ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

Similar documents
MG SERIES GAS OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE M24G M36G MODELS

MT 25/40 GALLON SERIES

MT 6/10 GALLON SERIES

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

KPS-E, KLS-E AND KLT-E SERIES

MT 25/40 GALLON SERIES

Statement of Responsibilities

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

F-T, FT-P, F-L AND F-P SERIES

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Water Boilers ME10EN, ME15EN. Table of Contents

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

F-LF AND F-PF SERIES


Installation & Operating Guide

Self-Contained Electric Steam Jacketed Kettle

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Page 1 of 18. Part# /5/2013

Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

Statement of Responsibilities

Operation Manual and Parts Directory

OPERATOR'S MANUAL INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS SELF-GENERATING STEAM JACKETED COUNTER TILTING KETTLE

Sun Bandit Hybrid Water Heater Installation and Operation Solar Hybrid Energy Systems Patent(s) Pending

Wilbur Curtis Company, Inc.

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions


FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

Models: GW/R-T GW/R-2-T GW/R-3-T

INSTALLATION AND OPERATION MANUAL DIRECT STEAM COUNTER TILTING KETTLES MODELS: DC - 5 DC - 6 DC - 10 DC - 12 DC - 20

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

SuperStor Ultra Stainless Steel Storage Tank

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Installation & Operation Manual Models:

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

Wilbur Curtis Company, Inc. Service Manual WB5GT Water Boiler

Stainless steel kettle

FTM-LE SERIES SINGLE OR TWIN ELECTRIC STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

Operation Manual and Parts Directory

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

ALTAIR II CONVECTION STEAMER INSTALLATION - OPERATION - MAINTENANCE. Altair II-4 Altair II-6 Altair II-8 Altair II-10 Altair II-12 MODELS

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Electra Steam, Inc. RLP 100k 500kW Low Pressure and RHP 100kW 500kW High Pressure Steam Boiler Models. Instructions Manual

User s Information Manual

IMPORTANT SAFETY INFORMATION

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

User s Information Manual

User s Information Manual

SuperStor Glass Lined Storage Tank

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

R- RH- and RHC-Steam Boiler Models (RB-Series) Serial No and up

OPERATING MANUAL/ INSTALLATION

L A signature series TA T N E RE O, A L L A T S IN

Electrical Mini Tank Water Heater anual, and Warranty nformation

User s Information Manual

MAXUM 5 5 Gallon Box Extractor

Operation Maintenance. Mobile Oil Caddy

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

SELF-CONTAINED POWER MISTER

INSTRUCTION MANUAL. Destination Country: United Kingdom, Ireland. Gas Fired Salamander MODELS: SBE3418 & SBE3618

INSTALLATION OPERATION MAINTENANCE

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Owner s Guide Installation & Operation

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

ECO-JET CONVECTION STEAMER W/TWIN GENERATORS INSTALLATION - OPERATION - MAINTENANCE EJ-10E MODELS

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Sun Bandit Solar Hybrid Electric Water Heater Solar Hybrid Energy Systems Patent(s) Pending. Installation, Operation and Maintenance Manual IMPORTANT!

INSTALLATION AND SERVICE MANUAL

PRE INSTALLATION PROCEDURES

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Instruction Manual for HX-DX and HX-DXHP Heat Exchangers 3 / 2017

SuperStor Contender Indirect Fired Water Heater

2 Gallon Water Boiler

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Table of Contents

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

INSTALLATION AND OPERATION INSTRUCTIONS LC-D SERIES COFFEE CONCENTRATE BREWER WITH DIGITAL ELECTRONIC CONTROL CENTER

INSTALLATION & OPERATION MANUAL

OWNER S MANUAL PREMIER SERIES HIGH PERFORMANCE ELECTRIC CONVECTION OVEN. MODELS: m 3000 m 3092

Statement of Responsibilities

the Compact Kettle Instruction Book - BKE320BSS

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS Serial No.:

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Installation & Operation Manual

User s Information Manual

Transcription:

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS M24E M36E Telephone: (802) 658-6600 Fax: (802)864-0183 www.marketforge.com PN 14-0309 Rev G (11/17) 2017 - Market Forge

