p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

Similar documents
NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Why Thermostats Matter

Technical Progress Report September 15,1996 to November 14,1996

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

2. HEAT EXCHANGERS MESA

Electronic Refrigerant Leak Detector DE-FG36-98G Micronic, Inc. Elie Talamas, Jr. Period: 10/1/99 to 12/31/99

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

ENSC 388: Engineering Thermodynamics and Heat Transfer

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Food Service Technology Center

Falling Film Heat Exchangers for Solar Water Heaters

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

STER 1981 ANNUAL INDUSTRIAL SUMMARY OF FIRE AND PROPERTY DAMAGE EXPERIENCE. Monsanto. MOUND FACILITY Miemisburg. Ohio MLM.ML

Southern California Gas Company Customer Programs Department

PROCEEDINGS SOLAR 95

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

A SIMPLIFIED MODEL FOR SIZING AND CHARACTERIZING A NATURAL CONVECTION HEAT EXCHANGER SYSTEM

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

AVIATION TECHNOLOGY SERVICES: PIPELINE LEAK DETECTION

Compression of Fins pipe and simple Heat pipe Using CFD

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

In the name of God. Jami Institute of Jami - Mehdi Rasti

Los Alamos NATIONAL LABORATORY. A Review of Acceptance Testing of t h e. Continuous Air Monitor (CAM)

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Detection of Inherent and Laser-Induced Scatter in Optical Materials

Substation Monitoring System

NUMERICAL AND EXPERIMENTAL ANALYSIS OF A DEMAND-SIDE HEAT EXCHANGER FOR DOMESTIC HOT WATER HEATING

PERFORMANCE OF WATER FILLED THERMOSYPHONS BETWEEN OC

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Jülich Solar Power Tower System Behavior During Downtime

Food Service Technology Center

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Characterization of Acoustic Burst in Household Refrigerators

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

A Review of Hydronic Balancing of Cooling Water Circuit

/,6 REMOTE MONITORING DESIGN CONCEPTS FOR SPENT FUEL STORAGE FACILITIES

Application of Air Source Variable Refrigerant Flow in Cold Climates

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Condensate Induced Water Hammer in a Steam Distribution System Results in Fatality

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Sunglo Heater Model A270 Patio Heater Performance Test

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

J. S. Baker J. A. Smith

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

PROCEEDINGS SOLAR 95

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

PASSIVE CONTAINMENT COOLING: MODEL EXPERIMENTS

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

COMPATIBILITY OF REFRIGERANTS AND LUBRICANTS WITH MOTOR MATERIALS UNDER RETROFIT CONDITIONS. Final Report

Heat Transfer Enhancement in Shell and Tube Condenser

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Complete Stress Analysis of Sucker- Rod Pumping Installations

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Rod String Design Software Simulation of Sandia Downhole Load Cell Wells

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Heat Transfer in Evacuated Tubular Solar Collectors

86BSD Digital Output

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

System Design & Diagnostic Analysis of Group 2 Systems

HIH-4000 Series Humidity Sensors

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center

Steel Sucker Rod Fatigue Testing Update on Phase I

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

Chapter 5 Heat-transfer Equipment

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

86BSD Digital Output

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Electric radiator tests

ASHRAE JOURNAL ON REHEAT

Modified Everitt-Jennings (MEJ) Method and the Gibbs Method: Downhole Card Comparison

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

NFPA 25 and the Influence of Liability

Transcription:

NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS Technical Progress Report February 1,1996 to March 31,1996 Jane H Davidson Department of Mechanical Engineering University of Minnesota Minneapolis, MN 55455 Prepared for the United States Dep Under Contract No DE-FG36-9 1 w p?:uam

This report was prepared as an account of work sponsored by an agency of the United States Government Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights Reference herein to any specific commercial product, process, or senice by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, mornmendhtion, or favoring by the United States Government or any agency thereof The views and opinions of authors expressed herein do not necessarily state or reflect thosc of the United States Government or any agency thereof

DISCLAIMER Portions of this document may be illegible electronic image products Images are produced from the best availabie original document

NATlJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS DE-FG36-94GO13 Jane H Davidson University of Minnesota Reporting Period: February 1,1996 to March 31,1996 Project Personnel: Jane H Davidson Scott Dahl, Graduate Research Assistant Project Objectives: The goals of this project are 1) to develop guidelines for the design and use of thermosyphon heat exchangers external to the storage tank in solar domestic water heating systems and 2) to establish appropriate modeling and testing criteria for evaluating the performance of systems using this type of heat exchanger ExDerinnental Work We have completed testing of a four tube-in-shell thermosyphon heat exchanger manufactured by AAA Solar Service and Supply Inc, SEMCO, of Albuquerque and given to us by Richard Lane of Public Energy Systems located in Green Bay, Wisconsin A sketch of the Quad-Rod heat exchanger is shown in Fig 1 Cool water from the bottom of the tank enters the shell side of the heat exchanger near the bottom and exits near the top Hot anti-freeze fluid from the collector enters the exchanger through a manifold at the top, flows through the four tubes and returns to the collector through another manifold The double walled tubes are constructed of 1/2 inch copper ACR tubing inside a 1/2 inch Nom copper water tube A small gap between the two tubes allows for leak detection The inside of the tubes is fit with a helical wire However, since the Reynolds number is calculated to have a value less than 23 at a collector flow rate of 3 kg/s with the 5/5 mixture of ethylene glycol and water at a temperature of 9 OC, flow is expected to remain laminar and the wire is not expected to have much effect on heat transfer Nominal exterior heat transfer area is 228 m2 The heat exchanger was tested using the same protocol we used to evaluate the two-pass and single tube-in-shell heat exchangers made by Heliodyne The test consisted of two parts During the first part of the test, the storage tank temperature was maintained at a uniform temperature of 25 degc while the temperature of the collector fluid was increased every 3 minutes in increments of 1 degc from 3 degc to 95 degc The tank was held isothermal by the slow addition of cold mains water to the bottom of the tank as warm water from the top of the tank was dumped The second part of the test began after 2 minutes when the collector fluid was 95 degc At this point in the test, the cold mains water was disconnected from the tank and the tank was allowed to heat up Collector outlet temperature, Th,i, was held constant Two collector flow rates were used: 15 kg/s and 3 kg/s 2

Measured values include collector-side forced flow rate, temperature differences across the heat exchanger, vertical temperature distribution in the storage tank, vertical water temperature profile in the heat exchanger, and pressure drop on the thennosyphon side of the heat exchanger Thermosyphon mass flow rate was determined from an energy balance across the heat exchanger Pressure drop on the thermosyphon side of the heat exchanger was measured and is plotted as a function of flow rate in Fig 2 Unfortunately, our pressure transducer had an electronic problem that caused drift in the zero pressure offset This problem would cause a random vertical shift in data of Fig 2 Although we calibrated the transducerjust prior to obtaining these measurements, we are not positive that they are completely accurate and plan to repeat them once the pressure transducer has been repaired Tempecatures at the inlets and outlets of the heat exchanger are plotted over the duration of the tests in Figs 3 and 4 During the test with a collector flow rate of 15 kg/s, cold water was accidentally introduced into the storage tank for a short period at the beginning of the second part of the test procedure (time = 2 minutes) This event caused the water at the bottom of the storage *tank(thus TcJ) to decrease As a result, he driving force in the loop increased slightly as the hydrostatic pressure difference between the water in storage tank and the heat exchanger increased The increased driving force created a small upward shift in the thermosyphon mass flow rate plotted in Fig 5 The axial temperature distributions in the water on thennosyphon side of the heat exchanger are presented at various times during the test in Fig 6 These measurements were made with 5 mm diameter thermocouple probes inserted inside the shell Temperatures measured on the outer surface of the shell were approximately 1 "C less than temperatures measured in the fluid The measurement uncertainty for the temperature difference is 71 O C which nearly accounts for the difference The temperature profde in this heat exchanger design is nearly linear Previous temperature measurements obtained from surface mounted thermocouples for the two-pass, tubein-shell heat exchanger (Heliodyne) indicated the temperature profile was nonlinear The reason for the difference in the shape of the temperature profdes is the difference in geometry Measured values of UA are plotted as a function of time in Fig 7 The measured value of UA is determined from, During the fust part of the test, UA values obtained with a collector flow rate of 3 kg/s are approximately 15% larger than those measured with a 15 kg/s collector flow rate During the second part of the test, the measured UA values are nearly identical The cold water surge that accidentally occurred in the test with collector flow rate equal to 15 kg/s resulted in a higher temperature difference between Th,i and Tc,i The increased influence of natural convection appears to compensate for the difference in the collector flow rates in the second part of the test Figure 8 presents a plot of measured UA as a function of the thermosyphon flow rate for the two collector flow rates This plot confirms what we found during testing of the Heliodyne heat exchangers Models which assume UA depends solely on thermosyphon flow rate (ie forced flow) do not adequately characterize thermosyphon heat exchangers Heat transfer is in the mixed convection regime During the first 2 minutes of testing, when thermosyphon flow rate increased due to a decrease in water density in the heat exchanger (with no change in the isothermal tank), UA increased as temperature differences across the heat exchanger increased After 2 minutes, the glycol temperature was held constant and the tank was allowed to heat up 3

