Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

Similar documents
100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1

ATTACHMENT B SECTION SPECIAL CONDITIONS

Call us today! (800)

Call us today! (800)

Call us today! (800)

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

INVITATION FOR BID T CHILLER, AHU, AND FCU S FOR PATY HALL

SECTION ROTARY-SCREW WATER CHILLERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

C13-Series Engineering Guide

.2 Section Waste Management and Disposal.

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Commercial High-Efficiency Condensing Units

RECORD SUBMITTAL COVER SHEET

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

30GN FLOTRONIC II AIR-COOLED CHILLERS

VertiCool Aurora Engineering Guide

30GT FLOTRONIC AIR-COOLED CHILLERS

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

PACKAGED AIR COOLED Product Data Catalog

Air-Cooled Global Chiller

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

VariCool VAV Engineering Guide

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

PACKAGE AIR CONDITIONER

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Air-Cooled Condensing Units with Compact Screw Compressors

Installation Instructions

Cutting Edge Compressor Technology

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

NEW CHILLER SCHEDULE

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

General Description. Operation

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

PAJ3. Product Specifications

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Roof Top Packaged Unit (RTU-1) Specification

Advance Release September 2009

Air-Cooled Modular Split Systems. Product Data Catalog

SECTION CENTRIFUGAL WATER CHILLERS

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

NFZP Variable Refrigerant Flow Guide Specification

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

Indoor Air Handlers with Compressors MVS and MVW

R4H4. Product Specifications

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

WCH5**4. Product Specifications

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

N4H4. Product Specifications

2 shp 13 lc 1 36 t - 1 a

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

TECHNICAL SPECIFICATIONS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Installation, Start-Up and Service Instructions

SECTION AIR COOLED WATER CHILLERS

User s Information and Installation Instructions

Transcription:

Submittal Prepared For: All Bidders Sold To: Date: September 04, 2012 Customer P.O. Number: Customer Project Number: Job Number: Job Name: DCS 12473 80 Ton Chiller Dept of Wildlife 1801 N Lincoln OKLAHOMA CITY, OK 73105 Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Air-Cooled Scroll The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Andy Donehue Trane 305 Hudiburg Circle Oklahoma City, OK 73108-1008 Phone: (405) 787-2237 Cell: Fax: (405) 787-0752 J:\JOBS\61\50946\4\DCS 12473 80 Ton Chiller Dept of Wildlife Submittal.doc

Table Of Contents Product Summary...1 Air-Cooled Scroll (Item A1) Tag Data... 3 Product Data... 3 Performance Data... 4 Mechanical Specifications... 5 Unit Dimensions... 7 Weight, Clearance & Rigging Diagram... 13 Accessory... 16 Field Wiring... 19

Tag Data - Air-Cooled Scroll (Qty: 1) Item Tag(s) Qty Description Model Number A1 CGAM-1 1 Air-Cooled Chiller, Scroll CGAM080F2*02AXD2A1A1A1AXXA1D1AXXXXXX Compressors XB1A3A1D1X-L-X Product Data - Air-Cooled Scroll Air-Cooled Scroll Packaged Chiller 80 nominal tons 60 hertz 460 volt 3 phases High efficiency/performance Full factory refrigerant charge (HFC-410A) With freeze protection (External T-STAT control) Refrigerant isolation valves (discharge valve) UL listed to US and Canadian safety std ASHRAE 90.1 all versions compliant AHRI certified Flow switch set point 60 Startup allowance Std cooling (42 to 65F/5.5 to 18C) Grooved pipe connection Factory insulation - all cold parts Performance based on water Wide ambient (0 to 125F/-18 to 52C) Lanced aluminum fins Across the line starter/direct on line Single point power connection Circuit breaker-high fault rated control panel Enclosure type UL 1995 rated for outdoor applications High A short circuit rating Elastomeric isolators With water strainer factory installed Super quiet Architectural louvered panels Equipment Submittal Page 3 of 20

