Slim Contour Unit Cooler

Similar documents
Slim Contour Unit Cooler

Center Mount Unit Coolers

Low Profile Unit Coolers

Low Profile Unit Coolers

Low Flow Unit Coolers

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LOW PROFILE UNIT COOLER

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Packaged refrigeration system Technical Guide

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

Industrial Unit Coolers

Packaged Refrigeration Systems

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

PRO 3 TOP MOUNT & SIDE MOUNT PACKAGED REFRIGERATION SYSTEMS Technical Guide

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

T H I N K I N S I D E T H E B o x

Air-Cooled Condensers

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Air-Cooled Condensing Units with Compact Screw Compressors

Price List. BN-PL Oct. 2017

Price List. BN-PL Jan. 2018

LK-PL Jan Price List

commercial refrigeration products

High Profile Evaporator

Price List. CC-PC-PL Jan. 2019

KTL Two-Way Low Profile Evaporators

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Air-Cooled Condensers

Distributed Systems Sales Brochure

BTL Two-Way Low Profile Evaporators

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

The Endura Series. Options. The right combination of versatility, efficiency and reliability in foodservice equipment.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

KTL Two-Way Low Profile Unit Coolers

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL SPECIFICATIONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

JCseries EVAPORATIVE CONDENSER. engineering data

Unit Coolers. Installation and Operations Manual. Table of Contents. H-IM-UC November 2017 Part No

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

KR Electrical Defrost Unit Coolers (PN E108318_E)

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

AirV Standard-Profile RV Air Conditioning

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

KR Series Air Defrost Unit Coolers Operating and Installation Manual

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

TLV Low Velocity Evaporators

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

RCTA Horizontal Evaporator Coil Installation Instructions

Split System Heat Pumps

3-22 HP CONDENSING UNITS Technical Guide

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

TECHNICAL SPECIFICATIONS

Cooling/Heat Pump Convertible Air Handlers

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Modular Multi-position Air Handler

Variable Speed Convertible Air Handler 5 Ton

VERTICAL FAN COIL UNITS

Cooling/Heat Pump Convertible Air Handlers

The Right Choice For The Refrigeration Professional

Condensing Units w/ Screw Compressors

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Vertical Upflow Horizontal Left Air Handlers

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

ThermoSaver TM Hot Gas Defrost System

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Transcription:

Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016

ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim Contour, an innovative unit cooler with a space-saving design, offers enhanced serviceability and maximum cooling performance for food service and food retail markets. The Slim Contour unit cooler is ideal for applications where maximizing storage capacity in a walk-in cooler or freezer is critical, without sacrificing performance. At less than 11 inches in height, this unit cooler has a 30% reduction in unit height compared to traditional unit coolers in the market today. The unit comes standard with energy efficient EC (Electronically Commutated) motors, and can be paired with the Heatcraft Beacon II Refrigeration System for additional energy efficiency and performance gains. Application Air Defrost/medium temperature walk-in cooler Electric Defrost/low temperature walk-in freezer Coil Refrigerant optimized small diameter coil pattern Air Mover Energy efficient EC motors standard Backward curved centrifugal fan for optimal air flow and more uniform temperatures Cabinet Hybrid design of metal and a ABS resin Factory Mounted Options Heatcraft Beacon II Refrigeration System Quick Response Controller Mounted Thermostat Mounted Solenoid Valve Mounted Thermostatic Expansion Valve (TXV) Reduced Profile for Added Walk-In Storage 30% Slimmer Unit Height Slimmer unit height allows for improved storage space Reduced Drain Line Height Angled Drain Line Design Minimal drain line height increases product storage Reduced drain line damage Ease of Service Removable, Modular Fan Cassettes Allows for easy access to all components for cleaning Serviceable outside of walk-in in a warmer environment Removable Fan Guard Easily removed, attached with two screws Made from durable polymer that is dishwasher safe Mechanical and Electrical Access on Same Side Allows for easier unit service Energy Efficiency & Sustainability Energy Efficient Motors EC Motors come standard on all models MODULAR CASSETTE DESIGN Optimized Coil for Reduced Refrigerant Charge Up to a 40% reduction in refrigerant charge 2

Heatcraft Unit Cooler Portfolio Low Profile Slim Contour Center Mount The industry standard for walk-in cooler applications. Offering the broadest capacity range, from 4,000 to 37,000 BTUH, the low profile unit cooler is designed for maximum air flow and cooling capacity inside a walk-in cooler. Optimized for air and electric defrost applications, the Slim Contour unit cooler is ideally suited for installations where storage space is critical and a higher pull down capability is desired. Available in air or electric defrost, the Center Mount unit is ideal for tight storage situations due to its height of less than 9. The center mount design provides a moderated, evenly distributed air flow throughout the box. More Space Where You Need It Most Before After THE CHALLENGE Traditional unit coolers take up valuable space within a walk-in cooler. The drain line also extends another 6" beneath the unit; making it prone to damage and further reducing storage space. Servicing the unit is also a challenge as the coil and drain pan cannot be easily accessed for cleaning. THE SOLUTION The Slim Contour unit cooler is optimized for applications where space, performance, and serviceability cannot be compromised. The slim 11" height, coupled with modular, removable fan cassettes and a rear swept 10 drain maximize storage space while improving serviceability. 3

