Yale Locks. Z-Wave+ System Integrators Guide. Yale nextouch Sectional Mortise Keypad Lock NTM 610/615/620/625/630/635/640/645

Similar documents
Yale Locks. ZWave Developer User and Reference Guide. Version /30/2012

Z-Wave Network Inclusion/Exclusion/Reset

Instruction Manual Water Sensor

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Instruction Manual Siren Alarm

SHARP. Multi Sensor User s Guide. Model: DN3G6JA069

Devolo home Control Door/Window Contact MT 02648

Stand-alone Touchscreen Access Lock. An ASSA ABLOY Group brand

IX30 - Z-Wave PIR Detector User Guide

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Slim Multisensor PST02-A/B/C

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

Slim Multisensor PST02-A/B/C

Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT)

POP_ Smoke Detector

POP_ Smoke Detector

ZTS-500US Z-Wave Smart Thermostat

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

KEYLESS WIRELESS DIGITAL DEADBOLT

IM20-ZWAVE Magnetic Contact User Guide

ZTS-500US Z-Wave Smart Thermostat

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

10 Year Smoke Detector and Siren

Smoke Detector and Siren. Manual

Quick start: Alarm Sound EU

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

PIR sensor GR-302N GR SMART HOME

ANSI/BHMA Grade 1 Certified Keypad Access Lock. An ASSA ABLOY Group brand

Nest x Yale Lock Programming/Troubleshooting Guide

PET IMMUNE PIR MOTION DETECTOR

AXI LED USER MANUAL (REV. 1.0)

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Instruction Manual Contact Sensor

SRT321 User and Installation Instructions

Dimmer Switch MH-DT411

Paradox Integration Module Settings Guide

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

CD30 Codoor. Instruction Manual

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

Table of Contents. Appendix A Special Characters 31

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

FIB_FGBS-001 Universal Binary Sensor

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

ELT-KLED EliteSuite LED Keypad Installation Manual

Certification Exhibit FCC ID: U4A-YRHZPZW0 IC: 6982A-YRHZPZW0. FCC Rule Part: IC Radio Standards Specification: RSS-210

shine TM Manual User guide and installation instructions The global leader in door opening solutions

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

CONTACT ID REPORT CODES

Version 1.03 January-2002 USER S MANUAL

Series. NX-4-EUR Control Panel. Installation manual

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

SPLIT-DECODED CONTROLLER

Motion Sensor MOSZB-130. Technical manual

Door/Window Sensor Installation Instructions

SERVICE & SETUP MANUAL WATER HEATER ELECTRONIC CONTROLLER

RS485 MODBUS Module 8AI

RC-122BZ Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool Thermostat Installation Instructions

BURGLAR ALARM PANEL BS-468

FCD-wire Contents. List of Figures

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

CBI-064. User Manual. Caddx to KNX-BUS Interface

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

2000 Series. Program Entry Guide. Control Panels

SmarTemp Control fx 2.0

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

RE6100 Series Helix Security and Automation Platform

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Symmetra MW Modbus Data Points

Intelligent Security & Fire Ltd. PX Control Panel. User Manual. Issue C

User manual. KNXgal. version

Contents. Glossary

Security System. User s Guide for the Text Command Center

Solution 880 Operators Manual. Issue 1.00

SCS311 / SCS317 Installation Instructions

Security System. User Guide for the LED Command Center

CC408. Quick Reference Guide Solution 880

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

4" Touchscreen Shown - 5.5" Available

Quick Programmer s Manual

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

YALE LOCKSETS. Yale Locksets offer protection and convenience for your business, home and your family.

1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000)

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

DOLKPS1KB Programming & Installation Manual

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

Operating Instructions Transponder code lock - Part 2 (split decoder)

Yale Assure Lock Touchscreen Deadbolt Installation and Programming Instructions ( YRD226/YRD426)

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

AXS Strikemaster Engineering Manual

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Transcription:

Yale Locks Z-Wave+ System Integrators Guide Yale nextouch Sectional Mortise Keypad Lock NTM 610/615/620/625/630/635/640/645 1

Contents Yale Z-Wave+ Info... 3 Supported Command Classes... 3 Association Table... 4 Notifications Table... 4 Configurable Parameters... 7 2

Yale Z-Wave+ Info Manufacturer ID: Assa Abloy (0x0129) Z-Wave Device Type: Door Lock Keypad Z-Wave Role Type: Listening Sleeping Slave (LSS) Product ID: 0x0A00 Product Type ID: 0x8008 NTM620/625/640/645-ZW2 (Touch Screen interface) 0x8008 NTM610/615/630/635-ZW2 (Push Button Interface) Supported Command Classes Command Class Z-Wave+ Info Command Class Manufacturer Specific Command Class Security Command Class Device Reset Locally Command Class Power Level Command Class Version Command Class Battery* Command Class Door Lock* Command Class Door Lock Logging* Command Class Schedule Entry Lock* Command Class User Code* Command Class Time Parameters* Command Class Time* Command Class Association* Command Class Association Group Info* Command Class Notification* Command Class Configuration* Command Class Firmware Update Md* * Command Class Requires Security 3

