EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

Similar documents
EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

Premium Desoldering station with Electric Pump Ref. DIS-D

TECHNICAL PRODUCT DATASHEET

Hot Air Station without Extractor desk Ref. JTSE-QA

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

Tokyo Gas Engineering Solutions Corporation

MultiTemp IV Thermostatic Circulator

MicroCoat Flow Guard Operating Manual

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

Micro800 Programmable Controller External AC Power Supply

Tokyo Gas Engineering Solutions Corporation

L100 Classic. Iconic 3-Way Bookshelf Loudspeaker OWNER S MANUAL

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

Installation Guide (English) for other languages see

MODEL 4312SE. 12-Inch (300mm), 3-Way Studio Monitor OWNER S MANUAL

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

Rosemount 848T High Density Temperature Measurement Family

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

Shaking Peltier Device

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

GETTING STARTED GUIDE NI NI-XNET Hardware Selectable Interface. Français Deutsch 日本語한국어简体中文. ni.com/manuals

LEVEL SENSORS & FLOAT SWITCHES

Model 685B0001C14. Electronic Vibration Switch. Installation and Operating Manual

EU Declaration of Conformity

Q-SERIES DI WATER HEATER

Ultimus I II High Precision Fluid Dispensers

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

Rosemount 2051T In-Line Pressure Transmitter

Rosemount 2051T In-line Pressure Transmitter

Ventis Slide-on Pump Field Guide Setup, Operation, and Service. Ventis 采样泵现场指南安装 使用和保养

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

PolyBox TM. Edition II. Operation Manual

Temperature Measurement Transmitters for field mounting

践行里约 +20 决议, 示范新型城镇化 : 国际人居环境范例新城倡议

Taking a Temperature

Nichia STS-DA <Cat.No > SPECIFICATIONS FOR NICHIA UV NSHU591A MODEL : NICHIA CORPORATION

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

Gas Pipeline Locating Leak detection and Safety Assessment

WPHO - LED HIGH OUTPUT WALL PACKS

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

矿用电缆 矿 用 电 缆 江苏亨通电力电缆有限公司

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

Collaborative efforts for sustainable campus 可持续校园建设多方协作机制的初探

Indoor/outdoor resistance thermometer Model TR60

Register your product and get support at 在以下网站注册并获得支持

Prospects and challenges for sustainable urbanization in China

LATEST HEAT PUMP TECHNOLOGIES IN JAPAN. Waseda University Kiyoshi Saito

A New Generation of Active Intrusion Detection System for Physical Protection

CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

Indesit,CVTAA 55 NF UK, CVTAA 55 NF UK S( CE-BCD275W-S, ) 英文说明书 版本号 REV.NO. 重量 (g) WEIGHT

KMART Corrective Action Plan

Hitachi Highly. Spezifikation Manual

Wideband Optical Couplers

BUREAU VERITAS GREATER CHINA 必维国际检验集团 大中华区 CRANE SERVICES 起重机服务

brass material mould. 500USD (2 pcs) Baby safety swab 500USD (2 pcs) Cosmetic swab brass material mould. 500USD (2 pcs) Cosmetic swab

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

Rosemount 3051L Level Transmitter

Rosemount 3051CFP Integral Orifice Flowmeter

User s Manual YTA610 and YTA710 NEPSI Certification

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

To Purchase This Item, Visit BMI Gaming (800) Super Scooper OPERATION MANUAL

Rosemount 2051 Pressure Transmitter

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

Rosemount 2051 Pressure Transmitter

Personal Care Appliances in Sweden

Rosemount 3051CFC Compact Flowmeter

Rosemount 3051 Pressure Transmitter

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

VuPoint M-Series Touchcomputer User Guide

Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

Rosemount 3051 Pressure Transmitter

Personal Care Appliances in Thailand

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

The Home Depot Quality System Audit. * Example Report * North America Latin America

Installation Instructions for the MICRO SWITCH VPX Series Valve Position Indicator for Hazardous Locations

Characteristics of nitrogen, phosphorus and potassium absorption and optimum fertilization in Sugarcane Liuqiang ZHOU, Hongwei TAN