The Most Serviceable Unit Cooler Available The Slim Contour units are a hybrid design, made from high strength polymer ABS resin and metal, while fans are modular and are easily removed to fully expose the coil and drain pan for easy cleaning. Modular, removable air mover cassette Allows for easy access to components for thorough cleaning Modular cassettes allow for service in warmer environments Removable fan guards Fan guards are easily removed and easily cleaned Made from durable polymer that is dishwasher safe Mechanical and electrical service access on same side Allows for easier, faster service and installation with access to all critical electrical and mechanical components on one side Improved Air Coverage Over Traditional Unit Coolers Traditional Unit Cooler Slim Contour Unit Cooler The Slim Contour unit cooler circulates air using a centrifugal fan design, allowing air to circulate at higher velocities for more uniform temperatures in foodservice walk-in coolers and freezers. 4

Exceptional Cooling Performance The Slim Contour features a capacity range that mirrors that of the existing unit coolers in the Heatcraft unit cooler portfolio. Capacity Comparison - Air Defrost Models 0 Slim Contour Center Mount Low Profile ULA041 SM052 ULA050 ADT052 ULA072 SM076 ADT065 ULA100 SM090 ADT090 ADT070 SM102 ADT104 ULA132 SM134 ADT130 ULA153 SM156 ADT156 ADT140 ADT040 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 Only 1-3 Fan units shown. Center Mount Available in 1-5 Fans & Low Profile Available in 1-6 fan models. Capacity Comparison - Electric Defrost Models Slim Contour Center Mount Low Profile ULE035 SME040 LET035 ULE043 LET047 LET040 ULE068 SME065 SME054 LET065 LET075 ULE092 SME090 LET090 ULE112 SME130 LET120 ULE140 LET140 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 Only 1-3 Fan units shown. Center Mount Available in 1-5 Fans & Low Profile Available in 1-6 fan models. 5

Nomenclature UL A 041 A E A Model Series Defrost Type Capacity Electrical Code Motor Code Vintage UL = Slim Contour Performance Data A = Air Defrost E = Electric Defrost Model ULA - Air Defrost 50 Hz* / 60 Hz Model 10 F TD -20 F SST R-404A 6 C TD -29 C SST # BTUH x 100 (R-404A) A = 115v/1/60Hz B = 208-230v/1/60Hz Capacity R-407A/C/F, R-448A/R-449A 10 F TD -20 F SST BTUH Watts BTUH Watts *For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor) E = EC Motor Fan Data 6 C TD -29 C SST No. CFM m 3 H ULA041 4,100 1,200 4,700 1,380 1 530 900 ULA050 5,000 1,460 5,800 1,700 1 530 900 ULA072 7,200 2,110 8,200 2,400 2 1,090 1,852 ULA100 10,000 2,930 11,600 3,400 2 1,090 1,852 ULA132 13,200 3,870 15,300 4,490 3 1,675 2,846 ULA153 15,300 4,480 17,700 5,200 3 1,675 2,846 Model ULE - Electric Defrost 60 Hz Model 10 F TD -20 F SST R-404A 6 C TD -29 C SST Capacity Correction Factors - Electric Defrost Capacity R-407A/C/F, R-448A/R-449A 10 F TD -20 F SST BTUH Watts BTUH Watts Fan Data 6 C TD -29 C SST No. CFM m 3 H ULE035 3,500 1,030 3,900 1,130 1 530 900 ULE043 4,300 1,260 4,800 1,410 1 530 900 ULE068 6,800 1,990 7,800 2,270 2 1,090 1,852 ULE092 9,200 2,700 10,300 3,020 2 1,090 1,852 ULE112 11,200 3,280 12,800 3,740 3 1,675 2,846 ULE140 14,000 4,100 16,000 4,680 3 1,675 2,846 Standard Suction Temperature F Multiply Capacity By 20 1.15-10 1.04-20 1.00 6

Specifications Model HP EC Motors Defrost Heaters 115/1/60 208-230/1/60 208-230/1/60 Amps Watts Amps Watts Amps Watts ULA041 1/15 1.2 72 0.6 72 - - ULA050 1/15 1.2 72 0.6 72 - - ULA072 1/15 2.4 144 1.2 144 - - ULA100 1/15 2.4 144 1.2 144 - - ULA132 1/15 3.6 216 1.8 216 - - ULA153 1/15 3.6 216 1.8 216 - - ULE035 1/15 - - 0.6 72 3.5 800 ULE043 1/15 - - 0.6 72 3.5 800 ULE068 1/15 - - 1.2 144 6.3 1450 ULE092 1/15 - - 1.2 144 6.3 1450 ULE112 1/15 - - 1.8 216 9.4 2150 ULE140 1/15 - - 1.8 216 9.4 2150 Physical Data Model No. of Fans FPI Coil Data Coil Inlet (OD) Coil Outlet (OD) Condensate Drain (NPS) Defrost Type Approx. Weight (lbs) ULA041 1 7 1/2 5/8 3/4 Air 36 ULA050 1 7 1/2 7/8 3/4 Air 40 ULA072 2 7 1/2 7/8 3/4 Air 64 ULA100 2 7 1/2 7/8 3/4 Air 68 ULA132 3 7 1/2 7/8 3/4 Air 93 ULA153 3 7 1/2 7/8 3/4 Air 98 ULE035 1 7 1/2 5/8 3/4 Electric 40 ULE043 1 7 1/2 7/8 3/4 Electric 44 ULE068 2 7 1/2 7/8 3/4 Electric 68 ULE092 2 7 1/2 7/8 3/4 Electric 72 ULE112 3 7 1/2 7/8 3/4 Electric 98 ULE140 3 7 1/2 7/8 3/4 Electric 102 NET 7

