82.97.00 75 4.2 3.06.80.95.00 3.5 3.44.82.98.00 2.6 3.87.85.00.00.9 4.38.88.00.00 860 4.7 3.08.85.00.00 4. 3.47.88.00.00 3.3 3.9.9.00.00 2.5 4.42.95.00.00 575 4.4 3.07.6.73.85 3.6 3.45.62.74.87 2.7 3.88.63.77.90.9 4.38.65.79.94 75 5. 3.0.64.78.9 4.2 3.48.65.80.94 3.3 3.92.67.82.98 2.5 4.4.69.86.00 860 5.5 3.2.67.83.98 4.7 3.50.68.85.00 3.8 3.94.70.89.00 2.7 4.43.73.93.00 575 5. 3..47.59.70 4.4 3.49.47.60.72 3.6 3.92.47.6.74 2.6 4.42.48.63.77 75 5.8 3.4.49.62.75 5. 3.52.49.64.78 4.2 3.96.50.65.80 3.2 4.46.5.68.84 860 6.4 3.7.5.66.80 5.5 3.55.5.67.83 4.5 3.98.52.69.86 3.5 4.48.53.72.9 TSA048S4 Cooling Capacity with CX34-44/48C-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.6 3.03.76.89.00 2.9 3.4.77.92.00 2.2 3.85.80.95.00.3 4.35.83.98.00 755 4. 3.05.78.93.00 3.3 3.43.8.96.00 2.5 3.86.83.99.00.6 4.36.86.00.00 850 4.4 3.07.8.97.00 3.6 3.44.84.99.00 2.7 3.88.86.00.00 2.0 4.39.90.00.00 660 4.5 3.07.60.73.86 3.8 3.45.6.75.88 2.9 3.89.63.77.9 2.0 4.39.65.80.95 755 4.8 3.09.62.76.90 4. 3.47.63.78.93 3.2 3.90.65.8.96 2.3 4.40.67.84.99 850 5. 3..64.79.93 4.4 3.49.65.8.96 3.5 3.92.67.84.99 2.5 4.42.69.88.00 660 5.2 3..47.59.7 4.5 3.49.47.60.73 3.6 3.93.48.6.75 2.7 4.43.49.63.78 755 5.7 3.3.48.6.74 4.8 3.5.48.62.76 3.9 3.95.49.64.78 3.0 4.45.50.66.8 850 6.0 3.4.48.63.76 5. 3.53.49.64.79 4.2 3.97.50.66.82 3.2 4.46.5.68.85 TSA048S4 Cooling Capacity with CR33-48C-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.5 3.02.77.90.00 2.7 3.4.78.93.00 2.0 3.84.80.95.00. 4.34.83.99.00 755 3.8 3.04.79.94.00 3.0 3.42.8.96.00 2.3 3.86.84.99.00.6 4.36.87.00.00 850 4. 3.05.82.97.00 3.3 3.43.84.99.00 2.6 3.87.87.00.00.9 4.38.9.00.00 660 4.2 3.06.6.74.87 3.5 3.44.62.76.89 2.7 3.88.64.78.92.9 4.38.65.8.96 850 4.5 3.08.63.77.90 3.8 3.46.64.79.93 3.0 3.89.66.8.96 2.2 4.40.68.84.99 850 4.8 3.09.65.79.94 4. 3.47.66.82.97 3.3 3.9.68.84.99 2.3 4.4.70.88.00 660 4.9 3.0.46.60.72 4.2 3.48.47.6.74 3.5 3.92.48.62.76 2.6 4.42.49.64.78 755 5.4 3.2.48.62.75 4.5 3.50.48.63.76 3.8 3.93.49.65.79 2.7 4.43.50.67.82 850 5.7 3.3.49.64.77 4.8 3.5.49.65.79 4. 