Fire Alarm and Life Safety System Inspection Certificate

Similar documents
Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Fire Alarm and Life Safety System Inspection Certificate

Sprinkler Inspection Certificate

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

PURCHASING DEPARTMENT DIVISION OF BUDGET & FINANCE

Functional Performance Test

SecurityScan Inspection Certificate

Fire Alarm Testing and Inspection Report

INSPECTION AND TESTING FORM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Fire Alarm System Fundamentals

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Florida Building Code 2010

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Changes in NFPA

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

Fire Alarm System Inspection and Testing Report

The 2013 National Fire Alarm and Signaling Code

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

2018 NICET Code Transition Changes

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

LifeAlarm Fire Alarm Control Panels

Unified Fire Authority - Fire Prevention Bureau

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

FIRE & LIFE SAFTEY STANDARD

Full Service Central Station Fire Alarm Listing Evaluation

NFPA Changes

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

NFPA 72 Code Changes vs 2013

University Design Standard Fire Alarm Systems

A. Provide addressable fire alarm system throughout the facility and supervise wet and preaction fire sprinkler system.

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

3.1 Introduction. 3.1 Introduction

SECTION FIRE ALARM SYSTEMS

Building Name: Our Lady of Sorrows Date: July 10, 2013

Chapter 4: Fire Protection Systems

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Division 28 - Electronic Safety and Security

SECTION FIRE ALARM SYSTEMS

OKLAHOMA STATE UNIVERSITY

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Bold items are particular to the City of Euless

Fire Alarm, Water Flow Alarm & Signaling Systems

Facilities Management

NFPA Changes

VSC Fire & Security, Inc.

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

rpsa FIRE PROTECTION ENGINEERS

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Ventura County Community College District 761 E. Daily Drive, West Stanley Avenue, St. 200, Camarillo, CA Purchasing Department

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION FIRE ALARM SYSTEM (POINT GRAPHIC SYSTEM)

SECTION ADDRESSABLE FIRE ALARM SYSTEM

PART IV DETAILED SPECIFICATION

IN2 Digital, Addressable Fire-alarm System

1.3 REFERENCE STANDARDS

WHEA FSE inspections.

MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

Voice Annunicated Fire Alarm System Page 1 of 26

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

1. The fire detection and alarm system (including the conduit) shall be a separate bid item and not part of the general electrical contract.

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

THE BASICS OF FIRE ALARM PLAN REVIEW

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Protecting Your Property: Well Do You Know Your Fire Fire Systems Systems. Joe Szewczyk, Risk Control Consultant

Fire - Rescue. November 2016

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

AND ARCHITECT SPECIFICATIONS

Fire Alarm Wiring. Circuit types, styles and limitations

Environmental Health & Safety

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Transcription:

Fire Alarm and Life Safety System Inspection Certificate For Sample FireScan Healthcare 123 Main Street Anytown, State 55555 Tested to NFPA 72 Standards, 2007 Edition This Inspection was performed in accordance with applicable NFPA Standards. The subsequent pages of this report provide performance measurements, listed ranges of acceptable results, and complete documentation of the inspection. Whenever discrepancies exist between acceptable performance standards and actual test results, notes and/or recommended solutions have been proposed or provided for immediate review and approval. Inspection Date Oct 12, 2014 Building: Sample FireScan Healthcare Contact: John Williams Title: Administrator Company: BuildingReports Demonstration Company Contact: John Doe Title: Inspector

Executive Summary Generated by: BuildingReports.com Building Information Building: Sample FireScan Healthcare Contact: John Williams Address: 123 Main Street Phone: 555-555-5555 Address: City/State/Zip: Anytown, State 55555 Country: United States of America Inspection Performed By Company: BuildingReports Demonstration Company Fax: Mobile: Email: Inspector: John Doe Address: 1325 Satellite Blvd Phone: 770-555-5555 Address: Suite 1607 City/State/Zip: Suwanee, Georgia Fax: Mobile: Country: United States of America Email: jdoe@abcfire.com System Control Unit Manufacturer: SimplexGrinnell Inspection Date: 10/12/2014 IDC Style: Model Number: 4100U Install Date: 04/07/2005 SLC Style: Software Version: Version Date: 07/08/2009 NAC Style: Location: 1st FACP Room Current Protection: Monitoring Company: Acme Central Signal Phone: 555-559-5555 Account #: 2456RR Central Station Signal Verification Type: Digital Communicator Mfg: Silent Knight Model #: 5704 Test Time/Date: 10/12/14 10:54:18 AM Restore Time3:00pm Confirmed signals and restored system with operator 3. Type of Signal Signal Confirmation Notes Type: Alarm Confirmed Time: 4:30pm Confirmed with operator 5. Type: Supervisory Confirmed Time: 4:35pm Confirmed with operator 5. Type: Trouble Confirmed Time: 4:45pm Confirmed with operator 5. BuildingReports Demonstration Company 1 07/22/2014