K-Band Doppler Sensor Module

ETH1000-MKII. User manual

Boiler Safety Technical Supervision Administration Regulation

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

Model 144H. Product Data Sheet , Rev DB February Content

Always there to help you

RAS-DX18HDK/RAC-DX18HDK

Midea Vacuum Cleaner. User Manual VC-35A1Q3

OPTIBAR DP 7060 Supplementary Instructions

Rosemount 3051 Pressure Transmitter

ProcessMaster, HygienicMaster FEX300, FEX500

Beijing Urban Design Studio Summer 2008

Rosemount 3051S Series of Instrumentation

E-waste Management in China

Annubar Flowmeter Series

Transcription:

EJX / EJA-E series Change No. 15-013 For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2. 1. Applicable Users and Page IM No. Edition Page Applicable part IM 01C25B01-01E 18th 2-3 2.8 Insulation Resistance and Dielectric Strength IM 01C25C01-01E 13th 2-3 Test IM 01C25F01-01E 13th 2-3 Dielectric Strength Test IM 01C25H01-01E 12th 2-3 IM 01C25K01-01E 9th 2-3 2. Contents of Change Contents of Change (underlined) Before Change 3) Set the current limit on the dielectric strength tester to 10 ma, then turn ON the power and gradually increase the test voltage from 0 to the specified voltage. After Change 3) Set the current limit on the dielectric strength tester to 25 ma, then turn ON the power and gradually increase the test voltage from 0 to the specified voltage. Sep. 11, 2015

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters Change No. 15-015 The following explosion protected types and marine certificate types are added for EJX-A and EJA-E series. Please use this manual change with the user s manuals listed below. 1. Applicable documents IM number (Edition) IM 01C25B01-01E (18) IM 01C25C01-01E (13) IM 01C25F01-01E (13) IM 01C25H01-01E (12) IM 01C25K01-01E (9) IM 01C25R01-01E (15) Model and document name EJX110A, EJX120A, EJX130A, EJX310A, EJX430A, EJX440A, EJA110E, EJA120E, EJA130E, EJA310E, and EJA440E Differential Pressure and Pressure Transmitter EJX210A and EJA210E Flange Mounted Differential Pressure Transmitter EJX510A, EJX530A, EJX610A, EJX630A, EJA510E, and EJA530E Absolute Pressure and Gauge Pressure Transmitter EJX118A, EJX438A, EJA118E, and EJA438E Diaphragm Sealed Differential Pressure and Pressure Transmitter EJX115A and EJA115E Low Flow Transmitter EJX910A and EJX930A Multivariable Transmitter 2. New optional specifications Item Description Option code NEPSI NEPSI Flameproof Approval NF2 NEPSI Intrinsically safe Approval NS21 KOSHA KOSHA Flameproof Approval PF22 KOSHA Intrinsically safe Approval PS21 INMETRO INMETRO Flameproof Approval UF1 INMETRO Intrinsically safe Approval US1 Marine Certificate American Bureau of Shipping Type Approval WCA Det Norske Veritas Type Approval WCD Lloyd's Register of Shipping Type Approval WCL For the option codes listed below, please also read the following manuals. NF2 and NS21: IM 01C25A00-12E (Printed manual, attached to the products upon shipment.) PF22 and PS21: IM 01C25A01-01KO (Printed manual, attached to the products upon shipment.) UF1 and US1: IM 01C25A11-01P-Y (CD-ROM manual, attached to the products upon shipment.) Nov. 5, 2015