Performance Data - Air-Cooled Scroll Tags CGAM-1 Capacity (tons) 75.80 Unit power input (kw) 93.90 Full load efficiency (EER) 9.7 NPLV (EER) 15.8 IPLV (EER) 15.6 Sound power level (dba) 92 Sound pressure level (dba) 65 Refrigerant R410A Refrigerant charge circuit 1 (lb) 74.0 Refrigerant charge circuit 2 (lb) 74.0 Oil charge circuit 1 (gal) 3.54 Oil charge circuit 2 (gal) 3.54 Evap entering temp (F) 54.00 Evap leaving temp (F) 44.00 Evap flow rate (gpm) 181.20 Min evap flow rate (gpm) 114.70 Min flow PD evap+strainer (ft H2O) 6.50 Max evap flow rate (gpm) 275.30 Max flow PD evap+strainer (ft H2O) 34.20 Evap fluid freeze point (F) 32.00 Evap press drop (ft H2O) 13.00 Total PD evap+strainer (ft H2O) 15.40 Evap fouling factor (hr-sq ft-deg F/Btu) 0.00010 Saturated evap temp circuit 1 (F) 37.70 Saturated evap temp circuit 2 (F) 37.70 Ambient air temperature (F) 99.00 Elevation (ft) 1280.00 Saturated cond temp circuit 1 (F) 126.50 Saturated cond temp circuit 2 (F) 126.60 Compressor power input (kw) 86.70 RLA - compressor 1A (A) 33.00 LRA - compressor 1A (A) 215.00 RLA - compressor 1B (A) 33.00 LRA - compressor 1B (A) 215.00 RLA - compressor 2A (A) 33.00 LRA - compressor 2A (A) 215.00 RLA - compressor 2B (A) 33.00 LRA - compressor 2B (A) 215.00 Total airflow (cfm) 56844 Number of fans ( ) 6 Fan motor power (kw) 6.80 Total fan FLA (A) 20.20 Single point power MCA (A) 162.20 Single point power MOP (A) 175.00 Short circuit current rating (A) 65000.00 Number of compressors ( ) 4 Number of circuits ( ) 2 Capacity steps ( ) 4 Shipping weight (lb) 5607.3 Operating weight (lb) 5692.2 Length (in) 143.100 Width (in) 89.000 Height (in) 92.400 Equipment Submittal Page 4 of 20

Mechanical Specifications - Air-Cooled Scroll General Units are constructed of a galvanized steel frame with galvanized steel panels and access doors. Component surfaces are finished with a powder-coated paint. All paint meets the requirement for outdoor equipment of the U.S. Navy and other Federal Government Agencies. This paint finish is durable enough to withstand a 1000-consecutive-hour salt spay application in accordance with standard ASTMB117. Each unit ships with full operating charges of refrigerant and oil. Compressor and Motor The unit is equipped with four hermetic, direct-drive, 3600 rpm 60 Hz suction gas-cooled scroll compressors. The simple design has only three major moving parts and a completely enclosed compression chamber which leads to increased efficiency. Overload protection is internal to the compressors. The compressor includes: centrifugal oil pump, oil level sight glass and oil charging valve. Each compressor will have compressor heaters installed and properly sized to minimize the amount of liquid refrigerant present in the oil sump during off cycles. Unit-Mounted Starter The control panel is designed per UL 1995. The starter is in an across-the-line configuration, factory-mounted and fully pre-wired to the compressor motor and control panel. Typically, Trane scroll compressors are up to full speed in one second when started across-the-line. A factory-installed, factory-wired 820 VA control power transformer provides all unit control power (120 Vac secondary) and Trane CH530 module power (24 Vac secondary). A molded case high interrupting capacity circuit breaker, factory pre-wired with terminal block power connections and equipped with a lockable external operator handle, is available to disconnect the chiller from main power. Power Connection Power connections include main three-phase power and one separate 120V, 15 amp customer provided single phase power connection is required to power the heaters (if used for freeze protection). Short circuit current rating of 65 ka is provided. Evaporator Braze plate evaporator is made of stainless steel with copper as the braze material. It is designed to withstand a refrigerant side working pressure of 430 psig (29.6 bars) and a waterside working pressure of 150 psig (10.5 bars). Evaporator is tested at 1.1 times maximum allowable refrigerant side working pressure and 1.5 times maximum allowable water side working pressure. It has one water pass. Immersion heaters protect the evaporator to an ambient of -20 F (-29 C). A water strainer and a flow switch are factory installed. Condenser Air-cooled condenser coils have lanced aluminum fins mechanically bonded to internally-finned copper tubing. The condenser coil has an integral subcooling circuit. The maximum allowable working pressure of the condenser is 650 psig (44.8 bars). Condensers are factory proof and leak tested at 715 psig (49.3 bars). Direct-drive vertical discharge condenser fans are balanced and individually protected. Three-phase condenser fan motors with permanently lubricated ball bearings and external thermal overload protection are provided. A variable speed drive on the first fan of each circuit allows the unit to start and operate with ambient temperatures between 0.0 F and 125.0 F. Refrigerant Circuits The unit has dual refrigerant circuits. Each refrigerant circuit has Trane scroll compressors piped in parallel with a passive oil management system. A passive oil management system maintains proper oil levels within compressors and has no moving parts. Each refrigerant circuit includes filter drier, electronic expansion valve, liquid line and discharge service valves. Capacity modulation is achieved by turning compressors on and off. The unit has four capacity stages. Unit Controls The microprocessor-based control panel is factory-installed and factory-tested. The control system is powered by a pre-wired control power transformer, and will turn on and off compressors to meet the load. Microprocessor-based Equipment Submittal Page 5 of 20

