ECV SP GUE ALO CAT ICAL TECHN

Similar documents
EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

CCHA / ECHA Cooling Only CCHBA / ECHBA Heat Pump

CHAPTER 6 CONDENSING UNITS

HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Roof top SPACE RPC 450Z R407C M011

YAH SERIES FAN COIL UNITS

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN ER-028/1/91 CONFORME NORMAS ISO 9001 CONFORM ISO 9001 NORMEN

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

EHH SERIES DRAW THROUGH FAN COILS CFM

ROOFTOP PACKAGED AIR CONDITIONERS

Roof top SPACE RPC 315Z R407C MA00

Low Flow Unit Coolers

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

SKYPAK II, 3 Ton Series, gives you a

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

E U R O V E N T CERTIFIED PERFORMANCE

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

EMI ENGINEERING SUBMITTAL

COMPACT AIR HANDLING UNIT

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

SKYPAK II, 3 Ton Series, gives you a

50YZ 40BZ/38BZ Nominal cooling capacity kw Nominal heating capacity kw

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

EMI ENGINEERING SUBMITTAL

OCTOPLUS VWF SYSTEM General Catalogue

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Modular Supply Make-Up Air Unit

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Cooling/Heat Pump Convertible Air Handlers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Cooling/Heat Pump Convertible Air Handlers

Product Specifications. Vertical Floor Consoles By First Co.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

AIR COOLED PACKAGED CHILLER

Centeral Station Air Handling Unit

AIR COOLED CONDENSERS

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Cooling/Heat Pump Convertible Air Handlers

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

CENTRAL SPLIT UNIT UNIC

Ducted Propeller. Airflow Volume

Air cooled industrial chillers

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Neosys Product catalogue

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

STAINLESS STEEL EVAPORATIVE CONDENSER

Double Skin Casing Air Handling Units

HEATING & COOLING COIL PRODUCTS

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

TOSHIBA AIR CONDITIONING

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Transcription:

TECHNICAL CATALOGUE ECV SP TAILOR MADE FOR UNITS FITTED WITH VRF SYSTEMS Models: 1001 1502 1602 2003 2303 10.16 Ref. 207609 Rev.105

CONTENT INTRODUCTION... 3 GENERAL DESCRIPTION... 3 CABINET... 3 HEAT EXCHANGERS... 3 VENTILATION... 3 POWER SUPPLY... 3 OTHER CHARACTERISTICS... 3 REGULATIONS AND CERTIFICATIONS... 3 TECHNICAL SPECIFICATIONS... 4 VERSION WITH CENTRIFUGAL FANS... 4 VERSIÓN VENTILADOR PLUG-FAN MOTOR EC... 5 DIMENSIONS... 7 ECV 1001... 7 ECV 1502 1602... 8 ECV 2003 2303... 9 10.16 Ref. 207609 Rev.105 2

INTRODUCTION GENERAL DESCRIPTION Interior evaporating units built ready to be coupled with exterior condensing units fitted with variable refrigerant flow (VRF) systems for R-410A. The air air units of the ECV SP series are delivered fully assembled and ready for immediate installation after having passed a strict verification and quality control process. The design and layout of the components offer great installation versatility and easy access to the interior of the unit for maintenance tasks. CABINET Made of high quality sheet steel covered with an aluminum, zinc and silicon alloy and finished with an electrostatic polyester powder coating polymerized in a furnace at 190 C, thus providing excellent coverage on corners and edges and ensuring optimum corrosion resistance. Inside, the unit is fitted with thermoacoustic insulation. HEAT EXCHANGERS Manufactured with comprising mechanically expanded copper tubes with specially corrugated aluminum fins to provide superior performance levels. VENTILATION Double intake centrifugal fan that allows for duct installation. Power transmission through belt and pulley systems to regulate air flow to static pressure ratio. Also available with radial Plug-Fans equipped with 7 curved, high performance blades manufactured three dimensionally with composite materials. Equipped with built-in pressure tap nozzles High air flow, high efficiency, high pressure and low noise level due to the geometry of the fan blades. POWER SUPPLY The units are designed for a 400 V / III / 50Hz power grid. For different requirements, please contact our commercial department. OTHER CHARACTERISTICS Designed with VRF capabilities (only compatible with condensing units equipped with VRF Kits). Conceived with the option of vertical or horizontal discharge. Semi-automatic purge system included in the heat exchanger. General power switch. Chassis for floor or ceiling installation. REGULATIONS AND CERTIFICATIONS ISO 9001 CERTIFICATION. HIPLUS AIRE ACONDICIONADO S.L., always striving to find customer satisfaction, has obtained the ISO 9001 Quality System referred to its production activity. This will of progress results in a continuous determination to improve quality and reliability of all our products; commercial activities, design, raw materials, production and after-sales service, are the means to reach our goal. CE MARKING: Our machines have got the CE mark, in conformity with the essential requirements of the applicable EC directives and their last modifications as well as with the national legislation of each country. 10.16 Ref. 207609 Rev.105 3