3.95.50.67.82 3.0 4.45.5.69.86 TSA048S4 Cooling Capacity with 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 4 CH33-48C-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.8 3.04.76.90.00 3.2 3.42.78.93.00 2.3 3.86.80.96.00.4 4.36.83.99.00 755 4.2 3.06.79.94.00 3.5 3.44.8.97.00 2.6 3.87.84.00.00.9 4.38.87.00.00 850 4.5 3.08.82.98.00 3.8 3.46.84.00.00 3.0 3.89.87.00.00 2.2 4.40.9.00.00 660 4.7 3.08.6.74.87 3.9 3.46.62.76.89 3.0 3.90.63.78.92 2.2 4.39.65.8.96 850 5. 3.0.62.77.9 4.2 3.48.64.79.94 3.3 3.92.65.8.97 2.5 4.4.67.85.00 850 5.4 3.2.64.80.95 4.5 3.50.66.82.97 3.6 3.93.68.85.00 2.6 4.43.70.89.00 660 5.4 3.2.47.59.72 4.7 3.50.47.60.73 3.8 3.94.48.62.75 2.9 4.44.49.64.78 755 5.8 3.4.48.6.74 5. 3.52.48.62.76 4.2 3.96.49.64.79 3.2 4.46.50.66.82 850 6. 3.6.49.63.77 5.4 3.54.49.65.80 4.4 3.97.50.66.82 3.3 4.47.5.69.86

EXPANDED RATINGS - SINGLE PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA060S4 Cooling Capacity with BCRMD960S005 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 640 4.9 3.9.75.89.00 4.2 3.60.77.9.00 3.3 4.06.79.94.00 2.3 4.59.82.97.00 800 5.7 3.22.8.96.00 4.8 3.63.83.98.00 3.9 4.0.86.00.00 3.2 4.64.89.00.00 960 6.3 3.25.86.00.00 5.5 3.67.89.00.00 4.8 4.4.92.00.00 3.8 4.68.96.00.00 640 5.8 3.23.6.73.85 5. 3.64.62.75.88 4. 4.0.63.77.9 3.2 4.64.65.80.94 800 6.7 3.27.64.79.92 5.8 3.68.65.8.95 4.8 4.4.67.84.98 3.8 4.67.69.87.00 960 7. 3.30.67.84.99 6.3 3.70.69.87.00 5.2 4.7.7.90.00 4. 4.69.74.94.00 640 6.9 3.28.47.59.70 6.0 3.69.48.60.72 4.9 4.5.48.6.74 3.9 4.68.49.63.77 800 7.7 3.32.49.63.76 6.7 3.73.49.64.78 5.7 4.20.50.66.8 4.5 4.72.5.68.85 960 8.3 3.35.50.66.82 7.3 3.76.5.68.85 6.3 4.22.52.70.88 4.9 4.74.54.73.92 TSA060S4 Cooling Capacity with CX34-62D-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 4.9 3.9.76.89.00 4.2 3.60.77.9.00 3.3 4.07.79.94.00 2.5 4.60.82.98.00 755 5.4 3.2.78.93.00 4.7 3.62.80.96.00 3.8 4.09.83.99.00 2.9 4.62.86.00.00 850 5.8 3.23.8.97.00 4.9 3.64.84.99.00 4. 4..86.00.00 3.3 4.65.90.00.00 660 5.8 3.23.60.73.86 4.9 3.64.6.75.88 4.2 4..63.77.9 3.2 4.64.65.80.95 755 6.3 3.25.62.76.89 5.4 3.66.63.78.92 4.5 4.3.65.80.96 3.5 4.66.67.84.99 850 6.7 3.27.64.79.93 5.8 3.68.65.8.96 4.8 4.5.67.84.99 3.8 4.67.69.87.00 660 6.7 3.27.46.59.7 5.8 3.69.47.60.72 4.9 4.5.47.6.74 3.9 4.68.48.63.77 755 7. 