Your Service Agency s Address: Model Serial number Boiler installed by Installation checked by

IMPORTANT WARNING: Improper installation, adjustment, alternation, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. FOR YOUR SAFETY TABLE OF CONTENTS INSTALLATION Introduction... 2 Assembly... 3 Service Connections... 4 OPERATION Operating Instructions... 5 MAINTENANCE Cleaning the Boiler... 6 Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. The information contained in this manual is important for the proper installation, use, and maintenance of this boiler. Adherence to these procedures and instructions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference. ERRORS: Descriptive, typographic or pictorial errors are subject to correction. Specifications are subject to change without notice.

Introduction To the Kitchen Manager: 1. Read this manual carefully and in its entirety. Contact Market Forge for clarification if necessary. 2. Protect your kitchen personnel from scalding and other serious injury by providing training programs to acquaint all equipment operators with the correct and safe methods of operation. 3. Operators must be made aware of the consequences of misuse. Steam producing equipment, no matter who the manufacturer, is inherently dangerous when misused. The possibility of serious scalding always exists, the careless and/or untrained operator will be injured. 4. This equipment must be maintained according to the guidelines in this manual (see maintenance ). Lack of maintenance will lead to a potentially hazardous condition and possible liability. Operators should report any equipment malfunction immediately and steps must be taken to correct the problem before further use of the equipment is allowed. 5. Keep this manual for daily reference. THEORY OF OPERATION FOR ELECTRIC BOILER: An explanation of how the control system operates on automatic electric boilers follows: With the boiler filled with water to the proper level and the heat switch is turned ON, the contactors will pull in and permit the completion of the electric circuit to the heating elements. When the boiler builds to its set pressure, the pressure switch opens. This will open the circuit to the coil in the contactor, which in turn will drop the contacts in the contactor and shut off the electricity. As the pressure in the boiler drops the pressure control switch will again complete the circuit and build the boiler back to its set pressure. To stop all steam generation place the ON/OFF switch to the OFF position. INSTALLATION 2

Assembly RECEIVING INSTRUCTIONS: Inspect the equipment before signing the bill of lading. The equipment supplied was tested and inspected before shipment. The carrier accepted it as complete and without damage. This merchandise became your property when it was accepted by the carrier at the factory. Market Forge cannot assume responsibility for loss or damage during transit. For this reason, you should immediately inspect for visible and concealed damage or shortages before signing for shipment as follows: 1. Count the number of cartons and packages received to be sure they coincide with the bill of lading. INSTALLING LEGS: Some models are shipped without legs. A separate carton will contain the legs. If your model is received this way, be sure to follow the installation instruction sheet packed with the legs. LEVELING: In order for the boiler to drain correctly, it is important to use a level on cabinet top both left and right and front-toback. If not level, adjust feet. On compartment cookers, check the interior shelves for level condition. 2. Visually check all cartons for external damage. 3. Remove all cartons from their skids to examine equipment for concealed damage. The carton is nailed and strapped to the skid. It will be necessary to cut the straps and pry off the container. 4. After inspection, replace the cartons over the equipment on the skids to protect and secure the equipment until it is ready for installation. 5. Sign for shipment if all is in order. Note shortages, external and concealed damage, if any, on the bill of lading before accepting a partial or damaged shipment. 6. If necessary, contact the carrier immediately to file a claim. All claims must be filed by the receiver. 7. Do not remove the cartons or the skids from the cooking equipment until the unit has been transported through the building to the actual set-up location. The cartons should remain on the equipment as protection against dents and scratches. 3 INSTALLATION