chilled water reset based on return water is standard. The unit comes with a factory installed flow switch. The Trane CH530 microprocessor automatically acts to prevent unit shutdown due to abnormal operating conditions associated with low evaporator refrigerant temperature and high condensing temperature. If an abnormal operating condition continues and the protective limit is reached, the machine will shut down. The panel includes machine protection for the following conditions: low evaporator refrigerant temperature and pressure, high condenser refrigerant pressure, critical sensor or detection circuit faults, lost communication between modules, phase loss, phase reversal, over temperature protection, external and local emergency stop, and loss of evaporator water flow. When a fault is detected, the control system conducts more than 100 diagnostic checks and displays results. The display will identify the fault, indicate date, time, and operating mode at time of occurrence, and provide type of reset required and a help message. Data contained in available reports includes: water and air temperatures, refrigerant pressures and temperatures, flow switch status, EXV position, and compressor starts and run-time. All necessary settings and setpoints are programmed into the microprocessor-based controller via the operator interface. The controller is capable of receiving signals simultaneously from a variety of control sources, in any combination, and priority order of control sources can be programmed. Architectural Louvered Panels Louvered panels cover the complete condensing coil and service area beneath the condenser. Isolators Molded elastomeric isolators, sized to reduce vibration transmission to the supporting structure when the unit is installed, ship with the chiller. Equipment Submittal Page 6 of 20

Unit Dimensions - Air-Cooled Scroll INLET/OUTLET WATER CONNECTION SIZE 4" (100mm) BRAZE PLATE WATER VOLUME/STORAGE 7.0 GAL (26.5 LITERS) TOP VIEW ISOMETRIC VIEW FRONT VIEW RIGHT SIDE VIEW BACK VIEW Equipment Submittal Page 7 of 20

Unit Dimensions - Air-Cooled Scroll 29 9/16" 89 3/16" 139 13/16" LIFTING LOCATION 4 PLACES 143 1/16" RIGHT SIDE VIEW Equipment Submittal Page 8 of 20

Unit Dimensions - Air-Cooled Scroll COMPRESSORS COMPRESSORS BRAZE PLATE TOP VIEW CONDENSER, CONTROL PANEL AND VSD (WHEN ORDERED) REMOVED FOR CLARITY 5 7/16" INLET \ OUTLET WATER CONNECTION UNIT CONTROL PANEL THIS END OF UNIT Equipment Submittal Page 9 of 20

