Certificate of Compliance

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Field Certification Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certification Supplement Manual

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

An Urgent Bulletin from CSA Group

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

Vanguard. Toxic & combustible gas detector

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Certificate of Compliance

Safe Operation Manual. Honeywell IQ Force Gas Detector

Annubar Flowmeter Series

INSTRUCTION & SERVICE MANUAL

Fixed Gas Detection System/Meridian CERTIFICATION

FUNCTIONAL SAFETY MANUAL

Rosemount 752 Fieldbus Remote Indicator

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Guide for hazardous areas

Inductive slot sensor

Dependable Solutions for Gas Detection

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Explosion Proof Line Powered Telephone Ringer

FLASHLIGHT ANSI STANDARDS

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Certificate of Compliance

Certificate of Compliance

FLASHLIGHT ANSI STANDARDS

standards: standards:

IECEx Certificate of Conformity

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

UL HAZARDOUS LOCATIONS SERVICES

ELECTRICAL SAFETY Information Bulletin

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

MSA Safety Solutions. for the Oil, Gas and Petrochemical Industry. Because every life has a purpose...

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Safety instructions VEGABAR 81, 82, 83, 86, 87

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Druck DPI 705/DPI 705 IS Series

Smoke detection in hazardous areas:

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

A Guide to Safe Electronic Weighing in Hazardous Locations

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Flame 2100 Flame Detection

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Continuous level measurement Ultrasonic transmitters

Certificate of Conformity

Instructions. Explosion Proof Smoke Detector U Rev: 9/

MSA Fixed Gas & Flame Detection for the Automotive Industry

Intrinsically Safe Transmitters, Option Code 2n

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

CLARITY II TURBIDIMETER

Understanding Hazardous Locations Concepts

Technical Data. General specifications. Rated operating distance s n 5 mm

SOUTH AFRICAN NATIONAL STANDARD

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

DETECT-A-FIRE Heat Detectors

Transcription:

FF0002 Certificate of Compliance Certificate: 2385571 Project 2447891 Issued to: Mine Safety Appliances 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Issued by: Jocelyn Jens Product Group Coordinator Authorized by: Lindsay Clark Operations Manager PRODUCTS CLASS 4818 03 - SIGNAL APPLIANCES - Miscellaneous - For Hazardous Locations Class I, Div. 1 & 2, Groups C and D UV/IR test lamp, Model FlameGard 5 Test Lamp, portable, battery operated (12 V). CAN/CSA-C22.2 No. 0-M91 - General Requirements - Canadian Electrical Code, Part II C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations C22.2 No. 142-M1987 - Process Control Equipment Appear on a metal nameplate secured to the enclosure via drive pins or rivets. DQD 507 Rev. 2009-09-01 Page 1

PRODUCTS CLASS 4818 03 - SIGNAL APPLIANCES -Miscellaneous - For Hazardous Locations Class I, Div. 1, Groups B, C and D; Class II, Div. 1, Groups E, F and G; Class III Model FlameGard 5 MSIR, flame detector, input rated 20 to 36 V dc, 4.4 W max, output 4-20 ma, relay contacts rated 250 V ac or 30 V dc, 8 A resistive, Enclosure Type 6P/ IP67, Ambient Temperature -40 C to +80 C. CAN/CSA-C22.2 No. 0-M91 - General Requirements Canadian Electrical Code, Part II CSA Std C22.2 No. 25-1966 - Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA-C22.2 No. 94-M91 - Special Purpose Enclosures CSA Std C22.2 No. 142-M1987 - Process Control Equipment IEC 60529, Ed. 2.1 - Degrees of Protection provided by enclosures. Adhesive nameplates are attached to a powder coated metal surface. The markings appear on a CSA accepted nameplate material manufactured by Nelson Name Plate Co., type A- Heavy Duty, Pressure sensitive '300' (9472LE adhesive), Clear Polyester, 3 mil to 4 mil. Note: Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". DQD 507 Rev. 2009-09-01 Page 2

