Installation Manual. Premier IXP-W INS538

Similar documents
Installation Manual Premier Elite IXP-W

Premier External TD. Installation Manual INS352-3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Installation Manual Premier Elite Orbit QD/DT INS483-2

Installation Manual. Odyssey X Series INS627-2

Installation Manual Premier LCD/LCDL INS180-4

KM300 Carbon Monoxide Detection System Installation Manual

IR Speed Dome. Quick Guide UD.6L0201B1357A01

KFP-CF Series Operation Manual

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

PQS performance specification

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

PQS performance specification

600 Range Dialer Installation Manual. Version 1.0

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Temporary wireless battery operated fire system from Channel Safety Systems

Installation and Operation Manual

FEC403EN Installation Manual

installation & operation manual

Owner & Operator s Manual. Table of Contents

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND

Pendant V3.00a Installation Guide

VS-AXESS-4DLX Installation Manual

Dual-Network LCD Keyboard Intelligent Alarm

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

1X-F Series Installation Manual

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

IFS Fiber Module Installation & Operation Instructions

Installation and ZONES: Operation Manual. Model: ON STI-34108

IFS Fiber Module Installation & Operation Instructions

Record of Amendments. Version Date Amendment Section/page affected

IFS Fiber Module Installation & Operation Instructions

Operating Instructions

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

PQS performance specification

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Advisor Advanced User Guide

PROCESSING UNIT II V Hz V Hz. Table of Contents

4100U City and Relay Cards Installation Instructions

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F


PQS performance specification

EWR2 WIRELESS SIGNAL REPEATER

SDR-WEXT Wired Siren Installation Guide

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Polycarbonate External Sounder & Strobe Unit

Use & Care Manual Contemporary Electric Fires

ZP2 Series Operation Manual

Manual & Technical Documentation V1.1

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

TX24-10A. Intelligent PSU Installation and Operation Manual. TANDA UK Technology Copyright 2016, All right reserved.

CET2000B-RF + RX1-S + CS2

Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer

IFS Fiber Module Installation & Operation

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

IFS Fiber Module Installation & Operation Instructions

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Wideband Optical Couplers

Fortimo LED Line Gen2 Module

DET-RWATER Flood Detector Installation Guide

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

43PFL6572/V7 39PFL6572/V7 32PFL6572/V7

Door Monitor V3.00a Installation Guide

Use & Care Manual Inset Electric Fires

Panel Remote Annunciators Installation Instructions

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

R-Series Remote Annunciators and Expanders Installation and Operation Guide

HYTEK ATEX APPROVED BUND ALARM

USER GUIDE v1.4. Introduction. This document discusses the use and architecture of the OptiGrid Structured Illumination System.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.


HULME MARTIN HEAT SEALERS

Flair 500 Series Annunciators

HEP Tech Co., Ltd. Company Profile

NX-181xx NetworX Voice keypad with touch buttons User Manual

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

X64 Wireless Training

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Installation Manual RINS1211-4

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

OVC OVC2000. New Family of Electronic Oven Controls

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Transcription:

Installation Manual Premier IXP-W INS538

1. Contents 1. Contents... 2 2. Premier IXP-W Interface... 3 Premier 8XP-W & 32XP-W Firmware... 3 3. Quick Start Guide... 4 4. System Overview... 5 Mounting the IXP-W... 7 Wiring... 8 5. Programming... 9 Option Switch Settings... 9 Configuring Radio devices... 9 Adding Devices to the Receiver... 9 Ricochet Monitor... 9 Engineers Keypad... 9 Premier 8XP-W & 32XP-W Learn Switch... 9 6. Specifications... 10 Electrical... 10 Standards... 11 Warranty... 11 INS538 2

2. Premier IXP-W Interface The Premier IXP-W Interface is designed to be used in conjunction with a Premier 8XP-W/32XP-W Wireless Mesh Networking Expander. The IXP-W allows you to use Ricochet enabled sensors and devices on any control panel. For the purposes of illustration the Texecom Veritas is shown in this manual as an example for connection. This manual should be read along with INS467 for the Premier 8XP-W & 32XP-W, and with any device specific installation manuals. Premier 8XP-W & 32XP-W Firmware The Premier IXP-W is only compatible with firmware version 1.3.4 and later of the Premier 8XP-W & 32XP-W. To check the firmware version of your receiver you can use either Ricochet Monitor software, or a Premier Engineers keypad. The firmware version is also printed on a small sticker located on the main processor on the PCB. Please see INS467 Installation Instructions Premier 8XP-W/32XP-W or the Ricochet Monitor Help files. 3 INS538

3. Quick Start Guide Firmware for the Premier 32XP-W & 8XP-W must be V1.3.4 or later for the Premier IXP-W to function Connect IXP-W to 8XP-W or 32XP-W 12V 0V T & R Connect 12V & 0V to control panel Aux supply Set Option switch 2 Premier 8XP-W/32XP-W to ON Make Control panel connections for Zones, Global Tamper, Global Poll Error & Global Battery Learn Devices to the Receiver with Engineers Keypad, Ricochet Monitor or onboard LED s See INS467 for more detail Place Devices in desired location, use LED to indicate Signal Security See INS467 for more detail Wait 15 Minutes for Mesh Network to establish Change Device Attributes according to application See INS467 Walk Test System See INS467 INS538 4

