HumiTherm Ultra Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping Mapping Unit Micro PLC Control Unit Touch Panel Touch Operation Panel PPI HumiTherm Ultra GSM Module PC Software PC Interface with 21 CFR Software 8 / 16 Channel Mapping GSM Module for SMS Alerts Password Protected Door Locking Features Ÿ 4.3" or 7" TFT, 65536 Color Touch Screen Display Ÿ Accurate Temperature & Humidity Monitoring (Universal Input : RTD Pt100,, V) Ÿ 8 (4T + 4RH) or 16 (8T + 8RH) Channel Temperature & Humidity Mapping (Optional, Add-on Module) Ÿ Precise Temperature & Humidity Control (Independent Self-Tune PID Control) Ÿ Comprehensive Alarm System (Process Deviations, Door Open, Water Level Low, Mains Fail) Ÿ Standby Sensors & Control Gadgets Interface (Optional Analog Inputs & Digital s) Ÿ Date / Time Stamped Process & Event Data Recording Ÿ Boiler (Steam Generator) Water Level Monitoring (Digital Input for Float Switch & Thermostat) Ÿ Password Protected Door Opening & Status Monitoring (Digital Input for Door Switch & Digital for Door Lock Solenoid) Ÿ Mains-Fail Detection & Automatic Change Over to Battery / Inverter
Specifications Display Viewing Area 90.04 X 52.86 mm for 4.3 & 152.4 X 91.5 mm for 7 Temperature (User Programmable) Humidity (%RH) (User Programmable) Accuracy Display Resolution Zero Offset ADC Sampling Time Common Mode Rejection Signal Conditioning Excitation Voltage 1 or 2 Analog Inputs for Main & Standby Sensor. RTD Pt100, 3 wire DC Linear : 0-20, 4-20 0-5 V, 0-10 V, 1-5 V 1 or 2 Analog Inputs for Main & Standby Sensor. DC Linear : 0-20, 4-20 0-5 V, 0-10 V, 1-5 V Temperature : 0.1 Fixed %RH : 0.1 Fixed User Adjustable over Full Range for Both Temperature & %RH 16 Bit (±32,768 Counts), Sigma-Delta (ΣΔ) 500mS (2 Samples per Second) > 100dB at 50/60 Hz Ratings 5 V @ 15 Digital Inputs 4.3 or 7 TFT Color Display with Touch Panel Resolution 480 X 272 pixels for 4.3 & 800 X 480 pixels for 7 Touch Analog Resistive Film Touch Life Greater than 1 Million Operations Analog Inputs RTD Pt100 DC Volts/Current R-C Analog Filter on Each Input : : Potential-free Contacts ± 0.25% of reading ± 1 C ± 0.25% of reading ± 1 LSD Functions Digital s Functions DI-1 : Door Open Detection DI-2 : Power Fail Detection DI-3 : Alarm ACK DI-4 : Main Water Level Detection DI-5 : Main Thermostat DI-6 : Standby Water Level Detection DI-7 : Standby Thermostat SSR Voltage Drive rated 12 VDC @ 40, Short-circuit Protected DO-1 : DO-2 : DO-3 : DO-4 : DO-5 : Alarm Main Heater Main Humidifier Main Compressor Standby Heater DO-6 : DO-7 : DO-8 : DO-9 : DO-10 : Standby Humidifier Standby Compressor Main Set Select Standby Set Select Door Lock
Alarm System Process Alarm Door Open Alarm (Optional) Water Level Alarm (Optional) Mains Fail Alarm (Optional) Alarm Acknowledge Programmable High / Low Process Alarms for Temperature & Humidity Alarm on Chamber Door Remaining Open for More than Set Time Period Alarm on Boiler Water Level Low Detection Alarm on Change-over from Mains Power to Alternate Power Source (Battery, Inverter, etc.) SSR for Remote Switching of Audio / Visual Gadget on Alarms Ÿ Rear Panel Digital Input (DI-3) for Connecting Remote Alarm Acknowledge (Mute) Button Ÿ Touch Button on HMI Main (Home) Screen Heat Control Control Parameters Humidity Control Control Parameters Compressor Control Control Strategy (Programmable) Data Recording Storage Device Record Capacity Recording Interval Self Tune PID Proportional Band, Integral Time, Derivative Time, Cycle Time SSR Drive Voltage (DO-2 & DO-5) Self Tune PID Proportional Band, Integral Time, Derivative Time, Cycle Time SSR Drive Voltage (DO-3 & DO-6) On-Off with Programmable Time Delay & Hysteresis 1. Can be Switched ON-OFF Manually 2. Based on Programmable Temperature SP Threshold. Compressor is ON for Temperature SP Below Threshold & OFF Above 3. Cool Control. Switches ON-OFF Based on Temperature PV & SP SSR Drive Voltage (DO-4 & DO-7) In-built Flash Memory 5,000 Records User Programmable (1 to 250 Minutes) Recording Data (Date/Time Stamped) Power Supply Process Values Ÿ Measured Temperature Events Ÿ Power-up, Ÿ Change in Temperature SP, Ÿ Change is Date/Time Settings, Ÿ Chamber Door Open/Close, Ÿ Mains Power Fail/Resumption Switch Mode (SMPS) Ÿ Measured Humidity Ÿ Process Value Alarm Toggle Ÿ Change in Humidity SP Ÿ Change in Recording Interval Ÿ Boiler Water Level Low Ÿ Change - over from Main to Standby Sensor Set Ÿ Change - over from Main to Standby Control Gadget Set Supply Voltage 24 VDC @ 1.1A (25 Watts) HMI + Micro PLC