Unit Dimensions - Air-Cooled Scroll UNIT CONTROL PANEL 88 7/8" 88 3/16" FRONT VIEW LOUVERED PANELS NOT SHOWN OVER CONTROL PANEL FOR CLARITY 8 9/16" 84" 92 5/8" Equipment Submittal Page 10 of 20

Unit Dimensions - Air-Cooled Scroll BACK VIEW 11 1/2" 31 1/16" 7 7/8" INLET WATER CONNECTION OUTLET WATER CONNECTION Equipment Submittal Page 11 of 20

Unit Dimensions - Air-Cooled Scroll ISOMETRIC VIEW LOUVERED PANELS NOT SHOWN OVER CONTROL PANEL FOR CLARITY Equipment Submittal Page 12 of 20

Weight, Clearance & Rigging Diagram - Air-Cooled Scroll UNIT CENTER OF GRAVITY LIFTING WEIGHTS W1 W2 W3 W4 SHIPPING WEIGHT 1811.3 lb 1968.7 lb 832.0 lb 904.3 lb 5607.3 lb CG CG 46.610 in 37.891 in W1 - NEAR SIDE W2 - FAR SIDE 59.484 in W3 - NEAR SIDE W4 - FAR SIDE FRONT VIEW SIDE VIEW CONTROL PANEL END Equipment Submittal Page 13 of 20

Weight, Clearance & Rigging Diagram - Air-Cooled Scroll 47 1/4" FOR OBSTRUCTIONS OR MULTIPLE UNITS, REFER TO THE CLOSE SPACING BULLETIN. UNIT CLEARANCE NO OBSTRUCTIONS ABOVE THE CONDENSER NO OBSTRUCTIONS RECOMMENDED. Area Required for unit operation, maintenance, and access panel. MORE CLEARANCE MAY BE NEEDED FOR AIRFLOW DEPENDING UPON THE INSTALLATION. 39 3/8" 39 3/8" 39 3/8" WORKING CLEARANCE PER NATIONAL ELECTRIC CODE ARTICLE 110-26. TOP VIEW Equipment Submittal Page 14 of 20

Weight, Clearance & Rigging Diagram - Air-Cooled Scroll LIFTING A UNIT WITH EQUAL LENGTH STRAPS WILL NOT PRODUCE A LEVEL UNIT DURING THE LIFT BECAUSE THE CG WILL NOT BE AT THE MIDPOINT BETWEEN THE BASE LIFTING HOLES. THE FOLLOWING ADJUSTMENTS MUST BE MADE TO PRODUCE A LEVEL LIFT: - SINGLE SPREADER BAR LIFTING METHOD IF THE UNIT CG IS CLOSER TO THE CONTROL PANEL, THE STRAPS ON THE CONTROL PANEL SIDE OF THE SPREADER BAR MUST BE ADJUSTED TO BE SHORTER THAN THOSE ON THE OPPOSITE SIDE OF THE SPREADER BAR, ALLOWING THE SPREADER BAR TO MOVE TOWARD THE CONTROL PANEL AND OVER THE UNIT CG. SEVERAL ADJUSTMENTS OF THE STRAP LENGTH MAY BE REQUIRED TO PRODUCE A LEVEL UNIT DURING LIFT. - H-TYPE SPREADER BAR LIFTING METHOD IF THE STRAPS FROM THE H BAR TO THE UNIT BASE ARE THE SAME LENGTH, THE CRANE LIFTING POINT ON THE CENTER WEB OF THE H BAR MUST BE ADJUSTED TO PRODUCE A LEVEL UNIT LIFT. WARNING IMPROPER LIFTING AND MOVING! USE SPREADER BAR AS SHOWN IN DIAGRAM. REFER TO INSTALLATION MANUAL OR NAMEPLATE FOR UNIT WEIGHT. REFER TO INSTALLATION INSTRUCTIONS LOCATED INSIDE CONTROL PANEL FOR FURTHER RIGGING INFORMATION. OTHER LIFTING ARRANGEMENTS COULD RESULT IN DEATH, SERIOUS INJURY OR EQUIPMENT DAMAGE. UNIT RIGGING ISOMETRIC VIEW 29 9/16" 89 3/16" Equipment Submittal Page 15 of 20

