Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

Similar documents
Metal, ceramic, plastic package products

Preliminary specification

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Read this Safety Guide first.

Ionizer (Static Remover) STABLO-EX Instruction Manual

Handling Note SHARP COB ZENIGATA LED SERIES

IAQ_100 C Package

Application Notes For LED Displays

Toshiba Memory Corporation Semiconductor Handling Precautions and Requests

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

APPLICATION NOTES for LED DISPLAYs

INTELLIGENT LEAD FREE SOLDERING STATION INSTRUCTION MANUAL V1.0 WARNING

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

PRODUCT SPECIFICATION

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Adhesive for chip mounting machines , Nagata Higashi, Higashi Osaka-city, Osaka, , Japan TEL: FAX:

BK3300/BK3300L. Intelligent Lead free Soldering Station. Instruction Manual V1.0. Warning

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

3SP_H2S_50 Package

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

PRODUCT SPECIFICATION

Pyroelectric Infrared Sensors

High Power COB LED. Features. Applications. ① Product line code: COB10W-C & COB10W-W. ② Product code base plate. ③ Chip code. ④ Emitting light colours

Coway Air Purifier AP-1008DH

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Background. Totech dry cabinet

Cleaning (Preventative Maintenance) on the magicolor 2400 Series

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

ELIMINOSTAT DC-ESR-CL-S2

EMI Filter (Data Line) TRIGON COMPONENTS. Dimensions Table (mm)

OPERATING INSTRUCTIONS WPSI12. Portable Soldering Station & TCP12. Soldering Tool. Weller Tech Sheet Product Code: Issue A 24/05/05

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

PRODUCT SPECIFICATION

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Instruction Manual. for. Intelligent Temperature Controlled Soldering Station LF-2000 (U)

Pyroelectric Infrared Sensors

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

CRISTAL Built-in Dish Sterilizer Instruction Manual

EQGA AND EQGB HYGIENIC VERSION, CODE SUFFIX I = 3 AND 4

FEATURES ORDERING CODE EMCP C 100 N T (1) (2) (3) (4) (5) (6) (7) SMT Multilayer EMI Filter (Power Line) TRIGON COMPONENTS

User manual INFRARED REMOTE CONTROLLER SIR-15

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

MIMAKI ENGINEERING CO., LTD.

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

MA Remote Controller PAR-31MAA

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Checking the components Safety information Operating the product Other information

FEATURES ORDERING CODE KED ST D T (1) (2) (3) (4) (5) (6) (7) Transient Voltage Suppressors (ESD Diodes) TRIGON COMPONENTS

Bosch Split-Type Ductless Air Conditioner / Heat Pump

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

3 3SP_O3_5 C Package

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

Cree XLamp CM Family LEDs

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

Catalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

ZEN MIRROR. Install / Operating Manual. Table of Contents

Operating Instructions Air Conditioner

SPØ1 OUTDOOR CARE INSTRUCTIONS

Installation Instructions Part No

Electron Microscopy Sciences

Owner s Manual Super-Slim Four-Way Cassette

Specification MBT801-S

Piezo-electric Devices Precaution Usage

A Specifications. Ver.1.1. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

AIR COOLER OPERATING INSTRUCTIONS MODEL NO: ARC-30 ARC-30. Instruction Manual

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Operating Instructions

INSTRUCTION MANUAL FOR

Coway Air Purifier AP-1008BH/CH

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

15,000 BTU Portable Air Conditioner

Requests for Care and Maintenance

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

Ultrasonic Aroma Diffuser AD-SD1-CE

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities

Reference Specification

Forehead Thermometer Instruction Manual

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

Catalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.

Air-Quality Gas Sensor (Model: MP905) Manual. Version:1.1. Valid From: Zhengzhou Winsen Electronics Technology Co., Ltd

INSTRUCTION MANUAL SD and SDB Cabinets

MEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.

SOLDER POT POT-100C / 103C POT-200C / 203C

JT-SB116JH-G-NA JT-SB116JH-W-NA

Transcription:

LCD Module Precautions for LCM handling Application note LCM handling V 1.1 admatec GmbH Wendenstrasse 29, 20097 Hamburg, Germany Tel.: +49-40-238533-0, Fax: +49-40-238533-11 Internet: www.admatec.de, Email: info@admatec.de

Revision record Table 0.1: Revision record Rev. Date Chapter Description 1.0 2013-04-23 all initial release 1.1 2013-08-28 all minor spellings 2/8

Table of content Subject Page 1 Introduction 4 1.1 Static electricity 4 1.2 Handling of LCMs 5 1.3 Soldering 6 1.4 Cleaning 6 1.5 Mounting 6 1.6 Storage 7 1.7 Precautions for Operation 7 1.8 Safety 8 3/8

