Suction Line Accumulators

Similar documents
Suction Accumulators. Introduction. Suction Accumulators

Tube-in-tube heat exchanger Type HE

Check valve Types NRV and NRVH

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Tube-in-tube heat exchanger Type HE

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

APOGEE Open Processor with McQuay Microtech Driver: European Reciprocating Chiller (CR1)

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Energy Use in Refrigeration Systems

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

CASE STUDY AIR-CONDITIONERS

COMPANY PROFILE 2016

30GN FLOTRONIC II AIR-COOLED CHILLERS

Compressors, Chillers & Condensers

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Enthalpy Charts

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

APOGEE Open Processor with McQuay Microtech Driver: Series 200 Centrifugal Chiller

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

500 EX Fusion Compressor Series

SUBCRITICAL & TRANSCRITICAL SYSTEMS

OIL SEPARATORS APPLICATIONS

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

HVAC Fundamentals & Refrigeration Cycle

REFRIGERATION DRYER. DSX - DX from 0,6 to 35 m 3 /1

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

NATURAL REFRIGERANT SYSTEMS

General information on refrigerant controllers

Self-Contained & Split System Reverse Cycle Air Conditioners Models

30GT FLOTRONIC AIR-COOLED CHILLERS

Self-Contained & Split System Reverse Cycle Air Conditioners Models

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Refrigerant Recovery/Recharging Series

Technical Information

DAIKIN Modular Inverter Air Cooled Chiller

Thermostatic Expansion Valves Type TR 6

Filter Driers with Replaceable Core

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

PULSE WIDTH MODULATING VALVES

McQuay BACnet Solution: Microtech II Water-Cooled Centrifugal Chiller Controller (WSC, WDC, WPV)

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Call us today! (800)

Call us today! (800)

Bulletin , March Electric Hot Gas Bypass Valves

Energy saving effect of ejector technology

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

MVC V2.0. MVC EEV Controller

Installation Methods for HBX Sensors

AIR COOLED CONDENSING UNITS

SB Series Brazed Plate Heat Exchanger Installation Manual

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

REFRIGERATION PRODUCTS

Industrial Refrigeration Defrost Solutions TM Package. Brochure R-222

TOSHIBA AIR CONDITIONING

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

LG VRF Systems. Air Conditioning Technologies

Call us today! (800)

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

GLIDER_. air cooled liquid chilled chillers / heat pumps

Selection and Operational Considerations. Harold Streicher, Vice President Sales Hansen Technologies, Inc.

Accumulators - Suction Line

Microchannel Solutions by ThermoKey. Core Remote Condenser Liquid Cooler

horizontal air discharge outdoor discus condensing unit

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

S-Therm Air to Water Heat Pumps

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

.2 Section Waste Management and Disposal.

Refrigeration Systems and Accessories

Summary of Research Activities. Eckhard A. Groll Professor of Mechanical Engineering

Kirby CO 2 Evaporators

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Inverter scroll compressors VZH hybrid manifold

Sweden s leading air source heat pump

Sabroe MatchMaster Program COMP1

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Reverse Cycle Chiller Models CHA24, 36, 48 & 60

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

MODELS LIST. Nominal Capacity RT

LOW RECIRCULATION RATE EVAPORATORS

Air-Cooled Condensing Units with Compact Screw Compressors

Gary Parker Refrigerants Product Manager

REDUCING AMMONIA REFRIGERANT CHARGE IN SKATING RINK REFRIGERATION SYSTEMS

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

FIRST IN RELIABILITY FIRST IN CHOICE

Design & Fabrication of Hybrid Cooler

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

MAC-120HE-03 Air-Cooled Chiller

Transcription:

A n I S O 9 0 0 : 2 0 0 0 O r g a n i z a t i o n Refrigeration Technologies Suction Line Accumulators With or without heat exchanger R4a R404A R07A R407C R22 R40A R08b R77 CO 2 Approved by European standards ENVIRONMENT FRIENDLY LESS ELECTRICITY CONSUMPTION WORLD CLASS TECHNOLOGY www.amoking.com www.seabird.in email:info@amoking.com