4. System Overview 1 2 3 4 5 6 14 1 2 3 4 5 6 7 SYSTEM STATUS INPUTS GPE GT GLB +12V 0V T R 7 8 9 10 11 12 Sw1 Sw2 Z4 Z8 Z7 Z6 Z5 Z3 Z2 Z1 13 1: Address Switches Not Used. 2: Option Switches Only Switch 4 is used to enable/disable Walktest Mode, this is the same as on the receiver, please see INS467 for more information. 3: Global Poll Error Connect to a spare Zone on the control panel to signal a polling error from a device. 5 INS538

4: Global Tamper Connect to Global Tamper, or a spare circuit on the control panel to indicate Tamper on either a device, the IXP-W or the Receiver. 5: Global Low Battery Connect to a spare zone on the control panel to signal low battery from devices on the system. If not required link out. 6: Flash Programming Port For future use. 7: Heartbeat LED This LED beats once per second. 8: Transmit LED Pulses when data is being transmitted. 9: Receive LED Pulses when data is being received. 10: Network Connection Network connections for connecting the IXP to the receiver. 11: Cover Tamper Tamper Switch connection. 12: Tamper Disable Link out to disable cover tamper. 13: Zone Connections For connecting the IXP-W to the control panel. 14: System Status Connections For Future Use INS538 6

ON ON Premier IXP-W Installation Manual Mounting the IXP-W Remove the Screw cover by locating the two small indents on the upper and lower edge with a small screwdriver, excessive force is not required. Remove the retaining screw 1 2 3 4 1 2 3 4 7 INS538

Wiring It is strongly recommended that the system is completely powered down (mains and battery) before wiring the expander and interface card. Connect the expander to the interface using 4-core cable, and make all other connections as follows: Expander Interface Panel Description + + Aux + +12V Supply - - Aux - 0V Supply T T N/A Transmit Data R R N/A Receive Data Z1-Z8 GPE GLB GT Panel Zones Panel Zone or Separate* Aux Input Panel Zone or Separate* Aux Input Global Tamper or Separate* Aux Input Radio Devices N/C Input Global Poll Error N/C Input Global Low Battery N/C Input Global Tamper for devices, Expander & Interface To ensure correct operation, all four terminals on the interface must be connected to the corresponding terminals on the expander. If Global Poll or Global Low battery are not required, link out the connections on the IXP-W. *Do not wire all of these to the same input! Standard 7/0.2 alarm cable can be used for most installations. However, under certain conditions it may be necessary to use screened cable. INS538 8

5. Programming Option Switch Settings All switches on the IXP-W should be turned OFF. Option switch 2 on the Premier 8XP-W/32XP-W should be turned ON. Configuring Radio devices Up to 8 wireless devices of any combination can be learnt to the system. When learning devices the receiver needs to be in commission mode, please see INS467 for details. Adding Devices to the Receiver Devices can be learned onto the system in three ways. It is highly recommended that Ricochet Monitor is used to add/delete devices and to monitor system status and the Signal Security of the mesh network. Ricochet Monitor To use Ricochet Monitor follow the instructions detailed in the Information files of the programme for Adding & Deleting Devices. Engineers Keypad To use an Engineers Keypad follow the instructions in INS467 the Installation Manual for the Premier 8XP-W & 32XP-W. Premier 8XP-W & 32XP-W Learn Switch It is possible to learn devices directly to the receiver using the learn switch on the receiver, to use this option please follow the instructions in INS467 the Installation Manual for the Premier 8XP-W & 32XP-W. 9 INS538

6. Specifications Electrical Operating Voltage Current Consumption 10-13.7VDC <20mA Network 4-wire standard 7/0.2 alarm cable up to 250m. Inputs 1-8 N/C Weight Boxed 176g unboxed 151g Dimensions Operating Temperature Storage Temperature Maximum Humidity EMC Environment L147mm x W92mm x H32mm -10 C (+14 F) to +50 C (+122 F) -20 C (-4 F) to +60 C (+140 F) 95% non-condensing Residential, Commercial, Light Industrial or Industrial INS538 10

Standards The Premier IXP conforms to European Union (EU) Low Voltage Directive (LVD) 2006/95/EC. Electro- Magnetic Compatibility (EMC) Directive (2004/108/EC. RoHS Directive 2002/95/EC this device does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage described in the EU Directives, except exceptions described in the EU Directive. WEEE Directive (2002/96/EC) Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points. For more information see www.recyclethis.info EN50131-1 Alarm systems. Intrusion & hold up alarm systems. System requirements. Grade 2 Class II EN50131-3 PD6662 Alarm systems. Intrusion & hold up alarm systems. Control and indicating equipment. Grade 2 Class II Scheme for the application of European standards for intrusion and hold up alarm systems. Grade 2 Class II Warranty All Texecom products are designed for reliable, trouble-free operation. Quality is carefully monitored by extensive computerised testing. As a result the Premier IXP-W expander is covered by a two-year warranty against defects in material or workmanship. As the Premier IXP-W interface is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Premier IXP-W interface failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice. Premier is a trademark of Texecom Ltd. Prestige is a trademark of Texecom Ltd. SmartKey is a trademark of Texecom Ltd. Ricochet is a trademark of Texecom Ltd. SignalSecurity is a trademark of Texecom Ltd. TEXECOM LTD 2011 11 INS538

Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at local rate from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 686197 Email: techsupport@texe.com Texecom Limited 2011 INS538