3.30.47.60.74 6.3 3.7.48.62.76 5.4 4.8.49.64.78 4.4 4.7.50.66.8 850 7.6 3.32.48.63.77 6.7 3.73.49.64.79 5.7 4.9.50.66.82 4.5 4.72.5.68.85 TSA060S4 Cooling Capacity with CR33-60D-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 4.8 3.8.76.90.00 3.9 3.59.78.92.00 3.2 4.06.80.95.00 2.2 4.59.83.98.00 755 5. 3.20.79.94.00 4.4 3.6.8.96.00 3.5 4.07.84.99.00 2.6 4.6.87.00.00 850 5.5 3.2.82.97.00 4.7 3.62.84.99.00 3.9 4.09.87.00.00 3.0 4.63.9.00.00 660 5.5 3.22.6.74.86 4.8 3.63.62.76.89 3.9 4.0.63.78.92 2.9 4.63.65.8.95 755 6.0 3.24.63.77.9 5.2 3.65.64.79.93 4.4 4.2.65.8.96 3.3 4.65.67.85.99 850 6.4 3.25.65.80.94 5.5 3.67.66.82.97 4.5 4.3.68.85.99 3.5 4.66.70.89.00 660 6.4 3.25.46.59.7 5.5 3.67.47.60.73 4.7 4.4.47.62.75 3.8 4.67.48.64.78 755 6.9 3.28.47.6.74 6.0 3.69.48.63.76 5. 4.6.48.64.79 4. 4.69.49.66.82 850 7.3 3.30.48.63.77 6.4 3.7.49.65.80 5.4 4.7.50.67.82 4.4 4.70.5.69.86 TSA060S4 Cooling Capacity with CH33-60D-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 4.7 3.8.75.88.00 3.9 3.59.76.90.00 3.2 4.06.79.93.00 2.2 4.58.8.97.00 755 5. 3.20.77.92.00 4.4 3.6.79.94.00 3.5 4.07.82.98.00 2.6 4.60.85.00.00 850 5.5 3.2.80.96.00 4.7 3.63.82.98.00 3.8 4.09.85.00.00 2.9 4.63.88.00.00 660 5.7 3.22.60.72.85 4.8 3.63.6.74.87 3.9 4.0.62.76.90 3.0 4.63.64.79.93 755 6. 3.24.62.75.88 5.2 3.65.63.77.9 4.4 4.2.64.79.94 3.3 4.65.66.82.98 850 6.4 3.26.63.78.92 5.5 3.67.64.80.95 4.7 4.3.66.83.98 3.6 4.66.68.86.00 660 6.6 3.26.46.58.70 5.7 3.67.47.59.7 4.8 4.4.47.6.74 3.8 4.67.48.62.76 755 7.0 3.28.47.60.73 6. 3.69.48.6.75 5. 4.6.48.63.77 4. 4.69.49.65.80 850 7.3 3.30.48.62.76 6.4 3.72.48.63.78 5.4 4.8.49.65.80 4.4 4.7.50.67.84 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 5

EXPANDED RATINGS - three PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA036S4 Cooling Capacity with BCRMB9937S3N5 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 455 9.6 2.6.76.89.00 9. 2.45.77.9.00 8.6 2.78.79.94.00 8. 3.7.82.96.00 570 0. 2.7.8.96.00 9.6 2.46.83.98.00 9. 2.80.85.00.00 8.6 3.9.88.00.00 685 0.4 2.8.85.00.00 0.0 2.48.88.00.00 9.5 2.82.90.00.00 8.9 3.2.94.00.00 455 0.2 2.7.62.74.86 9.7 2.47.62.75.88 9. 2.80.64.77.9 8.5 3.9.65.79.94 570 0.6 2.9.64.79.93 0.0 2.48.66.8.95 9.4 2.82.67.83.98 8.8 3.20.69.86.00 685 0.9 2.20.67.84.99 0.3 2.49.69.86.00 9.7 2.82.70.89.00 9.0 3.2.73.92.00 455 0.7 2.9.48.60.72 0.2 2.49.48.6.73 9.6 2.82.49.62.75 9.0 3.2.50.64.77 570. 