User s DPharp EJX Series, EJA-E E Series EJA Series, EJA-A Series and FVX110 電子情報報製品汚染制御管管理弁法 ( 中国版 RoHS) Change No.16-018 はじめに 本書は 中華人民共共和国国内でのみ有効です Foreword This manual is valid only in China. 产品中有有害物质或元素素的名称及含含量 有害物质 型号 部件名称 铅 汞 镉 六价铬铬 多溴联苯多溴二苯醚 (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) 壳体 EJX/EJA-E/ 膜盒组件 EJA/EJA-A Series 差压 / 压力变送器基板组件 电源连接线 壳体 FVX110 基板组件 现场总线网网段指示器 电源连接线 : 表示该部件的所所有均质材料料中的有害物质质的含量均在 GB/T26572 标准中所规规定的限量以下下 : 表示至少该部件件的某些均质质材料中的有害害物质的含量量均在 GB/T26572 标准中所规定的限量量以上 环保使用期限 : 该标识识适用于 SJ /T11364 中所述, 在中华人民共和国销售售的电子电气气产品的环保使使用期限 注 ) 该年数为 环保保使用期限, 并非产品的质量保证期期 Y June 1, 2016

DPharp EJX-A/ EJA-E/ EJX-B Series Differential Pressure and Pressure Transmitters Change No.16-036 Please use this manual change for the manuals listed below. 1. Applicable manuals IM No. (Edition) Products Page Applicable part IM 01C25A01-01E (11) EJX series, EJA-E series Differential Pressure and Pressure Transmitters Installation 31, 32 2.6 Pressure Equipment Directive (PED) IM 01C25B01-01E (18) EJX110A, EJX120A, EJX130A, EJX310A, EJX430A, EJX440A, 2-15, 2-16 2.11 Pressure Equipment Directive (PED) EJA110E, EJA120E, EJA130E, EJA310E, EJA430E, EJA440E 9-20 9.3 Optional Specifications - /PE3 IM 01C25C01-01E (13) EJX210A, EJA210E 2-16 2.11 Pressure Equipment Directive (PED) IM 01C25F01-01E (13) IM 01C25H01-01E (12) EJX510A, EJX530A, EJX610A, EJX630A, EJA510E, EJA530E EJX118A, EJX438A, EJA118E, EJA438E 2-16 2.11 Pressure Equipment Directive (PED) 9-9 9.3 Optional Specifications - /PE3 2-16 2.11 Pressure Equipment Directive (PED) IM 01C25K01-01E (9) EJX115A, EJA115E 2-16 2.11 Pressure Equipment Directive (PED) IM 01C25R01-01E (15) IM 01C25W01-01EN (1) IM 01C25W05-01EN (1) EJX910A, EJX930A EJXC50A, EJAC50E Diaphragm Seal System Digital Remote Sensor 3-10 3.11 Pressure Equipment Directive (PED) 10-12 10.3 Optional Specifications- /PE3 2-15 2.11 Pressure Equipment Directive (PED) 10-6 10.1 Standard Specifications 10-21,10-22 10.3 Optional Specifications- /PE3 IM 01C27B01-01EN(11) EJX110B, EJX310B, EJX430B 2-8 2.10 Pressure Equipment Directive (PED) 11-8 11.3 Optional Specifications - /PE3 IM 01C27C01-01EN (9) EJX210B 2-7, 2-8 2.10 Pressure Equipment Directive (PED) IM 01C27F01-01EN (9) EJX510B, EJX530B 2-8 2.10 Pressure Equipment Directive (PED) 11-4 11.3 Optional Specifications - /PE3 IM 01C27H01-01EN (9) EJX118B, EJX438B 2-7, 2-8 2.10 Pressure Equipment Directive (PED) 2. Contents of change Applicable standard notation of PED is replaced as follows. Before Change After Change 97/23/EC - 97/23/EC (until 18th July, 2016) - 2014/68/EU (from 19th July, 2016) 97/23/EC Article 3, Paragraph 3 of PED, denoted as Sound Engineering Practice (SEP) Article 3, Paragraph 3 of PED, denoted as Sound Engineering Practice (SEP). - 97/23/EC Article 3, Paragraph 3 of PED, denoted as Sound Engineering Practice (SEP) (until 18th July, 2016) - 2014/68/EU Article 4, Paragraph 3 of PED, denoted as Sound Engineering Practice (SEP) (from 19th July, 2016) YOKOGAWA July 19, 2016