THE SEA BIRD GROUP The SEABIRD Group is today diversified into different industries, also at the forefront of Asian Compressors production. Since 98 SEABIRD has enjoyed continuous growth, and has invested heavily in highly advanced computerised production machinery, to ensure that quality and reliability of our products remain the foundation of our success. SEABIRD has production facilities in different parts of India and four service centres abroad, from where we service customers around the globe. SEABIRD is now market leader in the segment of high quality Compressors, Condensing Units, Pressure Vessels, Chillers and Cold Rooms which has always been the core business of the company's activities. SEABIRD is also ventured into Plastic industry, Automobile industry, Automation industry and software industry. Continuing investments for research and development into new products, together with the design of ultramodern plant, options and design. This is a success that has been consolidated over the years by the work of a flexible, dynamic and enthusiastic organization, in which the company culture is very much oriented towards quality, customer care and efficiency. A n I S O 4 0 0 : 2 0 0 4 O r g a n i z a t i o n A n I S O 9 0 0 : 2 0 0 0 O r g a n i z a t i o n Approved by European standards 2 Prestigious National Award Winner

SUCTION ACCUMULATORS APPLICATIONS Suction line accumulators are installed on refrigeration systems to prevent refrigerant liquid return to suction line to idled compressors. These systems include the following: systems with high temperature differences ( discontinuous operation), remote systems with long lines, systems with low evaporator load, reversing cycle systems: heat pump and defrost applications. Recommended for low superheat applications such as liquid chillers, low temperatures display cases, truck units, and so on Liquid+Gas Gas CHARACTERISTICS Complete separation of the vapour phase and the refrigerant fluid's liquid phase. Complete vaporization of the refrigerant liquid when the liquid leaves the Accumulators. Cooling of the vapour returning to compressor, thus reducing motor warm up. Pressure equalization at the Accumulators inlet and outlet, even in off cycle periods. Minimum pressure drop. Reduced noise on the low pressure side of the system. Positive oil return. Maximum efficiency of the relief device (expansion valve) because it is supplied with subcooled liquid. Enhanced evaporator performance. RECOMMENDATIONS For optimum operation, the velocity at which the refrigerant liquid passes through the tube baffles of the accumulator should be between 8 and 2 m/s. If the velocity of the gas in the piping is insufficient, oil return to the compressor is not assured. The selected liquid holding capacity should not be less than 0% of the total charge of refrigerant liquid in the installation. 0 The pressure drop in the accumulators should not go beyond 0. C. The suction line accumulators must be installed in a vertical position, as close to the compressor as possible and at the same level as compressor. Mounting always has to be done vertically, as close as possible to the compressor and at the same height. In order to avoid any frost on suction accumulators, Seabird strongly recommends to systematically insulate Suction Accumulators.

MODEL FITTING LIQUID TONS OF REFRIGERATION (EVAPORATOR TEMPERATURE)** SIZE HOLDING (D NOM.) CAPACITY Lbs SB28 /2" 0.6 0.8.2 0.8.0. 0.9.4 0.8. SB80 /8" 2. 0.8.2.7.2.6.4 2..0.2.9 2.7 SB82 /8".0 0.8.2.7.2.6.4 2..0.2.9 2.7 SB42 /4".0.0.6 2.. 2.6 2.8 4.0.6 2.. SB84 /8". 0.8.2.7.2.6.4 2..0.2.9 2.7 SB44 /4"..0.6 2.. 2.6 2.8 4.0.6 2.. SB26 /2" 2. 0.6 0.8.2 0.8.6. 0.9.4 0.8. SB8 /8" 2. 0.8.2.7.2.6.4 2..0.2.9 2.7 SB80 a /8".0 0.8.2.7.2.6.4 2..0.2.9 2.7 SB40 a /4".0.0.6 2.. 2.6 2.8 4.0.6 2.. SB49 /4" 6.0.0.6 2.. 2.6 2.8 4.0.6 2.. SB7 7/8" 6.0.0 2.8 4.0 2.7.6 4.6.. 7. 2.8 4. 6.2 SB42 a /4" 9.0.0.6 2.. 2.6 2.8 4.0.6 2.. SB782 7/8" 9.0 2.8 4.0 2.7.6 4.6.. 7. 2.8 4. 6.2 SB78 7/8" 0.0 2.8 4.0 2.7.6 4.6.. 7. 2.8 4. 6.2 SB8 /8" 0.0..0 7.2 4.4.9 7.6. 8. 4.6 7. 0.2 SB87 /8"..0 7.2 4.4.9 7.6. 8. 4.6 7. 0.2 SB87 /8" 4.6 7. 7.2 9.6 8..2 8.8 7.4.6 6. SB78 7/8" 2.8 4.0 2.7.6 4.6.. 7. 2.8 4. 6.2 SB78 a 7/8".0 2.8 4.0 2.7.6 4.6.. 7. 2.8 4. 6.2 SB8 a /8".0..0 7.2 4.4.9 7.6. 8. 4.6 7. 0.2 SB84 /8" 4.0 4.6 7. 7.2 9.6 8..2 8.8 7.4.6.6 SB87 /8" 7.0 7..7 7.0 4.2 8.2 2.8 20.0 28..0 7.2 24. SB820 /8" 20.0 7..7 7.0 4.2 8.2 2.8 20.0 28..0 7.2 24. SB82 /8" 7..7 7.0 4.2 8.2 2.8 20.0 28..0 7.2 24. Dimensional Drawing on request. R4a R404A/R07 R22 R02 8 C 7 C C 8 C 7 C C 8 C 7 C C 8 C 7 C C C (0 F) (+20 F) (+40 F) (0 F) (+20 F) (+40 F) (0 F) (+20 F) (+40 F) (0 F) (+20 F) (40 F) 4