Inspection Date: October, 12, 2014 Building: Sample FireScan Healthcare EC 02.03.05 EP 02 Six-month testing of tamper switches and quarterly testing of water-flow switches. Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Tamper Switch 0 0 0 5 5 Waterflow Switch 5 4 1 5 5 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Duct Detector 2 1 1 11 11 Heat Detector 0 0 0 4 5 Pull Station 6 5 1 15 15 Releasing Device 5 5 0 5 5 Smoke Detector 6 6 0 19 20 EC 02.03.05 EP 04 Annual test of visual and audible fire alarms, including speakers Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Horn/Strobe 6 6 0 6 6 Strobe 4 3 1 4 5 EC 02.03.05 EP 05 Quarterly test of fire alarm equipment for notifying off-site fire responders Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Communicator 1 1 0 1 1 Monitoring 3 3 0 3 3 EC 02.03.05 EP 19 Annual test of automatic smoke-detection shutdown devices for air-handling equipment Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Fan Shutdown 5 5 0 5 5 LS 02.01.34 EP 02 Protected master fire alarm control panel Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Control Panel 1 1 0 1 1 LS 02.01.34 EP 03 Approved location for remote annunciator panel Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Annunciator 1 1 0 1 1 LS 02.01.34 EP 04 All other Life Safety Code fire alarm requirements related to NFPA 101-2000: 18/19.3.4 Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Battery 6 6 0 6 6 Power Supply 2 2 0 2 2 LS 02.01.50 EP 04 Elevators are fully equipped and protected BuildingReports Demonstration Company 2 07/22/2014

Devices Tested This Quarter Pass Fail Tested YTD (2014) Total Quantity Elevator 2 2 0 2 2 Certification Company: BuildingReports Demonstration Company Building: Sample FireScan Healthcare Inspector: John Doe Contact: John Williams Signed: Oct 12, 2013 3:47:43 PM Signed: Oct 12, 2013 3:47:27 PM John Doe Certifications Certification Type Number IMSA Fire Alarm Interior Level I 123456 NICET Fire Alarm Systems Level II 456789 BuildingReports Demonstration Company 3 07/22/2014

Discrepancy Report Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Discrepancy Report consolidates each discrepancy listed within the various Testing sections of your Inspection. Discrepancies are listed by Category, and grouped by device type. The description of the problem is provided and where appropriate, code references are listed for your convenience. Any item that was inspected that is listed on the Consumer Product Safety Commission's website and is subject to a recall by the manufacturer is included. Device Type Manufacturer ModelNumber Date Qty Items listed for Recall by Manufacturer Control Panel SimplexGrinnell 4100U 02/08/2011 1 More Information: http://www.cpsc.gov/cpscpub/prerel/prhtml11/11721.html Smoke Detector SimplexGrinnell 4098-9714 05/19/2006 20 More Information: http://www.cpsc.gov/cpscpub/prerel/prhtml06/06551.html! ScanID " Location # Problem Address! Reference EC 02.03.05 EP 02 Waterflow Switch Six-month testing of tamper switches and quarterly testing of water-flow switches. 01821491 1st Stairwell A Failed Test 1-M1-12 NFPA 72 Table EC 02.03.05 EP 03 boxes, and smoke detectors. Duct Detector 10.4.2.2.14(i) Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm 01821587 1st Mechanical Room - Return Failed Test 1-M1-62 NFPA 72 Table Pull Station 10.4.2.2.14(g)4 01821575 1st Main Entrance Damaged/Worn 1-M1-52 NFPA 72 EC 02.03.05 EP 04 Strobe Annual test of visual and audible fire alarms, including speakers 10.2.1.2.2,3 01821524 1st Bathroom Failed Test 1 NFPA 72 Table NFPA 72 Table 10.4.2.2.14(i) NFPA 72 Table 10.4.2.2.14(g)4 NFPA 72 10.2.1.2.2,3 NFPA 72 Table 10.4.2.2.15(c) Code References 10.4.2.2.15(c) Water shall be flowed through an inspector's test connection indicating the flow of water equal to that from a single sprinkler of the smallest orifice size installed in the system for wet-type systems, or an alarm test bypass connection for dry-pipe, pre-action, or deluge systems in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems. Air duct detectors shall be tested or inspected to ensure that the device will sample the airstream. The test shall be made in accordance with the manufacturer's instructions. System defects and malfunctions shall be corrected. If a defect or malfunction is not corrected at the conclusion of system inspection, testing, or maintenance, the system owner or the owner's designated representative shall be informed of the impairment in writing within 24 hours. Test shall be performed in accordance with the manufacturer's published instructions. Appliance locations shall be verified to be per approved layout, and it shall be confirmed that no floor plan BuildingReports Demonstration Company 4 07/22/2014

changes affect the approved layout. It shall be verified that the candela rating marking agrees with the approved drawing. It shall be confirmed that each appliance flashes. BuildingReports Demonstration Company 5 07/22/2014

Proposed Solutions Report Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Proposed Solution Report provides a solution for each discrepancy listed on the Discrepancy Report. Provide a check mark where indicated to approve repairs listed within the report. Items listed as T/M are available for repair on a Time and Materials basis.! ScanID " Location # Solution Model # Cost Fix EC 02.03.05 EP 02 Six-month testing of tamper switches and quarterly testing of water-flow switches. Waterflow Switch 01821491 1st Stairwell A Replace VSR-1 T/M " EC 02.03.05 EP 03 boxes, and smoke detectors. Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm Duct Detector 01821587 1st Mechanical Room - Return 4098-9724 T/M " Pull Station 01821575 1st Main Entrance 4099-9201 T/M " EC 02.03.05 EP 04 Annual test of visual and audible fire alarms, including speakers Strobe 01821524 1st Bathroom Replace WXA-3GSX T/M " BuildingReports Demonstration Company 6 07/22/2014

