SEALED ENCLOSURE COOLING

Similar documents
ACT-HSC Series Heat Sink Coolers Sealed Enclosure Cooling Installation Guide

SEALED ENCLOSURE COOLING

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 400 Btu MODEL # S AAC-140B-4XT-EP AAC-140B-4XT-HC-EP

Quality Enclosures and cooling solutions for every environment

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

AC-046 Peltier-Thermoelectric Air Cooler

AC-162 Peltier-Thermoelectric Air Cooler

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

NOREN Products. Compact Cabinet Coolers

Thermal Management INDEX. Management. Thermal TM-1

VA G 052 S

Cooling Solutions for Mission-Critical Electronics

AIR TO AIR HEAT EXCHANGERS

Cabinet Cooler Systems

RACK-MOUNT Air Conditioners

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

30GT FLOTRONIC AIR-COOLED CHILLERS

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

GENESIS Indoor Air Conditioners

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

30GN FLOTRONIC II AIR-COOLED CHILLERS

SPECTRACOOL INDOOR/OUTDOOR

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Product Information Packet

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt

5736 N. Michigan Road Indianapolis, IN 46228

Super-Flo Low Profile Unit Cooler

5736 N. Michigan Road Indianapolis, IN 46228

Safe Enclosure Cooling

PROAIR Harsh Environment/Wash Down Air Conditioners

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

G /6000 BTU/Hr. 1172/1758 Watt

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

TEC PELTIER TEC 30X30 4MM 2.5A x30 4. TEC PELTIER TEC 30X30 3.2MM 3.9A x30 3.

FX5 Series Explosion-Proof Electric Air Heaters

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ENERGY RECOVERY HEAT PIPE HEAT EXCHANGERS

LOW PROFILE UNIT COOLER

G /6000 BTU/Hr. 1172/1758 Watt

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Top-Mount Air Conditioners

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

SPECTRACOOL Indoor & Outdoor Air Conditioners

VERTICAL FAN COIL UNITS

ClimaGuard Outdoor Heat Exchanger All Models

CR1 Series Triton Corrosion Resistant Washdown Heaters

SPECTRACOOL Indoor & Outdoor Air Conditioners

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

50TM TFF COMBINATION HEATING/COOLING UNITS

Air-Cooled Condensing Units with Compact Screw Compressors

50TM COMBINATION HEATING/COOLING UNITS

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Condensing Units CUS 15-60

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

With the world-renowned SIGMA PROFILE

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

MACH N-407 Heat Pump Air-Cooled Chiller

Product Management, Rev 3 December 2009

and Product Data VTP Selection Guide

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

revolutionary new way to cool your electrical enclosures

Enclosure Cooling, Venting, Heating & Purging Solutions. Celebrating 20 Years of Excellence

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

LUH HORIZONTAL FAN-FORCED UNIT HEATER

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Life insurance for your electronics

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

T-Series Air Conditioner T15 Model

Guide Specifications for InRow Direct Expansion

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

1 6 Top Loading Refrigeration Catalog

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Condensing Units w/ Screw Compressors

Transcription:

ADVANCED COOLING TECHNOLOGIES The Thermal Management Experts www.1-act.com SEALED ENCLOSURE COOLING ABOVE-AMBIENT AND SUB-AMBIENT COOLING

PRODUCTS TABLE OF CONTENTS HEAT SINK COOLER (ACT-HSC) HEAT EXCHANGER PAGES 3-5 Above-Ambient Heat Exchanger Economic Excellent Price vs. Performance Ratio HEAT PIPE COOLER (ACT-HPC) HEAT EXCHANGER PAGES 6-8 Above-Ambient Heat Exchanger Compact THERMOELECTRIC COOLER (ACT-TEC) AIR CONDITIONER/HEATER PAGES 9-11 Sub-Ambient Cooling Solid State Air Conditioner Compact 2