Accessory - Air-Cooled Scroll CUSTOMER WIRE SELECTION TABLE SHORT CIRCUIT RATING POWER WIRE CONNECTION TO CIRCUIT BREAKER (1Q1) 65kA UNIT SIZE UNIT EFF VOLTAGE CIR 1 & 2 (SINGLE POINT POWER) LUG WIRE SIZE RANGE (PER PHASE) 080 HIGH 460 (1 MAX Conductor per phase) 3/0-350MCM CUSTOMER CONTROL WIRING 10 KNOCKOUTS 6 1/8" 4 3/4" 1 15/16" LEFT END VIEW ISOMETRIC VIEW 3 3/8" 4 3/4" 6 1/8" 7 1/2" 32" CUSTOMER POWER WIRING CUSTOMER POWER WIRING (OPTION) 4 3/4" 88 3/4" 2 13/16" FRONT VIEW 6 15/16" RIGHT END VIEW 7" Equipment Submittal Page 16 of 20

Accessory - Air-Cooled Scroll UNIT SIZE MOUNTING LOCATIONS & POINT LOAD WEIGHTS 1 2 3 4 5 6 7 8 080 1434.8 lb 1662.1 lb 774.3 lb 885.5 lb 395.7 lb 448.8 lb N/A N/A 5692.2 lb TOTAL OPERATING WEIGHT MOUNTING HOLE DIAMETER 19mm DIMENSIONS ARE REFERENCED FROM THE END AND SIDE OF THE UNIT BASE 30 3/16" CONTROL PANEL 1 2 83 11/16" 123 7/8" 3 4 5 6 1 1/2" TOP VIEW Equipment Submittal Page 17 of 20

Accessory - Air-Cooled Scroll UNIT SIZE 080 1 2 3 4 5 6 7 8 RDP-4 BRICK RED RDP-4 LIME RDP-4 BRICK RED MOUNTING LOCATIONS AND ISOLATOR NUMBER RDP-4 BRICK RED RDP-3 CHARCOAL RDP-3 CHARCOAL N/A N/A 2 4 6 8 CONTROL PANEL 1 3 5 7 SEE ISOLATOR POINT LOADS FOR DETAILED INFORMATION ON ISOLATOR LOCATIONS. RDP-3 ISOLATORS RDP-4 ISOLATORS 9/16" DIA 2 HOLES 9/16" DIA 2 HOLES 3 3/8" 4 5/8" 4 1/8" 5" 5 1/2" 6 1/4" 1/2" DIA 1/2" DIA 3" 2 1/2" 1 1/8" 1 5/8" 2 7/8" 1/4" 3/8" 2 3/4" Equipment Submittal Page 18 of 20