Notes & Recommendations Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Notes & Recommendations Report details additional inspection notes made by the Inspectors during the course of the building inspection. ScanID Not EC 02.03.05 EP 02 e Device Type Location Comment Six-month testing of tamper switches and quarterly testing of water-flow switches. 01821491 1 Waterflow Switch 1st Stairwell A Failed Test Exceeded 90 second maximum limit. EC 02.03.05 EP 03 boxes, and smoke detectors. Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm 01821587 2 Duct Detector 1st Mechanical Room - Return Failed Test Device did not report an alarm to the panel. 01821575 3 Pull Station 1st Main Entrance Damaged/Worn The operable part of this device has been broken and will not activate an alarm. 01821569 4 Pull Station 2nd Stair B Damaged/Worn The operable part of this device has been broken and will not activate an alarm. EC 02.03.05 EP 05 Quarterly test of fire alarm equipment for notifying off-site fire responders 01821496 5 Communicator 1st FACP Room Passed Confirmed signals and restored system with operator 3. 65652855 6 Monitoring Passed Confirmed with operator 5. 68955855 7 Monitoring Passed Confirmed with operator 5. 38968896 8 Monitoring Passed Confirmed with operator 5. BuildingReports Demonstration Company 7 07/22/2014

Inspection & Testing Generated by: BuildingReports.com Building: Sample FireScan Healthcare The Inspection & Testing section lists all of the items inspected in your building, which are then categorized by the applicable EC Code. The most recent inspection is listed in the far right column and is based on the Finish Date of that inspection. The latest inspection uploaded in each previous quarter appears in the four columns to the left. Passed=P, Failed=F, Other=O Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 02 Six-month testing of tamper switches and quarterly testing of water-flow switches. Valve shall be operated and signal receipt shall be verified to be within the first two revolutions of the hand wheel or within one-fifth of the travel distance, or per the manufacturer's specifications. (NFPA 72 Table 7-2.2 (13h.1)) Tamper Switch 1st Stairwell A 01821490 1-M1-13 01/07-P 07/08-P Tamper Switch 2nd Stairwell A 01821488 1-M1-11 01/07-P 07/08-P Tamper Switch 3rd Stairwell A 01821485 1-M1-07 01/07-P 07/08-P Tamper Switch 4th Stairwell A 01821482 1-M1-05 01/07-P 07/08-P Tamper Switch 5th Stairwell A 01821480 1-M1-03 01/07-P 07/08-P Device Total: 5 BuildingReports Demonstration Company 8 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 02 Six-month testing of tamper switches and quarterly testing of water-flow switches. Water shall be flowed through an inspector's test connection indicating the flow of water equal to that from a single sprinkler of the smallest orifice size installed in the system for wet-pipe systems, or an alarm test bypass connection for dry-pipe, pre-action, or deluge systems in accordance with NFPA 25. (NFPA 72 Table 7-2.2 (13i)) Waterflow Switch 1st Stairwell A 01821491 1-M1-12 10/07-P 01/07-P 04/06-P 07/08-F 10/12-F Waterflow Switch 2nd Stairwell A 01821489 1-M1-10 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Waterflow Switch 3rd Stairwell A 01821487 1-M1-08 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Waterflow Switch 4th Stairwell A 01821486 1-M1-06 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Waterflow Switch 5th Stairwell A 01821481 1-M1-04 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Device Total: 5 BuildingReports Demonstration Company 9 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Air duct detectors shall be tested or inspected to ensure that the device will sample the airstream. The test shall be made in accordance with the manufacturer's instructions. (NFPA 72 Table 7-2.2 (13g.4)) Duct Detector 1st Mechanical Room - Supply 01821586 1-M1-60 10/07-P 10/12-P Duct Detector 1st Mechanical Room - Return 01821587 1-M1-62 10/07-P 10/12-F Duct Detector 2nd Mechanical Room - Return 01821584 1-M1-59 07/08-P Duct Detector 2nd Mechanical Room - Supply 01821585 1-M1-61 07/08-P Duct Detector 3rd Mechanical Room - Supply 01821556 1-M1-36 01/07-P Duct Detector 3rd Mechanical Room - Return 01821583 1-M1-58 07/08-P Duct Detector 4th Mechanical Room - Return 01821554 1-M1-34 01/07-P Duct Detector 4th Mechanical Room - Supply 01821555 1-M1-35 01/07-P Duct Detector 5th Mechanical Room - Supply 01821540 1-M1-29 04/06-P Duct Detector 5th Mechanical Room - Return 01821542 1-M1-30 04/06-P Duct Detector Penthouse Elevator Machine 01821538 1-M1-28 01/07-P Room Device Total: 11 BuildingReports Demonstration Company 10 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Restorable: Heat test shall be performed with a heat source per the manufacturer's recommendations for response within one minute. Non-Restorable: Heat test shall not be performed. Functionality shall be tested mechanically and electrically. (NFPA 72 Table 7-2.2 (13d)) Heat Detector 1st