Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Similar documents
Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard 2-channel Gas Controller MGC-03

Carbon Monoxide CO Transmitter ADT-X3-1110

Multi-Gas-Controller MGC2

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Two-Channel Gas Controller

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Sensor unit MC2 with analog output for Freon gases and refrigerants

Oxygen (O2) Single-Point Gas Detection System

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Gas Controller Module GC-06

Danfoss gas detection units

Danfoss gas detection units

CMF, CMX & CMA series

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

Carbon Monoxide Transmitter

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

Combustible Gas Detection and Control System

Danfoss gas detection unit Type GD Heavy Duty

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Danfoss gas detection Controller unit

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

Process Alarm Module RTA 421

Dräger Polytron 5700 IR Detection of flammable gases and vapours

IGD.CO.UK

Bionics Instrument. Alarm Handling. Gas Alarm Systems

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Warranty Registration

Dräger REGARD -1 Control System

APPLICATION DATA SHEET

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 7000 Fixed gas detector

Model D12-IR. Digital Gas Transmitter...

Accuracy by Design Products for the HVAC Professional

User Manual. PolyGard Single Point Controller SPC3-11XX. Single Point Gas Controller Serial Number _E_1007. May 2009

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Dräger Polytron 5100 EC Detection of toxic gases and vapors

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5720 IR Toxic Gas Detection

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

P R O D U C T D ATA S H E E T

Duct and Rough Service Carbon Monoxide Sensor

S5000 Gas Monitor. GMS5000.com

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Toxic Gas Detection. Model F12. Toxic Gas Detection

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

Ammonia Leak Detector Manual

APPLICATION DATA SHEET

Carbon Monoxide (CO) detection system

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

EXAMPLES OF HOW TO ORDER

Dräger REGARD 3900 Series Control System

Recalibrate the way you look at gas detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

EXAMPLES OF HOW TO ORDER

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

P R O D U C T D ATA S H E E T

Detection, Protection, Innovation

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Analog Room Pressure Monitor RPC Series

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

YOUR PARTNER IN FIRE & GAS DETECTION

Zareba Metro Gas Detector

C7232A,B Sensor and Controller

Dräger Polytron 8100 EC Detection of toxic gases and vapors

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

P R O D U C T D ATA S H E E T

System 57. An advanced world of intelligent gas detection system management

System 57. An advanced World of intelligent gas detection system management

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

CLEANROOM MONITOR CR3A Network - Installation Instructions

ULTIMA X5000. MSAX5000.com

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

User Manual. PolyGard Single Point Controller SPC-43-20XX. Single Point Gas Controller for Refrigerant Gases Serial Number _E_.

Chillgard Refrigerant Monitor

CN7232 Advanced Garage Ventilation Controller

3M Oldham MX 43 Controller

APPLICATION DATA SHEET

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Transcription:

Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation - Fault - Alarm 1 - Alarm 2 Keyboard 4 push-button - menu-driven Internal buzzer (02-10 Vdc or (04-20 ma output, jumper selectable NO2C standard enclosure 2 x relay alarm outputs Alarm relay 1 for NO 2 gas alarm level 1 Alarm relay 2 for NO 2 gas alarm level 2 2 x binary outputs 4-20 ma input for external CO or NO2 detector Reverse polarity protected, overload-proof and short-circuit-proof Continuous monitoring Long life expectancy Description NO2C enclosure with options orange and red warning lights Gas Central with built-in detector for Nitrogen Dioxide (NO 2, NO2C-series are used in applications such as bus- and truck garages, underground garages, road tunnels, engine repair shops, tunnels, engine test benches, shelters, mountain cavities, loading bays with dieselengined vehicles. Gas Central with built-in detector for Nitrogen Dioxide (NO 2, NO2C-series are used to warn when the quantity of harmful gases reaches an unhealthy level. NGas Central with built-in detector for Nitrogen Dioxide (NO 2, NO2C-series are used to ensure that the management of ventilation is done the best and most profitable way, ie. according to fresh air requirements. When the concentration of Nitrogen Dioxide (NO 2 becomes too high, the fans starts automatically and stops again when the Nitrogen Dioxide (NO 2 concentration has down to the predetermined level. The NO2C-series have a built-in electrochemical Nitrogen Dioxide (NO 2 sensor. Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se

Ordering Gas Central with built-in sensor / detector Type no. Range NO2C 010 NO2C 020 NO2C 030 0-10 ppm 0-20 ppm 0-30 ppm Important notes before ordering: The recommended storage life is up to 3 months unpowered for NO2C, Nitrogen Dioxide (NO 2 detectors are manufactured on request. As the storage life detectors NO2-series is up to 3 months unpowered, we want pre-payment before process the order to production, this to avoid any cancellation of order. Delivery time is normally 4 weeks after receipt of payment. Options (examples Type no. Descriptiion PR1 PR2 PR3 LFL WLO WLR DMS3 PSU 230 HEA3 BPA MOD 1 power relay, pot.free 230 Vac, 5A 2 power relays, pot.free 230 Vac, 5A 3 power relays, pot.free 230 Vac, 5A LED-flashing light in red (needs 1 open collector output Warning light orange, 24 Vdc, 5W Warning light red, 24 Vdc, 5W Duct mounting set 230 Vac Heating Battery pack Modbus RS485 RTU protocol Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se

