Installation Manual Premier Elite IXP-W

Similar documents
Installation Manual. Premier IXP-W INS538

Premier External TD. Installation Manual INS352-3

Installation Manual Premier Elite Orbit QD/DT INS483-2

Installation Manual. Odyssey X Series INS627-2

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Installation Manual Premier LCD/LCDL INS180-4

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

KM300 Carbon Monoxide Detection System Installation Manual

KFP-CF Series Operation Manual

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

IR Speed Dome. Quick Guide UD.6L0201B1357A01

PQS performance specification

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Record of Amendments. Version Date Amendment Section/page affected

Dual-Network LCD Keyboard Intelligent Alarm

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

PQS performance specification

FEC403EN Installation Manual

ZP2 Series Operation Manual

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

Owner & Operator s Manual. Table of Contents

IFS Fiber Module Installation & Operation Instructions

1X-F Series Installation Manual

600 Range Dialer Installation Manual. Version 1.0

PQS performance specification

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

installation & operation manual

Advisor Advanced User Guide

Temporary wireless battery operated fire system from Channel Safety Systems

Operating Instructions

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer

Manual & Technical Documentation V1.1

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

PROCESSING UNIT II V Hz V Hz. Table of Contents

Installation and ZONES: Operation Manual. Model: ON STI-34108

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EWR2 WIRELESS SIGNAL REPEATER

PQS performance specification

Pendant V3.00a Installation Guide

4100U City and Relay Cards Installation Instructions

VS-AXESS-4DLX Installation Manual

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

IFS Fiber Module Installation & Operation

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND

IFS Fiber Module Installation & Operation Instructions

External Wireless Sounder

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

Installation and Operation Manual

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

CET2000B-RF + RX1-S + CS2

IFS SFP Tranceivers User Manual

COMMUNICATOR ET08 / ET081

TX24-10A. Intelligent PSU Installation and Operation Manual. TANDA UK Technology Copyright 2016, All right reserved.

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL


Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

USER GUIDE v1.4. Introduction. This document discusses the use and architecture of the OptiGrid Structured Illumination System.

SDR-WEXT Wired Siren Installation Guide

HULME MARTIN HEAT SEALERS

(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

SWITCHING POWER GENERATOR FOR 0.9 & 1.2 KW MAGNETRON TECHNICAL NOTE

Use & Care Manual Contemporary Electric Fires

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Fortimo LED Line Gen2 Module

Robotic Mowers (battery powered and charging station connected to electric mains or low voltage supply)

NX-181xx NetworX Voice keypad with touch buttons User Manual

Quick Reference Guide: Connectors for Mobile Devices

Product Guide International Edition

Norpak 100LD Label Dispenser

Fortimo LED Line High Flux Module

Wideband Optical Couplers

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

HYTEK ATEX APPROVED BUND ALARM

Panel Remote Annunciators Installation Instructions

ETH1000-MKII. User manual

R-Series Remote Annunciators and Expanders Installation and Operation Guide

EWS3 WIRELESS INDOOR SIREN

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

The leading manufacturer of award-winning security products

laundry Laundry dosing systems

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

HEP Tech Co., Ltd. Company Profile

OVC OVC2000. New Family of Electronic Oven Controls

Transcription:

Installation Manual Premier Elite IXP-W INS538-2

1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier Elite 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the IXP-W... 7 Wiring... 8 5. Programming... 9 Option Switch Settings... 9 Configuring Radio devices... 9 Adding Devices to the Receiver... 9 Ricochet Monitor... 9 Engineers Keypad... 9 Premier Elite 8XP-W & 32XP-W Learn Switch... 9 6. Specifications... 10 Electrical... 10 Standards... 11 Warranty... 11 INS538-2 2

2. Premier Elite IXP-W Interface The Premier Elite IXP-W Interface is designed to be used in conjunction with a Premier 8XP- W/32XP-W Wireless Mesh Networking Expander. The IXP-W allows you to use Ricochet enabled sensors and devices on any control panel. For the purposes of illustration the Texecom Veritas is shown in this manual as an example for connection. This manual should be read along with INS467 for the Premier Elite 8XP-W & 32XP-W, and with any device specific installation manuals. Premier Elite 8XP-W & 32XP-W Firmware The IXP-W is only compatible with firmware version 1.3.4 and later of the 8XP-W & 32XP-W. To check the firmware version of your receiver you can use either Ricochet Monitor software, or a Premier Engineers keypad. The firmware version is also printed on a small sticker located on the main processor on the PCB. Please see INS467 Installation Instructions Premier Elite 8XP-W/32XP-W or the Ricochet Monitor Help files. 3 INS538-2

3. Quick Start Guide Firmware for the Premier Elite 32XP-W & 8XP-W must be V1.3.4 or later for the Premier IXP-W to function Connect IXP-W to 8XP-W or 32XP-W 12V 0V T & R Connect 12V & 0V to control panel Aux supply Set Option switch 2 Premier 8XP-W/32XP-W to ON Make Control panel connections for Zones, Global Tamper, Global Poll Error & Global Battery Learn Devices to the Receiver with Engineers Keypad, Ricochet Monitor or onboard LED s See INS467 for more detail Place Devices in desired location, use LED to indicate Signal Security See INS467 for more detail Wait 15 Minutes for Mesh Network to establish Change Device Attributes according to application See INS467 Walk Test System See INS467 INS538-2 4