Association Table Group ID Maximum Nodes Description Commands 1 5 Lifeline Command_Class_Battery, Battery_Report ; Command_Class_Notification, Notification_Report; Command_Class_Configuration, Configuration_Report; Command_Class_Device_reset_locally, Device_Reset_locally_notification Notifications Table: Alarm Reports Alarm type Alarm Level Description Notification Type Event Master code was 0x00 Master Code changed at keypad 0x12 changed. Master code was 0xFB 0x70 changed over RF 0x0E User added User added. Alarm level = user slot 0X0E User deleted 0x21 User was deleted. Alarm level = user slot 0X0D(0X0C) keypad attempts 0x01 exceed code entry 0X10 Tamper Alarm 0xA1 limit 0x02 front escutcheon removed from main RF Operate Unlock 0x19 0x01 by RF module 0X04 Where Alarm level Keypad Unlock 0x13 Master Code) represents user slot (0xFB = 0X06 0x01 by key cylinder or inside thumb-turn 0x01 Manual Lock 0x15 by touch function 0x02 (lock and leave) 0x01 0x03 By inside button 0x01 4

RF Operate Lock 0x18 0x01 by RF module 0x03 Where Alarm level 0x (01 max Keypad Lock 0x12 represents user slot 0x05 Non Access Low Battery Alarms** Auto Lock Operate Locked Duplicate Pin-code error RF Module Power Cycled Disabled user entered at keypad Valid user but outside of schedule 0x26 0xA8 0x (Current %) 0xA7 0x (Current %) 0x1B 0x71 0x82 0x83 0x84 0x01 0x (01-max 0x00 A Non Access Code was entered at the lock. Where alarm level represents user slot Critical Battery Level (Starting at 4.6V) Low Battery (Starting at 4.4V) Auto re-lock cycle complete, locked. Where Alarm level represents user slot Alarm generated in response to add user RF cmd. This alarm is not generated when attempting to add duplicate pin at the keypad. The lock simply denies it and plays the Denied. Trying to duplicate the master code will result in a 0x71 0x00 alarm report. Power to RFM was restored, sent by RF module. The lock doesn t send any alarm to the RF module when power is cycled. A disabled user pin code was entered at the keypad A valid user can be both a normal user and a Non-Access user. If a non-access 5 0x08 0x08 0x08 0x0B 0x0A 0x09 0x0F 0x01

Door Position Sensor Daily Repeating Schedule Set/Erased Daily Repeating Schedule Enabled/Disabled Year Day Schedule Set/Erased Year Day Schedule Enabled/Disabled All Schedule Types Erased All Schedule Types Enabled/Disabled 0x2B 0x60 0x61 0x62 0x63 0x64 0x65 user is out of schedule this alarm will be sent instead of the nonaccess alarm. 0x00 Door Opened 0x16 0x01 Door Closed 0x17 0x02 Door Propped (Door Open for longer than configurable door propped time) set/erased for enabled/disabled for set/erased for enabled/disabled for set/erased for enable/disabled for Deadbolt 0x0000 Deadbolt Secure 0XFE Secured/Unsecured 0x2A 0x0001 Deadbolt Extended/Secured Lever Rotated (Rx) 0x29 0x0000 Lever was rotated. WGA10 does not distinguish between inside/outside levers ** - The Yale lock also supports a 3 rd low battery alarm, too low to operate. This alarm is sent out as a Battery Report (with value = 0xFF) through the Battery Command Class. This is the last low battery alarm level before the product stops functioning. 6

Configurable Parameters Configuration Parameters Parameter Number Size Description Silent mode on/off 1 1 byte Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 1 or High Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 1 to 180 seconds default is 03 seconds Wrong Code Entry Limit 4 1 byte 3 to 10 default is 5 times Language 5 1 byte 1=English, 2=Spanish, 3=French default is 1= English Shut down time (after wrong code entries) 7 1 byte 10 to 180 seconds default is 60 seconds operating mode 8 1 byte 00 = normal mode (this is the default mode) 01 = vacation mode, keypad lockout 02 = privacy mode, no keypad. RF Unlock will work 03 = passage mode, Lock is permanently unlocked. One Touch Locking 11 1 byte 0x00 = OFF, 0xFF = ON default is 0xFF or ON. Privacy Button 12 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Lock Status LED 13 1 byte 0x00 = OFF, 0xFF = ON default is 0xFF or ON. Reset To Factory Defaults 15 1 byte 01 = Lock will execute Reset To Factory. No default value 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Escape Return Mode 16 1 byte Door Propped Timer 18 1 byte Enables the Escape Return mode of operation for the lock. 10 to 2540 second. This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm. Default = 0x00 (OFF) 7

0x00 = OFF, 0xFF = ON Default is 0xFF or ON. DPS Alarms(Ax sensor) 19 1 byte Used to enable/disable door condition alarms for locks that support a door position sensor. Any lock that does not support DPS will always report 0x00. 0x00 = NO deadbolt, 0xFF = YES deadbolt Deadbolt Installed 20 1 byte Read only parameter. Some locks contain optional deadbolt hardware. This parameter is used to determine if one is installed. 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Eco Mode On/Off 21 1 byte If supported switches lock to lower power mode of operation with reduced sound and led brightness. Privacy Mode with Deadbolt 22 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF If enabled then extending the deadbolt will put the lock into Privacy Mode. Each bit controls one alarm. 1 = alarm enabled, 0 = alarm disabled. 0xFF = All Alarms on, Default is 0xFF. Lock Body Alarms Mask 23 1 byte Bit 0: DPS Alarm (AX) (Duplicate of parameter 19. Values should be tied together) Bit 1: Deadbolt Alarm Bit 2: Lever Rotated (Rx) Bit 3 7: Not Used *** - Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock. 8