Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Similar documents
TEMPERATURE CONTROLLER

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Series Temperature Controller Instruction Sheet

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

E3M-V. Mark Sensor. Applications

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Ultrasonic Proximity Sensor

SHIMADEN DIGITAL INDICATORS

Ultrasonic Proximity Sensor

MICRO CONTROLLER S Z SERIES

onlinecomponents.com

Model Number Structure

Temperature Controllers E5CSV

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

DIGITAL INDICATOR DI25

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

02/11/2015

E5CN/E5CN-U (48 x 48 mm)

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

DIGITAL INDICATOR JIR-301-M

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

GCS-300 No.GCS31E

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

02/11/2015

Digital Heater Element Burnout Detector K8AC-H

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

UDC 700 Universal Digital Controllers and Indicator Specifications

CII FCAC-150 Series Relay

Temperature Controllers

Digital Temperature Controller

AE500 Instruction Manual

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

E5CN Temperature Controller User s Manual

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

PID Temperature Controller. ITC-100 User Manual. Version 2.0s. Inkbird Tech. Co., Ltd.

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

F4 Process Controller Installation and Operation Guide

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

CN4800 Series CONTROLLER

INSTALLATION INSTRUCTIONS

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Cat. No. H113-E1-03B E5ZN. Temperature Controller OPERATION MANUAL

INSTALLATION INSTRUCTIONS

ST Wiring diagram. Product description. Standard temperature controller. Order number

Process & TeMPerATUre UniversAl input DigiTAl MeTers

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

SR70 (SR ) Series Digital controller Instruction Manual

Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Table of Contents. Protective Relays

DE20 INSTRUCTION MANUAL

Series Digital Controller Instruction Sheet

The next generation thermometer from the global leader

Laser Collimated Beam Sensor

PCR-300 PCR-300 RC. Installation and Operating Instructions

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

MICROJET RECORDER (24-CHANNEL 180mm)

0-10 V Wall & Duct Humidistat Installation Instructions

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

E3FA PHOTOELECTRIC SENSORS

Instruction manual for DIN rail mounting type indicating controller DCL-33A

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Transcription:

Digital Panel Meter Low-cost, High-quality Digital Thermometer with Built-in Microcomputer Compact DIN-size (96 x 48 x 66 (W x H x D)) body. Mounting thickness of only 3.5 mm required. Highly visible display with 14.2-mm-high LEDs. Multi-temperature range incorporated. Upper or lower limit selectable (models with alarm output). Water-resistant (IP51) construction (optional). Ordering Information Temperature Range Item Thermocouple Platinum resistance thermometer Input K(CA) J/L (IC) Pt100/JPt100 Temperature range 400%C 400%F 999%C 999%F 300%C 400%F 500%C 999%F 99.9%C 99.9%F Range selection 4-range selectable 3-range selectable Model Display only -TA11 -TB11 With alarm -TA11-C output The %Cor%F display can be selected. For details, refer to Measuring Ranges. Model Number Legend - - 1 2 3 4 5 1, 2. Input Sensor Code TA: Thermocouple (K, J) TB: Platinum resistance thermometer (Pt) 3. Series No. 1: Current series Accessories (Order Separately) -TB11-C 400%C 800%F 4. Supply Voltage 1: 100 to 240 VAC 8: 24 VAC (24-VAC type is available by request.) 5. Output None: Without relay output C: With relay output Name Appearance Model Water-resistive Soft Front Cover K32-L49SC -- 5 50%C 200%F Terminal Cover K32-L49TC 1

Specifications Ratings Supply voltage Operating voltage range Power consumption Insulation resistance Dielectric withstand voltage Noise immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity Ambient atmosphere 100 to 240 VAC (50/60 Hz) --15% to +10% of supply voltage 6.6 VA (at max. load) (see note) 10 MW min. (at 500 VDC) between external terminal and case 2,000 VAC min. for 1 min between input terminal and power supply 2,000 VAC min. for 1 min between external terminal and case +1,500 V on power supply terminals in normal or common mode Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Malfunction: 100 m/s 2 (approx. 10G) for 3 times each in 6 directions Destruction: 300 m/s 2 (approx. 30G) for 3 times each in 6 directions Operating: --1 55%C (with no icing) Storage: --2 65%C (with no icing) Operating: 35% to 85% (with no condensation) Must be free of corrosive gas An inrush current of approximately 1.0 A will flow at the moment power is turned on and continue for approximately 5 ms. Output Ratings Item Resistive load (cosf = 1) Inductive load (cosf = 0.4,L/R = 7 ms) Rated load 5 A at 250 VAC; 5 A at 30 VDC 1.5 A at 250 VAC; 1.5 A at 30 VDC Rated carry current Max. contact voltage Max. contact current 5 A max. (at COM terminal) 380 VAC, 125 VDC 5 A max. (at COM terminal) Max. switching capacity 1,250 VA, 150W 375 VA, 80 W Min. permissible load Characteristics 10 ma at 5 VDC Measuring accuracy +0.5% FS +1 digit (see note 1) Input Thermocouple: K (CA), J/L (IC) Platinum resistance thermometer: JPt100/Pt100 Sampling period Display refresh period Display Display scale 2times/s 2 s (average of 4 sampling data) 7-segment LED %C or%f display selectable Input shift -- 99% to 99%C/%F or--9.9% to 9.9%C/%F (see note 2) Alarm output function Enclosure ratings Output configuration: Relay contact (SPDT) Upper or lower range selectable with DIP switch Front panel: IEC IP51 (see note3) Case: IEC IP20 Terminals: IEC IP00 1. The measuring accuracy is at an ambient temperature of 25%+5%C. 2. This applies only to a platinum resistance thermometer with an input range of 99.9%C/%F. 3. IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive accessories. 2