4. System Overview 1 2 3 4 5 6 14 1 2 3 4 5 6 7 SYSTEM STATUS INPUTS GPE GT GLB +12V 0V T R 7 8 9 10 11 12 Sw1 Sw2 Z4 Z8 Z7 Z6 Z5 Z3 Z2 Z1 13 1: Address Switches Not Used. 2: Option Switches Only Switch 4 is used to enable/disable Walktest Mode, this is the same as on the receiver, please see INS467 for more information. 3: Global Poll Error Connect to a spare Zone on the control panel to signal a polling error from a device. 5 INS538-2

4: Global Tamper Connect to Global Tamper, or a spare circuit on the control panel to indicate Tamper on either a device, the IXP-W or the Receiver. 5: Global Low Battery Connect to a spare zone on the control panel to signal low battery from devices on the system. If not required link out. 6: Flash Programming Port For future use. 7: Heartbeat LED This LED beats once per second. 8: Transmit LED Pulses when data is being transmitted. 9: Receive LED Pulses when data is being received. 10: Network Connection Network connections for connecting the IXP to the receiver. 11: Cover Tamper Tamper Switch connection. 12: Tamper Disable Link out to disable cover tamper. 13: Zone Connections For connecting the IXP-W to the control panel. 14: System Status Connections For Future Use INS538-2 6

ON ON Premier Elite IXP-W Installation Manual Mounting the IXP-W Remove the Screw cover by locating the two small indents on the upper and lower edge with a small screwdriver, excessive force is not required. Remove the retaining screw 1 2 3 4 1 2 3 4 7 INS538-2

Wiring It is strongly recommended that the system is completely powered down (mains and battery) before wiring the expander and interface card. Connect the expander to the interface using 4-core cable, and make all other connections as follows: Expander Interface Panel Description + + Aux + +12V Supply - - Aux - 0V Supply T T N/A Transmit Data R R N/A Receive Data Z1-Z8 GPE GLB GT Panel Zones Panel Zone or Separate* Aux Input Panel Zone or Separate* Aux Input Global Tamper or Separate* Aux Input Radio Devices N/C Input Global Poll Error N/C Input Global Low Battery N/C Input Global Tamper for devices, Expander & Interface To ensure correct operation, all four terminals on the interface must be connected to the corresponding terminals on the expander. If Global Poll or Global Low battery are not required, link out the connections on the IXP-W. *Do not wire all of these to the same input! Standard 7/0.2 alarm cable can be used for most installations. However, under certain conditions it may be necessary to use screened cable. INS538-2 8

5. Programming Option Switch Settings All switches on the IXP-W should be turned OFF. Option switch 2 on the Premier 8XP-W/32XP-W should be turned ON. Configuring Radio devices Up to 8 wireless devices of any combination can be learnt to the system. When learning devices the receiver needs to be in commission mode, please see INS467 for details. Adding Devices to the Receiver Devices can be learned onto the system in three ways. It is highly recommended that Ricochet Monitor is used to add/delete devices and to monitor system status and the Signal Security of the mesh network. Ricochet Monitor To use Ricochet Monitor follow the instructions detailed in the Information files of the programme for Adding & Deleting Devices. Engineers Keypad To use an Engineers Keypad follow the instructions in INS467 the Installation Manual for the Premier 8XP-W & 32XP-W. Premier Elite 8XP-W & 32XP-W Learn Switch It is possible to learn devices directly to the receiver using the learn switch on the receiver, to use this option please follow the instructions in INS467 the Installation Manual for the Premier 8XP-W & 32XP-W. 9 INS538-2

6. Specifications Electrical Operating Voltage Current Consumption 10-13.7VDC <20mA Network 4-wire standard 7/0.2 alarm cable up to 250m. Inputs 1-8 N/C Weight Boxed 176g unboxed 151g Dimensions Operating Temperature Storage Temperature Maximum Humidity EMC Environment L147mm x W92mm x H32mm -10 C (+14 F) to +50 C (+122 F) -20 C (-4 F) to +60 C (+140 F) 95% non-condensing Residential, Commercial, Light Industrial or Industrial INS538-2 10

Standards 2004/108/EC (CE directive): Hereby, Texecom declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. Weee Directive: 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex. This product is a Type B Moveable device and is suitable for use in systems designed to comply with EN 50131-1, EN50131-3, EN50131-5-3 and PD6662 at Grade 2 and Environmental Class II. Warranty All Texecom products are designed for reliable, trouble-free operation. Quality is carefully monitored by extensive computerised testing. As a result the Premier IXP-W expander is covered by a two-year warranty against defects in material or workmanship. As the Premier Elite IXP-W interface is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier Elite IXP-W interface failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice. Premier Elite is a trademark of Texecom Ltd. Prestige is a trademark of Texecom Ltd. SmartKey is a trademark of Texecom Ltd. Ricochet is a trademark of Texecom Ltd. SignalSecurity is a trademark of Texecom Ltd. TEXECOM LTD 2012 11 INS538-2

Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1706 233875 Email: techsupport@texe.com Texecom Limited 2011 INS538-2