ACT-HSC HEAT SINK COOLER SERIES Passive sealed enclosure coolers consisting of two high performance, aluminum finned heat sinks bonded to the opposite sides of a common mounting plate High performance/cost ratios due to the innovative use of advanced heat transfer and manufacturing technologies Patent Pending C U L US LISTED SA4469 Thin profile, i.e., only 3.7 intrusion into the enclosure Minimum number of penetrations by cover fasteners, mounting fasteners and external fan wires Dual axial ball bearing fans for years of maintenance free operation Easy to install 1-Year Warranty (see ACT's Terms and Conditions) HSC-22 HSC-45 HSC-68 Part Number Thermal Conductance Watts/ C Thermal Capacity Watts @ 2 C T Weight (lbs.) ACT-HSC-22 22. 44 17. 12. 12. 7.88 ACT-HSC-45 45. 9 35. 22.75 12. 7.88 ACT-HSC-68 68. 1,36 51. 31.38 12. 7.88 H W D* *Extends 3.7 into the cabinet ACT-HSC SERIES FEATURES AND OPTIONS Environment Electrical Configuration UL Listing & UL Recognition NEMA Options Fans Mounting Plate HSC Housing Mounting Options Operating Temperature Expected Fan Life Indoor or Outdoor Use 115VAC, 23VAC, 12VDC, 24VDC and 48VDC AC units arrive with 6ft. long 3-pronged plug DC units arrive with bare 6 ft. long lead wires The 115VAC units received a UL listing mark. All other versions (23VAC, 12VDC, 24VDC, and 48VDC) are UL Rated/UL Recognized. 12, 3R, 4 and 4X, UL5E Certified UL Listed 6. dual ball bearing type axial fans (dry & wet locations) Aircraft quality 661 aluminum Powder coated aluminum, Optional: 316 stainless steel Top, side, front, or back Range 14 F (-1 C) to 158 F (+7 C) >1, Hours at 77 F (+25 C) 3

ACT-HSC DIMESIONS AND INSTALLATION ACT-HSC-22 See 1-ACT.com/Enclosure-Cooling for SolidWorks & DFX files for mounting and drawing SIDE 12X.221 THRU 1.88 12. 1.88 11.38 9.44 5.69 1.94.25 12. 4.19 3.7 7.89 11.38 9.44 5.69 1.94.25 ACT-HSC-45 SIDE 16X.221 THRU 1.88 21.75 2.63 21.13 19.19 14.88 1.56 6.25 1.94.25 12. 4.19 3.7 7.89 11.38 9.44 5.69 1.94.25 ACT-HSC-68 SIDE 22X.221 THRU 1.88 3.75 28.94 25.6 31.375 3.25 21.19 17.31 13.44 9.56 5.69 1.81.25 12. 4.19 3.7 7.89 11.38 9.44 5.69 1.94.25 4

ACT-HSC HEAT SINK COOLER SERIES MAXIMUM CURRENT DRAW BY MODEL Model ACT-HSC-22 ACT-HSC-45 ACT-HSC-68 NEMA Rating Voltage Maximum Operation Maximum Operation Maximum Operation Current (Amps) Current (Amps) Current (Amps) (4, 4X, 3R) 12VDC 3.6 7.2 1.8 12 12VDC 3.9 7.8 11.7 (4, 4X, 3R) 24VDC 1.64 3.28 4.92 12 24VDC 1.66 3.32 4.98 (4, 4X, 3R) 48VDC.88 1.76 2.64 12 48VDC.92 1.84 2.76 (4, 4X, 3R, 12) 115VAC.72 1.44 2.16 (4, 4X, 3R, 12) 23VAC.38.76 1.14 ACT-HSC HEAT SINK COOLER OPTIONS Filter Kit Options for Added Reliability Full Range of HSC Replacement Fans NEMA 3R Rain Hood Option NEMA 3R Rain Hood Version Available for all ACT-HSC versions 5

