TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

Similar documents
TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

INSTALLATION INSTRUCTIONS

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

TECHNICAL DATA & SERVICE MANUAL

SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

INSTALLATION INSTRUCTIONS

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Wall Mounted Split Systems

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

MULTI-SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

SPLIT SYSTEM AIR CONDITIONER

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

AIR-CONDITIONER SERVICE MANUAL

CU-3E23CBPG, CU- 4E27CBPG,

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Destination Europe WARNING

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

TEST RUN SERVICE MANUAL

[U] Serie MOV. Manual de Ingeniería

TABLE OF CONTENTS. Air Conditioner

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Operating Instructions Air Conditioner

INVERTER SPLIT SYSTEM AIR CONDITIONER

TABLE OF CONTENTS. Air Conditioner CS-MRE12MKE

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Multi Inverter Air Conditioning Condensing Units - Summary

Air-to-Water Hydromodule + Tank WH-UX12FE5 WH-UD12FE5 WH-UD16FE5. Destination Europe WARNING

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

Service Manual. Air Conditional

INSTALLATION INSTRUCTIONS

Installation Instructions

Air Conditioner SVC MANUAL(Exploded View)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

EEDEN technical data ERHQ AA

SPLIT SYSTEM AIR CONDITIONER

CK C O M P R E S S O R

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Air-to-Water Heatpump

MULTI F MAX OUTDOOR UNIT INSTALLATION MANUAL. Multi-Zone Heat Pump Systems 1.5 to 5 Tons. Dual and Tri-Zone Multi F.

TABLE OF CONTENTS. Air Conditioner CS-NE7GKE CU-NE7GKE CS-NE9GKE CU-NE9GKE CS-NE12GKE CU-NE12GKE

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Concealed Ducted Split Series R-407C MBH

2-WAY ECO-i MULTI SYSTEM

Transcription:

TECHNICAL DATA & SERVICE MANUAL OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AE22AH 387031006 AE28AH 387031007 AE38AH 387031008 AE22AC 387031009 AE28AC 387031010 AE38AC 387031011 AE42AC 387031043 AE42AH 387031048 AE22ACL 387031053 AE28ACL 387031054 AE38ACL 387031055 AE42ACL 387031056 0.8180.470.0 07/2005

IMPORTANT! Please read before installation This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently. For safe installation and troublefree operation, you must: Carefully read this instruction booklet before beginning. Follow each installation or repair step exactly as shown. Observe all local, state and national electrical codes. Pay close attention to all warning and caution notices given in this manual. The unit must be supplied with a dedicated electrical line. WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions. In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. SPECIAL PRECAUTIONS During installation, connect before the refrigerant system and then the wiring one; proceed in the reverse orden when removing the units. WARNING When wiring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM. Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked, to ensure the grounding. Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury and death. Ground the unit following local electrical codes. The Yellow/Green wire cannot be used for any connection different from the ground connection. Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan. Do not use multicore cable when wiring the power supply and control lines. Use separate cables for each type of line. When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers. When installing...... In a ceiling or wall Make sure the ceiling/wall is strong enough to hold the unitweight. It may be necessary to build a strong wooden or metal frame to provide added support.... In a room Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors.... In moist or uneven locations Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations.... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.... In a snowy area (for heat pumptype systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents. When connecting refrigerant tubing Keep all tubing runs as short as possible. Use the flare method for connecting tubing. Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them; screw by hand and then tighten the nut with a torque wrench for a leakfree connection. Check carefully for leaks before starting the test run. NOTE: Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion, the refrigerant tubing for your particular model is specified as narrow tube for liquid, wide tube for gas. When servicing Turn the power OFF at the main power board before opening the unit to check or repair electrical parts and wiring. Keep your fingers and clothing away from any moving parts. Clean up the site after the work, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced. Ventilate the room during the installation or testng the refrigeration system; make sure that, after the installation, no gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heatsources. 2

Table of Contents Page 1. OPERATING RANGE 4 2. SPECIFICATIONS 5 21 Unit specifications 5 22 Major Component specifications 9 23 Other Component specifications 13 3. DIMENSIONAL DATA 14 4. REFRIGERANT FLOW DIAGRAM 15 5. PERFORMANCE DATA 19 51 Performance Charts 19 52 Cooling Capacity 23 53 Heating Capacity 27 6. ELECTRICAL DATA 28 61 Electrical characteristics 28 62 Electric Wiring Diagram 32 63 System Wiring Diagram 35 3