Telephone Room 01821581 1-M1-57 Heat Detector 2nd Telephone Room 01821580 1-M1-56 07/08-P Heat Detector 3rd Telephone Room 01821578 1-M1-55 07/08-P Heat Detector 4th Telephone Room 01821557 1-M1-37 01/07-P Heat Detector 5th Telephone Room 01821545 1-M1-33 04/06-P Device Total: 5 BuildingReports Demonstration Company 11 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Manual fire alarm boxes shall be operated per the manufacturer's instructions. Key-operated presignal and general alarm manual fire alarm boxes shall both be tested. (NFPA 72 Table 7-2.2 (13e)) Pull Station 1st Stair A 01821571 1-M1-49 10/07-P 10/12-P Pull Station 1st Stair B 01821572 1-M1-09 10/07-P 10/12-P Pull Station 1st Emergency Room 01821573 1-M1-50 10/07-P 10/12-P Pull Station 1st Loading Dock 01821574 1-M1-51 10/07-P 10/12-P Pull Station 1st Main Entrance 01821575 1-M1-52 10/07-P 10/12-F Pull Station 1st Cafeteria Exit 01821576 1-M1-53 10/07-P 10/12-P Pull Station 2nd Stair A 01821570 1-M1-48 07/08-P Pull Station 2nd Stair B 01821569 1-M1-47 07/08-F Pull Station 3rd Stair A 01821560 1-M1-40 07/08-P Pull Station 3rd Stair B 01821568 1-M1-02 07/08-P Pull Station 4th Stair A 01821559 1-M1-39 01/07-P Pull Station 4th Stair B 01821558 1-M1-38 04/06-P Pull Station 5th Stair A 01821543 1-M1-31 01/07-P Pull Station 5th Stair B 01821544 1-M1-32 01/07-P Pull Station Penthouse Elevator Machine 01821531 1-M1-20 04/06-P Room Device Total: 15 BuildingReports Demonstration Company 12 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Interface equipment connections shall be tested by operating or simulating the equipment being supervised. Signals required to be transmitted shall be verified at the control panel. (NFPA 72 Table 7-2.2 (19)) Releasing Device 1st Main Corridor 01821511 1 10/07-P 10/12-P Releasing Device 2nd Main Corridor 01821509 1 10/07-P 10/12-P Releasing Device 3rd Main Corridor 01821510 1 10/07-P 10/12-P Releasing Device 4th Main Corridor 01821508 1 10/07-P 10/12-P Releasing Device 5th Main Corridor 01821507 1 10/07-P 10/12-P Device Total: 5 BuildingReports Demonstration Company 13 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 03 Annual testing of duct detectors, electro-mechanical releasing devices, heat detectors, manual fire alarm boxes, and smoke detectors. Detectors shall be tested in place to ensure smoke entry into the sensing chamber and an alarm response. (NFPA 72 Table 7-2.2 (13g.1)) Smoke Detector 1st Electrical Room 01821597 1-M1-71 10/07-P 10/12-P Smoke Detector 1st Nurse's Station 01821598 1-M1-72 10/07-P 10/12-P Smoke Detector 1st Elevator Lobby 01821537 1-M1-27 04/06-P Smoke Detector 1st Mechanical Room 01821596 1-M1-69 Smoke Detector 2nd Mechanical Room 01821594 1-M1-68 10/07-P 10/12-P Smoke Detector 2nd Elevator Lobby 01821536 1-M1-26 04/06-P Smoke Detector 2nd Nurse's Station 01821591 1-M1-66 07/08-P Smoke Detector 2nd Electrical Room 01821592 1-M1-67 07/08-P Smoke Detector 3rd Mechanical Room 01821588 1-M1-63 07/08-P Smoke Detector 3rd Electrical Room 01821589 1-M1-64 07/08-P Smoke Detector 3rd Nurse's Station 01821590 1-M1-65 07/08-P Smoke Detector 4th Mechanical Room 01821567 1-M1-45 10/07-P 10/12-P Smoke Detector 4th Electrical Room 01821566 1-M1-46 10/07-P 10/12-P Smoke Detector 4th Nurse's Station 01821565 1-M1-44 10/07-P 10/12-P Smoke Detector 4th Elevator Lobby 01821535 1-M1-23 04/06-P Smoke Detector 5th Mechanical Room 01821561 1-M1-41 01/07-P Smoke Detector 5th Electrical Room 01821562 1-M1-43 01/07-P Smoke Detector 5th Nurse's Station 01821563 1-M1-42 01/07-P Smoke Detector 5th Elevator Lobby 01821534 1-M1-22 04/06-P Smoke Detector Penthouse Elevator Machine 01821532 1-M1-21 04/06-P Room Device Total: 20 BuildingReports Demonstration Company 14 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 04 Annual test of visual and audible fire alarms, including speakers Sound pressure level shall be measured with sound level meter meeting ANSI S1.4a, Specifications for Sound Level Meters, Type 2 requirements. Levels throughout protected area shall be measured and recorded. (NFPA 72 Table 7-2.2 (14a)) Horn/Strobe 1st Main Corridor 01821523 1 10/12-P Horn/Strobe 2nd Main Corridor 01821521 1 10/12-P Horn/Strobe 3rd Main Corridor 01821518 1 10/12-P Horn/Strobe 4th Main Corridor 01821516 1 10/12-P Horn/Strobe 5th Main Corridor 01821513 1 10/12-P Horn/Strobe Penthouse Elevator Machine 01821512 1 10/12-P Room Device Total: 6 BuildingReports Demonstration Company 15 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 04 Annual test of visual and audible fire alarms, including speakers Test shall be performed in accordance with the manufacturer's instuctions. (NFPA 72 Table 7-2.2 (14c)) Strobe 1st Bathroom 01821524 1 10/12-F Strobe 2nd Bathroom 01821522 1 10/12-P Strobe 3rd Bathroom 01821519 1 10/12-P Strobe 4th Bathroom 01821517 1 Strobe 5th Bathroom 01821514 1 10/12-P Device Total: 5 BuildingReports Demonstration Company 16 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 05 Quarterly test of fire alarm