Measuring Ranges Input Measuring ranges Hysteresis (see note) Thermocouple K 400%C 400%F 1%C/%F 999%C 999%F 1%C/%F J/L 300%C 400%F 1%C/%F 500%C 999%F 1%C/%F Platinum resistance thermometer 0. 99.9%C 0. 99.9%F 0.1%C/%F 400%C 800%F 1%C/%F -- 5 50%C 200%F 1%C/%F Hysteresis of alarm output set value (fixed value for each range) Nomenclature Alarm display PV display Unit name Operation The lower part of the front panel cover has two grooves. Hook the grooves with a flat-blade screwdriver or fingernails to remove the cover before operating the. Without cover Up key Down key DIP switches Name DIP switches Up/Down Key Function Used to select input range, display unit, alarm mode. Used to select alarm set value and input compensation value. 3

DIP Switch The DIP switch pins are all set to before shipping. Refer to the following tables for setting the DIP switch. Be sure to turn off the power before changing the settings of the DIP switch other than pin 6. Thermocouple Models (-TA) 1 2 3 4 5 6 Function Pin no. Pin setting Input range K 400%C 400%F 1/2 / 999%C 999%F / J/L 300%C 400%F / 500%C 999%F / Specification (see note) K, L (DIN) 3 K, J (JIS) Scale %F 4 Alarm mode %C Lower-limit (relay operates for values less than the set value) Upper-limit (relay operates for values more than the set value) 5 Input compensation function Input compensation value set mode 6 Usually set to If a K-type sensor is used, you can set pin 3 to either or. Platinum Resistance Thermometer Models (-TB) 1 2 3 4 5 6 Function Pin no. Pin setting Input range 99.9%C 99.9%F 1/2 / 400%C 800%F / - 5 50%C 200%F / Specification Pt100 3 JPt100 (JIS 1981) Scale %F 4 Alarm mode %C Lower-limit (relay operates for values less than the set value) Upper-limit (relay operates for values more than the set value) 5 Input compensation function Input compensation value set mode 6 Usually set to 4

Operation Timing of Alarm Output Temperature change Set value Hysteresis Hysteresis Relay operation in upper limit alarm mode Relay operation in lower limit alarm mode Operating Procedures Alarm Value Setting Setting Range --99 to 999 or --9.9 to 99.9 (%C/%F) regardless of the temperature range that you have selected. No key operation for 2 s. PV display 123 Alarm set value display 150. Up Key or Down Key Up Key or Down Key Press the Up Key or Down Key once to display the alarm set value with a decimal to the right of the rightmost digit. If the succeeding key operation is not executed for 2 s, the display returns to the present value automatically. Press the Up Key or Down Key for appropriate times to change the value to the desired alarm set value. Fixed2s later. Alarm set value display 160. No further The alarm set value will be fixed 2 s after completion of key operation, and key operation then the display will return to the present value automatically. for 2 s. If you change the temperature range after you set the alarm set value, the new alarm set value will remain unchanged. If you change the display unit, the alarm set value will not be converted from the %C to%f value or vice versa. If you remove or add the decimal point from or to the display, the display value will change as follows: Range change 90.0. 900. With decimal Without decimal 5