Field Wiring - Air-Cooled Scroll INSET "A" 1 1Q2 A B C L1 L2 L3 1A13 1A12 15 1A9 DUAL LOW VOLTAGE DUAL LOW VOLTAGE DUAL RELAY OUTPUT BINARY INPUT BINARY INPUT EVAP WATER PUMP EMERGENY STOP/ CHILLED WATER PUMP RELAYS RUN SIGNAL AUTO STOP FAULT INPUT J2 J2 J2 4 3 2 1X4-32 PUMP STARTER COILS 41 40 41 40 40 41 H 17 N 21 3 540 1X4-31 1X4-30 539 536 1X4-29 535 AUTO STOP PUMP 2 PUMP 1 PUMP 1 PUMP 2 6Q1 L3 18 L2 B L1 21 CUSTOMER SUPPLIED PUMP PUMP CONTROL 6M1 6M2 NOTICE TRANE PUMP CONTROL MUST BE USED TO PROVIDE PUMP CONTROL. CHILLED WATER PUMP MUST BE CONTROLLED BY THE CHILLER OUTPUT. FAILURE TO COMPLY WITH THIS REQUIREMENT. COULD RESULT IN DAMAGE TO THE UNIT. 25A 26A INSET "B" H1 H2 H3 200V 60HZ 460V 60HZ 1T1 115V 27V OR 110V X1 X2 X3 X4 400V 50HZ UNITIS FACTORY WIRED AS SHOWN, RECONNECTWIRE 26A TO TERMINALS H2 ORH4 INSET "B" 2 FOR 380V 50HZ OR 415V 50HZ POWER SUPPLIES. 25A H1 380V 60HZ 220V 50HZ 26A H2 25A H1 575V 60HZ 230V 60HZ 26A 25A 380V H2 H3 H1 H2 26A H3 415V H4 22 EQUIPMENT GROUND 41 40 41 40 C A 3 3 M M 3 3 4 3 2 1 1X5-6 811 1X5-7 812 1X5-8 818 1X5-5 W3 E-STOP W2 17 18 19 20 23 24 25 26 A L1 12 A L1 B C A L2 L3 L1 6Q2 B C A L2 L3 L1 B C L2 L3 B C L2 L3 6Q1 3 2 1 817 16 6K5 18 17 6K4 20 19 24 6F2 23 26 6F1 25 HEATERS CIRCUIT 3 1X6-2 636 1X6-1 42 43 42 6Q7 43 N 634 CONTROL PANEL WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT AND TAG PROCEDURES BEFORE SERVICING. INSURE THAT ALL MOTOR CAPACITORS HAVE DISCHARGED STORED VOLTAGE. UNITS WITH VARIABLE SPEED DRIVE, REFER TO DRIVE INSTRUCTIONS FOR CAPACITOR DISCHARGE. FAILURE TO DO THE ABOVE COULD RESULT IN DEATH OR SERIOUS INJURY. USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTORS. FAILURE TO DO THE ABOVE COULD RESULT IN EQUIPMENT DAMAGE. H 4 Equipment Submittal Page 19 of 20