with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. PRODUCTS CLASS 4818 03 - SIGNAL APPLIANCES -Miscellaneous - For Hazardous Locations CLASS 4818 83 - SIGNAL APPLIANCES - Miscellaneous - For Hazardous Locations - CERTIFIED TO U.S. STANDARDS Class I, Groups B, C and D; Class II, Groups E, F and G; Class III; Type 4X: Flame detectors, explosion-proof, Models FlameGard 5 UV/IR and FlameGard 5 UV/IR-H2, input rated 24 V dc, 3.6 W max, output 4-20 ma, relay contacts rated 250 V ac or 30 V dc, 8 A resistive. CAN/CSA-C22.2 No. 0-M91 - General Requirements - Canadian Electrical Code, Part II CSA Std C22.2 No. 25-1966 - Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA-C22.2 No. 94 -M91 - Special Purpose Enclosures CSA Std C22.2 No. 142-M1987 - Process Control Equipment UL 50 (11 th Ed.) - Enclosures for Electrical Equipment UL Std No. 916(4 th Ed.) - Energy Management Equipment UL Std No. 1203(4 th Ed.) - Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations The marking details appear on a metal nameplate attached to the cover by means of drive pins. Note: Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". DQD 507 Rev. 2009-09-01 Page 3

CLASS 4828 02 - SIGNAL APPLIANCES - Toxic Gas Detection Instruments - For Hazardous Locations Class I, Div. 1, Groups B, C and D; Class I, Zone 1, Group IIB+H2 Intelligent Sensor,H 2 S Gas, Model Ultima MOS-5, Stationary, Input rated 24 V dc, 7 W Max; Output rated 0-22 Ma, relay contacts rated 8 A, 250 V ac or 8 A, 30 V dc resistive, Encl. Type 4X with remote sensor. May be used with sensors: Part No 50445-1, -5, -9 or 50448-1, -5, -9 or 50454-1, -5, -9 or 50457-1, -5, -9, or 51457-1, -5, -9 or 51457-1L, -5L, -9L. Ultima MOS-5 P/N 32426-21 through -28, -37 through -44 which denotes relay options, field wiring termination, HART and Modbus combinations and material of enclosure. APPLICABLE STANDARDS CAN/CSA-C22.2 No. 0-M91 CSA Std C22.2 No.30-M1986 CAN/CSA-C22.2 No.94-M91 CSA Std C22.2 No.142-M1987 CSA Std C22.2 No.152-M1984 - General Requirements Canadian Electrical Code, Part II - Explosion-Proof Enclosures for Use in Class I Hazardous Locations - Special Purpose Enclosures - Process Control Equipment - Combustible Gas Detection Instruments Appear on a metal nameplate secured to the enclosure via screws. Note - Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". DQD 507 Rev. 2009-09-01 Page 4

CLASS 2258 02 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1: Class I, Div. 2, Groups B, C, D; Class II, Div. 2, Groups E, F, G; Class III, Div. 2: Open Path Gas Detector, Model Ultima OPIR-5, consisting of Source, P/N 329001-3 and P/N 329001-4 and Receiver, P/N 329000-a; input rated 20-36 V dc (24 V dc nominal), 12 W (Source) 10 W (Receiver), with 4-20 ma, Modbus and HART communications; Relay Contact Rated 250 V ac, 8 A resistive, 30 V dc, 8 A resistive; -60 Deg. C < Tamb. < +75 Deg. C; Temperature Code T3C; Encl. Type 4X, IP66/67. Model Code: P/N 329000-a where "a" denotes Output and Terminals; 17 through 24. CAN/CSA-C22.2 No. 0-M91 - General Requirements Canadian Electrical Code, Part II C22.2 No. 25-1966 - Enclosures for Use in Class II, Groups E, F and G Hazardous Locations C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA-C22.2 No. 94-M91 - Special Purpose Enclosures C22.2 No. 142-M1987 - Process Control Equipment C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations CAN/CSA-C22.2 No. 60529:05 - Degrees of protection provided by enclosures (IP Code) Markings are silk-screened onto a min 0.02 in. thick 316 SST nameplate, secured to the enclosure with drive pins or screws, mounted in bottomed holes. The following marking details appear: - CSA Monogram; - Manufacturer's name; - Model designation; - Date code and/or Serial number; - Electrical Input rating in volts and watts; DQD 507 Rev. 2009-09-01 Page 5