Service Connections ELECTRICAL REQUIRMENTS DIMENSIONS ARE IN INCHES [MM] Volts Phase 24kW 36kW 42kW 48kW 208 (197-219) 3 66 100 117-240 (220-240) 3 58 87-116 480 (360-500) 3 29 44-58 Details of other electrical systems available upon request. 4 [102] 2.5 [64] 24 [610] M24E 36 [914] M36E SERVICE CONNECTIONS EP Power Supply - Use wire suitable for at least 90 C. Nominal amp per line wire: CW1 Cold Water - 3/8 (10mm) NPT for cold water to boiler. Cold water lines will have a maximum of 50 PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/cw2) water pressure CW2 Cold Water - 3/8 (10mm) NPT for cold water to condenser. Cold water lines will have a maximum of 50 PSI (3.5kg/cw2) and a minimum of 25 PSI (1.8 kg/cw2) water pressure. D Drain - Pipe full 2 (50mm) NPT to flush floor drain capable of receiving water flowing at a maximum rate of 5 gallons (19 liters) per minute. DO NOT MAKE SOLID CONNECTION TO FLOOR DRAIN. ST Steam Take-off - Connection for operation of adjacent steam powered equipment. The only available space to supply utilities to the electric boiler is the 6 (152mm) space between the floor and the cabinet. 12.5 [318] 10.5 [267] 10.5 [267] 3 [76] 5 [127] D CW1 ST CW2 ST EP 6 [152] 6 [152] 33 [838] PVC & CPVC PIPE ARE NOT ACCEPTABLE MATERIALS FOR DRAINS. DRAIN LINE INSTALLATION: The drain port of the unit is marked with a colored tag and is located at the lower rear left side of the boiler as viewed from the front. This exhaust line may be left open if the boiler has to be situated in a tiled floor depression or a tiled curb section that is equipped with drain facilities. If this is not the case, then a 2 (51mm) NPT drain line must be connected to divert the exhaust to the floor drain. If it is necessary to use more than two elbows, increase the size of the waste line accordingly. The drain piping must consist of temperature resistant material, greater than 160 F, and be of adequate diameter not to cause flow restriction. Improper materials may deform and cause restrictions, thus affecting performance. 22 [559] CW1 CW2 D EP 28 [711] 6 [152] WARNING: DO NOT UNDER ANY CIRCUMSTANCE CONNECT THE EXHAUST DRAIN LINE DIRECTLY TO A SEWER LINE. Figure 1 CAUTION: REMOTE KETTLE OPERATION If this boiler is feeding a remote kettle that will be more than 5 feet (1.5 meters) away, consult factory before ordering. WATER SUPPLY Good quality water feed is the responsibility of the owner. Water quality must be within the following general guidelines. TDS: 40-125 ppm Hardness: 35-100 ppm Chlorine: <0.2 ppm Silica: <13 ppm Chlorides: <25 ppm Chloramine: <0.2 ppm ph: 7.0-8.5 The best defense against poor water quality is a water treatment system designed to meet your water quality conditions. INSTALLATION 4

Operating Instructions OPERATING INSTRUCTIONS FOR STEAM BOILERS Be sure to check that 1. ON-OFF switch is in the off position. 2. Water supply valve is open. 3. Electricity is connected to all units. 4. Proceed with the daily operating procedures. DAILY OPERATING PROCEDURE: 1. Press ON-OFF switch from off to on. 2. Wait 5-10 minutes for water to fill in steam boiler (gauge glass should be 2/3 full) to ON. When the Low Water light goes off, the Green indicator light will come ON. (This is necessary to manually reset the unit). 4. Wait 10-15 minutes to allow the boiler to build pressure to the desired operating level of 9-11 PSI PSI. DAILY SHUT DOWN AND CLEANING: 1. STEP 1 - Press water switch off. This will drain the steam boiler. 2. STEP 2 - After steam boiler has completely drained repeat steps 1 & 2 (water to remain in steam boiler until next daily use). 3. Press HEAT switch from ON to OFF and release back Figure 2 5 OPERATION

Cleaning the Boiler Market Forge recommends that the boiler be cleaned periodically due to impurities introduced through the water supply. All water supplies contain some mineral deposits and impurities; the degree varies with geographic location. Market Forge is recommending a cleaning schedule that will keep your equipment in proper, safe working order where water supplies are relatively pure. Because no water supply can be accurately compared with that of another, this section should not be regarded as fool proof. A stepped-up, more frequent cleaning schedule may be required when excessive impurities exist. The Cleaning schedule should be performed two or more times per year as governed by the local water conditions. Market Forge recommends the use of its cathodic descaler to protect the inner boiler walls and components against rust, scale and lime deposits. The normal effectiveness of a descaler is one year. The schedule for changing the cathodic descaler may be timed to the cleaning schedule or accelerated as noted above. Market Forge qualified service agencies are available to establish a suitable schedule for TOTAL CONCEPT cleaning and descaler replacement. CLEANING INSTRUCTIONS 1. Move the heat and power switch to their OFF positions. This will allow the boiler to empty. WARNING: DISCONNECT THE MAIN POWER SUPPLY. 2. Remove the pressure switch manifold assembly at the plumbing union (A) in Figure 3 and move it safely out of the way. 3. Remove the front cover to the contactor box (B) in Figure 3 and move it out of the way. A B Figure 3 MAINTENANCE 6