Field Wiring - Air-Cooled Scroll 1 2 3 4 5 6 7 8 9 10 11. 12 13. 14. 15 16 17 18 19 20 21 22 23 24 SINGLE SOURCE POWER IS PROVIDED AS STANDARD ON THESE PRODUCTS, FIELD CONNECTIONS ARE MADE TO 1X1, OR 1Q2. FOR VOLTAGES 200V/60HZ, 220V/50HZ, 380V/60HZ, 460V/60HZ, WIRE 26A SHALL BE CONNECTED TO H2. FOR VOLTAGES 230V/60HZ & 575V/60HZ, WIRE 26A SHALL BE CONNECT TO H3. 400V/50HZ UNIT IS FACTORY WIRED WITH 26A CONNECTED TO H3 - RECONNECT WIRE 26A TO H2 FOR 380V/50HZ, OR H4 FOR 415V/50HZ. H4 IS ONLY AVAILABLE WITH 400V/50HZ PANELS. FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP (PTYP=NONE). THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY (PTYP=DHHP). CUSTOMER SUPPLIED POWER 115/60/1 OR 220/50/1 TO POWER RELAYS. MAX. FUSE SIZE IS 20 AMPS. GROUND ALL CUSTOMER SUPPLIED POWER SUPPLIES AS REQUIRED BY APPLICABLE CODES. GREEN GROUND SCREWS ARE PROVIDED IN UNIT CONTROL PANEL. WIRED TO NEXT UNIT. 22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22P0014216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (BAS) COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. WIRED TO TRACER OR OTHER TRANE REMOTE DEVICE. 22 AWG SHIELDED COMMUNICATION WIRE EQUIVALENT TO HELIX LF22P0014216 RECOMMENDED. THE SUM TOTAL OF ALL INTERCONNECTED CABLE SEGMENTS NOT TO EXCEED 4500 FEET. CONNECTION TOPOLOGY SHOULD BE DAISY CHAIN. REFER TO BUILDING AUTOMATION SYSTEM (BAS) COMMUNICATION INSTALLATION LITERATURE FOR END OF LINE TERMINATION RESISTOR REQUIREMENTS. WIRED TO CUSTOMER CHILLED WATER SET POINT 2-10V OR 4-20mA. WIRED TO CUSTOMER EXTERNAL DEMAND LIMIT 2-10V OR 4-20mA. WIRED TO CUSTOMER 2-10V OR 4-20mA % CAPACITY ANNUNICIATOR. WIRED TO TRACER OR OTHER REMOTE DEVICE. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC ELECTRICAL CONNECTION INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. ALL UNIT POWER WIRING MUST BE 600 VOLT COPPER CONDUCTORS ONLY AND HAVE A MINIMUM TEMPERATURE INSULATION RATING OF 90 DEGREE C. REFER TO UNIT NAMEPLATE FOR MINIMUM CIRCUIT AMPACITY AND MAXIMUM OVERCURRENT PROTECTION DEVICE. PROVIDE AN EQUIPMENT GROUND IN ACCORDANCE WITH APPLICABLE ELECTRIC CODES. REFER TO WIRE RANGE TABLE FOR LUG SIZES. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND LOCAL REQUIREMENTS. ALL CUSTOMER CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUM INSULATION RATING OF 300 VOLTS. EXCEPT AS NOTED, ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARD MOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG OR DIN RAIL MOUNTED SPRING FORCE TERMINALS. UNIT PROVIDED DRY CONTACTS FOR THE CONDENSER/CHILLED WATER PUMP CONTROL. RELAYS ARE RATED FOR 7.2 AMPS RESISTIVE, 2.88 AMPS PILOT 1 DUTY, OR 3 HP, 7.2 FLA AT 120 VOLTS 60 HZ, CONTACTS ARE RATED FOR 5 AMPS GENERAL PURPOSE DUTY 240 VOLTS. CUSTOMER SUPPLIED CONTACTS FOR ALL LOW VOLTAGE CONNECTIONS MUST BE COMPATABLE WITH DRY CIRCUIT 24 VOLTS DC FOR A 12 ma RESISTIVE LOAD. SILVER OR GOLD PLATED CONTACTS RECOMMENDED. FIELD CONNECTIONS ARE ONLY MADE IN A CUSTOMER PROVIDED PUMP. THESE CONNECTIONS WILL BE MADE BY THE FACTORY WHEN THE PUMP IS PROVIDED BY THE FACTORY. CUSTOMER SUPPLIED POWER 115V, 60Hz, 1PH. CUSTOMER SUPPLIED 3 PHASE POWER. OPTIONAL FIELD ASSIGNED PROGRAMMABLE RELAYS (STAT=PRLY). CLASS 1 FIELD WIRED MODULE, RELAY AT 120V: 7.2A RESISTIVE 2.88A PILOT DUTY, 1/2 HP 7.2FLA; AT 240VAC: 5 AMPS GENERAL PURPOSE. WIRED TO CUSTOMER 0-10 VDC PUMP SPEED SIGNAL. WHEN FACTORY PROVIDED PUMP IS NOT SELECTED. CUSTOMER MUST SUPPLY SUITABLE PUMP SYSTEM. REFER TO PUMP MANUFACTURER FOR WIRING REQUIREMENTS. THE CONTACTS FOR AUTO STOP AND EMERGENCY STOP SWITCHES ARE JUMPERED AT THE FACTORY BY JUMPERS W2 & W3 TO ENABLE UNIT OPERATION. IF REMOTE CONTROL IS DESIRED, REMOVED THE JUMPERS AND CONNECT TO THE DESIRED CONTROL CIRCUIT. 1A15, LCI MODULE USED WHEN (COMM = LCI). 1A41, BACNET INTERFACE MODULE USED WHEN (COMM = BCNT). Equipment Submittal Page 20 of 20