Type MM SBR Inlet/ Outlet Connections in ODF Inches R2 Capacity in KG of refrigerant at 0 C R22 R407C Dimensions in mm R02 R4a R404A NH A B C E Total volume in litres Possible retention Volume in litres Drawing SB 04 2 ½ 0.8 94 0 0.9 0.4 SB 4 2 ½...2.2.2 294 0. 0.4 SB 24 2 ½.7 02 8 6 0. SB 0 6 /8 0.8 99 48 0.9 0. SB 6 /8...2.2.2 299 48. 0. SB 2 6 /8.7 02 6 6 SB 6 8 /4...2.2.2 299 7. SB 26 8 /4.7 02 6 6 0.9 SB 27 22 7/8.7 02 7 6 0.20 SB 47 22 7/8 2.8 2. 2.6 2.6 2.6 02 487 6.2 0.20 SB 67 22 7/8. 4.8 2. 2 40.8 0.2 SB 49 28 /8..2..2.2.6 2 42 49 4.0 0.28 SB 69 28 /8. 4.8 2. 2 4.8 0. SB 28 /8 7.2 6.. 2 7.4 0. SB 6 /8. 4.8 2. 2 42.8 SB 8 /8 7.2 6.. 2 4 7.4 SB 0 /8 9. 8.6 8.8 4.4 2 662 9.2 SB 8 42 /8 7.2 6.. 2 4 7.4 SB 0 42 /8 9. 8.6 8.8 4.4 2 662 9.2 SB 20 42 /8 20. 8. 9.0 9.0 9.0 9. 29 722 4 90 20 0.0 SB 7 4 2 /8. 4.0 4. 4. 4. 7.0 29 82 4 90 0.60 SB 87 4 2 /8 20. 8. 9.0 9.0 9.0 9. 29 72 4 90 20 0.60 SB 67 4 2 /8 6.0.0... 6. 24 700 SB 07 4 2 /8. 47.0 47. 47. 47. 24.0 24 900 0 SB 62 67 2 /8 6.0.0... 6. 24 700 2.60 SB 02 67 2 /8. 47.0 47. 47. 47. 24.0 24 900 0 2.60 SB 62 80 /8 6.0.0... 6. 24 700 2.90 SB 02 80 /8. 47.0 47. 47. 47. 24.0 24 900 0 2.90 SB 702 80 /8 72. 6.. 24 0 70 2.90 SB 7029 88.9 /8 72. 6.. 24 0 70.20 Max. Working Pressure 20 Bar ( P.S.I.)

Dimensional Drawing 2 4 6 282, Patparganj Industrial Estate, Patparganj, Delhi 0092 (INDIA) Tel: +92248267, 22684 Fax: +9224668 USA Address: 6 BENTLEY PL. BUFFALO GROVE, IL 600 USA Ph. 24864 www.amoking.com www.seabird.in email:info@amoking.com Printed on 00% recyclable paper. Printed with environment friendly ink.