ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

2015 Myco Industries, Inc Fax:

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

OPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT

EG-2990i, EG-2790i EG-1690K, EG-2490K EG-2790K, EG-2990K EG-3490K, EG-3890TK EG27-i10, EG29-i10

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

PENTAX VIDEO DUODENOSCOPE ED-3490TK

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

2. Push the drain connector into the disinfectant removal port until it clicks.

OLYMPUS AMERICA, INC. ENDOSCOPE GROUP TWO CORPORATE CENTER DRIVE MELVILLE, NEW YORK TEL (631) March 3, 2003

TBJ Model SPCS B Scope Pre-Cleaning Sink. Product Specification. Product Description

Chemical Transfer Pump Tube Set and Adapter Instructions

CER-1 / CER-2 (MV-1 / MV-2) (CLM-5001X / CLM-5002VX)

INSTRUCTION MANUAL V8F145

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

G.I. Procedures. Handbook

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

When you sterilize an instrument set, you know what the standards are.

Product Catalogue 2016

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Instructions for Use: Fiberscope and LED Light Source

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

CORRECT ENDOSCOPE REPROCESSING

Cleaning & Sterilization

Instructions for Use Spinal Punches IFU

Bravo Display Warning Messages

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Enteral Pump Instructions for Use To Assemble When the low

Fujinon Medical Hygiene. Reprocessing of flexible endoscopes and endoscopic accessories.

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

EMAX 2 PLUS AND XMAX CLEANING AND STERILIZATION BASKET. Mechanical/Automated Cleaning and Sterilization Guide in a Variety of Applications

Site Requirements. MODEL 2.0 Australia

Reusable Laryngoscope Blades and Handles

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

SERRES SUCTION BAG SYSTEM MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Site Requirements ADVANTAGE PLUS

ASPIRE Laboratory Aspirator

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

Maintenance. Maintenance

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

CER-1 & CER-2 Installation & Testing Instructions

ENDOSCOPE DECONTAMINATION : Where are we now!

Quick start guide for Altrix Precision Temperature Management System

Administration of AMBISOME Using the GemStar Pump

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

R 7420 HANDLING AND DISPOSAL OF BODY WASTES AND FLUIDS

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

PrimePour TM Operation Manual

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

I.F.U Re/Processing Reusable Medical Devices

OXYGEN CONCENTRATORS Information For Our Customers

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

CLEANING INSTRUCTIONS

Manual. Reprocessing. RICHARD WOLF Heat-Sensitive Instruments. GA-J050 / en / V7.0 / PDI

PERSONAL Ultrasonic Cool Mist Humidifier

Bubble Massage Bath (Include Electronic Drain)

BAXTER: FACTOR VII 600 IU (Plasma Derived)

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

CPAP Washbasin Manual

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

Flexible endoscope automated reprocessing system

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Electric Pressure Washer

Electric Pressure Washer

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

ALLERGEN MIXING ASSISTANT

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Owner s Manual PS-200

MODEL: NSD10020 PACKING DIAGRAM \ _\ CARDBOARD (2) CORD COVERS AND PART--+- i----1 :ASTING POLYFOAM UMP. c=j-transformer AND L_J LIGHT

Start the cleaning from Left and finish at Right. Always do the floor last, start from inside and finish at doors

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

Before using your machine, you must familiarize yourself with all of its components.

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Cleaning & Care. Washing Breast Pump Parts

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

EL400 OPERATION MANUAL

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

When you successfully complete the test, you will receive a certificate and a registered key ring. We look forward to hearing from you.

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

*smith&nephew VERSAJET HYDROSURGERY SYSTEM

Torrent irrigation pump Reorder No Operating and Maintenance Manual

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

Using the Lely Robot Sampler CanWest DHI Robot Manual

14 Day Brush Cleaning Every 14 Days SS 1 B1

Transcription:

THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED STEPS OUTLINED IN THE REPROCESSING MANUAL THAT WAS INCLUDED WITH YOUR OLYMPUS EQUIPMENT WHEN PURCHASED. WHILE OLYMPUS TRAINING MAY BE USED IN SUPPORT OF A FACILITY S OVERALL COMPETENCY PROGRAM, IT SHALL NOT CONSTITUTE CERTIFICATION OF THE FACILITY S CDS PROTOCOL. OLYMPUS SHALL IN NO EVENT BE HELD RESPONSIBLE FOR A FACILITY S PROPER PERFORMANCE OF CDS PROTOCOL NOR STAYING CURRENT WITH ONGOING CDS INSTRUCTIONAL CHANGES AND CORRESPONDING TRAINING UPDATES. FACILITY OWNERS OF OLYMPUS EQUIPMENT ARE FULLY RESPONSIBLE FOR COMPLYING WITH INDUSTRY CDS STANDARDS AND MANUFACTURER S PROPER USE AND CDS INSTRUCTIONS. Attendance Sheet Facility Name: Endoscope Models: (List each model reviewed during this session) Date: Olympus In-service Training (Olympus Instructor): Print Name Signature Title OR (Authorized Facility Staff Member): Print Name Signature Title Print Name Signature Page 1 of 7