Technical data Electrical Power consumption (without options Analog output, current or voltage selectable Alarm relay (1 Alarm relay (1 Binary output (2 Analog input Voltage for ext. analog transmitter Visualisation Display 18-28 Vac/dc, reverse polarity protected 100 ma, max. (2.5 VA 0(4-20 ma, load < 500 ohm 0(2-10 Vdc, load > 50 kohm overload-proof and short-circuit-proof 30 Vac/dc 0.5 A, potential-free, SPDT 30 Vac/dc 0.5 A, potential-free, SPNO/SPNC 30 Vdc / 0.05 A, open collector output 4-20 ma overload-proof and short-circuit-proof, input resistance 200 ohm 24 Vdc max. load 50 ma Two lines, 16 characters each Status LED (4 Normal operation- Fault- Alarm1- Alarm 2 Operation 4 push-buttons - menu-driven NO2 sensor data Sensor element Accuracy Repeatability Long term output drift Response time Sensor life expectancy Sensor coverage Mounting height Electrochemical, diffusion +/- 0.2 ppm < 2% of reading < 12% signal loss/year t90 < 25 seconds 4 years, normal operation enviroment 200 m2 to 250 m2 (recommended 0.2 above floor Buzzer (internal Acoustic pressure Frequency Gases Internal sensor External transmitter Operating environment Humidity Working temperature Storage temperature 83 db (A (distance 200 mm 2300 Hz See ordering Toxic gases, Ex gases, Freons, temperature, humidity, pressure, etc. 15 to 95 % RH non-condensing -10 C to +50 C +5 C to +30 C Pressure range Atmospheric ± 10 % Physical Enclosure plastic Flammability Enclosure colour Dimensions Weight Polycarbonate UL 94 V2 Protection class IP 65 Installation RAL 7032 (light grey 130 x 130 x 75 mm (for standard plastic Approx. 0.6 kg Wall mounting Cable entry Standard 3 x M 20 Wire connection Guidelines Warranty Screw type terminal, min. 0.25 mm2 (24 AWG max. 2.5 mm2 (14 AWG EMC Directives 2004/108/EC Low Voltage Directive 2006/95/EC EN 61010-1:2010 ANSI/UL 61010-1 CAN/CSA-C22.2 No. 61010-1 CE 1 year on material (without sensor Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se

Technical data - Options 230 Vac 90 to 250 Vac, 50/60 Hz, 0.5 A Power relay Contact rating 230 Vac, 5 A, potential-free, change-over contact Emergency power supply LED flashing light Supply duration 60 Min., maintenance-free IP65, LED, 3500 Im. Warning light 18-28 Vac/dc Consumption 45 ma, max. (1.2 VA Protection class IP 65 Warning horn Acoustic pressure Frequency Consumption 87 db (A (distance 1000 mm 3500 Hz 18-28 Vac/dc 6 ma, max. (0.15 VA External multi-sound horn Acoustic pressure 85-100 db (A (depending on sound type Sound types 28 18-28 vdc Consumption 6 ma, max. (depending on sound type Heater Temperature controlled 3 C ±2 C Ambient temperature - 30 C 18-28 Vac/dc Power consumption 0.5 A; 12 VA Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se

Wiring The alarm outputs R3 and R4 are designed as open collector outputs. Warning light / horn combination units with common ground can therefore not be connected! LED-flashing light not possible in combination with warning light. Internal buzzer is initially a standard function. if using any other function than internal buzzer on alarm output R3, then it is not possible to have internal buzzer. Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se

Energy savings in Parking Garages = Money Box There is a large number of parking garages in which the ventilation fans run continuously. Installation of Nitrogen Dioxide (NO 2 Detectors in air conditioning and ventilation systems should be high on the list of energy saving measures for any project containing an enclosed parking garage. Coverage and mounting height: Sensor coverage 200 m2 to 250 m2 (recommended Mounting height 0.2 above floor Gas Central with built-in Gas Detector NO2C-series have 4-20 ma input for external CO or NO2 detector Duct type: Gas inlet Flow speed Via a sampling pipe/ connection tube Min. 5000 m/h, Max. 20,000 m/h Duct diameter (ca. Min. 0.1 m, max. 1.0 m Length of sampling pipe Tube length Mounting 250 mm, adaptable to the duct diameter by cutting to lengths: 192, 133 or 77 mm 2 x 1000 mm Arrow at the sampling set in flow direction. Always mount in the middle of the duct. Keep a minimum distance of 1000 mm to duct bends etc. NO2C External CO or NO2 detector We reserve the right to make changes in our products without any notice which may effect the accuracy of the information contained in this leaflet. Ventilation Control Products Phone: +46-(031-811666 E-mail: info@vcp.se Sweden Fax: +46-(031-812766 Web: www.vcp.se