User s DPharp EJX-A/ EJA-E Series S Differential Pressure and Pressure Transmitters Change No.17-007 The following information in regards of RoHS Directive is added for EJX/ EJA-E series. 1. Applicable manuals IM No.(Edition) Products IM 01C25A01-01E(12) EJX series, EJA-E series Contents of change IM 01C25B01-01E(18) EJX110A, EJX120A, EJX130A, EJX310A, EJX430A, EJX440A, EJA110E, EJA120E, EJA130E, EJA310E, EJA430E, EJA440E IM 01C25C01-01E(13) EJX210A, EJA210E EJX510A, EJX530A, EJX610A, IM 01C25F01-01E(13) EJX630A, EJA510E, EJA530E EJX118A, EJX438A, EJA118E, IM 01C25H01-01E(12) EJA438E IM 01C25K01-01E(9) EJX115A, EJA115E IM 01C25R01-01E(15) EJX910A, EJX930A EJXC50A, EJAC50E, EJXC80A, IM 01C25W01-01EN(2) EJAC80E IM 01C25W05-01EN(2) EJXC40A Add the information regarding RoHS Directivee in below. 2. Information to be added About this manual This manual and the identification tag attached on the packing box are essential parts of the product. Please keep them in a safe place for future reference. EU RoHS Directivee *1 Applicable standard: EN 50581 *1: Applicable production sites are shown s below. The condition of the RoHS compliant production sites are as follows: Japan, USA, Germany, Bahrain, India The production sites can be confirmed by the serial number shown in the frame of NO. in the name plate of the product. Serial numbers (9 letters): AAnnnnnnn AA: Identificationn code of production site Japan: Use 91 USA: Use U1 Germany: Use D1 Bahrain: Use BH India: Use Y1 Y June 1, 2017

DPharp EJX-A/EJA-E Series Differential Pressure and Pressure Transmitters Change No.17-018 Please use this manual change for the manuals as listed in below. Applicable users manual IM No. (Edition No.) Products Applicable Item IM 01C25B01-01E (18) EJ 110, EJ 120, EJ 130, (1)(4)(5)(6) EJ 310, EJ 430, EJ 440 IM 01C25C01-01E (13) EJX210A, EJA210E (1)(4)(5) IM 01C25F01-01E (13) EJ 510, EJ 530, EJ 610, EJ 630, IM 01C25H01-01E (12) EJX118A, EJX438A, EJA118E, EJA438E IM 01C25K01-01E (9) EJX115A, EJA115E IM 01C25R01-01E (15) EJX910A/EJX930A (5) IM 01C25R03-01E (12) EJX910A/EJX930A Fieldbus Communication Type (3)(5) IM 01C25T02-01E (16) DPharp Fieldbus Communication Type (2)(4)(5) IM 01C25T04-01EN (4) DPharp PROFIBUS PA Communication Type (2)(4)(5) Items to be changed 1. ATEX updates Item Applicable Part Before change After change (1) ATEX Intrinsically Safe Ex ia EN 60079-0:2009, EN 60079-11:2007, EN 60079-26:2007, EN 60079-0:2012/A11:2013, EN 60079-11:2012 EN 60079-26:2007 EN 61241-11:2006 (2) ATEX Intrinsically Safe Ex ia (Fieldbus) EN 60079-0:2009, EN 60079-11:2007/ EN 60079-11:2012, EN 60079-26:2007, EN 60079-27:2008, EN 61241-11:2006 (3) ATEX Intrinsically Safe Ex ia (EJX90A Fieldbus) EN 60079-0:2009, EN 60079-11:2012, EN 60079-26:2007 (4) ATEX Intrinsically Safe Ex ic EN 60079-0:2009 / EN 60079-0:2012, EN 60079-11:2012 EN 60079-0:2012/A11:2013, EN 60079-11:2012 August 1, 2017

