VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Similar documents
Refrigerated Air Dryer

Refrigerated Air Dryer

Refrigerated Air Dryer

CKD refrigerating type dryer

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Refrigeration air dryer

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Vacuum system component SELVACS

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

% by up ctoond re-heater and

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Vacuum related component model series variation

13-1. Temperature Regulator

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Multistage Ejector MODEL / Series / Product Number

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Pressure Switches Precautions 1 Be sure to read this before handling.

Hollow Fiber Membrane Filter Type Air Drier Unit Type

SAN JUAN FRESH WATER COOLING SYSTEMS

INVERTER SPLIT - TYPE

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

SpinTron 2: 2-inch High Vacuum Magnetron Sputter Source Product Installation and Use

Refrigerated Air Dryer

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions

Valve timing. Atmospheric air

PURest Air Dryer Installation and Maintenance

Monitored Pneumatic Valves On Series Ported Manifold

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Refrigerated Air Dryer

Refrigerated Air Dryer

Noiseless Heater Vacuum Relief Valve

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

INSTALLATION INSTRUCTIONS

Water separators MS-LWS, MS series

GAS CONTROL SYSTEMS SOLUTIONS OVERVIEW Manifold Systems Control Panels HP/UHP Regulators Pressure Gauges Valves&Fittings

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Instructions. Portable Absorb Phlegm. Apparatus

Powers TM Controls TH 188 Unit Mounted Thermostat

Climate Control System

Ceiling Mount Temperature Sensor

Using the DewTrak II Dew Point/ Humidity Transmitter

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

½ Monitored Pneumatic Valves On Series Ported Manifold

Heater Core Replacement

Ductless Split Air Conditioner

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Refrigerated Compressed Air Dryer

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

SPLIT WALL-MOUNTED AIR CONDITIONER

Dishwasher. Installation manual DW60M9990AP

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

UPFLOW/DOWNFLOW COILS

HEATING AND AIR CONDITIONING

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

½ Monitored Pneumatic Valve Patented Technology

Adsorption dryer PDAD. (en) Operating instructions g [ ]

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Brazed Plate Heat Exchanger Instruction Manual for BX Series

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Installation Instructions

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Waveguide Dehydrators

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Refrigerated Air Dryer Large Size Series

Dual Column Dehydrating Breather Manual

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Description. Applications

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Refrigerated Air Dryer

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Sintrol Snifter A1+ Manual. Version 1.2.2

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Transcription:

Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related products) Clean Electro pneumatic Air booster Speed control valve Silencer Check valve Joint / tube filter Suction plate Magnetic spring buffer Mechanical Electronic Contact / close contact conf. SW Air sensor Pressure SW for coolant flow sensor flow controller for air for water (Gamma) Specifications Model no. VRA2000-8 VRA2000-10 Set pressure range kpa Ambient temperature range -100 to -1 5 to 50 Balance leak flow Maximum flow rate /min (ANR) /min (ANR) 1 Note 3 200 Note 1 Port size IN/OUT 1/4 3/8 Gauge 1/8 Weight kg 0.29 Note 1: Maximum flow rate applies where the secondary side is completely closed, and the primary pressure is adjusted to -101.3kPa while the secondary pressure to -100kPa, then secondary side is fully opened. Note 2: Available only for port size Rc. Note 3: Flow rate when primary pressure is set to -95 kpa or less and secondary pressure to -45 kpa while closed. Characteristics curve Secondary pressure (kpa) 0-20 -40-60 -80-100 How to order VRA2000 0 50 100 150 200 250 Air flow rate ( /min. (ANR)) Note 1: The primary side vacuum pump is measured with using discharge rate 500 /min. Secondary pressure (kpa) 8 A -48-49 -50-51 -52 Port size GB B Option (Attachment) Symbol Descriptions A Port size 8 Rc1/4 10 Rc3/8 8G G 1/4 10G G 3/8 8N 1/4NPT 10N 3/8NPT B Option Blank G P B B3 B4 R2 Set point None Pressure gauge Note 2 Pressure switch Note 2 C type bracket L type bracket B type bracket Digital pressure sensor Note 2-100 -95-90 -85-80 -75-70 Primary pressure (kpa) Ending Applications pump pad VRA vacuum (Page 1030) VFA vacuum filter (Page 1026)