1 Introduction This document describes a collection of rules admatec has defined and collected over many years. Its purpose is to help customers best in handling LCMs correctly to avoid any malfunction of LCMs due to incorrect handling. The display panel is made of glass and polarizer. As glass is fragile, it tends to or become chipped during handling especially on the edges. Please avoid mechanical shocks by dropping it and do not apply any excessive force on the surface. Operate LCMs within the specified ranges and do not tamper the printed circuit board. 1.1 Static electricity LCMs contain standard CMOS ICs. When handling an LCM, take sufficient care to prevent static electricity discharge as it would damage any CMOS IC. The recommended relative humidity in the working area is 50-60%RH. Moreover, please pay attention to the following points: Ground yourself with ground strap Use antistatic gloves 4/8 The modules are coated with a film to protect the display surface from contamination, adhesion of flux, etc. Remove the protective film slowly and, if possible, under ESD control device like ion blower. Abruptly removing could cause static electricity to be generated. Do not take the LCM from its anti-static bag until assembly. LCM s are individually packaged in bags specially treated to resist static electricity Never touch any of the conductive parts such as the LSI pads, the copper leads on the PCB and the interface terminals The operators should use a ground strap when handling a LCM Assure that the workbench is properly grounded Always ground electrical equipment required for assembly

1.2 Handling of LCMs 1.2.1 Correct handling Please handle with anti-static gloves. Hold LCMs on LCM edges as they are easy to damage. 1.2.2 Incorrect handling Don t touch IC directly Don t stack LCM Don t hold the surface of panel Don t stretch interface (like FPC) Don t use sharp tools on surface Don t use hard tools on surface 5/8

1.3 Soldering The following procedures should be followed when soldering the LCM: Use soldering irons with proper grounding and no leakage. For hand soldering the temperature shall not be higher than 310±10 C and applied less than 3 sec per terminal. Limit soldering of the printed circuit board to I/O terminals only. Type of solder: Eutectic solder (rosin flux filled). Note: Avoid using flux, because it could penetrate the module and the module may get contaminated during cleaning. Peel off protective film after soldering of the I/O terminals is done. By following this procedure, the surface contamination, caused by the dispersion of flux while soldering, can be avoided. If soldering flux is used, be sure to remove any remaining flux after finishing the soldering operation (this does not apply in the case of a non-halogen type of flux.) Protect the LCD surface with a cover during soldering to prevent any damage due to flux spatters. 1.3.1 Re-soldering Do not re-solder more than 3 times. 1.4 Cleaning When cleaning the LCMs surface, gently wipe it by using soft cloth moisten with solvent (Isopropyl alcohol, Ethyl alcohol or Trichlorotrifluoroethane). Solvents other than the above-mentioned may damage the polarizer. Especially, do not use water, ketone or aromatics. Wipe off water drops immediately, contact with water over a long period of time may cause deformation or color fading. Avoid contacting oil and fats. Do not wipe the displays surface with dry or hard materials because that will damage the polarize surface. Do not wipe ITO pad area with the dry or hard materials that will damage the ITO patterns. Do not use the following solvent on the pad or prevent it from being contaminated: Soldering flux, Chlorine (Cl) or Sulfur (S). Do not use any detergent to clean mounted PCB after soldering, because the detergent can penetrate between the individual layers of the LCM, causing unwanted optical effects. 1.5 Mounting When mounting the LCM, make sure it is free of twisting, warping and distortion. In particular, do not forcibly pull or bend the I/O cable or the backlight cable. 6/8

1.6 Storage Please follow the correct method of storage as otherwise deterioration of the display material (polarizer) and oxidation of the I/O terminal plating may take place and thus, the soldering process may become difficult. Store them in a sealed polyethylene bag. If properly sealed, there is no need for the desiccant. When storing, keep the LCM packed in the original bags, or store them in a container processed to be resistant to static electricity, or in an electric conductive container. Store in ambient temperature of 25±5 C, and keep the relative humidity of 50±10%RH. Store LCMs in the dark ambient. Do not expose LCMs to direct sunlight or fluorescent light. Store within the specified storage temperature range. Store in a clean environment, free from dust, active gas or solvent. The polarizer surface should not come in contact with any other objects. Store without any physical load. 1.6.1 Long-term storage Store in the shipping container. If the shipping container is not available, place LCMs in anti-static bags and seal the opening. 1.7 Precautions for Operation Viewing angle varies with the change of liquid crystal driving voltage (V LCD ). Adjust V LCD to show the best contrast. Sometimes V LCD is referred as V OP. Drive LCMs within the specified voltage limit since the higher voltage can cause shorter LCM life. The use of direct current to drive LCMs causes undesirable deterioration LCMs. If the logic circuit power is off, do not apply any signals to the pins. Please follow the power on/off sequences of the used controller to prevent damage on LCM. Response time will be extremely delayed if ambient temperature is below operating temperature range and on the other hand, LCD's shows dark color at higher temperature. Those phenomena do not mean malfunction of LCM. LCM will recover once being back in the specified operating temperature. Minimize the corrosion of the electrode. Corrosion of the electrodes is accelerated by water droplets, moisture condensation or a current flow in a high-humidity environment. 7/8

If the display area is pushed hard during operation, the display will become abnormal. However, it will return to normal if one power cycle is applied. Please keep the temperature within specified range for usage and storage. Polarization degradation, bubble generation or polarizer peel-off may occur with high temperature and high humidity. 1.8 Safety The liquid in LCMs is a hazardous substance. If any liquid crystal leaked out of a damaged LCM and encounter with your hands, do not lick or swallow. Wash it off immediately by using soap and water thoroughly. Use acetone or alcohol to clean up liquid leaked out of damaged LCMs. 8/8