1. OPERATING RANGE Cooling Heating Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Maximum Minimum Maximum Minimum 32 C D.B. / 23 C W.B. 21 C D.B. / 15 C W.B. 27 C D.B. 46 C D.B. 10 C D.B. / 10 C D.B.(*) 24 C D.B. / 18 C W.B. 9 C D.B. / 10 C W.B. (*) Only for models: AE22ACL AE28ACL AE38ACL AE42ACL 4

2. SPECIFICATIONS 21 Unit Specifications AE22AC/ACL/AH Power source Voltage rating 220 240V ~ 50Hz 230V Performance * Capacity Air circulation (High) Moisture removal (High) AW22AL kw BTU/h m³/h Liters/h Cooling 2,32 7920 0,8 380 Heating 2,44 8330 Electrical Rating Available voltage range V Running amperes A Power input W Power factor % C.O.P. W/W Compressor locked rotor amperes A Features Fan speed Compressor Refrigerant / Amount charged at shipment g Refrigerant control Power sound level Hi dba Refrigerant tubing connections Max. allowable tubing length at shipment m Refrigerant Narrow tube (in.) tube diameter Wide tube (in.) Cooling Heating 198 ~ 264 3,1 2,95 680 665 95 98 3,41 3,7 15 1(Hi) Rotary (Hermetic) R410A / 0,77 R410A / 0,89 Capillary tube 56 57 Flare type 7,5 6,35 (1/4") 9,52(3/8") Dimensions & Weight Unit dimensions Height 610 Width 795 Depth 290 Package dimensions Height 655 Width 945 Depth 395 Weight Net kg 31 32 Shipping kg 35 36 Shipping volume m 3 0,24 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks: Rating conditions are: Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. Heating: Indoor air temperature 20 C D.B. Outdoor air temperature 7 C D.B. / 6 C W.B. * For other INDOOR UNITS' MODELS, please refer to catalogue 5

AE28AC/ACL/AH Power source Voltage rating 220 240V ~ 50Hz 230V Performance * Capacity Air circulation (High) Moisture removal (High) AW28AL kw BTU/h m³/h Liters/h Cooling 2,75 9380 1,1 450 Heating 2,85 9720 Electrical Rating Available voltage range V Running amperes A Power input W Power factor % C.O.P. W/W Compressor locked rotor amperes A Features Fan speed Compressor Refrigerant / Amount charged at shipment g Refrigerant control Operation Sound Hi dba Refrigerant tubing connections Max. allowable tubing length at shipment m Refrigerant Narrow tube (in.) tube diameter Wide tube (in.) Cooling Heating 198 ~ 264 3,6 4 800 890 97 97 3,44 3,20 18,7 1(Hi) Rotary (Hermetic) R410A / 0,96 R410A / 1,0 Capillary tube 58 60 Flare type 7,5 6,35 (1/4") 9,52(3/8") Dimensions & Weight Unit dimensions Height 610 Width 795 Depth 290 Package dimensions Height 655 Width 945 Depth 395 Weight Net kg 34 35 Shipping kg 38 39 Shipping volume m 3 0,24 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks: Rating conditions are: Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. Heating: Indoor air temperature 20 C D.B. Outdoor air temperature 7 C D.B. / 6 C W.B. * For other INDOOR UNITS' MODELS, please refer to catalogue 6

AE38AC/ACL/AH Power source 220 240V ~ 50Hz Voltage rating 230V Performance * Capacity Air circulation (High) Moisture removal (High) AW38AL kw BTU/h m³/h Liters/h Cooling 3,63 12380 Heating 4,00 13640 635 1,5 Electrical Rating Available voltage range V Running amperes A Power input W Power factor % C.O.P. W/W Compressor locked rotor amperes A Features Fan speed Compressor Refrigerant / Amount charged at shipment g Refrigerant control Operation Sound Hi dba Refrigerant tubing connections Max. allowable tubing length at shipment m Refrigerant Narrow tube (in.) tube diameter Wide tube (in.) Cooling Heating 198 ~ 264 5,00 5,1 1115 1140 97 97 3,26 3,51 25 1(Hi) Rotary (Hermetic) R410A / 1,15 Capillary tube 62 64 Flare type 7,5 6,35 (1/4") 9,52(3/8") Dimensions & Weight Unit dimensions Height 610 Width 795 Depth 290 Package dimensions Height 655 Width 945 Depth 395 Weight Net kg 35 36 Shipping kg 39 40 Shipping volume m 3 0,24 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks: Rating conditions are: Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. Heating: Indoor air temperature 20 C D.B. Outdoor air temperature 7 C D.B. / 6 C W.B. * For other INDOOR UNITS' MODELS, please refer to catalogue 7

