Datasheet - MZM 100 ST2-1P2PWREM-A

Similar documents
Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM ZRK 24 VAC/DC

Datasheet - TVS /B-M20

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

SLC 220 E/R RFBS

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

PROTECT SRB 200EXi-1A

Operating Manual MS220KA and MSR220KA

Multifunctional Gate Box MGB. More than safety.

One giant leap for safety: AZM400.

SensaGuard TM Integrated Latch Installation Instructions

Overload relays. General descriptions. Configuration of the front

Original operating instructions Safety switch with guard locking AC901S AC902S

Conformity Approvals Rated insulation voltage Ui

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating Manual MS220DA

Inductive slot sensor

Original instructions Sense7-series Non-contact coded safety switch

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Technical Data. General specifications. Rated operating distance s n 5 mm

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Technical Data. Dimensions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

ISIS SAFETY SYSTEM Installation guide

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Rules for Classification and Construction Additional Rules and Guidelines

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

HMN-D2 Insert Series

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Safety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO

Safety in system: Protection for man and machine Innovations 2016/2017

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

COMPACT FLAME CONTROLLER CFC 2000

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Model 144H. Product Data Sheet , Rev DB February Content

COMPACT FLAME CONTROLLER CFC 1000

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

BC3250. Blowdown Controller

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Integrated Solutions Low Voltage Systems

TEM-EX-B. Figure: TEM-EX-B with PROMOS connector. ka055100en; Rev. 1.8

Dräger Polytron 7000 Fixed gas detector

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Installation / Monitoring Technique

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating Manual MS220VA and MSR220VA

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

MICRO SWITCH GSX Series

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

SCHMIDT LED Measured Value Display MD Instructions for Use

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Proservo NMS5- / NMS7-

LOVAG TEST INSTRUCTION IEC/EN

Liquiphant S, Nivotester FDL60/61, FTL670

Functional Safety Manual Oil Leak Detector NAR300 System

Improved productivity Two-stage detection

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Magnetically Coded Non-contact Switch (MC2)

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Engineering Guideline. pac- Carriers Type Universal

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

STATUS ALARM HISTORY ALARM RESET

Snifter ATEX22 VERSION. User Manual. Distributor

Packaging industry Food and Beverage Solutions

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

Safety Sensor Eden AS-i Machine safety - Jokab Safety products

E3M-V. Mark Sensor. Applications

Technical Data. Dimensions

Operating Guide Safe Torque Off

Transcription:

30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating and unique operating principle 40 mm x 179 mm x 40 mm Electronic contact-free, coded system thermoplastic enclosure Max. length of the sensor chain 200 m 3 LEDs to show operating conditions Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally Intelligent diagnosis Self-monitoring series-wiring of 31 sensors Patented Connector M12, 8-pole Power to lock (Minor differences between the printed image and the original product may exist!) Ordering details Product type description MZM 100 ST2-1P2PWREM-A Article number 101211067 EAN code 4030661389134 ecl@ss 27-27-26-03 Approval Approval BG USA/CAN Classification Standards EN ISO 13849-1, IEC 61508, IEC 60947-5-3, EN 60947-5-1 PL e Control category up 4 PFH 3.5 x 10-9/h SIL up 3 Mission time 20 Years Classification PDF-M Global Properties

Product name MZM 100 Standards IEC 61508, EN ISO 13849-1, EN ISO 13849-1 Compliance with the Directives (Y/N) Suitable for safety functions (Y/N) Protection rating II Series-wiring up to 31 components Length of the sensor chain max. 200 m without detriment to the category to EN ISO 13849-1 Active principle inductive Duty cycle 100 % Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic Housing coating ne Weight 480 g Guard locking monitored (Y/N) Actuator monitored (Y/N) Idle assignable pushbutton and LED (Y/N) Reaction time < 150 ms Duration of risk < 150 ms Time to readiness < 4000 ms Recommended actuator MZM 100-B1.1 Mechanical data Design of electrical connection Mechanical life notice - Mechanical life restistance to shock Resistance to vibration Emergency unlocking device (Y/N) Manual release (Y/N) Emergency release (Y/N) Latching (Y/N) electrically adjustable latching force Permanent magnet Connector M12, 8-pole 1.000.000 operations operations for guards 5 kg; actuating speed 0,5 m/s 30 g / 11 ms 10 150 Hz, Amplitude 0,35 mm 30 N 100 N 30 N Clamping force Fmax - typically 750 N - guaranteed 500 N Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +55 C Storage and transport temperature - Min. Storage and transport temperature 25 C - Max. Storage and transport temperature +85 C Relative humidity 30%... 95% - non-condensing - non-icing Protection class IP67 to IEC/EN 60529 Air clearances and creepage distances To IEC/EN 60664-1