Precleaning 1. Wear appropriate personal protective equipment 2. Wipe down the insertion tube with a detergent soaked lint free cloth 3. Immerse distal tip in detergent and depress suction valve to aspirate detergent for 30 seconds 4. Remove distal tip from detergent solution and depress suction valve to aspirate air for 10 seconds 5. Turn OFF suction pump and light source 6. Attach air/water channel cleaning adapter and set the light source airflow to HIGH 7. Immerse the distal tip in clean water 8. Depress air/water channel cleaning adapter and feed water for 30 seconds 9. Release the air/water channel cleaning adapter for 10 seconds or more to let air through the channel 10. Turn OFF light source 11. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel a. Attach washing tube (MH-974) to the elevator channel plug b. Use 5 cc syringe to flush detergent solution through the elevator wire until no bubbles exit the distal tip c. Use 5 cc syringe to flush water through elevator wire channel several times d. Use 5 cc syringe to flush air through elevator wire channel until a steady stream of bubbles exits distal tip 12. Disconnect all removable and reusable parts from the endoscope 13. Confirm that water resistant cap is dry and free of debris and attach water resistant cap 14. Transport to reprocessing area in covered container Page 2 of 7

Leakage Testing 1. Fill a basin with clean water 2. Confirm that there is no water inside the leakage tester s connector cap 3. Connect leakage tester to air source and confirm that air is being emitted 4. Connect leakage tester to the endoscope and confirm bending section inflation 5. Completely immerse the endoscope in water 6. Observe for 30 seconds while angulating the bending section 7. Remove endoscope from the water and turn OFF the air source 8. Disconnect leakage tester from the air source 9. Wait 30 seconds, or until bending section contracts to its pre-expansion size 10. Disconnect leakage tester connector cap from venting connector Page 3 of 7

Manual Cleaning 1. Fill a basin with detergent solution prepared as recommended by the manufacturer 2. Completely immerse the endoscope in detergent solution. 3. Use a brush or lint-free cloth to thoroughly clean all external surface 4. For JF/TJF model duodenoscopes and other endoscope models with elevator wire channel, brush around the forceps elevator 5. Use endoscope model-specific brushes to brush channels/cylinders/ports until no visible debris remains a. Brush the suction channel in the insertion tube b. Brush the suction channel in the universal cord c. Brush the suction cylinder d. Brush the instrument channel port 6. Attach the suction cleaning adapter to the instrument channel port 7. Connect the suction tube from the suction pump to the suction connector on the endoscope 8. Immerse the distal end and weighted end of suction cleaning adapter in detergent 9. Ensure distal end of endoscope and distal end of suction cleaning adapter remain in detergent solution 10. Cover the suction cylinder and aspirate detergent solution for approximately 30 seconds 11. Turn OFF the suction source and disconnect the suction tube 12. Disconnect suction tube and the suction cleaning adapter. Reprocess them as described in Olympus instructions, Cleaning, Disinfection and Sterilization Procedures for Removable Parts and Cleaning/Reprocessing Equipment 13. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel a. Immerse the distal tip in detergent solution and raise and lower forceps elevator 3 times b. With forceps elevator raised, use 30 cc syringe to flush interior of forceps elevator with detergent solution 14. Attach the channel plug Facilities Manually Flushing With a Syringe 1. Attach the injection tube 2. Immerse the suction port of the injection tube into detergent solution prepared as recommended by the manufacturer 3. Attach a 30 cc syringe to injection tube. Inject 90 cc detergent solution into the each side of the injection tube 4. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel a. Attach the washing (MH-974) tube to elevator channel plug b. Use a 5 cc syringe to inject 15 cc of detergent solution into elevator wire channel c. Disconnect washing tube from endoscope and immerse in detergent solution 5. Detach cleaning equipment 6. Soak in detergent solution with the endoscope for time and temperature specified by the detergent manufacturer 7. Wipe down the endoscope with a lint-free cloth while the endoscope is immersed in detergent solution Page 4 of 7

Manual Cleaning (cont.) 1. Remove the endoscope and equipment from the detergent solution 2. Immerse endoscope and equipment in clean water and gently agitate to rinse 3. Reconnect the connector plug and injection tube 4. Use a 30 cc syringe to inject 90 cc of water through each side of the injection tube 5. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel: a. Attach a 5cc syringe to the washing tube (MH-974) and flush the elevator wire channel with 5cc of clean water 6. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel: b. Use a 5cc syringe to flush 10cc of air through the elevator wire channel 7. Disconnect cleaning equipment. Reprocess as described in Olympus instructions, Cleaning, Disinfection and Sterilization Procedures for Removable Parts and Cleaning/Reprocessing Equipment 8. Use a lint-free cloth to dry all external surfaces, channel plug and injection tube Facilities Using the EFP250 Endoscope Flushing Pump to Replace Manual Flushing 1. Fill two-liter container with detergent solution prepared as recommended by the manufacturer 2. Connect inlet hose to EFP250 3. Connect main channel assembly (BLUE) to EFP 250 4. Press the blue START / STOP button 5. For scopes with elevator wire a. Connect Special Channel Assembly (PURPLE) b. Press the PURPLE START / STOP button 6. Discard used detergent 7. Rinse and fill containers and endoscope basin with clean water 8. Press BLUE and PURPLE (if applicable) START / STOP button(s) 9. Place screened end of inlet hose in empty container 10. Press BLUE and PURPLE (if applicable) START / STOP button(s) 11. Use a clean, lint-free cloth to thoroughly wipe and dry the external surfaces of the endoscope and reprocessing equipment and continue reprocessing Page 5 of 7