ACT-HPC HEAT SINK COOLER SERIES Passive sealed enclosure coolers consisting of a heat pipe heat exchanger core with advanced fin features for enhanced heat transfer performance Optimized for high performance/volume ratios. Best performance when installed vertically through the top wall (roof) of the enclosure Performance may decrease slightly when installed horizontally through a side wall of the enclosure (Contact ACT for details) HPC-8 HPC-5 Smaller opening footprint on the enclosure wall than the HSC-series Dual axial ball bearing fans for years of maintenance free operation Easy to install HPC-15 HPC-4 C U L US LISTED SA4469 1-Year Warranty (See ACT s Terms and Conditions) Part Number Thermal Conductance Watts/ C Thermal Capacity Watts @ 2 C T Weight (lbs.) H W D Insertion Depth Mounting Plate ACT-HPC-15 15. 3 7. 11.3 5.145 5. 5.6 6.75 x 6.75 ACT-HPC-4 4. 8 17. 15. 7.645 7.5 7.4 1. x 1. ACT-HPC-5 5. 1, 27. 22. 7.65 7.5 1.9 1. x 1. ACT-HPC-8 8. 1,6 37. 15. 15.15 7.5 7.4 1. x 17.5 ACT-HPC SERIES FEATURES AND OPTIONS Environment Electrical Configuration UL Listing & UL Recognition NEMA Options Fans Mounting Plate HPC Housing Mounting Options Operating Temperature Expected Fan Life Indoor or Outdoor Use 115VAC, 23VAC, 12VDC, 24VDC and 48VDC AC units arrive with 6ft. long 3-pronged plug DC units arrive with bare 6 ft. long lead wires The 115VAC units received a UL listing mark All other versions (23VAC, 12VDC, 24VDC, and 48VDC) are UL Rated/UL Recognized. 12, 3R, 4 and 4X, UL5E Certified UL Listed 4. and 6. dual ball bearing type axial fans (dry & wet locations) 34 stainless steel Powder coated aluminum, Optional: 316 stainless steel Top (best performance); side, front or back (derated performance) Range 14 F (-1 C) to 15 F (+7 C) >1, Hours at 77 F (+25 C) 6

ACT-HPC DIMESIONS AND INSTALLATION ACT-HPC-15 See 1-ACT.com/Enclosure-Cooling for SolidWorks & DFX files for mounting and drawing 5.7 11.3 TOP VIEW AIRFLOW DIRECTION 5.44 6.75 8X.221 THRU ALL 5.5 5.5 6.25 5.88 3.13 5.6 5.4 6.75.38 5.44 6.25 5.88 3.13.38 ACT-HPC-4 7.6 7.4 15. TOP VIEW AIRFLOW DIRECTION 7.9 1. 7.94 1. 12X.221 THRU ALL 8. 8. 9. 8.5 6. 3..5 7.94 9. 8.5 6. 3..5 ACT-HPC-5 TOP VIEW 12X.221 THRU ALL 8. 11.1 1.9 22. AIRFLOW DIRECTION 7.9 1. 7.94 1. 8. 9. 8.5 6. 3..5 9. 8.5 6. 3..5 7.94 ACT-HPC-8 7.6 7.4 15. TOP VIEW AIRFLOW DIRECTION 15.44 7.9 1. 18X 8..221 THRU ALL 15.5 9. 8.5 6. 3..5 15.44 17.5 16.5 13.75 11. 8.25 5.5 2.75.5 7

ACT-HPC HEAT SINK COOLER SERIES MAXIMUM CURRENT DRAW BY MODEL Model ACT-HPC-15 ACT-HPC-4 ACT-HPC-5 ACT-HPC-8 NEMA Rating Voltage Maximum Operation Current (Amps) Maximum Operation Current (Amps) Maximum Operation Current (Amps) Maximum Operation Current (Amps) (4, 4X, 3R) 12VDC 1.8 3.6 3.6 7.2 12 12VDC 1.8 3.9 3.9 7.8 (4, 4X, 3R) 24VDC.92 1.64 1.64 3.28 12 24VDC.92 1.66 1.66 3.32 (4, 4X, 3R) 48VDC.52.88.88 1.76 12 48VDC.52.92.92 1.84 (4, 4X, 3R, 12) 115VAC.6.72.72 1.44 (4, 4X, 3R, 12) 23VAC.28.38.38.76 ACT-HPC HEAT SINK COOLER OPTIONS Filter Kit Options for Added Reliability Full Range of HPC Replacement Fans NEMA 3R Rain Hoods NEMA 3R Rain Hood Version Available for all ACT-HPC versions 8