2.2.50.63.77 0.6 2.50.50.65.79 0.0 2.84.5.66.8 9.3 3.23.52.68.84 685.4 2.22.5.66.82 0.8 2.5.52.68.84 0.2 2.84.53.70.87 9.5 3.24.54.72.90 TSA036S4 Cooling Capacity with CX34-36B/C-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 9.6 2.5.77.9.00 9. 2.45.79.93.00 8.6 2.79.8.96.00 8. 3.7.83.99.00 565 9.9 2.6.8.96.00 9.4 2.46.83.98.00 8.9 2.79.85.00.00 8.5 3.9.00.00.00 660 0.3 2.8.85.00.00 9.8 2.47.88.00.00 9.3 2.8.90.00.00 8.5 3.9.00.00.00 470 0.0 2.7.62.75.88 9.6 2.46.63.77.90 9.0 2.80.64.79.93 8.4 3.9.66.8.96 565 0.4 2.8.64.79.93 9.8 2.47.65.8.96 9.3 2.8.67.83.98 8.6 3.9.96.96.96 660 0.7 2.9.67.83.98 0. 2.48.68.86.00 9.5 2.82.70.88.00 8.6 3.9.96.96.96 470 0.4 2.8.48.6.73 0.0 2.48.48.62.75 9.4 2.82.49.63.77 8.6 3.9.96.96.96 565 0.8 2.20.49.63.77 0.3 2.49.49.64.79 9.7 2.83.50.66.8 8.6 3.9.96.96.96 660. 2.2.50.66.8 0.6 2.50.5.68.84 0.0 2.84.52.69.87 8.6 3.9.96.96.96 TSA036S4 Cooling Capacity with CR33-30/36B-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 9.7 2.6.77.9.00 9.3 2.45.79.93.00 8.7 2.79.8.96.00 8.2 3.8.84.99.00 565 0. 2.7.8.96.00 9.6 2.46.83.98.00 9.0 2.80.86.00.00 8.6 3.9.00.00.00 660 0.3 2.8.86.00.00 9.8 2.47.88.00.00 9.3 2.8.9.00.00 8.6 3.9.00.00.00 470 0.2 2.7.62.75.88 9.7 2.47.63.77.90 9. 2.80.64.79.93 8.6 3.9.66.82.96 565 0.5 2.9.64.79.93 0.0 2.48.65.8.96 9.4 2.8.67.84.98 8.7 3.20.96.96.96 660 0.8 2.9.67.84.98 0.2 2.49.69.86.00 9.6 2.82.7.89.00 8.7 3.20.96.96.96 470 0.7 2.9.47.60.73 0.2 2.49.48.62.75 9.6 2.83.49.63.77 8.7 3.20.96.96.96 565.0 2.20.49.63.77 0.5 2.50.49.64.79 9.9 2.84.50.66.82 8.7 3.20.96.96.96 660.3 2.2.5.66.82 0.7 2.50.5.68.84 0. 2.84.52.70.87 8.7 3.20.96.96.96 TSA036S4 Cooling Capacity with 50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 6 CH33-36B-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 470 9.6 2.5.77.9.00 9. 2.45.79.93.00 8.6 2.78.8.96.00 8. 3.7.83.98.00 565 9.9 2.6.8.96.00 9.4 2.46.83.98.00 8.9 2.79.85.00.00 8.5 3.8.00.00.00 660 0.2 2.8.85.00.00 9.7 2.47.87.00.00 9.3 2.8.90.00.00 8.5 3.8.00.00.00 470 0.0 2.7.62.75.88 9.6 2.46.63.77.90 9.0 2.80.64.79.93 8.4 3.9.66.8.96 565 0.4 2.8.64.79.93 9.8 2.48.65.8.95 9.3 2.8.67.83.98 8.6 3.20.96.96.96 660 0.6 2.9.67.83.98 0. 2.48.68.85.00 9.5 2.82.70.88.00 8.6 3.20.96.96.96 470 0.4 2.8.48.6.73 9.9 2.48.48.62.74 9.4 2.8.49.63.77 8.6 3.20.96.96.96 565 0.8 2.20.49.63.77 0.3 2.49.49.64.79 9.7 2.83.50.66.8 8.6 3.20.96.96.96 660. 2.2.50.66.8 0.6 2.50.5.67.83 9.9 2.84.52.69.86 8.6 3.20.96.96.96