Automated Endoscope Reprocessor (AER) High-Level Disinfection* AER type: High-level disinfectant type: 1. Test the potency of the disinfectant solution according to the manufacturer s instructions 2. Inspect the connections according to the AER manufacturer s instructions 3. Verify that the proper connector is being used for the endoscope being reprocessed 4. Attach the endoscope connectors/adapters to the AER and endoscope as per the AER manufacturer s instructions 5. Operate the AER according to the AER manufacturer s instructions 6. Ensure the endoscope is soaked in disinfectant solution according to the liquid chemical germicide manufacturer s recommendations for time and temperature 7. Remove the endoscope promptly after the AER cycle is completed 8. Perform the terminal steps that the AER does not perform (for ex: alcohol and air purge) *FOR FACILITY INTERNAL USE ONLY! Olympus personnel are unable to demonstrate use of individual manufacturer s AER Manual High-Level Disinfection 1. Fill a basin with disinfectant solution 2. Test the potency of the disinfectant solution according to the manufacturer s instructions 3. Attach the channel plug and injection tube to the endoscope 4. Completely immerse the endoscope and equipment in disinfectant solution 5. Use a 30cc syringe to inject 90cc of disinfectant into each side of the injection tube. Confirm that no bubbles exit the distal tip 6. For JF model duodenoscopes and other model endoscopes with elevator wire a. Attach the washing tube (MH-974) b. Use a 5 cc syringe to flush 10cc of disinfectant solution through the elevator wire channel via the washing tube. Confirm that no bubble exit the distal tip c. While immersed in disinfectant solution, raise the forceps elevator and flush with disinfectant using a 5 cc syringe 7. Disconnect all equipment from the endoscope 8. Remove any bubbles that adhere to the surfaces with a clean lint-free cloth 9. Soak endoscope and equipment for the time and at the temperature recommended by the disinfectant manufacturer 10. Reconnect the channel plug and injection tube to the endoscope 11. Attach 30cc syringe to each port on the injection tube and inject 90cc of air 12. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire: a. Reattach the washing tube (MH-974) b. Use 5cc syringe to flush 10cc of air through the elevator wire channel 13. Remove the endoscope and equipment from disinfectant 14. Disconnect equipment from endoscope Page 6 of 7

Rinsing 1. Fill a basin with sterile water, filtered water, or tap water 2. Completely immerse the endoscope and equipment in the water 3. Wipe all external surfaces with a lint-free cloth 4. Attach the channel plug and injection tube to the endoscope 5. Use a 30cc syringe to inject 90cc of water through each side of the injection tube 6. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel a. Attach the washing tube (MH-974) b. Use 5cc syringe to flush 15cc of water through the elevator wire channel 7. Remove the endoscope and equipment from the water 8. Cover the distal tip with a lint-free cloth 9. Use a 30cc syringe to inject 90cc of air through each side of the injection tube 10. For JF/TJF model duodenoscopes and other model endoscopes with elevator wire channel a. Attach the washing tube (MH-974) b. Use 5cc syringe to flush 15cc of air through the elevator wire channel 11. Disconnect all equipment from endoscope 12. Wipe all external surfaces with a lint-free cloth Alcohol Flush 1. Attach a reprocessed channel plug and injection tube to the endoscope 2. Immerse suction port of injection tube in 70% isopropyl or ethyl alcohol 3. Attach a 30cc syringe to each port of the injection tube and inject 90cc of alcohol 4. Remove the suction port from the alcohol 5. For JF model duodenoscopes and other model endoscopes with elevator wire a. Attach a reprocessed washing tube (MH-974) b. Use 5cc syringe to flush 10cc of alcohol through the elevator wire channel 6. Use a 30cc syringe to inject 90cc of air through each side of the injection tube 7. For JF model duodenoscopes and other model endoscopes with elevator wire channel a. Attach a reprocessed washing tube (MH-974) b. Use 5cc syringe to flush 15 cc of air through the elevator wire channel 8. Disconnect all equipment from the endoscope 9. Use sterile cotton swabs to dry the inside of the air/water and suction cylinders and instrument channel port Endoscope Storage 1. Remove all valves and removable parts from endoscope 2. Ensure that angulation locks are in the free position 3. For endoscopes with flexible adjustment mechanism, set the insertion tube to maximum flexibility 4. Store endoscope in a well-ventilated cabinet 5. Hang the endoscope so that the universal cord and insertion tube are hanging vertically and the distal tip of insertion tube is hanging freely Page 7 of 7