ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Similar documents
Mark 25 Ultrapure Water Conductivity Analyzer

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Tachometer/Hourmeter/Trip. Installation and Operation Manual

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Indoor/Outdoor Temperature Alert

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Digital Marine Exhaust Temperature Alarm

Carbon Monoxide Transmitter

VE.NET GMDSS PANEL USER MANUAL INSTALLATION MANUAL

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Global Water Instrumentation, Inc.

CLEANROOM MONITOR CR3A Network - Installation Instructions

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Fire Command Keypad. XR5 User s Guide

Beacon 410A Gas Monitor Operator s Manual

CA5000 Liquid CO 2 Freezer Backup System

HIn3550 Magnetic Field Monitor User's Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

WARNING Important Safety Information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

Explorer F210 Fuel Instrument Installation and Operation Manual

Warranty Registration

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Blaze INFO-2. Information Display

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

WARNING Important Safety Information

USER MANUAL FOR OPERATING SYSTEM

G D G D. Handbook. Handbook. Warranty

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual

U ser's Guide PC6010

Beacon 800 Gas Monitor Operator s Manual

Model SS2000C31 SmartSystem Load Management System

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Installation and Operation Manual

Bacharach Bodyguard 4 User's Guide

FIRERAY 5000 range USER GUIDE

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

THX-DL Data Logger USER & INSTALLATION MANUAL V

M2 Rig Monitor Operator s Manual

780 Keypad Demonstrator Module

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Oakton TEMP 9500 Advanced Multiparameter Controller

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

D3000. Installation & Setup Guide

RTD TEMPERATURE SENSING SYSTEM

FLOW CONTROLLER TYPE S/601

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

CASS9000 Standalone FingerPrint Door Access System. User Manual

Intelligent Security & Fire Ltd

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Remote Relay Module (RRM)

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

Analog Room Pressure Monitor RPC Series

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

DA100 Digital Pyrometer Installation and Operating Instructions

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

Pump-Down Controller MODEL 4052

Auto Dialer. Manual E-921APQ E-921GPQ

MVE TS Controller (Touch Screen)

CT398 Heaterstat TM Temperature Controller. Technical User Guide

Model 4001 Series Single Channel Controller

INSTALLATION AND INSTRUCTION MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

Pioneer-R16 Gas Monitor Operator s Manual

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Q-Logic Digital Controls The Q3 and Qht for Direct Expansion Systems

Long Range Radio Alarm Transmitter

Oakton TEMP 9000 Advanced Thermocouple Controller

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

ISIS USERS MANUAL I.S.I.S. 550B

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

WARNING Important Safety Information

NS (A) ECN

P1195 DUAL TOURNIQUET MONITOR

Transcription:

INSTRUCTION MANUAL ENGINE MONITOR VOTT MODEL: 023-4400-0 3 YEAR WARRANTY INTRODUCTION The VOTT meter is an ideal engine monitor, which displays data via the J1939 CAN Bus. The meter utilizes a large LCD screen to simultaneously display DC volts, oil pressure, temperature and tachometer. It provides accurate digital metering and user programmable alarms. When alarm thresholds are exceeded, the built-in 85 db alarm will sound and the affected display reading will change to RED for the out-of-limit condition. Additionally, a new feature always for user selectable baud-rate, 50k 1000k bits/sec. The meter is waterproof and rugged with a large color LCD display screen. The screen read-out is divided into 4 display sections allowing the operator quick, and accurate assessment of engine conditions. DC volts are displayed from 9.5 33.0 VDC. Oil pressure is displayed from 0 99 PSI. Additionally engine temp and RPM are displayed, 100 250 F and 0000 9999 RPM, respectively. The meter is powered by 12-24 VDC. Four levels of backlighting can be selected for optimal performance. All set-up, calibration and alarm values are saved to non-volatile memory. The system is complete with all necessary mounting hardware. The large LCD display draws only 0.08 amps at full brightness and only 0.02 in sleep mode. The meter comes with a 3 year warranty. File: VOTT_023-4400-0 Rev: B Revised By: PSS/JRN Date: 01-17-2017 1

I. WIRING The VOTT comes with a 33 inch length six conductor cable with a Deutsch Connector #DT04_ 6P attached. The VOTT will operate from 9.5 to 33.0 VDC input. It displays data via J1939 CAN Bus. Meter Deutsch connector pin ID is. Pin Signal Wire Color 1 +9.5-33.0 VDC Red 2 Power/Signal Ground Black 3 J1939+ Yellow 4 J1939 - Green 5 External buzzer 12 White VDC alarm output + 6 External buzzer 12 VDC alarm output - Blue II. MOUNTING The VOTT requires a 2-1/8 diameter round hole for mounting. The meter comes with a aluminum U shaped mounting bracket and #8-32 nuts and lock washers to secure bracket. See Figure 1. (FINGER TIGHTEN ONLY, DO NOT USE TOOLS) Spacing Nut (x2) 2-1/8 (55mm) Hole Clamping Nut (x2) Lock Washer (x2) III. MENU NAVIGATION 1. Main Page When the instrument is powered up it displays the Main page. The Main page displays:,oil PSI, (OR C) and. Values are displayed in GREEN if within acceptable alarm set limits or RED if out of limits condition exists. From MAIN PAGE display: OIL PSI Pressing the p key for ½ second (longer than a quick press but shorter than 2 seconds) will cause a white ALARM bell symbol to be displayed and enable the alarms. Pressing the q key for ½ second (longer than a quick press but shorter than 2 seconds) will disable the alarms and remove the white alarm bell symbol. OIL PSI OIL PSI x Press the + key momentarily while an alarm condition exists will silence the audible and external alarm as indicating by Red X Pressing the + key for ½ second (longer than a quick press but shorter than 2 seconds) will increment the backlight level through four different intensities. Mounting Bracket Bulkhead Gasket - Pre-Installed on Rear of Panel 2