ACT-TEC THERMOELECTRIC COOLER SERIES Solid state Peltier cooling, no compressors or refrigerants Powder coated aluminum construction. 316 Stainless Steel NEMA 4x option Precise temperature control with built-in adjustable thermostat Low vibration, long life dual ball bearing fans Operating voltages of 24VDC, 115VAC, and 23VAC Optional condensate drip pan Optional heating mode 12 month warranty ACT-TEC-3 ACT-TEC-9 The ACT-TEC Thermoelectric Cooler series are compact solid state air conditioners. They cool the internal enclosure space with highly reliable Peltier cooling. The Peltier cooling cycle involves no moving parts, compressors, CFC refrigerants or circulating liquid. They feature a very long life as they are not vulnerable to refrigeration leaks. They exceeded the rugged industrial requirements of operating two four hours per day, seven days per week. In addition, ACT has chosen the industry s most durable fans with over 1, hours of continuous operation. ACT-TEC units can be used in wash-down spray-down applications or mounted directly to outdoor cabinets to operate flawlessly year around. Standard stock units are available in under a week. Dual mode operation of cooling and heating are available, as well as corrosion resistant NEMA 4X, 316 stainless steel versions. Part Number Cooling Capacity Watts/BTU s At C T ACT-TEC-9 9/3 ACT-TEC-3 3/1, Operating Voltage Ranges 24VDC, 115VAC, 23VAC 24VDC, 115VAC, 23VAC NEMA Ratings 12, 3R, 4, 4X 12, 3R, 4, 4X W D Insertion Depth Mounting Plate 4.88 7. 3.1 13. x 6. 12.5 8. 3.25 2. x 13.75 HEAT DISSIPATED (WATTS) ACT-TEC- 9 Performance Chart 14 12 1 8 6 4 4 2-5 -4-3 -2-1 +1 +2 +3 +4 +5 DELTA T ( C) ACT-TEC - 3 Performance Chart DELTA T ( C) Note: Delta T is the temperature difference between the inside enclosure temperature to the outside enclosure temperature HEAT DISSIPATED (WATTS) 4 35 3 25 2 15 1 5-5 -4-3 -2-1 +1 +2 +3 +4 +5 9

ACT-TEC THERMOELECTRIC COOLER SERIES ACT-TEC SERIES FEATURES AND OPTIONS Operating Voltages Operating Temperature Range NEMA Options Fans Mounting Plate TEC Housing Mounting Options Weight 24VDC, 115VAC and 23VAC @ 5/6Hz -1 C to 5 C, higher/ranges available on request NEMA 12, 3R, 4 and 4X applications UL Listed 4. and 6. ball bearing type axial fans Aluminum 661 powder coated Powder coated aluminum 661, Optional: 316 stainless steel on 4X versions Side mounted standard, flush mounting optional ACT-TEC-9 = 13 lbs. and ACT-TEC-3 = 5 lbs. Note: ACT-TEC standard units are configured for cooling mode and are offered in three operating voltages of 24VDC, 115VAC, or 23VAC. An additional heating mode and other operating temperatures are voltages are available upon request. ENCLOSURE COOLING ONLINE SELECTION TOOL 1-ACT.COM/ENCLOSURE-COOLING/SELECTION-TOOLS This program will assist the Enclosure Cooler design engineer in the proper selection of an enclosure cooler. The tool will select the best Enclosure Cooler proucts based on user inputs, allowing for easy online purchase. ENCLOSURE COOLING ONLINE ORDERING 1-ACT.COM/ENCLOSURE-COOLING/ORDER-ONLINE ACT offers online ordering for its line of Enclosure Cooling product. Choose your product and preferred options and conveniently pay online. 1

.21 ACT-TEC DIMENSIONS AND INSTALLATION ACT-TEC-9 See 1-ACT.com/Enclosure-Cooling for SolidWorks & DFX files for mounting and drawing 12x.221 THRU ALL 4.96 12.38 12.88 9.28 13. 11.88 11.96 6.19 3.9.21 4.88 6. 3.1 3.9 7. Optional Drain Pan Part Number: ACT-9-DP 5.38 2.69 ACT-TEC-3 2x 12.71.221 THRU ALL 19.38 16.13 12.88 2. 18.88 18.96 9.69 6.5 3.25.21 12.5 3.25 4.75 13.75 8. Optional Drain Pan Part Number: ACT-3-DP 13.13 9.81 6.56 3.31.21 11

ADVANCED COOLING TECHNOLOGIES 146 New Holland Avenue Lancaster, PA 1761, USA Phone: 717.295.661 Fax: 717.295.664 ISO 91 & AS91 Certified ITAR Registered www.1-act.com