(5) ATEX Flameproof Type EN 60079-0:2009, EN 60079-1:2007, EN 60079-31:2009 Type of Protection and Marking Code: Ex d IIC T6 T4 Gb Maximum Process Temperature (Tp.) for gasproof: 85 C (T6), 100 C (T5), and 120 C (T4) Maximum Surface Temperature for dust-proof: T85 C (Tamb.: 30* to 75 C, Tp.: 85 C) * 15 C when /HE is specified. Specific Conditions of Use Tag plate for flameproof type 2 EN 60079-0:2012/A11:2013, EN 60079-1:2007(:2014 from the shipment after August 1, 2017) EN 60079-31:2014 Type of Protection and Marking Code: Ex db IIC T6 T4 Gb (from the shipment after August 1, 2017) Process Temperature (Tp.) for gasproof: -50 to 85 C (T6), -50 to 100 C (T5), and -50 to 120 C (T4) Maximum Surface Temperature for dust-proof: T85 C (Tamb.: 30* to 75 C, Tp.: -30* to 85 C) * 15 C when /HE is specified. Add the following condition. Maximum Surface Temperature for dust-proof: T85 C (Tamb.: 30* to 75 C, Tp.: -30* to 85 C) * 15 C when /HE is specified. Tag plate for flameproof type See figure in below. For the shipment before July 31, 2017

3 For the shipment after August 1, 2017 2. Wetted Parts Material Code W and L Item Page Part Contents of change (6) 8-5 Reassembling the Capsule Assembly Table Add W to the wetted parts material codes H,M,T,A,D,B. Add L to the wetted parts material code S. 9-3 Maximum Pressure Limits Add W to the notes for wetted parts 9-4 Maximum Over Pressure material codes H,M,T,A,D and B 9-6, 9-12 Measurement span (capsule) Add W to the notes for the code L on the wetted parts material codes H,M,T,A,D and B. 9-18 Table 1. Add the line and notes in below. Wetted parts Cover flange and process Material code connector Capsule Capsule gasket Vent/Drain plug W # Super Duplex SST equivalent * Hastelloy C-276 PTFE Teflon Super Duplex SST ** Hastelloy C-276 L # ASTM CF-3M (Diaphragm) Teflon-coated F316L SST, 316L SST 316L SST 316L SST (Others) * Indicated material is equivalent to ASTM A995 Grade5A ** ASTM S32750 or EN10272 1.4410

DPharp EJA-E Series Differential Pressure and Pressure Transmitters Change No.18-04E Please apply a necessary change when using the users manuals as described below. 1. Applicable manuals IM No.(Edition) IM 01C25A01-01E (12) IM 01C25B01-01E (18) IM 01C25C01-01E (13) IM 01C25F01-01E (13) IM 01C25H01-01E (12) IM 01C25K01-01E (9) IM 01C25W01-01EN (2) Products EJX series, EJA-E series installation manual EJX110A, EJX120A, EJX130A, EJX310A, EJX430A, EJX440A, EJA110E, EJA120E, EJA130E, EJA310E, EJA430E, EJA440E EJX210A, EJA210E EJX510A, EJX530A, EJX610A, EJX630A, EJA510E, EJA530E EJX118A, EJX438A, EJA118E, EJA438E EJX115A, EJA115E EJXC50A, EJAC50E, EJXC80A, EJAC80E 2. Information to be added The style code of EJA-E series has been changed from S1 to S2 because of the amplifier housing color change. The contents of the above manuals are applicable for both style S1 and S2 of EJA E. When you use EJA-E series product whose style code is S2, please add S2 to the parts which describe the style code of the models EJA E in the above manuals. Before change After change Model Style Model Style EJA110E S1 EJA110E S1, S2 EJA120E S1 EJA120E S1, S2 EJA130E S1 EJA130E S1, S2 EJA310E S1 EJA310E S1, S2 EJA430E S1 EJA430E S1, S2 EJA440E S1 EJA440E S1, S2 EJA210E S1 EJA210E S1, S2 EJA510E S1 EJA510E S1, S2 EJA530E S1 EJA530E S1, S2 EJA118E S1 EJA118E S1, S2 EJA438E S1 EJA438E S1, S2 EJA115E S1 EJA115E S1, S2 The amplifier housing color is the only difference between S1 and S2. Y April 10, 2018