CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

Similar documents
CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

Wideband Optical Couplers

ETH1000-MKII. User manual

ETH1000-D. User manual

Dual SDI Optical to Electrical Converter

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

MicroCoat Flow Guard Operating Manual

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

Product Specification

TECHNICAL PRODUCT DATASHEET

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Operating Instructions

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Q-SERIES DI WATER HEATER

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

OP+DWDM8+1D OP+DWDM8+2D / OP+DWDM40 Fiber Optic DWDM Multiplexers and Demultiplexers

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Fortimo LED Line High Flux Module

LaserPlus Model LP-OA EDFA OPERATING MANUAL

Premium Desoldering station with Electric Pump Ref. DIS-D

Fortimo LED Line Gen2 Module

LASER SAFETY BARRIER

HEP Tech Co., Ltd. Company Profile

Product Specification

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0

Record of Amendments. Version Date Amendment Section/page affected

Important Safety Notice

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

G4 Pulsed Fiber Laser

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Elo Touch Solutions 15.6 Widescreen E-Series RevC All-in-One Touchcomputer

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Product Specification

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

Hot Air Station without Extractor desk Ref. JTSE-QA

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SYNRAD Laser Safety 101

MicrOTDR. Optical Fault Locator. User Manual

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Installation Manual Premier Elite Orbit QD/DT INS483-2

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Alcatel-Lucent 1850 TRANSPORT SERVICE SWITCH 320 (TSS-320) RELEASE 2.0 SAFETY GUIDE PN 8DG08136HAAA MARCH 2008 ISSUE 1

Installation Manual Premier Elite IXP-W

Installation Manual. Premier IXP-W INS538

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

IFS SFP Tranceivers User Manual

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

Bose Virtually Invisible 891 and 691 in-wall speakers

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

Rice University Laser Safety Manual

Smart BUS (S-BUS) Home Automation System Simplified Specification

43PFL6572/V7 39PFL6572/V7 32PFL6572/V7

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

The UAE RoHS regulation covers all EEE (Electrical and Electronic Equipment) as detailed in Table 1.

SF100 User Manual Version 1.0

Rosemount 752 Remote Indicator

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Four channel video link For low cost video transmission

Instruction Manual. Self-Leveling Laser Level Model No

USER GUIDE v1.4. Introduction. This document discusses the use and architecture of the OptiGrid Structured Illumination System.

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

T3/E3 Fiber Optic Line Drivers

Rosemount 705 Wireless Totalizing Transmitter

Use & Care Manual Contemporary Electric Fires

HXL. Operating instructions

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

4 Channel Contact Closure SFP DIN Fiber Link System

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Instrumentation Products and Applications

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

North Dakota State University Laser Safety

Transcription:

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L 9-channel CWDM multiplexer and demultiplexer / multi mode (-M) / -low-loss (-L) User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com

Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion USA 1600 Emerson Avenue Oxnard, CA 93033, USA Toll free North America: (866) 515-0811 Outside North America: +1 (805) 247-8560 E-mail: support@nevion.com See http://www.nevion.com/support/ for service hours for customer support globally. Revision history Current revision of this document is the uppermost in the table below. Rev. Repl. Date Sign Change description D 3 2015-05-14 MB Cover page update; DoC removed; no other changes to content 3 2 2010-12-13 AA New template. Updated China RoHS and added Declaration of Conformity. 2 1 2007-09-01 RS Complete restructuring of user manual, adding specifications for L (low loss) and M (multi mode) versions, removed description of 4-channel CWDM. Updated Materials Declaration and added EFUP. 1 0 2003-05-14 RS Corrected interconnection of sub-racks with RS-422. 0 A 2002-11-19 RS Product release. nevion.com 2

Contents Revision history... 2 1 Product overview... 4 2 Specifications... 5 2.1 Optical specifications... 5 3 Connections... 6 3.1 1-8 channel system... 6 4 9-16 channel system... 7 5 Laser safety precautions... 8 General environmental requirements for Nevion equipment... 9 Product Warranty... 10 Appendix A Materials declaration and recycling information... 11 A.1 Materials declaration...11 A.2 Recycling information...11 nevion.com 3

