User Manual. Power Distribution Unit. Version: 1.0

Similar documents
Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

User Operation Manual

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Fire control panels FC360

RTD TEMPERATURE SENSING SYSTEM

DGC-1000 DIGITAL GENSET CONTROLLER

Refrigerated Incubator Model and Operating Instructions

Product Data Sheet. Remote Terminals. Features:

Instruction Manual for Electric Ovens OO757X OO986X

15R HARDWARE INSTALLATION GUIDE

FCCP 200: Fume-cupboard indicator and monitor

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Modbus RTU RS485 Manual

Line Isolation Monitor (LIM) LIM2000plus

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

PDA20DX Air Purifying Dehumdifier Manual

Dry Bath Heating Systems

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

LORAIN CIP 4890/48120 DC Power System

Fire control panels FC726 FC726-XA

LORAIN CSP DC Power System

CSP-204 CSP-208 CSP-104 CSP-108

SIMPLEX WEATHERPROOF CONTROL PANELS

EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E

CO2 & Oxygen Monitor Operating Instructions Model: RAD

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Operation Manual. (Version 1.5.1)

Operating Instructions

Dohse Aquaristik GmbH & Co. KG

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Galaxy Pulsar Plus Digital Battery Plant Controller

ECO PDU PE7214/PE7216/PE7324/PE7328

Operation Manual (Version 1.5.1)

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Commercial in Confidence

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

APC BC300 Series 40kW 208/450/480V User Guide

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

B900/ BME900/ SKOPE Gen2: Two Door Chiller

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

RAYCHEM NGC-30 COMPONENTS

MTRA-FSP Level Control Relay. Installation & Operation Manual

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

OPERATION / INSTALLATION

Rack Mount Series Installation Guide

ZXSe Range Data Sheet

FDM Series. User Manual. SKOPE Food Display Cabinet Integral models: FDM900i/1200i/1500i. Model FDM1200i

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Motion Sensor Oscillating Heater with Digital Control

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Isolated Power Systems Equipment

Operations Manual. Part Number: For Research Use Only

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

CALTECH Pasadena, CA

System 57. An advanced world of intelligent gas detection system management

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Follett Performance Plus

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

End To End Optical Beam Smoke Detector. Additional Information

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Declaration of Conformity

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

CHECKFIRE 210 Detection and Actuation System

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Vocia VACIE. Reference Guide

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

VACIE REFERENCE GUIDE REVISION 1.2.6

DIESEL Engine Fire Pump Controllers Features

V80-H Multistage Pump Instruction Manual

Remote alarm indicator and test combination MK2430

Operating Instructions

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

CO2 Monitor Operating Instructions

Infrared Thermometer

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

RE-PR3-E-27 3-Phase Panel Mount 27kW

Installation, Operating and Maintenance Manual

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Analog Room Pressure Monitor RPC Series

Multi-Gas-Controller MGC2

Across-the-Line SERIES MP300 Combined Manual and Automatic

Variable Frequency Drive SERIES MP800 VFD

Weather System Pro Model: BAR629HG / BAR629HGU User Manual

Entero Voice Alarm system.

EXTINGUISHING AGENT RELEASE MODULE

Transcription:

User Manual Power Distribution Unit Version: 1.0

Table Of Contents 1. Introduction... 1 1-1 Package Contents... 1 1-2 Safety... 1 1-3 Disposing of PDU... 1 1-4 Function... 1 1-5 Overview... 2 2. Installation... 3 2-1 Rack Mounting... 3 2-2 Connections... 3 3 Operation & Display... 4 3-1 Panel Overview... 4 3-2 Operation... 4 4. Technical Specification... 10

1. Introduction 1-1 Package Contents PDU x 1 User Manual x 1 USB cable x 1 IEC-SCHUCKO 16A cable 1-2 Safety The PDU must be connected to earth while in use. Do not use extension cords or adapters with this PDU. Ensure the power cord and sockets are in good condition. To reduce the risk of fire or electrical shock, PDU installation has to be in a temperature and humidity controlled indoor environment. Ambient temperature must not exceed 50 C. The PDU is not intended for outdoor use. 1-3 Disposing of PDU The PDU contains internal components that are considered toxic or hazardous waste such as electronic circuit boards. For proper disposal, contact your local recycling/reuse or hazardous waste center. 1-4 Function The PDU is designed to distribute AC power from a single source to 8 outputs with advanced load monitoring and local or remote ON/ switching control of individual outlets. 1

1-5 Overview FRONT VIEW REAR VIEW switch USB communication port RS232 communication port SELECT button: to toggle the different status screens in LCD display ON/ button: to turn on or off the outputs Fault indicator MUTE/FUNCTION button: to silence the buzzer Expansion slot for communication boards Output IEC 10A sockets 16A plug LCD display Mains indicator 2

2. Installation 2-1 Rack Mounting Following figure shows how to install the PDU module in a 19-inch bay (with a depth of 600mm) at the desired height in the cabinet uprights. Secure the device adequately to cabinet with four screws. 2-2 Connections For connecting the PDU, plug the input to the mains or to the UPS depending on user s requirements. Plug the equipment to the outputs. 3