- Rated impulse withstand voltage Uimp 0,8 kv - Overvoltage category III - Degree of pollution 3 Electrical data Number of auxiliary contacts Number of safety contacts Cross circuit/short circuit recognition possible (Y/N) Power to unlock Power to lock Supply voltage UB (stabilised PELV) 0 piece 2 piece - Min. supply voltage 20.4 VDC - Max. supply voltage 26.4 VDC Switch frequency Rated insulation voltage Ui Utilisation category -load current I0 Required rated short-circuit current 1 Hz 32 VDC 1 A DC-13 max. 0,5 A 100 A Device insulation 2 A (if used in accordance with UL 508) notice Cable length and cable section alter the voltage drop depending on the output current Electrical data - Safety inputs Safety inputs Rated operating voltage Ue X1 and X2 3 V 5 V (Low) 15 V 30 V (High) > 2 ma / 24 V Electrical data - Safety outputs Safety outputs Fuse rating Rated operating voltage Residual current Ir Utilisation category Y1 and Y2 short-circuit proof, p-type 0 V... 4 V under Supply voltage UB 0,5 ma 0,25 A DC-12, DC-13 Electrical data - Diagnostic output Serial diagnostics (Y/N) Fuse rating Rated operating voltage Utilisation category Wiring capacitance for serial diagnostics - diagnostic signals Operating principle of the diagnostic output notice p-type, short-circuit proof 3 V 5 V (Low) 15 V 30 V (High) 0,05 A DC-12, DC-13 guard door closed The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC. The diagnostic output is not a safety-relevant output! Electrical data - Solenoid control IN

Rated operating voltage Ue 3 V 5 V (Low) 15 V 30 V (High) typically 10 ma / 24 V, dynamically 20 ma LED switching conditions display LED switching conditions display (Y/N) LED switching conditions display - Supply voltage UB green LED - switching condition yellow LED - Error functional defect red LED ATEX Explosion protection categories for gases Explosion protected category for dusts ne ne Dimensions Dimensions of the sensor - Width of sensor 40 mm - Height of sensor 179 mm - Length of sensor 40 mm Pin assignment 1 A1 Supply voltage UB 2 X1 Safety input 1 3 A2 GND 4 Y1 Safety output 1 5 OUT Diagnostic output 6 X2 Safety input 2 7 Y2 Safety output 2 8 IN Solenoid control 9 without function notice As lons as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. The safety outputs then will be enabled again; opening the safety guard therefore is not required. Included in delivery Actuators must be ordered separately. Ordering code MZM 100 (1) ST Guard locking monitored MZM 100 (1)-(2)(3)(4)-A connector M23, (8 + 1-pole)

ST2 (2) 1P2PW SD2P (3) without RE (4) M connector M12, 8-pole 1 Diagnostic output and 2 Safety outputs, p-type, combined diagnostic signal: guard door closed and interlocking device locked serial diagnostic output and 2 Safety outputs, p-type without Latching force electrically adjustable latching force 30 100 N Permanent magnet approx. 30 N Actuator monitored MZM 100 B (1)-(2)RE(3)-A (1) ST ST2 (2) 1P2PW2 SD2P (3) M B RE A connector M23, (8 + 1-pole) connector M12, 8-pole 1 diagnostic output and 2 safety outputs, all p-type and combined diagnostic signal: safety guard closed and solenoid interlock locked. serial diagnostic output and 2 Safety outputs, p-type Permanent magnet approx. 30 N Indication legend Actuator monitored electrically adjustable latching force 30 100 N Power to lock Documents Operating instructions and Declaration of conformity (pt) 349 kb, 27.01.2012 Code: mrl_mzm100_pt Operating instructions and Declaration of conformity (fr) 316 kb, 03.06.2013 Code: mrl_mzm100_fr Operating instructions and Declaration of conformity (de) 325 kb, 21.11.2012 Code: mrl_mzm100_de Operating instructions and Declaration of conformity (en) 321 kb, 21.11.2012 Code: mrl_mzm100_en Operating instructions and Declaration of conformity (nl) 322 kb, 14.01.2013 Code: mrl_mzm100_nl Operating instructions and Declaration of conformity (it) 322 kb, 29.11.2012 Code: mrl_mzm100_it Operating instructions and Declaration of conformity (jp) 610 kb, 14.01.2013 Code: mrl_mzm100_jp Operating instructions and Declaration of conformity (it) 322 kb, 29.11.2012 Code: mrl_mzm100_it Operating instructions and Declaration of conformity (pl) 354 kb, 02.12.2014

Code: mrl_mzm100_pl Operating instructions and Declaration of conformity (es) 906 kb, 28.06.2011 Code: mrl_mzm100_es Operating instructions and Declaration of conformity (cn) 446 kb, 27.05.2015 Code: mrl_mzm100_cn Wiring example (de) 41 kb, 29.09.2009 Code: kmzm1p01 Wiring example (99) 19 kb, 22.01.2009 Code: kmzm1l03 BG-test certificate (de) 2 MB, 26.08.2014 Code: z_mzmp03 Images Dimensional drawing (basic component) Dimensional drawing (miscellaneous) Contact arrangement

Wiring example System components Actuator 101204290 - MZM 100-B1.1 actuator free from play i.e. neutralisation of undesired noises Accessories 101210642 - MZM 100 TARGET for the variable setting of the latching force gradually adjustable by steps of approx. 10 N within a range from approx. 30 N to 100 N 101185510 - MS MZM 100-W Connector A-K8M12 Pre-wired cable 8-pole K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 30.05.2015-14:45:09h Kasbase 3.1.12.F.64I