Replacement Parts Right source. Right parts. Right now. InterLink Commercial Refrigeration Parts by Heatcraft Worldwide Refrigeration is your link to a complete line of dependable and certified commercial refrigeration parts, accessories and innovative electronic controls for all Heatcraft equipment. With InterLink, we provide our wholesalers with a comprehensive selection of product solutions and innovative technologies for the installed customer base. And every product is built to ensure the same high performance standards with which all Heatcraft Worldwide Refrigeration brands are built backed by a dedicated team to serve every customer need, delivering at the best lead times in the industry. Dependable. Versatile. Courteous. Finally, one simple source for all your replacement needs from a brand you can trust. For parts, please contact (800) 686-7278 or visit heatcraftrpd.com Replacement Parts Commercial Refrigeration Parts by Heatcraft Worldwide Refrigeration Part Number Description Part Number Description Drain Pans Motor/Motor Assemblies 55563501 Drain Pan - 1 Fan 55563601 Drain Pan - 2 Fan 55563701 Drain Pan - 3 Fan Heaters 24799801 Coil Heater - 1 Fan 24799802 Coil Heater - 2 Fan 24799803 Coil Heater - 3 Fan 24799901 Drain Pan Heater - 1 Fan 24799902 Drain Pan Heater - 2 Fan 25322001 115v Motor 25322101 208/230v Motor 89956801 Motor Cassette - 115v 89956802 Motor Cassette - 208/230v 22919301 Motor Blower Panels 89956301 Non-Service End Panel 89955501 Service End Panel 37001101 Fan Guard 24799903 Drain Pan Heater - 3 Fan Nozzle Selections ULA041 5/32 10 3 L-1/4 L-1/4 L-1/2 L-1/4 ULA050 5/32 10 4 L-1/3 L-1/3 L-1/2 L-1/4 ULA072 5/32 10 4 L-1/2 L-1/2 L-3/4 L-1/3 ULA100 5/32 10 8 L-3/4 L-3/4 L-1 L-1/2 ULA132 5/32 10 6 L-1 L-1 L-1-1/2 L-3/4 ULA153 5/32 10 8 L-1 L-1 L-1-1/2 L-3/4 ULE035 5/32 10 3 L-1/2 L-1/3 L-1/2 L-1/4 ULE043 5/32 10 4 L-1/2 L-1/2 L-3/4 L-1/3 ULE068 5/32 10 4 L-3/4 L-3/4 L-1 L-1/2 ULE092 5/32 10 8 L-1 L-1 L-1-1/2 L-3/4 ULE112 5/32 10 6 L-1-1/2 L-1-1/2 L-2 L-3/4 ULE140 5/32 10 8 L-1-1/2 L-1-1/2 L-2 L-1 NOTE: Nozzles sized for 90-100 F liquid temperature at expansion valve. Contact Application Engineering for guidance if Liquid temperature is not 90-100 F Evaporator TD is not 10-15 F (room temperature saturated suction temperature) Electric defrost and hot gas models with a saturated suction temperature of 10 F or higher Caution: Refrigeration system will not perform properly without correct nozzle! *R-22 Nozzles for informational purposes only. Not included with stocking evaporators 8

Dimensional Information Dimensions - Non-Model Specific Side Dimensions Detail A - Dimensions 1.81 5.45 2.69 1.44 Air Flow 10.73 11.35 0.875 X 1.125 KO Back Panel Elect. Access 8.43 8.61 8.83 Suction Route Liquid Line thru 0.875 hole **FIELD SUPPLY** Dimensions - Model Specific One Fan Model Dimensions Two Fan Model Dimensions 52.13 2.84 2.00 7.52 5.55 15.56.99 Suction see detail A Liquid see detail A 31.13 22.30 Drain Pan Fitting 1.30 2.85 2.02 7.52 5.55 26.06 Suction see detail A 43.30 Drain Pan Fitting 1.30 19.93 4.45 0.875 X 1.125 KO Top Panel Elect. Access 18.70 21.93 19.91 Liquid see detail A 18.70 21.80 2.06 Three Fan Model Dimensions 36.56 7.52 21.06 43.25 1.30 5.55 2.85 2.02 Suction see detail A Drain Pan Fitting 19.91 Liquid see detail A 16.50 18.70 21.93 9

10 Notes

Notes 11

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice. LK-SLIM-0418 Version 000