As a result of a decrease in the pressure in the water tank,thermosyphon flow rate decreased but with no appreciable change in UA Under these operating conditions, heat transfer coefficients did not change significantly because both the temperature difference controlling natural convection and Re of the glycol flow remained nearly constant A better method of predicting UA from the Prandtl, Reynolds and Grashof numbers is shown in Fig 9 Thedata for both collector flow rats have been combined in attempts to obtain a single correlation for UA which is not dependent on the collector flow rate A linear regression technique was used assuming The parameters P1 through P4 were solved using linear regression The dimensionless parameters are based on fluid properties calculated for a temperature equal to the average of the hot and cold inlet temperatures, The Grashof number is also based on the temperature difference between TSi and TGi We are currently investigating methods of incorporating similar models into a shnpwied testing and modeling procedure The paper Issues of Predicting Performance of Thennosyphon Heat Exchangers in Solar Water Heaters was presented at the 1995 ASME International Solar Energy Conference in San Antonio, April 1, 1996 The paper won the best paper award given by the Fundamentals Technical Committee of The ASME Solar Energy Division Future Activity Continued fundamental analysis of the thennosyphon heat exchanger is underway and modeling efforts hiave begun 4

13319 1,- Fig 1 Schematic of the SEMCO "Quad-Rod" multiple-tube-in-shellheat exchanger 2 3! 'D 15t 1 5 I z rne3 kg/s 1 1 5 Thermosyphon Mass Flow Rate, kg/s 5 Fig 2 Pressure drop on the thermosyphon side of the heat exchanger 5 2

loo 9 8 v 7 3 6o 5 f E a c 4 3 2 1 2 4 6 8 Time, minutes 1 12 Fig 3 Measured temperatures at the inlet and outlets of the Quad-Rod tube-in-shell heat exchanger plotted versus test duration Collector flow rate is 15 kg/s 1 3 2 r f * *-- 2 4 6 8 Time, minutes r 1 12 Fig 4 Measured temperatures at the inlet and outlets of the Quad-Rod tube-in-shell heat exchanger plotted versus test duration Collector flow rate is 3 kg/s 6

18 16 sx 14 d g 12 U 3 1 L 5 8 c P @ 6 g 4 e 2 1 12' mc = 3 kg/s/ 1 mc = 15 kg/s] e 1: i 2 4 6 8 Time, minutes 1 12 Fig 5 Thermosyphon flow rate plotted versus test duration for collector flow rates of 15 kg/s and 3 kg/s 9 8 ve C 7 6 ' E 5 4 3 2 2 4 6 Heat exchanger position, XR 8 1 Fig 6 Axial temperatwe distribution on the thermosyphon side of the heat exchanger 7

2 4 6 Time, minutes 8 1 12 Fig 7 Measured values of UA plotted versus test duration for collector flow rates of 15 kg/s and 3 kg/s 5 45 4 $* 8 15 lo 5 I og 8 t 1 15 Themosyphon Flow Rate, kg/s 5 Fig 8 Measured UA plotted as a function of thermosyphon flow rate 8 2

-- 5 I 45 y = 9883~ R2= 9171 4 + Measurement Uncertslnty l 5o / 1 2 3 4 288Pr+O8)Reh(-21)Gr*( 26) 5 6 Fig9 Measured UA expressed as a function of Gr, Pr,and Re numbers for both collector flow rates, (15and 3 kg/s) 9