equipment for notifying off-site fire responders Test shall be performed on all system functions and features in accordance with the equipment manufacturer's instructions for correct operation in conformance with the applicable sections of Chapter 5. Initiating device shall be actuated. Receipt of the correct initiating device signal at the supervising station within 90 seconds shall be verified. Upon completion of the test, the system shall be restored to its functional operating condition. (NFPA 72 Table 7-2.2 (16a)) Communicator 1st FACP Room 01821496 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Device Total: 1 BuildingReports Demonstration Company 17 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 05 Quarterly test of fire alarm equipment for notifying off-site fire responders Test shall be performed on all system functions and features in accordance with the equipment manufacturer's instructions for correct operation in conformance with the applicable sections of Chapter 5. Initiating device shall be actuated. Receipt of the correct initiating device signal at the supervising station within 90 seconds shall be verified. Upon completion of the test, the system shall be restored to its functional operating condition. (NFPA 72 Table 7-2.2 (16a)) Monitoring 38968896 1 10/12-P Monitoring 65652855 1 10/12-P Monitoring 68955855 1 10/12-P Device Total: 3 BuildingReports Demonstration Company 18 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 EC 02.03.05 EP 19 Annual test of automatic smoke-detection shutdown devices for air-handling equipment Interface equipment connections shall be tested by operating or simulating the equipment being supervised. Signals required to be transmitted shall be verified at the control panel. (NFPA 72 Table 7-2.2 (19)) Fan Shutdown 1st AHU Room Unit 1A 01821506 1 10/12-P Fan Shutdown 2nd AHU Room Unit 2A 01821505 1 10/12-P Fan Shutdown 3rd AHU Room Unit 3A 01821504 1 10/12-P Fan Shutdown 4th AHU Room Unit 4A 01821502 1 10/12-P Fan Shutdown 5th AHU Room Unit 5A 01821500 1 10/12-P Device Total: 5 BuildingReports Demonstration Company 19 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 LS 02.01.34 EP 02 Protected master fire alarm control panel At a minimum, control equipment shall be tested to verify correct receipt of alarm, supervisory and trouble signals (inputs), operation of evacuation signals and auxiliary functions (outputs), circuit supervision including detection of open circuits and ground faults, and power supply supervision for detection of loss of ac power and disconnection of secondary batteries. (NFPA 72 Table 7-2.2 (1)) Control Panel 1st FACP Room 01821492 1 10/07-P 01/07-P 04/06-F 07/08-P 10/12-P Device Total: 1 BuildingReports Demonstration Company 20 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 LS 02.01.34 EP 03 Approved location for remote annunciator panel The correct operation and identification of annunciators shall be verified. If provided, the correct operation of annunciator under a fault condition shall be verified. (NFPA 72 Table 7-2.2 (10)) Annunciator 1st Lobby Entrance 01821497 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Device Total: 1 BuildingReports Demonstration Company 21 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 LS 02.01.34 EP 04 All other Life Safety Code fire alarm requirements related to NFPA 101-2000: 18/19.3.4 With the batteries fully charged and connected to the charger, the voltage across the batteries shall be measured with a voltmeter. Under load, the battery shall perform in accordance with the battery manufacturer's specifications. (NFPA 72 Table 7-2.2 (6d)) Battery 1st FACP Room 01821547 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Battery 1st FACP Room 01821548 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Battery 2nd Electrical Room 01821551 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Battery 2nd Electrical Room 01821552 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Battery 4th Electrical Room 01821549 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Battery 4th Electrical Room 01821550 1 10/07-P 01/07-P 04/06-P 07/08-P 10/12-P Device Total: 6 BuildingReports Demonstration Company 22 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 LS 02.01.34 EP 04 All other Life Safety Code fire alarm requirements related to NFPA 101-2000: 18/19.3.4 At a minimum, control equipment shall be tested to verify correct receipt of alarm, supervisory and trouble signals (inputs), operation of evacuation signals and auxiliary functions (outputs), circuit supervision including detection of open circuits and ground faults, and power supply supervision for detection of loss of ac power and disconnection of secondary batteries. (NFPA 72 Table 7-2.2 (1)) Power Supply 2nd Electrical Room 01821528 1 01/07-P 04/06-P 07/08-P 10/12-P Power Supply 4th Electrical Room 01821525 1 10/07-P 01/07-P 04/06-F 07/08-P 10/12-P Device Total: 2 BuildingReports Demonstration Company 23 07/22/2014