TECHNICAL SPECIFICATIONS VERSION WITH CENTRIFUGAL FANS Voltage Type ECV SP 1001 1001 1502 1502 1602 2003 2303 POWER SUPPLY V / f / Hz HEAT EXCHANGER COIL 400 / III / 50 Aluminum fins with copper tubes Number of cooling circuits 1 1 2 2 2 3 3 Refrigerant R-410A GWP 2088 Installed VRF Kit EXV-8.0 EXV-10.0 2 x EXV-8.0 EXV-8.0 + EXV-10.0 All split indoor units and the outdoor units which have FLARE valve are pre-charged with nitrogen. 2 x EXV-10.0 3x EXV-8.0 3 x EXV-10.0 Coil designation 73405 73402 73395 73406 73266 73407 73263 Volume lt 3,48 4,63 3,23 3,46 4,62 4,28 3,15 4,03 Volume min lt 2,92 3,89 2,89 2,92 3,89 3,89 2,92 3,89 Volume max lt 3,89 4,76 3,89 3,89 4,76 4,76 3,89 4,76 Type FAN Centrifugal double intake Model 12/9 G2L 12/9 G2L 12/12 G2L 12/12 G2L 12/12 G2L 15/11G2L 15/11G2L Rated air flow m 3 /h 6200 6300 9000 9000 11200 12000 13000 Available static pressure Pa 150 150 200 200 200 200 200 Motor power KW 1,1 1,1 2,2 2,2 3,0 3,0 4,0 Speed r.p.m. 886 939 907 907 1066 770 873 DIMENSIONS & WEIGHT Length mm 1700 1700 2000 2000 2000 2600 2600 Width mm 870 870 939 939 939 980 980 Height mm 650 650 747 747 747 752 752 Weight Kg 211 211 272 272 272 333 333 10.16 Ref. 207609 Rev.105 4

VERSION WITH EC MOTOR PLUG-FAN Voltage Type ECV SP 1001 1001 1502 1502 1602 2003 2303 POWER SUPPLY V / f / Hz HEAT EXCHANGER COIL 400 / III / 50 Aluminum fins with copper tubes Number of cooling circuits 1 1 2 2 2 3 3 Refrigerant R-410A GWP 2088 Installed VRF Kit EXV-8.0 EXV-10.0 2 x EXV-8.0 EXV-8.0 + EXV-10.0 All split indoor units and the outdoor units which have FLARE valve are pre-charged with nitrogen. 2 x EXV-10.0 3x EXV-8.0 3 x EXV-10.0 Coil designation 73405 73402 73395 73406 73266 73407 73263 Volume lt 3,48 4,63 3,23 3,46 4,62 4,28 3,15 Volume min lt 2,92 3,89 2,89 2,92 3,89 3,89 2,92 3,89 Volume max lt 3,89 4,76 3,89 3,89 4,76 4,76 3,89 4,76 Type FAN EC motor radial Plug-Fans Size mm 310 310 450 450 450 400 400 Number 2 2 1 1 1 2 2 Air flow m 3 /h 6200 6300 9000 9000 11200 12000 13000 Available static pressure Pa 150 150 200 200 200 200 200 Max. static pressure Pa 792 745 1084 1084 1125 1265 919 Motor power KW 1,35 1,35 3,70 3,70 3,90 3,70 3,70 Speed r.p.m. 2920 2920 3640 3640 4200 3400 3400 DIMENSIONS & WEIGHTS Length mm 1700 1700 2000 2000 2000 2600 2600 Width mm 870 870 939 939 939 980 980 Height mm 650 650 747 747 747 752 752 Weight Kg 215 215 277 277 277 333 333 10.16 Ref. 207609 Rev.105 5