3 Operation & Display 3-1 Panel Overview 1. On/Off button 2. Select button 3. LCD display: for detailed LCD operation, please check section 3-2. 4. Power indicator (Yellow) 5. Fault indicator (Red) 6. Mute/Function button On the LCD display, it will show the following information: voltage current Output current for each output socket Output watt for each output socket Output watt-hour for each output socket Numerical pug icon to represent each output socket icon on = output on icon off = output off icon blinking = output overload (alarm overload or output shutdown due to overload) Fault code (please check section 3-2-4 for detailed codes) 3-2 Operation The LCD display allows you to view the status of each output (ON / ), input voltage, input current, the current on each output and any alarm codes present. Eight digital numbers displayed on the bottom of LCD to represent the eight output sockets. If the numerical icon is on, the represented output socket is powered on. If the numerical icon is off, the represented output socket is powered off. If the numerical icon is blinking, the represented output socket is overload. 4

3-2-1 SELECT Button The SELECT button allows you to scroll through different status screen. The LCD displayed information will be switched in turns by pressing SELECT button. The displayed information is switched as below order: Total input voltage/input current, input voltage/output current for each active numerical plug and fault codes. Information LCD Display Current Output 1 Current Output 2 Current Output 3 Current Output 4 Current Output 5 Current 5

Output 6 Current Output 7 Current Output 8 Current Alarm code F05: overload alarm on output 5. Current available outputs are plug 1, 5 and 8. Fault codes will be displayed in turns automatically if more than two faults or lock alarms occur. (Refer 3-2-4. Alarm code for the details) Back to the top 3-2-2 ON/ Button The ON/ button allows you to switch on or off output sockets one by one. Turn on selected output socket To switch on a numerical output socket, you have to switch to specific plug number shown on left corner by keep pressing SELET button. Then, press ON/ button (1 to 2 sec) until the represented number is displayed on the bottom of LCD screen. Turn off selected output socket To switch off a numerical output socket, you have to switch to specific plug number shown on left corner by keep pressing SELET button. Then, press ON/ button (1 to 2 sec) until the represented number is faded on the bottom of LCD screen. The ON/ button is no function while it s shown input current or the Alarm code in LCD display. 6

3-2-3 Mute/Function Button Two functions by pressing Mute/Function button. Mute function by pressing and hold the button for at least 3 seconds. Function button by quick press the button Mute Operation When the buzzer is sounding due to alarms, the buzzer can be mute by pressing this button. After buzzer is mute, if warning situation remains, it s possible to press this button to have buzzer sound again. If one or more alarms occur after buzzer has been mute, the buzzer will sound again. Function Operation It s to switch displayed information on specific output. The displayed information is output current, output wattage and output wattage-hour in order. You may switch to specific output by pressing SELECT button. When requested plug number is shown on left digital area, quick press FUNCTION button to switch displayed information. Information LCD Display Output 1 Current Output 1 Wattage Output 1 Wattage-Hour Back to Output 1 Current screen 7

3-2-4 Alarm Code/LED/Buzzer CODE DESCRIPTION Fault LED MAINS LED A01 Low input voltage ON A02 High input voltage ON S01 S02 S03 S04 S05 S06 S07 S08 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 F01 Overload alarm on Output 1 ON F02 Overload alarm on Output 2 ON F03 Overload alarm on Output 3 ON F04 Overload alarm on Output 4 ON F05 Overload alarm on Output 5 ON F06 Overload alarm on Output 6 ON F07 Overload alarm on Output 7 ON F08 Overload alarm on Output 8 ON F09 Low input current ON Buzzer 8

F10 High input current ON F11 Power Fail on Auxiliary 1 ON ON F12 Power Fail on Auxiliary 2 ON ON L01 Lock for overload on Output 1 ON ON L02 Lock for overload on Output 2 ON ON L03 Lock for overload on Output 3 ON ON L04 Lock for overload on Output 4 ON ON L05 Lock for overload on Output 5 ON ON L06 Lock for overload on Output 6 ON ON L07 Lock for overload on Output 7 ON ON L08 Lock for overload on Output 8 ON ON L13 High input voltage ON ON NOTE: The output lock due to overload is permanent and only can be reset by switching on the locked output again. Please simply press the ON/ button to turn on the output. 9

4. Technical Specification Plug IEC C20 16A 250V Cord Entry Rear feed Maximum Current 16A Rated Current 16A Nominal 220V/230V/240V Rated 184 300V Frequency 50Hz/60Hz Power Capacity 3.68KVA at 230V Overload Protection 16A Breaker Output Nominal Output 220V/230V/240V Rated Output 184 300V Output Connections (8) IEC C13 Output Current Accuracy +/- 0.1A Physical Dimensions (D x W x H) 250 x 430 x 44 (mm) Color Black Weight (Kg) 3.5 Environmental Operation Environment 0 50 Operation Relative 0 90% No condensing Humidity Altitude <1000m Conformance EN 55022 Class B EN 61000-3-2 EMC EN 61000-3-3 EN 55024 Safety EN60950-1 10