Device Type Location ScanID Address Q4/13 Q1/14 Q2/14 Q3/14 Q4/14 LS 02.01.50 EP 04 Elevators are fully equipped and protected Interface equipment connections shall be tested by operating or simulating the equipment being supervised. Signals required to be transmitted shall be verified at the control panel. (NFPA 72 Table 7-2.2 (19)) Elevator 1st Elevator Lobby 01821499 1 10/12-P Elevator 2nd Elevator Lobby 01821498 1 10/12-P Device Total: 2 BuildingReports Demonstration Company 24 07/22/2014

Auxiliary Functions Testing Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Auxiliary Functions Testing section lists each of the ancillary items, systems, and emergency equipment that are controlled by the system control unit. Items are grouped by Passed or Failed/Other. The items are listed by device type, and a check box is provided to indicate if the test conducted was simulated. Type Location Comment ScanID Elevator Passed Simulate Recall Primary 1st Elevator Lobby Passed 01821499 " Recall Alternate 2nd Elevator Lobby Passed 01821498 " Fan Shutdown Supply 1st AHU Room Unit 1A Passed 01821506 " Supply 2nd AHU Room Unit 2A Passed 01821505 " Supply 3rd AHU Room Unit 3A Passed 01821504 " Supply 4th AHU Room Unit 4A Passed 01821502 " Supply 5th AHU Room Unit 5A Passed 01821500 " Releasing Device Door Holder 1st Main Corridor Passed 01821511 " Door Holder 2nd Main Corridor Passed 01821509 " Door Holder 3rd Main Corridor Passed 01821510 " Door Holder 4th Main Corridor Passed 01821508 " Door Holder 5th Main Corridor Passed 01821507 " Smoke Detector Elevator Recall 1st Elevator Lobby Passed 01821537 " Elevator Recall 2nd Elevator Lobby Passed 01821536 " Elevator Recall 4th Elevator Lobby Passed 01821535 " Elevator Recall 5th Elevator Lobby Passed 01821534 " Elevator Recall Penthouse Elevator Machine Room Passed 01821532 " d BuildingReports Demonstration Company 25 07/22/2014

Sound and Visual Testing Generated by: BuildingReports.com Building: Sample FireScan Healthcare The Sound and Visual Testing section lists various points throughout your building where audible and visual alarm notification devices were tested. Any bar-coded audible and visual devices will appear in the Inspection and Testing section of this report. Items in this section are grouped by Passed or Failed/Other. Where specific decibel readings were recorded, they will appear under the ambient and alarm columns. The Voice column indicates whether the Sound Test Point passed the Voice Intelligibility requirements. The STI or Sound Transmission Index is shown if recorded. & Intelligibility " Location Date EC 02.03.05 EP 04 $ Comment Passed Ambie nt% db Alarm % db Annual test of visual and audible fire alarms, including speakers Voice 1st Emergency Room 10/12/14 Passed 55 79 " 0010 1st Loading Dock 10/12/14 Passed 55 89 " 0011 2nd OR Corridor 10/12/14 Passed 55 86 " 0008 2nd Pre-Op 10/12/14 Passed 55 86 " 0009 3rd West Wing 10/12/14 Passed 55 88 " 0006 3rd East Wing 10/12/14 Passed 55 78 " 0007 4th East Wing 10/12/14 Passed 55 78 " 0004 4th West Wing 10/12/14 Passed 55 78 " 0005 5th East Wing 10/12/14 Passed 55 87 " 0002 5th West Wing 10/12/14 Passed 55 77 " 0003 Penthouse Elevator Machine Room STI Soun d Test 10/12/14 Passed 55 78 " 0001 BuildingReports Demonstration Company 26 07/22/2014

Sensitivity Testing Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Sensitivity Testing section details the sensitivity test ranges and acceptable readings for each type of device. Items are grouped by Passed or Failed/Other. Normally, Devices that perform outside the acceptable range of sensitivity are listed in Failed/Other. ScanID Location Date Smoke Detector Passed Addres s Model # Range % 01821597 1st Electrical Room 10/12/14 1-M1-71 4098-9714 0.2-3.7 1.34 01821598 1st Nurse's Station 10/12/14 1-M1-72 4098-9714 0.2-3.7 1.23 01821594 2nd Mechanical Room 10/07/13 1-M1-68 4098-9714 0.2-3.7 2.16 01821591 2nd Nurse's Station 07/08/14 1-M1-66 4098-9714 0.2-3.7 1.98 01821592 2nd Electrical Room 07/08/14 1-M1-67 4098-9714 0.2-3.7 1.82 01821588 3rd Mechanical Room 07/08/14 1-M1-63 4098-9714 0.2-3.7 1.62 01821589 3rd Electrical Room 07/08/14 1-M1-64 4098-9714 0.2-3.7 1.89 01821590 3rd Nurse's Station 07/08/14 1-M1-65 4098-9714 0.2-3.7 1.78 01821565 4th Nurse's Station 10/12/14 1-M1-44 4098-9714 0.2-3.7 1.68 01821566 4th Electrical Room 10/12/14 1-M1-46 4098-9714 0.2-3.7 1.65 01821567 4th Mechanical Room 10/12/14 1-M1-45 4098-9714 0.2-3.7 1.77 01821561 5th Mechanical Room 01/07/14 1-M1-41 4098-9714 0.2-3.7 1.62 01821562 5th Electrical Room 01/07/14 1-M1-43 4098-9714 0.2-3.7 1.52 01821563 5th Nurse's Station 01/07/14 1-M1-42 4098-9714 0.2-3.7 1.48 Smoke Detector Untested 01821537 1st Elevator Lobby 12/31/69 1-M1-27 4098-9714 0.2-3.7 1.43 01821596 1st Mechanical Room 12/31/69 1-M1-69 4098-9714 0.2-3.7 1.56 01821536 2nd Elevator Lobby 12/31/69 1-M1-26 4098-9714 0.2-3.7 1.37 01821535 4th Elevator Lobby 12/31/69 1-M1-23 4098-9714 0.2-3.7 1.77 01821534 5th Elevator Lobby 12/31/69 1-M1-22 4098-9714 0.2-3.7 1.98 01821532 Penthouse Elevator Machine Room 12/31/69 1-M1-21 4098-9714 0.2-3.7 1.69 BuildingReports Demonstration Company 27 07/22/2014