AE42AC/ACL/AH Power source 220 240V ~ 50Hz Voltage rating 230V Performance * Capacity Air circulation (High) Moisture removal (High) AW42AL kw BTU/h m³/h Liters/h Cooling 4,00 13640 Heating 4,48 15280 660 1,5 Electrical Rating Available voltage range V Running amperes A Power input W Power factor % C.O.P. W/W Compressor locked rotor amperes A Features Fan speed Compressor Refrigerant / Amount charged at shipment g Refrigerant control Operation Sound Hi dba Refrigerant tubing connections Max. allowable tubing length at shipment m Refrigerant Narrow tube (in.) tube diameter Wide tube (in.) Cooling Heating 198 ~ 264 6,1 6,5 1330 1395 95 93 3,01 3,21 30 1(Hi) Rotary (Hermetic) R410A / 1,34 Capillary tube 63 64 Flare type 7,5 6,35 (1/4") 12,7(1/2") Dimensions & Weight Unit dimensions Height 610 Width 795 Depth 290 Package dimensions Height 655 Width 945 Depth 395 Weight Net kg 41,5 42,2 Shipping kg 45,5 46,5 Shipping volume m 3 0,24 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks: Rating conditions are: Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. Heating: Indoor air temperature 20 C D.B. Outdoor air temperature 7 C D.B. / 6 C W.B. * For other INDOOR UNITS' MODELS, please refer to catalogue 8

22 Major Component Specifications Outdoor Unit: AE22AC/ACL/AH Compressor Type Compressor model Nominal output Compressor oil Amount Coil resistance (Ambient temp. 25 C) W cc. Ω Safety devices Type Overload relay Operating Temp. Open C Close C Run capacitor µf VAC Fan & Fan Motor Type Q'ty. Dia. Fan motor model Q'ty No. Of poles rpm (230 V, High) Nominal output Coil resistance (Ambient temp. 20 C ) Safety devices W Ω Ω Ω Type Operating temp. Open C Close C Run capacitor µf VAC Heat Exch. Coil Coil Rows Fin pitch Face area m 2 External Finish Rotary (Hermetic) GK086PAE 2022 (at 220V) FVC68D 330±10 CR: 4,8 CS: 4,76 External protector MRA9885412026 150±5 75±9 25 370 Propeller 1. Ø 400 YYK30Z6 1 6 680 16 Internal thermal protector 130 1,5 400 Aluminium plate fin / Copper tube 1 1,4 0,454 Acrylic bakedon enamel finish 9

Outdoor Unit: AE28AC/ACL/AH Compressor Type Compressor model Nominal output Compressor oil Amount Coil resistance (Ambient temp. 20 C) W cc. Ω Safety devices Type Operating Temp. Open C Close C Run capacitor µf VAC Fan & Fan Motor Type Q'ty. Dia. Fan motor model Q'ty No. Of poles rpm (230 V, High) Nominal output W Coil resistance (Ambient temp. 20 C ) Ω Ω Ω Safety devices Type Operating temp. Open C Close C Run capacitor µf VAC Heat Exch. Coil Coil Rows Fin pitch Face area m 2 External Finish Rotary GK113PAG 2637 (at 220V) FVC68D 330±10 CR:4.02 CS:4.19 External MRA1213012026 150±5 69±9 30 370 Propeller 1. Ø 400 YDK306V 1 6 780 23 Internal thermal protector 130 2 400 Aluminium plate fin / Copper tube 2 1,7 0,452 Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE 10