Input Compensation (Shift) Setting PV display 123 Input compensation display h0 DIP switch 6 Turn DIP switch 6 1 2 3 4 5 6 Up Key or Down Key Press Up Key or Down Key for appropriate times to change the value to the desired input compensation set value. Input compensation display l3 Decided DIP switch 6 Turn off DIP switch 6 to complete. 1 2 3 4 5 6 Possible Compensation Range for Each Temperature Range Temperature range Platinum resistance thermometer 0.0 to 99.9 (%C/%F) Possible compensation range --9.9to9.9(%C/%F) --99 to 99 (%C/%F) Input compensation display l9.9 to h9.9 l99 to h99 Other ranges Example of Compensation Input compensation value display Sensor measurement temperature Displayed temperature h 0 (With no compensation) 100%C 100%C h 9 (9%C compensation) 100%C 109%C l 9 (-9%C compensation) 100%C 91%C If you change the temperature range after you set the input compensation, the new input compensation will remain unchanged. If you remove or add the decimal point from or to the display, the display value will change as follows: Range change h1.9 h19 With decimal Display with Sensor Error Thermocouple Without decimal Condition Message Alarm output Disconnected fff (flashes) The room temperature will be displayed if the input terminals are short-circuited. 6

Platinum Resistance Thermometers Condition Message Alarm output Disconnected fff (flashes) - - - (flashes) Breaks in 2 or 3 wires. fff (flashes) Short-circuited - - - (flashes) The Pt has a resistance of 100 W at a temperature of 0%C and approximately 140 W at a temperature of 100%C. Error Messages The following table lists the error messages and the meaning of the error messages. fff Message Cause Alarm output Remedy The input temperature value is higher than the permissible measuring range. - - - The input temperature value is lower than the permissible measuring range. fff (flashes) - - - (flashes) e11 e33 A sensor error has occurred or the sensor temperature is far higher or lower than the permissible measuring range. A memory error (E11) or AD converter error (E33) has occurred. The present setting will be put on hold. The present setting will be put on hold. Limit the input temperature value within the permissible range. Limit the input temperature value within the permissible range. Remove the cause of the sensor error by referring to the error message. Turn power on again. If the is still not reset, consult your OMR representative. 7

Dimensions All units are in millimeters unless otherwise indicated. (98) 92 Panel Cutouts 92 +0.8-0 45 +0.6-0 75 min. 120 min. LED Indicator Size 48 45 14.2 mm 96 3.5 66 7.8 mm Installation External Connection 1 2 3 4 5 6 7 8 9 Platinum resistance thermometer A B B Unused Thermocouple + -- Temperature sensor input Alarm output AC power supply Terminals 5, 6, and 7 are not used by models with no alarm output. (These terminals are open only for models incorporating the display function.) Precautions Mounting Recommended panel thickness is 1 to 3.2 mm. Mount the Digital Panel Meter by attaching the mounting bracket supplied as an accessory from the rear of the Digital Panel Meter, hook the mounting bracket to the Digital Panel Meter securely, and tighten the mounting screws by turning them clockwise with a tightening torque of 5 kgf $ cm (0.49 N $ m). For dismounting, loosen the screws and widen the hooks. Always attach the Mounting Bracket before wiring the terminals. Also, always remove the wiring before removing the Mounting Bracket. Mount the Digital Panel Meter as horizontally as possible. Never use the Digital Panel Meter in locations where corrosive gas (particularly sulfureted or ammonia gas) is generated. As much as possible avoid use of the Digital Panel Meter in a location subject to severe shock or vibration, excessive dust, or excessive moisture. Select a mounting location where the Digital Panel Meter can be used at an ambient operating temperature --1 55%C. No product is shipped with the unit label attached. Select a unit label from the sheet provided, and attach it to the Digital Panel Meter. 8

Others After the front panel cover is removed to select the function or perform the necessary settings, do not touch components other than the dip switch or keys. Keep metal objects off the, especially when power is turned on. Accessories (Order Separately) Water-resistive Soft Front Cover Before mounting the Digital Panel Meter to a panel, attach the water-resistive soft front cover and mounting bracket to the DigitalPanel Meter properly so that the Digital Panel Meter will maintain IP51 water-resistive standards. Before you calibrate Digital Panel Meters, remove the water-resistive soft front cover. Induced Noise If induced noise is a problem, shield the Digital Panel Meter with a metal cover and ground the metal cover. To reduce induced noise on the input lines, use a two-wire shielded cable, and connect the shield wire to the negative terminal at a point on the signal source. Two-wire shield cable Input + -- Digital panel meter Mounting Bracket Soft Cover Be sure to use the Water-resistive Soft Front Cover and mounting bracket together. Counter-measures Against Noise Power Supply Although all possible counter-measures against noise have been taken on the digital panel meter, the Digital Panel Meter cannot resist excess noise. If a power relay, magnetic switch, or high-frequency device is connected to the power supply line or if there is a high-voltage spark or abnormal voltage generation due to lightning, connect a noise absorption circuit such as a line filter, noise-cut transformer, or varistor to the Digital Panel Meter. Line filter Digital panel meter + Input -- Digital panel meter Power supply Surge absorber 9

ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. N075--E1--1 OMR Corporation Supervisory Control Devices Division 29th Fl., Crystal Tower Bldg. 1--2--27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6075 Fax: 06-949-6084 10 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0692--1M (0692)