ACOUSTIC LEVELS VERSION WITH CENTRIFUGAL FANS SOUND PRESSURE ECV SP 1001 1001 1502 1502 1602 2003 2303 1m 74,6 75,4 76,5 76,5 81,0 76,3 78,3 2m 68,6 69,4 70,5 70,5 75,0 70,3 72,3 5m 60,6 61,4 62,5 62,5 67,0 62,3 64,3 10m 54,6 55,4 56,5 56,5 61,0 56,3 58,3 SOUND POWER ECV SP 1001 1001 1502 1502 1602 2003 2303 63 Hz 52,1 52,9 54,0 54,0 58,5 57,8 59,8 125 Hz 60,1 60,9 63,0 63,0 67,5 65,8 67,8 250 Hz 67,1 67,9 69,0 69,0 73,5 68,8 70,8 500 Hz 73,1 73,9 76,0 76,0 80,5 75,8 77,8 1000 Hz 78,6 79,4 80,2 80,2 84,7 79,1 81,1 2000 Hz 76,6 77,4 78,3 78,3 82,8 78,1 80,1 4000 Hz 72,1 72,9 74,0 74,0 78,5 75,8 77,8 8000 Hz 64,1 64,9 65,0 65,0 69,5 67,8 69,8 Total db 82,1 82,9 84,0 84,0 88,5 83,8 85,8 VERSION WITH EC MOTOR PLUG-FAN SOUND PRESSURE ECV SP 1001 1001 1502 1502 1602 2003 2303 1m 76,5 76,5 82,5 82,5 88,5 81,5 84,5 2m 70,5 70,5 76,5 76,5 82,5 75,5 78,5 5m 62,5 62,5 68,5 68,5 74,5 67,5 70,5 10m 56,5 56,5 62,5 62,5 68,5 61,5 64,5 SOUND POWER ECV SP 1001 1001 1502 1502 1602 2003 2303 63 Hz 43,0 43,0 54,0 54,0 58,0 52,0 54,0 125 Hz 54,0 54,0 67,0 67,0 69,0 66,0 67,0 250 Hz 70,0 70,0 81,0 81,0 87,0 79,0 83,0 500 Hz 74,0 74,0 83,0 83,0 88,0 82,0 84,0 1000 Hz 80,0 80,0 86,0 86,0 91,0 85,0 87,0 2000 Hz 78,0 79,0 82,0 82,0 87,0 82,0 84,0 4000 Hz 73,0 74,0 78,0 78,0 83,0 78,0 81,0 8000 Hz 68,0 68,0 80,0 80,0 91,0 77,0 79,0 Total db 84,0 84,0 90,0 90,0 96,0 89,0 92,0 10.16 Ref. 207609 Rev.105 6

HORIZONTAL DISCHARGE LIST OF DETAILS 1. LIQUID CONNECTION 2. GAS CONNECTION 3. ELECTRICAL SUPPLY 4. AIR FILTER 5. FAN 6. CENTRIFUGAL TURBINE MOTOR 7. HEAT EXCHANGER 8. DRAINAGE 3/4 ECV - SP Please note: noise levels are referred to the fan s acoustic values in free discharge conditions. DIMENSIONS ECV 1001 10.16 Ref. 207609 Rev.105 7

HORIZONTAL DISCHARGE LIST OF DETAILS 1. GAS CONNECTION 2. LIQUID CONNECTION 3. AIR FILTER 4. ELECTRICAL SUPPLY 5. FAN 6. DRAINAGE 3/4 7. HEAT EXCHANGER ECV - SP ECV 1502 1602 10.16 Ref. 207609 Rev.105 8

LIST OF DETAILS 1. LIQUID CONNECTION 2. GAS CONNECTION 3. ELECTRICAL SUPPLY 4. AIR FILTER 5. FAN 6. CENTRIFUGAL TURBINE MOTOR 7. HEAT EXCHANGER 8. DRAINAGE 3/4 HORIZONTAL DISCHARGE ECV - SP ECV 2003 2303 10.16 Ref. 207609 Rev.105 9

10.16 Ref. 207609 Rev.105 10

10.16 Ref. 207609 Rev.105 11

HIPLUS AIRE ACONDICIONADO S.L. Masia Torrents, 2 Tel. +34 93 893 49 12 Fax. +34 93 893 96 15 08800 Vilanova i la Geltrú Barcelona, Spain www.hitecsa.com 10.16 Ref. 207609 Rev.105 12 Reservado el derecho a efectuar modificaciones sin previo aviso.