Outdoor Unit: AE38AC/ACL/AH Compressor Type Compressor model Nominal output Compressor oil Amount Coil resistance (Ambient temp. 20 C) W cc. Ω Safety devices Type Operating Temp. Open C Close C Operating current (at 25 C) A Run capacitor µf VAC Rotary PA145X2C4FT 3520 (at 220V) RB68AF/T68/α68TF 480 CR:2,35 CS:3,22 Internal UP3RE0591T56 29,9 35 370 Fan & Fan Motor Type Q'ty. Dia. Fan motor model Q'ty No. Of poles rpm (230 V, High) Nominal output W Coil resistance (Ambient temp. 20 C ) Ω Ω Ω Safety devices Type Operating temp. Open C Close C Run capacitor µf VAC Heat Exch. Coil Coil Rows Fin pitch Face area m 2 External Finish Propeller 1. Ø 400 YDK246V 1 6 810 25 Internal thermal protector 130 2 400 Aluminium plate fin / Copper tube 2 1,7 0,452 Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE 11

Outdoor Unit: AE42AC/ACL/AH Compressor Type Compressor model Nominal output Compressor oil Amount Coil resistance (Ambient temp. 20 C) W cc. Ω Safety devices Type Operating Temp. Open C Close C Operating current (at 25 C) A Run capacitor µf VAC Rotary RN 165 VHSMT 4070 (at 220V) MEL56 520 CR:2,23 CS:4,07 Internal UP3QF0501T56 150±5 90±10 Trip in 3 to 10 s at 36A 30 400 Fan & Fan Motor Type Q'ty. Dia. Fan motor model Q'ty No. Of poles rpm (230 V, High) Nominal output W Coil resistance (Ambient temp. 20 C ) Ω Ω Ω Safety devices Type Operating temp. Open C Close C Run capacitor µf VAC Heat Exch. Coil Coil Rows Fin pitch Face area m 2 External Finish Propeller 1. Ø 400 YDK030S6221303 1 6...910 30 Internal thermal protector 130 2 400 Aluminium plate fin / Copper tube 3 1,6 0,436 Acrylic bakedon enamel finish DATA SUBJECT TO CHANGE WITHOUT NOTICE 12

23 Other Component Specifications Outdoor Unit: 4way Valve (20S) Coil rating Coil resistance Outdoor sensor Resistance AE22AC/ACL/AH AE28AC/ACL/AH Ω (at 20 C) Ω (at 25 C) SQ213(Coil) SHF4H23U(Valve) AC 220/240V,50Hz,6W 10K±2% AE38AC/ACL/AH 4way Valve (20S) Coil rating Coil resistance Ω (at 20 C) SQ213(Coil) SHF7H34U(Valve) AC 220/240V,50Hz,6W Outdoor sensor Resistance Ω (at 25 C) 10K±2% AE42AC/ACL/AH 4way Valve (20S) Coil rating Coil resistance Ω (at 20 C) SQ213(Coil) SHF7H34U(Valve) AC 220/240V,50Hz,6W Power Relay Type Coil Rating Coil resistance Ω (at 20 ) CJX9B25S/01TH AC 220/230V,50Hz/60Hz 1100Ω±10% Contact Rating 25A Outdoor sensor Resistance Ω (at 25 C) 10K±2% AE22ACL AE28ACL AE38ACL AE42ACL Low ambient kit Rating Setpoint MPa RGEZ1L65B AC 230V 50 Hz 2.4±0.05 13

3. DIMENSIONAL DATA 14

4. REFRIGERANT FLOW DIAGRAM Indoor Unit: AW22AL Outdoor Unit: AE22AC/ACL/AH 15

Indoor Unit: AW28AL Outdoor Unit: AE28AC/ACL/AH 16

Indoor Unit: AW38AL Outdoor Unit: AE38AC/ACL/AH 17

Indoor Unit: AW42AL Outdoor Unit: AE42AC/ACL/AH 18

5. PERFORMANCE DATA 51 Performance charts AE22AC/ACL/AH Cooling Characteristics Heating Characteristics Notes: Points of Rating condition Data related to matching with AW22AL 19

AE28AC/ACL/AH Cooling Characteristics Heating Characteristics Notes: Points of Rating condition Data related to matching with AW28AL 20

AE38AC/ACL/AH Cooling Characteristics Heating Characteristics Notes: Points of Rating condition Data related to matching with AW38AL 21

AE42AC/ACL/AH Cooling Characteristics Heating Characteristics Notes: Points of Rating condition Data related to matching with AW42AL 22

52 Cooling Capacity OUTDOOR UNIT: INDOOR UNIT: AE22AC/ACL/AH AW22AL 220 240V ~ 50Hz RATING CAPACITY 2,32 kw moisture removal 0,8 l/h POWER INPUT 0,68 kw max power input 0,8 kw AIR FLOW RATE 380 m³/h RATING CONDITIONS Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. NOTE: Data related to matching with AW22AL 23