1 Product overview The Flashlink CWDM (Coarse Wavelength Division Multiplexing) system is based on alloptical modules for multiplexing and demultiplexing 8 CWDM wavelengths according to ITU- T G.694.2. Two sets of wavelengths, one from 1470 to 1610nm (1-8) and one from 1270 to 1410nm with an upgrade port. By use of the upgrade port, up to 16 optical signals can be run over a single fiber. The units are passive and all-optical devices, requiring no power supply or control. Any number of channels can be used to transport signals in one direction with the rest of the channels transporting signals in the other direction. The units can be cascaded through the upgrade ports in the 9-16 module. Figure 1 - CWDM-1-8/9-16 block diagram nevion.com 4

2 Specifications 2.1 Optical specifications Single mode Number of channels 8+8 Ch. 1-8: 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610nm Available wavelengths Ch. 9-16: 1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410nm Connector SC/UPC Insertion loss (end to end, including connectors) Insertion loss (end to end, incl. connectors, low loss, -L) Insertion loss (common to upgrade) Channel Spacing Passband Transmission circuit fiber Adjacent Channel Isolation Non-Adjacent Channel Isolation Directivity Connector Return loss PDL Operating Temperature Storage Temperature Optical Power 5dB max for 8 channels 7dB max for 16 channels 4dB max for 8 channels 6dB max for 16 channels 1dB max, single mode 20nm 13nm min 9/125um single mode 25dB min 35dB min 55dB min 30dB min 0.2dB max 0 40 o C -40 85 o C 250mW max Multi mode specific parameters for M versions differing from above Insertion loss (end to end, incl. connectors) Transmission circuit fiber) Directivity, -M) Connector Return loss 5.7dB max for 8 channels 50/125um 40dB min 10dB min nevion.com 5

3 Connections The CWDM filter must be mounted in a Flashlink subrack. This is done from the rear of the subrack. Do not use force when inserting the CWDM filter, once the module s upper rail aligns with the card rail in the subrack, it should slide easily into place. Lock it with 4 M2.5x8mm screws. Figure 2 - CWDM-1-8 mounted in a Flashlink subrack 3.1 1-8 channel system Connect each of the optical ports to the corresponding optical port on the receiver or transmitter that matches the signal type and wavelength. Figure 3 - Interconnection of an 8 channel system. Figure 4-8-channel CWDM filter connected to main fiber nevion.com 6

4 9-16 channel system Using the upgrade port of the CWDM-9-16 enables to have up to 16 wavelengths on a single fiber. Each set of 8 channels must first be connected like described in chapter 3.1, figure 3. Figure 5-16-channel CWDM filters connected to main fiber nevion.com 7

5 Laser safety precautions These are guidelines to limit hazards from laser exposure. All the available EO units in the Flashlink range include a laser. Therefore this note on laser safety should be read thoroughly even though there is no laser onboard this product. The lasers emit light at 1310 nm or 1550 nm. This means that the human eye cannot see the beam, and the blink reflex cannot protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time). Therefore: Be careful when connecting / disconnecting fiber pigtails (ends). Never look directly into the pigtail of the laser/fiber. Never use microscopes, magnifying glasses or eye loupes to look into a fiber end. Use laser safety goggles blocking light at 1310 nm and at 1550 nm Instruments exist to verify light output power: Power meters, IR-cards etc. Flashlink features: The FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and CFR Ch1 (1997) Part 1040.10. If the front panel is removed, the FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and class IIIb according to CFR Ch1 (1997) Part 1040.10. Maximum output power 1 : Operating wavelengths: 17 mw > 1260 nm 1 Max power is for safety analysis only and does not represent device performance. nevion.com 8

General environmental requirements for Nevion equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 50 C - Operating relative humidity range: <90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 60 C - Relative humidity range: <95% (non-condensing) nevion.com 9

Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site: www.nevion.com nevion.com 10

Appendix A Materials declaration and recycling information A.1 Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) CWDM-1-8/-9-16/1-8- L/9-16-L/1-8-M/9-16-M O O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. This is indicated by the product marking: A.2 Recycling information Nevion provides assistance to customers and recyclers through our web site http://www.nevion.com/. Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. nevion.com 11