Battery & Power Supply Testing Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Control & Power Testing section details the readings and measurements of batteries and power supplies used to provide power to the fire alarm and life safety systems. Items are grouped by Passed or Failed/Other. ScanID Type Location Comment Amps Volts Battery Passed 01821547 Sealed Lead Acid 1st FACP Room Passed 7.5 12 13.8 13.6 01821548 Sealed Lead Acid 1st FACP Room Passed 7.5 12 13.8 13.6 01821549 Sealed Lead Acid 4th Electrical Room Passed 7.5 12 13.8 13.5 01821550 Sealed Lead Acid 4th Electrical Room Passed 7.5 12 13.6 13.5 01821551 Sealed Lead Acid 2nd Electrical Room Passed 7.5 12 13.5 13.3 01821552 Sealed Lead Acid 2nd Electrical Room Passed 7.5 12 13.6 13.4 Power Supply 01821525 4th Electrical Room Passed 8 24 01821528 2nd Electrical Room Passed 8 24 Pre Test Post Test BuildingReports Demonstration Company 28 07/22/2014

Inventory & Warranty Report Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Inventory & Warranty Report lists each of the devices and items that are included in your Inspection Report. A complete inventory count by device type and category is provided. Items installed within the last 90 days, within the last year, and devices installed for two years or more are grouped together for easy reference. Device or Item Category % of Inventory Quantity Pull Station Initiating 13.76% 15 Smoke Detector Initiating 18.35% 20 Duct Detector Initiating 10.09% 11 Heat Detector Initiating 4.59% 5 Tamper Switch Supervisory 4.59% 5 Strobe Indicating 4.59% 5 Waterflow Switch Initiating 4.59% 5 Control Panel Control 0.92% 1 Communicator Control 0.92% 1 Annunciator Control 0.92% 1 Elevator Auxiliary 1.83% 2 Fan Shutdown Auxiliary 4.59% 5 Releasing Device Auxiliary 4.59% 5 Horn/Strobe Indicating 5.50% 6 Power Supply Control 1.83% 2 Battery Control 5.50% 6 Monitoring Monitor 2.75% 3 Type Qty Model # Description Install Date New (under 90 days) Monitoring 1 Alarm 07/14/2014 Monitoring 1 Supervisory 07/14/2014 Monitoring 1 Trouble 07/14/2014 SimplexGrinnell In Service - 90 Days - 1 Year Smoke Detector 2 4098-9714 Photoelectric 12/07/2013 Werker In Service - 2 Years to 3 Years Battery 2 WKA12-7.5F Sealed Lead Acid 08/01/2011 SimplexGrinnell In Service - 3 Years to 5 Years Pull Station 2 4099-9201 Dual Action 04/07/2010 Werker Battery 1 WKA12-7.5F Sealed Lead Acid 08/01/2009 In Service - 5 Years to 10 Years Elevator 1 Recall Alternate 04/07/2005 BuildingReports Demonstration Company 29 07/22/2014

Elevator 1 Recall Primary 04/07/2005 Fan Shutdown 3 Supply 04/07/2005 Releasing Device 5 Door Holder 04/07/2005 Potter Electric Tamper Switch 5 OSYSU-2 04/07/2005 Waterflow Switch 5 VSR-1 04/07/2005 Silent Knight Communicator 1 5704 Digital Communicator 04/07/2005 SimplexGrinnell Control Panel 1 4100U 04/07/2005 Duct Detector 11 4098-9724 Photoelectric 04/07/2005 Heat Detector 5 4098-9716 Fixed Temperature 04/07/2005 Power Supply 2 1234X 04/07/2005 Pull Station 13 4099-9201 Dual Action 04/07/2005 Smoke Detector 18 4098-9714 Photoelectric 04/07/2005 Werker Battery 1 WKA12-7.5F Sealed Lead Acid 04/07/2005 Wheelock Horn/Strobe 5 WXA-2GSX 04/07/2005 Strobe 4 WXA-3GSX 04/07/2005 Werker In Service - 10 Years to 15 Years Battery 2 WKA12-7.5F Sealed Lead Acid 08/01/2003 In Service - 15 Years to 25 Years Fan Shutdown 2 Supply 04/07/1995 Wheelock Horn/Strobe 1 WXA-2GSX 04/07/1993 Strobe 1 WXA-3GSX 04/07/1993 SimplexGrinnell In Service - 25 Years or Older Annunciator 1 456ZZ LCD Display 01/01/1988 BuildingReports Demonstration Company 30 07/22/2014

Zone Address Report Generated by: BuildingReports.com Building: Sample FireScan Healthcare Control Panel: 1 - SimplexGrinnell 4100U The Zone Address Report lists all of the devices and items that have an individual address, or are grouped together under a common zone. The device type, location, and description are included for your reference. Address Device Type Location Description ScanID Zone/Circuit: M1-02 Pull Station 3rd Stair B Dual Action 01821568 Zone/Circuit: M1-03 Tamper Switch 5th Stairwell A 01821480 Zone/Circuit: M1-04 Waterflow Switch 5th Stairwell A 01821481 Zone/Circuit: M1-05 Tamper Switch 4th Stairwell A 01821482 Zone/Circuit: M1-06 Waterflow Switch 4th Stairwell A 01821486 Zone/Circuit: M1-07 Tamper Switch 3rd Stairwell A 01821485 Zone/Circuit: M1-08 Waterflow Switch 3rd Stairwell A 01821487 Zone/Circuit: M1-09 Pull Station 1st Stair B Dual Action 01821572 Zone/Circuit: M1-10 Waterflow Switch 2nd Stairwell A 01821489 Zone/Circuit: M1-11 Tamper Switch 2nd Stairwell A 01821488 Zone/Circuit: M1-12 Waterflow Switch 1st Stairwell A 01821491 Zone/Circuit: M1-13 Tamper Switch 1st Stairwell A 01821490 Zone/Circuit: M1-20 Pull Station Penthouse Elevator Machine Room Dual Action 01821531 Zone/Circuit: M1-21 Smoke Detector Penthouse Elevator Machine Room Photoelectric 01821532 Zone/Circuit: M1-22 Smoke Detector 5th Elevator Lobby Photoelectric 01821534 Zone/Circuit: M1-23 BuildingReports Demonstration Company 31 07/22/2014