OUTDOOR UNIT: INDOOR UNIT: AE28AC/ACL/AH AW28AL 220 240V ~ 50Hz RATING CAPACITY 2,75 kw moisture removal 1,1 l/h POWER INPUT 0,8 kw max power input 1 kw AIR FLOW RATE 450 m³/h RATING CONDITIONS Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. NOTE: Data related to matching with AW28AL 24

OUTDOOR UNIT: INDOOR UNIT: AE38AC/ACL/AH AW38AL 220 240V ~ 50Hz RATING CAPACITY 3,63 kw moisture removal 1,5 l/h POWER INPUT 1,115 kw max power input 1,5 kw AIR FLOW RATE 635 m³/h RATING CONDITIONS Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. NOTE: Data related to matching with AW38AL 25

OUTDOOR UNIT: INDOOR UNIT: AE42AC/ACL/AH AW42AL 220 240V ~ 50Hz RATING CAPACITY 4,00 kw moisture removal 1,5 l/h POWER INPUT 1,33 kw max power input 1,8 kw AIR FLOW RATE 660 m³/h RATING CONDITIONS Cooling: Indoor air temperature 27 C D.B. / 19 C W.B. Outdoor air temperature 35 C D.B. / 24 C W.B. NOTE: Data related to matching with AW42AL 26

53 Heating Capacity 120% 100% Heating capacity ratio (%) 80% 60% 40% 20% 0% 15 10 5 0 5 10 15 20 25 Outdoor temperature ( C W.B.) NOTE 1 Black dot in the chart indicates the following rating condition. Indoor: 20 C D.B. Outdoor: 7 C D.B. / 6 C W.B. 2 The above chart includes the weighted deicing influence 27

6. ELECTRICAL DATA 61 Electrical characteristics OUTDOOR UNIT: AE22AC/ACL/AH COOLING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 3,10 0,680 Rating Conditions: Indoor Air Temperature 27 C D.B. / 19 C W.B. Outdoor Air Temperature 35 C D.B. HEATING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 2,95 0,665 Rating Conditions: Indoor Air Temperature 20 C D.B. Outdoor Air Temperature 7 C D.B. / 6 C W.B. Full load conditions Running Amps. A 3,8 28

OUTDOOR UNIT: AE28AC/ACL/AH COOLING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 3,60 0,800 Rating Conditions: Indoor Air Temperature 27 C D.B. / 19 C W.B. Outdoor Air Temperature 35 C D.B. HEATING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 4,00 0,890 Rating Conditions: Indoor Air Temperature 20 C D.B. Outdoor Air Temperature 7 C D.B. / 6 C W.B. Full load conditions Running Amps. A 5,8 29

OUTDOOR UNIT: AE38AC/ACL/AH COOLING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 5,00 1,115 Rating Conditions: Indoor Air Temperature 27 C D.B. / 19 C W.B. Outdoor Air Temperature 35 C D.B. HEATING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 5,10 1,140 Rating Conditions: Indoor Air Temperature 20 C D.B. Outdoor Air Temperature 7 C D.B. / 6 C W.B. Full load conditions Running Amps. A 7,4 30

OUTDOOR UNIT: AE42AC/ACL/AH COOLING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 6,10 1,330 Rating Conditions: Indoor Air Temperature 27 C D.B. / 19 C W.B. Outdoor Air Temperature 35 C D.B. HEATING Complete Unit performance at Rating conditions Running Amps. A Power input Kw 230V 1Phase 50 Hz 6,50 1,395 Rating Conditions: Indoor Air Temperature 20 C D.B. Outdoor Air Temperature 7 C D.B. / 6 C W.B. Full load conditions Running Amps. A 8,5 31

62 Electric Wiring Diagram OUTDOOR UNIT: AE22AH OUTDOOR UNIT: AE22AC AE28AH AE38AC AE28AC AE38AH 32

OUTDOOR UNIT: AE42AC AE42AH OUTDOOR UNIT: AE42ACL 33

OUTDOOR UNIT: AE22ACL AE28ACL AE38ACL 34

63 System Wiring Diagram OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH 35

Via Varese, 90 21013 Gallarate Va Italy Tel. +39 0331 755111 Fax +39 0331 776240 www.argoclima.it