- Relay contact ratings (appears in referenced Installation Manual); - Hazardous location designations; - Temperature code rating; - Minimum and Maximum ambient temperature; - Special Purpose Enclosure Rating "Type 4X"; - Ingress Rating "IP 66/67"; - The statement" "WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT"; - The statement: "Seal all conduits within 18 inches of enclosure"; - The statement: "Use wiring suitable for 32 Deg. C above ambient" (Source); - The statement: "Use wiring suitable for 16 Deg. C above ambient" (Receiver); - The statement: "Read and understand Instruction Manual before operating or servicing". DQD 507 Rev. 2009-09-01 Page 6

CLASS 2258 02 - Process Control Equipment - For Hazardous Locations CLASS 2258 03 - Process Control Equipment - Intrinsically Safe and Non Incendive Systems - For Hazardous Locations Class I, II, III Division 1 and 2, Groups B, C, D, E, F, G; T5 UltraSonic EX-5 Ultrasonic Gas Leak Detector rated 24 V dc, 250 ma, Ambient Temperature -40 C T amb 60 C; Enclosure Type 4X, IP66. CAN/CSA Standard C22.2 No. 0-M91 - General Requirements - Canadian Electrical Code, Part II CSA Standard C22.2 No. 94.1-07 - Enclosures for Electrical Equipment, Non-Environmental Considerations CSA Standard C22.2 No. 94.2-07 - Enclosures for Electrical Equipment, Environmental Considerations CSA Standard C22.2 No. 142-M1987 - Process Control Equipment CSA Standard C22.2 No. 25-1966 - Enclosures for Use in Class II Groups E, F, and G Hazardous Locations CSA Standard C22.2 No. 30-M1986 - Explosion-Proof Enclosures for Use in Class I Hazardous Locations CAN/CSA Standard C22.2 No. 157-92 - Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations. CSA Standard C22.2 No. 213-M1987 - Non-incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations CAN/CSA- C22.2 No. 60529:05 - Degrees of Protection Provided By Enclosures (IP Code) The following markings appear on adhesive nameplate, manufactured by Nelson Name Plate Co., type A- Heavy Duty, Pressure sensitive '300' (9472LE adhesive), ClearPolyester, 3 mil to 4 mil. 1. Manufacturers name "Mine Safety Appliances", or CSA Master Contract number "252010" adjacent the CSA Mark, in lieu of manufacturers name. 2. Model designation, as specified in the PRODUCTS section, above. 3. Complete electrical rating, as specified in the PRODUCTS section, above. 4. Maximum ambient temperature rating, as specified in the PRODUCTS section, above. 5. Date code / Serial number traceable to month and year of manufacture. 6. Enclosure type ratings, as specified in the PRODUCTS section, above. DQD 507 Rev. 2009-09-01 Page 7

7. The CSA mark, as shown on the Certificate of Compliance. 8. Hazardous Location designation, as specified in the PRODUCTS section, above or equivalent 9. Temperature code, as specified in the PRODUCTS section, above. 10. The words: "WARNING EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. 11. The following words: a. "Exia". b. "Intrinsically Safe" c. WARNING: Substitution of components may impair intrinsic safety. 12. The words: "WARNING KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE" or equivalent; Note - Jurisdictions in Canada may require these markings to also be provided in French language. It is the responsibility of the manufacturer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities. It is the responsibility of the manufacturer to determine this requirement and have bilingual wording added to the "Markings". DQD 507 Rev. 2009-09-01 Page 8