EXPANDED RATINGS - three PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA048S4 Cooling Capacity with BCRMC9960S4N5 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 575 3.5 2.9.75.88.99 2.7 3.33.77.9.00 2.0 3.79.79.93.00. 4.27.82.97.00 75 4. 2.93.80.95.00 3.3 3.35.82.98.00 2.6 3.80.85.00.00.9 4.30.89.00.00 860 4.7 2.95.85.00.00 3.9 3.37.88.00.00 3.2 3.83.9.00.00 2.5 4.32.95.00.00 575 4.2 2.93.6.73.85 3.5 3.36.62.75.87 2.7 3.8.63.77.90.9 4.30.65.79.94 75 4.9 2.96.64.78.92 4.2 3.38.65.80.95 3.3 3.83.67.83.98 2.5 4.32.69.86.00 860 5.4 2.98.67.83.98 4.7 3.39.69.86.00 3.8 3.85.7.89.00 2.7 4.32.73.93.00 575 5. 2.96.47.59.7 4.2 3.38.47.60.72 3.5 3.84.48.6.74 2.6 4.32.49.63.77 75 5.7 2.99.49.63.76 4.9 3.40.49.64.78 4. 3.86.50.66.80 3.2 4.34.5.68.84 860 6.3 3.0.5.66.8 5.4 3.42.5.68.83 4.5 3.87.52.70.86 3.5 4.35.53.72.9 TSA048S4 Cooling Capacity with CX34-44/48C-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.6 2.9.76.90.00 2.9 3.33.78.92.00 2.2 3.79.80.95.00.3 4.28.83.98.00 755 3.9 2.93.78.93.00 3.2 3.34.8.96.00 2.5 3.80.83.99.00.6 4.28.86.00.00 850 4.2 2.93.8.97.00 3.5 3.35.84.99.00 2.7 3.8.86.00.00.9 4.30.90.00.00 660 4.4 2.94.6.73.86 3.6 3.36.62.75.89 2.9 3.82.63.77.92 2.0 4.30.65.80.95 755 4.8 2.95.62.76.90 3.9 3.37.64.78.93 3.2 3.82.65.8.96 2.2 4.3.67.84.99 850 5. 2.96.64.79.94 4.2 3.38.66.8.96 3.3 3.83.67.84.99 2.5 4.32.69.88.00 660 5. 2.96.47.59.7 4.4 3.38.47.60.73 3.6 3.84.48.62.75 2.6 4.33.49.63.78 755 5.5 2.98.48.6.74 4.8 3.40.48.62.76 3.9 3.85.49.64.79 2.9 4.34.50.66.82 850 5.8 2.99.48.63.77 5. 3.4.49.64.79 4.2 3.86.50.66.82 3.2 4.34.5.68.85 TSA048S4 Cooling Capacity with CR33-48C-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.3 2.90.77.90.00 2.7 3.33.78.93.00 2.0 3780.8.96.00. 4.27.83.99.00 755 3.8 2.92.79.94.00 3.0 3.34.8.97.00 2.3 3.79.84.99.00.4 4.28.87.00.00 850 3.9 2.92.82.97.00 3.3 3.35.84.99.00 2.6 3.8.87.00.00.9 4.30.9.00.00 660 4.2 2.93.6.74.87 3.5 3.35.62.76.89 2.7 3.8.64.78.92.9 4.30.65.8.96 755 4.5 2.94.63.77.9 3.8 3.36.64.79.93 3.0 3.82.66.8.96 2.2 4.30.68.85.99 850 4.8 2.95.65.80.94 4. 