2. Menu Tree: Press * A) Secured Access Pages While in the Main page or Generator Hours page, a Quick press of the * key brings up the Security Access page and a default number 5000 is displayed in the box. II. SET UP: USE DEG C/BARS ( or use DEG F/PSI) RESET MIN/MAX VALUES (see Details page) USE DEG C/BARS RESET MIN/MAX VALUES SET CAN BUS SPEED < - - BACK - SETTING Use the p and q keys to scroll to the correct access code and press ACCEPT to enter that number (default is 1234). The longer you hold down the p or q key, the faster the scrolling of numbers. False entry results in Main Page being displayed. Entry of correct access code unlocks the instrument and brings up the following menu: B) Category: I.ALARMS II.SETUP III.DETAILS IV.ABOUT I. ALARMS Menu: HI LO OIL PRESSURE HI OIL PRESSURE LO ENGINE TEMP. HI HI Alarms Set Up Details Setup Details Alarms Set Up Batt. Volts HI DetailsBatt. Volts LO Oil Pressure HI Setup Oil Pressure LO DetailsEngine TEMP HI Engine RPM HI CHANGE VALUE 116.0 DC VOLTS Alarm Ranges: Engine RPM: 0000-9999 is set to 1300 (whole numbers only) Oil Pressure: Low/High settable to 00-99 (whole numbers only) Engine Temp: High settable to 100-250 Battery Volts: Low/High settable to 9.0-33.0 If no key has been pressed for 60 seconds from any of the menus or submenus, the instrument will revert to displaying the Main Page. The is required to access alarm settings, and instrument setup menus. Set the ACCESS CODE to a number from 0000 to 9999 by using the p and q keys then press the + key to accept. The factory default is set to 1234. For S/W: 2.1 or higher default is set to 4321. If the is ever forgotten, the instrument can be reset back to factory default. Reset to Factory Defaults by pressing and holding the p and q keys while applying DC power. Answer Yes by pressing key labeled Yes. This will reset pasword to 1234. Caution: Resetting to factory default will reset all alarm settings as well. -SET CAN BUS SPEED USE DEG C/BARS RESET MIN/MAX VALUES SET CAN BUS SPEED < - - BACK CHANGE VALUE 10500 BIT RATE KB/S Serial # s starting with the letter B can be adjusted to various Can Bus Bit Rates: 50,125,250,500,1000 K Bits. Units are factory set to 500K. 3

-PRESS ACCEPT The Bit Rate can be changed by accessing the SET UP category and selecting SET CAN BUS SPEED use Up/ Down arrows to set changes in VALUES. III. DETAILS: Displays details page. SN, Min/Max, Alarm Values, etc. IV. ABOUT: Displays splash screen, SW version, HW version and copyright information. SPECIFICATIONS Power Supply: 9.50 to 33.00 VDC, @ 80mA Operating Temperature: 32 to 122 F (0 to 50 C) Size: 4.3 x 4.3 x 3.5 deep (110 x 110 x 89 mm) Display Data: Engine RPM: 0000-9999 ( or as provided by J1939) On screen title Oil Pressure: 0199 PSI (or as provided by J1939). On screen title OIL LSI (factory default).user selectable for Millibars or European standard. On Screen MBRS. Engine Temp:100-250 F ( or as provided by J1939) On screen title (factory default0. User selectable for Centigrade, on screen title ENGINE TEMP C Battery Volts: 9.5-33.0 On screen title. Displays COMM LOSS & red dashes with loss of J1939 DATA. No alarm on COMM LOSS. Accuracy: Battery Volts: As provided by J1939 Engine RPM : As provided by J1939 Engine Temperature: As provided by J1939 Oil Pressure: As provided by J1939 Alarms: Engine RPM, Low/High Oil Pressure, High Engine Temp. and Low/High Battery Volts Alarm Output: 12 VDC, 50 ma max. Kussmaul Electronics VOTT ENGINE MONITOR S/W= 20 H/W= XX COPR. 2011,2016 Cruzpro LTD. Back Back Back Quit Additional Information: Low Oil Pressure only updated if Rpm>100 (ie: engine running) Battery Voltage limited to 99.9 (only 3 digits for display) Oil Pressure limited to 99 PSI (only 2 digits for display) Engine Temperature 32 deg F (0 deg C) minimum (avoid negative numbers when in Deg C) MaxRpm only updated if Rpm > MaxRpm+10 (help prevent exceeding max number of Flash writes) LOST COMM message displayed if no J1939 data received for 10 or more seconds. Restore display on valid data or any key A press of any button activates/restarts 5 minute alarm silence timer Don t allow INSTRUMENT hours to increment in Sleep mode 4

INSTALLATION RECORD DATE INSTALLED INSTALLED BY VEHICLE IDENTIFICATION VEHICLE OWNER WARRANTY POLICY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and/or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. 5