Cleaning the Boiler C Figure 4 4. Remove the front cover with elements (C) Figure 4 as follows: Using a 1/4 socket head wrench, back off the (9) Hex-Nuts, counterclockwise. 5. Clean rust, scale and lime deposits from the inside of the boiler with a wire brush. 6. Remove all debris; flush out with clean water through the opening created by removing the front cover with elements and drain. 7. Remove the heating elements from the front cover plate. Take care not to damage the heating elements - brush lightly. 8. Clean the front cover plate and element flanges with a wire brush and wash. Be sure the areas that will come in contact with the gaskets and are clean and smooth. To protect against further scale and corrosion remove the old cathodic anode. Install a new Market Forge zinc anode. REPLACEMENT PARTS NEEDED TO COMPLETE THESE INSTRUCTIONS Description Part No. Qty Front Cover Gasket 98-1673 1 Set of Rubber & Brass Washers 90-0039 1 Heating Element Gasket 81-8660 3 Market Forge Zinc Anode 08-0034 1 Weekly Cleaning In addition to the daily cleaning it is necessary to clean the air intakes on a weekly basis. Air intakes provide necessary cooling air to the internal components. They are generally located on the rear and sides of the equipment. 7 MAINTENANCE

Cleaning the Boiler APPLYING TOTAL CONCEPT DESCALER Total Concept is designed to be used with water between 160 F to 200 F. Preheating is required on the boiler to raise the water temperature to the acceptable range. (160 F to 200 F). Total Concept is a NSF listed nonfood product. This is a liquid acid (nonmuriatic) product that works without fumes, odors, and hazards associated with other harsh chemicals. Product is also USDA approved. BOILER TREATMENT CLEANING INSTRUCTIONS After determining proper location for cleaner/descaler to be added: Read complete instructions thoroughly; including all warning and cautionary statements. 1. Energize boiler and fill to operating level. Figure 8 4. Remove the shipping cap, replace it with the pouring cap. Cut the tip of the pouring cap at the first notch to a 45 angle. Figure 5 2. Energize heating circuit to pre-heat unit. Figure 9 5. Install the tubing firmly over the tip of the pouring cap. Figure 6 3. AUTOMATIC - After unit is pre-heated, cycle the power switch to the OFF position then immediately back to the ON position Figure 10 6. Energize compartment to release steam pressure in boiler to 0 PSI before removing pipe plug. Figure 7 MAINTENANCE 8

Cleaning the Boiler 7. Remove the plug from the access port on the steam header pipe inside cabinet doors. 10. When empty, refill the container with hot tap water and add to boiler for cleaning. Repeat twice. This additional 2 gallons of water will cause the low water probe to be immersed in cleaner/descaler solution. Replace access plug. 11. After rinsing the container, place tubing inside the bottle, cover with shipping cap, dispose of properly. DO NOT REUSE CONTAINER. 12. DO NOT ENERGIZE HEATERS. Allow 2 hours for cleaning. 13. After time has elapsed, drain the boiler. 14. Refill the boiler and drain. Repeat this step twice. Figure 11 CAUTION: HEADER PIPE & ACCESS PLUG ARE HOT. 8. Feed the tubing through the access port in the boiler compartment. NOTE: A minimum of 12 must be inserted. 15. Bring the boiler to temperature and cycle steam to the cooker compartment to purge cleaner/descaler from the steam supply lines. Repeat this step twice. 16. Boiler is now ready for use. Figure 12 9. Tilt the container, pour the contents into the unit. Figure 13 9 MAINTENANCE