3.37.66.82.97 3.2 3.83.68.85.99 2.3 4.3.70.88.00 660 4.9 2.96.46.60.72 4.2 3.38.47.6.74 3.3 3.83.48.62.76 2.6 4.32.49.64.78 755 5.2 2.97.48.62.75 4.5 3.39.48.63.77 3.6 3.84.49.65.79 2.7 4.33.50.67.82 850 5.5 2.98.49.64.77 4.8 3.40.49.65.80 3.9 3.85.50.67.82 3.0 4.34.5.69.86 TSA048S4 Cooling Capacity with CH33-48C-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 3.8 2.92.76.90.00 3.0 3.34.78.93.00 2.3 3.80.80.96.00.4 4.28.83.99.00 755 4.2 2.93.79.94.00 3.5 3.35.82.97.00 2.6 3.8.84.00.00.7 4.29.87.00.00 850 4.5 2.94.82.98.00 3.8 3.36.85.00.00 2.9 3.82.87.00.00 2.2 4.3.9.00.00 660 4.7 2.95.6.74.87 3.9 3.37.62.76.89 3.0 3.82.63.78.93 2.2 4.30.65.8.96 755 4.9 2.96.62.77.9 4.2 3.38.64.79.94 3.3 3.83.66.82.97 2.5 4.32.67.85.00 850 5.2 2.97.65.80.95 4.5 3.39.66.82.98 3.6 3.84.68.85.00 2.6 4.32.70.89.00 660 5.4 2.97.47.59.72 4.5 3.39.47.60.73 3.8 3.85.48.62.76 2.9 4.33.49.64.78 755 5.7 2.99.48.6.75 4.9 3.40.48.63.77 4. 3.86.49.64.79 3.2 4.34.50.66.82 850 6. 3.00.49.63.77 5.2 3.4.49.65.80 4.4 3.87.50.67.83 3.3 4.35.5.69.86

EXPANDED RATINGS - three PHASE MODELS NOTE For s and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. TSA060S4 Cooling Capacity with BCRMD960S4N5 Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 640 7.0 4.09.72.84.95 6. 4.58.73.86.97 5. 5.4.75.88.99 4.2 5.75.77.9.00 800 7.9 4.5.76.90.00 7.0 4.64.78.92.00 6.0 5.9.8.95.00 4.8 5.8.83.98.00 960 8.6 4.9.8.96.00 7.6 4.69.83.98.00 6.6 5.24.86.00.00 5.5 5.87.90.00.00 640 8.0 4.5.58.70.80 7.0 4.65.59.7.82 6. 5.2.60.73.85 4.9 5.83.62.75.88 800 8.9 4.22.6.74.87 7.9 4.7.62.76.89 6.9 5.27.64.78.92 5.7 5.88.66.8.96 960 9.6 4.26.64.79.93 8.6 4.76.66.8.96 7.4 5.3.67.84.98 6. 5.93.69.87.00 640 9.0 4.22.46.57.67 8.0 4.72.46.58.69 7.0 5.28.47.59.70 5.8 5.90.47.60.72 800 9.9 4.29.47.60.72 8.9 4.78.48.6.74 7.9 5.34.49.62.76 6.6 5.96.49.64.79 960 20.7 4.33.49.63.77 9.6 4.83.49.64.79 8.5 5.39.50.66.82 7. 6.00.5.69.85 TSA060S4 Cooling Capacity with CX34-62D-6F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 7.0 4.09.72.84.95 6.3 4.59.73.86.98 5.2 5.4.75.88.00 4.2 5.76.77.92.00 755 7.6 4.3.74.87.99 6.7 4.62.76.90.00 5.7 5.8.78.92.00 4.7 5.79.80.96.00 850 8.0 4.5.77.9.00 7. 