Smoke Detector 4th Elevator Lobby Photoelectric 01821535 Zone/Circuit: M1-26 Smoke Detector 2nd Elevator Lobby Photoelectric 01821536 Zone/Circuit: M1-27 Smoke Detector 1st Elevator Lobby Photoelectric 01821537 Zone/Circuit: M1-28 Duct Detector Penthouse Elevator Machine Room Photoelectric 01821538 Zone/Circuit: M1-29 Duct Detector 5th Mechanical Room - Supply Photoelectric 01821540 Zone/Circuit: M1-30 Duct Detector 5th Mechanical Room - Return Photoelectric 01821542 Zone/Circuit: M1-31 Pull Station 5th Stair A Dual Action 01821543 Zone/Circuit: M1-32 Pull Station 5th Stair B Dual Action 01821544 Zone/Circuit: M1-33 Heat Detector 5th Telephone Room Fixed Temperature 01821545 Zone/Circuit: M1-34 Duct Detector 4th Mechanical Room - Return Photoelectric 01821554 Zone/Circuit: M1-35 Duct Detector 4th Mechanical Room - Supply Photoelectric 01821555 Zone/Circuit: M1-36 Duct Detector 3rd Mechanical Room - Supply Photoelectric 01821556 Zone/Circuit: M1-37 Heat Detector 4th Telephone Room Fixed Temperature 01821557 Zone/Circuit: M1-38 Pull Station 4th Stair B Dual Action 01821558 Zone/Circuit: M1-39 Pull Station 4th Stair A Dual Action 01821559 Zone/Circuit: M1-40 Pull Station 3rd Stair A Dual Action 01821560 Zone/Circuit: M1-41 Smoke Detector 5th Mechanical Room Photoelectric 01821561 Zone/Circuit: M1-42 Smoke Detector 5th Nurse's Station Photoelectric 01821563 Zone/Circuit: M1-43 Smoke Detector 5th Electrical Room Photoelectric 01821562 Zone/Circuit: M1-44 Smoke Detector 4th Nurse's Station Photoelectric 01821565 Zone/Circuit: M1-45 Smoke Detector 4th Mechanical Room Photoelectric 01821567 BuildingReports Demonstration Company 32 07/22/2014

Zone/Circuit: M1-46 Smoke Detector 4th Electrical Room Photoelectric 01821566 Zone/Circuit: M1-47 Pull Station 2nd Stair B Dual Action 01821569 Zone/Circuit: M1-48 Pull Station 2nd Stair A Dual Action 01821570 Zone/Circuit: M1-49 Pull Station 1st Stair A Dual Action 01821571 Zone/Circuit: M1-50 Pull Station 1st Emergency Room Dual Action 01821573 Zone/Circuit: M1-51 Pull Station 1st Loading Dock Dual Action 01821574 Zone/Circuit: M1-52 Pull Station 1st Main Entrance Dual Action 01821575 Zone/Circuit: M1-53 Pull Station 1st Cafeteria Exit Dual Action 01821576 Zone/Circuit: M1-55 Heat Detector 3rd Telephone Room Fixed Temperature 01821578 Zone/Circuit: M1-56 Heat Detector 2nd Telephone Room Fixed Temperature 01821580 Zone/Circuit: M1-57 Heat Detector 1st Telephone Room Fixed Temperature 01821581 Zone/Circuit: M1-58 Duct Detector 3rd Mechanical Room - Return Photoelectric 01821583 Zone/Circuit: M1-59 Duct Detector 2nd Mechanical Room - Return Photoelectric 01821584 Zone/Circuit: M1-60 Duct Detector 1st Mechanical Room - Supply Photoelectric 01821586 Zone/Circuit: M1-61 Duct Detector 2nd Mechanical Room - Supply Photoelectric 01821585 Zone/Circuit: M1-62 Duct Detector 1st Mechanical Room - Return Photoelectric 01821587 Zone/Circuit: M1-63 Smoke Detector 3rd Mechanical Room Photoelectric 01821588 Zone/Circuit: M1-64 Smoke Detector 3rd Electrical Room Photoelectric 01821589 Zone/Circuit: M1-65 Smoke Detector 3rd Nurse's Station Photoelectric 01821590 Zone/Circuit: M1-66 Smoke Detector 2nd Nurse's Station Photoelectric 01821591 BuildingReports Demonstration Company 33 07/22/2014

Zone/Circuit: M1-67 Smoke Detector 2nd Electrical Room Photoelectric 01821592 Zone/Circuit: M1-68 Smoke Detector 2nd Mechanical Room Photoelectric 01821594 Zone/Circuit: M1-69 Smoke Detector 1st Mechanical Room Photoelectric 01821596 Zone/Circuit: M1-71 Smoke Detector 1st Electrical Room Photoelectric 01821597 Zone/Circuit: M1-72 Smoke Detector 1st Nurse's Station Photoelectric 01821598 BuildingReports Demonstration Company 34 07/22/2014