Physical 4.3 HMI 7 HMI Micro PLC Control Unit 8 / 16 Channel T+RH Mapping Unit Mounting : Plug-in with Panel Mounting Clamps Overall Dimensions : 128 (W) X 102 (H) X 55 (D), mm Panel Cutout : 121 (W) X 95 (H), mm Mounting : Plug-in with Panel Mounting Clamps Overall Dimensions : 206 (W) X 136 (H) X 44 (D), mm Panel Cutout : 199 (W) X 129 (H), mm Mounting : Base / Wall Mounting Overall Dimensions : 179 (L) X 116 (W) X 77 (H), mm Mounting : Base / Wall Mounting Overall Dimensions : 210 (L) X 110 (W) X 50 (H), mm Available if Standby Control Gadget s are ordered. Available if Door Lock s is ordered. microplc Electrical Connections 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Door Lock Stby Set Select Main Set Select Compressor Humidifier Standby Heater Digital s Compressor Humidifier Main Heater Alarm Thermostat Water Level Stby Thermostat Water Level Alarm ACK Power Fail Door Open Main Digital Inputs Main Standby Humidity Temperature Humidity Temperature V V 18~32VDC 5VDC Supply Exc V V HMI RS485 Pt100 Pt100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 microplc Stability Control Mapping Module Electrical Connections 52 53 54 55 COMM PORT B B B B 28 29 30 31 MAP 1 32 B3 B2 B1 A3 A2 A1 B3 B2 B1 A3 A2 A1 B3 B2 B1 A3 A2 A1 B3 B2 B1 A3 A2 A1 PPI MAP 5 33 34 35 36 37 MAP 6 MAP 2 38 C 39 A1 A2 A3 MAP 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 40 41 42 43 MAP 7 44 RTD mv / V 45 %RH 46 47 48 mv / V 49 MAP 8 MAP 4 50 A1 A2 A3 B1 B2 B3 A1 A2 A3 B1 B2 B3 A1 A2 A3 B1 B2 B3 A1 A2 A3 B1 B2 B3 B1 B2 B3 51 84 ~ 264 VAC L N 25 26 27 SUPPLY UniMap 4 / 8 Points Mapping Module Sr. No.:
8 / 16 Channel Mapping Unit Mapping Channels Input (Independently Programmable for Each Channel) Accuracy Zero Offset ADC Sampling Time Signal Conditioning Power Supply Dimensions (mm) Mounting Connections 8 Channel (4T + 4RH) or 16 Channel (8T + 8RH) RTD Pt100, 3 wire (For Temperature Channels Only) DC Linear : 0-20, 4-20 0-50 mv, 0-200 mv 0-1.25 V, 0-5 V, 0-10 V, 1-5 V For RTD Pt100 : ± 0.25% of reading ± 1 C For DC Linear Volts / Current : ± 0.25% of reading ± 1 LSD User Adjustable over Full Range 16 Bit (±32,768 Counts), Sigma-Delta (ΣΔ) 500mS Per Channel L-C Analog Filter 85~264 VAC, 50/60 Hz, Single Phase 210 (L) X 110 (W) X 50 (D) Wall Mounting Screw, Male-Female Detachable GSM Interface (Optional Add-on Device) Controller Interface Port Frequency Band SMS Alert Events Recipients Supply Voltage RS485 Serial Quad (850/900/1800/1900 MHz) Ÿ High/Low Temperature & Humidity Alarms Ÿ Door Open Alarm Ÿ Low Boiler Water Level Alarm Ÿ Mains Failure Alarm Up to 10; User Programmable through SMS by Secured Access 10~30 VDC (24 VDC Nominal)
PC Interface with 21 CFR Compliant Software Supported Operating Systems (OS) Minimum PC Configuration Requirements PC Software Features (USFDA 21 CFR Part 11 Compliant) Windows Vista Windows 7 32 bit / 64 bit Windows 8 32 bit / 64 bit Pentium Dual Core 2.8 GHz Clock Speed 2 GB RAM 40 GB Hard Disk Ÿ Supports Multiple Chambers on Single Installation Ÿ Auto Start-up on PC Power-up Ÿ Online Display of Process Values & Stored Records in Graphical & Tabular Forms with Alarm Indications Ÿ SMS and/or Email Alerts on Alarm Conditions Ÿ Mean Kinetic Temperature (MKT) Computation Ÿ Automatic Periodic Downloading of Records Stored in Controller Ÿ Access Control According to Authority Level Ÿ User Actions with Signing & Authorization Ÿ Automatic Password Expiry Ÿ Manual & Auto Back-up Facility with Archiving Ÿ Data Log Reports with User Configurable Title, Footer & Header Ÿ Data Log Report, Alarm Log Report, History Graph & Audit Trail Report in PDF & EXCEL formats Ÿ Audit Trail History of Critical Events & User Actions ProcessPrecisionInstruments(AnISO9001:2008Company) 101,DiamondIndustrialEstate,Navghar,VasaiRoad(E),Dist.Palghar-401210,Maharashtra,India 0250-2391722/33/37/420250-2391734sales@ppiindia.net www.ppiindia.net