4.65.79.93.00 6. 5.2.8.96.00 4.9 5.82.84.00.00 660 8.0 4.5.58.70.8 7. 4.65.59.7.83 6. 5.2.60.73.85 5. 5.82.6.75.88 755 8.5 4.9.60.72.84 7.6 4.69.6.74.86 6.6 5.24.62.76.89 5.4 5.86.64.78.93 850 8.9 4.22.6.75.87 8.0 4.7.62.76.90 6.9 5.27.64.79.93 5.8 5.89.66.8.97 660 8.9 4.2.45.57.67 8.0 4.72.46.57.69 7.0 5.27.46.58.70 5.8 5.90.47.60.73 755 9.5 4.25.46.58.70 8.5 4.75.47.59.7 7.4 5.3.47.60.73 6.3 5.93.48.62.76 850 9.9 4.28.47.60.73 8.9 4.78.47.6.74 7.9 5.34.48.63.76 6.6 5.96.49.64.79 TSA060S4 Cooling Capacity with CR33-60D-F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 6.7 4.07.73.85.96 5.8 4.56.74.87.98 4.9 5.2.76.89.00 3.9 5.74.78.93.00 755 7. 4.0.75.88.99 6.3 4.60.77.9.00 5.4 5.5.79.94.00 4.4 5.76.82.97.00 850 7.6 4.3.78.92.00 6.7 4.62.80.94.00 5.7 5.8.82.97.00 4.7 5.79.85.99.00 660 7.6 4.3.58.70.82 6.7 4.63.59.72.84 5.8 5.8.60.73.86 4.8 5.80.62.76.89 755 8.0 4.6.60.73.85 7. 4.66.6.75.87 6.3 5.22.62.77.90 5. 5.83.64.79.94 850 8.5 4.9.62.76.89 7.6 4.69.63.77.9 6.6 5.24.64.80.94 5.4 5.86.66.83.97 660 8.5 4.9.45.57.68 7.6 4.68.46.58.69 6.6 5.25.46.59.7 5.5 5.86.47.60.73 755 9.0 4.22.46.59.7 8.0 4.72.46.60.72 7.0 5.27.47.6.74 6.0 5.90.48.63.77 850 9.3 4.25.47.6.73 8.5 4.75.47.62.75 7.4 5.3.48.63.78 6.3 5.93.49.65.80 TSA060S4 Cooling Capacity with CH33-60D-2F Air Comp. Sensible To Comp. Sensible To Comp. Sensible To Comp. Sensible To 660 6.7 4.07.7.83.95 5.8 4.57.73.85.97 4.9 5.3.74.87.99 3.9 5.74.77.90.00 755 7.3 4.0.74.86.98 6.4 4.60.75.88.00 5.4 5.5.77.9.00 4.4 5.77.80.95.00 850 7.6 4.3.76.90.00 6.7 4.62.78.92.00 5.7 5.8.80.95.00 4.7 5.79.83.98.00 660 7.7 4.3.58.69.80 6.9 4.63.59.70.82 5.8 5.9.60.72.84 4.8 5.80.6.74.87 755 8.2 4.7.59.7.83 7.3 4.67.60.73.85 6.3 5.22.6.75.88 5.2 5.85.63.77.9 850 8.6 4.20.6.74.86 7.7 4.69.62.75.89 6.7 5.25.63.77.92 5.5 5.86.65.80.95 660 8.6 4.20.45.56.67 7.7 4.70.46.57.68 6.7 5.26.46.58.69 5.7 5.87.47.59.72 755 9.2 4.23.46.58.69 8.2 4.73.46.59.70 7. 5.29.47.60.72 6.0 5.9.48.6.75 850 9.6 4.26.47.59.7 8.6 4.76.47.60.73 7.6 5.32.48.62.75 6.4 5.93.48.63.78

50 hz T-Class Air Conditioners 7 to 7.6 kw / Page 9

Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 800 4 LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2009 Lennox Industries, Inc.