Internal structure and parts list 1 2 VRA2000 Series Internal structure and parts list Refrigerating Desiccant High polymer membrane dryer Air filter 3 Auto. drain VAC (Pump side) 4 5 6 8 SET 7 (Pad side) 9 Parts list No. Parts name 1 Cross headed truss machine screw 2 Knob assembly 3 Adjusting screw assembly 4 Adjusting spring 5 Guard assembly 6 Diaphragm assembly 7 Valve assembly Material Steel PBT Copper alloy, steel, nitrile rubber Stainless steel Aluminum alloy, PBT Aluminum alloy, steel, nitrile rubber Aluminum alloy, copper alloy, hydrogen nitrile rubber (Module unit) (Separate) Compact Precise (Related products) Clean Electro pneumatic Air booster 10 8 9 10 Body assembly Bottom spring Bottom plug assembly Aluminum alloy, stainless steel, nitrile rubber Stainless steel PBT, nitrile rubber Speed control valve Silencer Check valve Repair parts list Part name Diaphragm assembly Valve assembly Model no. VRA2000-D VRA2000-V Joint / tube filter Suction plate Magnetic spring buffer Mechanical Electronic Contact / close contact conf. SW Air sensor Pressure SW for coolant flow sensor flow controller for air for water (Gamma) Ending component

VRA2000 Series Refrigerating Desiccant High polymer membrane dryer Air filter Auto. drain Dimensions VRA2000-8/VRA2000-10 B type bracket (B4) B240 54 58 40 4-6 36 17.3 (Module unit) (Separate) Compact *50 74 86 48 Precise (Related products) Clean Electro pneumatic Air booster Speed control valve C type bracket (B) B220 54 38 69 Silencer 18 45 Check valve Joint / tube 39 7 17.3 filter 64 55 63 44 Suction plate 90 Magnetic spring buffer Mechanical Electronic Contact / close contact conf. SW Air sensor Pressure SW for coolant flow sensor flow controller VAC (Pump side) B SET (Pad side) A L type bracket (B3) B230 54 38 18 18 7 26 69 45 2.3 38 for air Hole dimension for panel mount: 38.5 for water (Gamma) Model no. VRA2000-8 VRA2000-10 A Rc1/4 Rc3/8 B Rc1/8 Rc1/8 Pressure switch (P) PPE-V01-6 15 30 15 8 Ending Pressure gauge (G) VG41D-6-P01 40.5 25 31 *13 R1/8 16 2 conductor 0.15mm 2 Lead wire 3m *12 R1/8 42 With limit mark -100 to 0kPa Main circuit Load Brown line (+) Load current + 5 to 50mA Blue line ( - ) - Power voltage 10 to 30 VDC

Dimensions Digital pressure sensor PPX-R01N-6M VRA2000 Series Dimensions/cautions Refrigerating Desiccant High polymer membrane dryer 30 30 25.5 7.5 9.5 20 PPX 1.5 42.5 R1/8 NPT1/8 20 1 Connector 12 M5 female thread M3 female thread depth 4 Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related products) Clean Electro pneumatic Air booster Speed control valve Silencer Note: Refer to page 1104 for details of digital pressure gauge PPX Series. Safety precautions WARNING 1 Use the product within specifications. 2 The product is a for vacuum. Do not use in a pressurized state. 3 Install the product avoiding direct sun lay. 4 Do not use this product in an atmosphere containing corrosive gas, chemicals, or sea water, or where these could come in contact with it, and do not use as a vacuum circuit for these substances. CAUTION 1 Install this product vertically with the knob facing upward or downward. 2 Before connecting to devices, flush piping with air to remove foreign matter. 5 Avoid installation where vibration or impact is applied. 6 Tighten pipes with the appropriate torque. 7 Limit bending moment arising from the weight of pipelines to 50 N m or less when installing. Port thread Rc1/4 Rc3/8 Tightening torque N m 6 to 8 13 to 15 3 Check that pipe thread swarf or sealant does not enter when piping or screwing in joints. 4 Check IN and OUT orientations of piping before connecting. 5 Note that this product is adjusted with constant air leakage, so vacuum pressure may not rise if the vacuum pump capacity is too small. Check valve Joint / tube filter Suction plate Magnetic spring buffer Mechanical Electronic Contact / close contact conf. SW Air sensor Pressure SW for coolant flow sensor flow controller for air for water (Gamma) Ending component