Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Similar documents
Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

Shipboard incinerators with capacities up to 4000 kw

Terminal lugs for LV power cables with aluminum conductors

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Coatings for protection of FRP structures with heavy rain erosion loads

EU RO Mutual Recognition Technical Requirements

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

To the Mutual Recognition within ship classification First Report to the European Commission and the Member States, Oct 2012

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

GROUNDING AVOIDANCE SYSTEM (GAS)

SOUND RECEPTION SYSTEM

DNVGL-CP-0398 Edition December 2015

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

DNVGL-CP-0407 Edition February 2016

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

Glass fibre rovings - Non-metallic materials

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

EU RO Mutual Recognition Technical Requirements

EC TYPE EXAMINATION CERTIFICATE

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

DNVGL-CP-0399 Edition March 2016


DNVGL-CP-0401 Edition February 2016

DNVGL-CP-0402 Edition February 2016

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

GLASS FIBRE REINFORCEMENTS

TYPE APPROVAL CERTIFICATE

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

TYPE APPROVAL CERTIFICATE

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

INTERNATIONAL STANDARD

TYPE APPROVAL CERTIFICATE

Procedure for the Approval of New Fire Detection and Alarm Technologies

LOVAG TEST INSTRUCTION IEC/EN

EC TYPE EXAMINATION (MODULE B) CERTIFICATE (EC-US MRA)

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

INTERNATIONAL STANDARD

Notified Body No.: 0098

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

INTERNATIONAL STANDARD

The PPE Directive and the PPE Regulation

AUGUST 2016 CONTENTS:

IECRE OPERATIONAL DOCUMENT

INTERNATIONAL STANDARD

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

INTERNATIONAL STANDARD

MED 96/98/EC QUALITY SYSTEM MODULE D CERTIFICATE

Commentary from a Certification Body. Mike Violette Director American Certification Body

IECEE OPERATIONAL DOCUMENT

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

INTERNATIONAL STANDARD

This document is a preview generated by EVS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

PQS Independent type-testing protocol

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

This document is a preview generated by EVS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

EC-Type Examination (Module B) Certificate. A.1/3.11 b "B" dass divisions, fire integrity

PART 3 REQUIREMENTS FOR SPRINKLER SYSTEMS and SPRINKLER INSTALLERS

INTERNATIONAL STANDARD

safety requirements are to comply with this compulsory specification twelve (12) months after the publication of this notice.

AS/NZS :2015

INTERNATIONAL STANDARD

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ei DG UV Test EC-Type Examination (Module B) Certificate A.1/3.27 a Penetrations through "B" Class divisions (electric cable transits)

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Loss Prevention Standard

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

This document is a preview generated by EVS

CEN standardization work on refrigerating systems, especially standard EN 378

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

INTERNATIONAL STANDARD

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

PQS Independent type-testing protocol

Provläsningsexemplar / Preview TECHNICAL REPORT

Transcription:

STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Circuit Breakers JANUARY 2013 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version The content of this service document is the subject of intellectual property rights reserved by Det Norske Veritas AS (DNV). The user accepts that it is prohibited by anyone else but DNV and/or its licensees to offer and/or perform classification, certification and/or verification services, including the issuance of certificates and/or declarations of conformity, wholly or partly, on the basis of and/or pursuant to this document whether free of charge or chargeable, without DNV's prior written consent. DNV is not responsible for the consequences arising from any use of this document by others. DET NORSKE VERITAS AS

FOREWORD DNV is a global provider of knowledge for managing risk. Today, safe and responsible business conduct is both a license to operate and a competitive advantage. Our core competence is to identify, assess, and advise on risk management. From our leading position in certification, classification, verification, and training, we develop and apply standards and best practices. This helps our customers safely and responsibly improve their business performance. DNV is an independent organisation with dedicated risk professionals in more than 100 countries, with the purpose of safeguarding life, property and the environment. Standards for Certification Standards for Certification (previously Certification Notes) are publications that contain principles, acceptance criteria and practical information related to the Society's consideration of objects, personnel, organisations, services and operations. Standards for Certification also apply as the basis for the issue of certificates and/or declarations that may not necessarily be related to classification. Det Norske Veritas AS January 2013 Any comments may be sent by e-mail to rules@dnv.com This service document has been prepared based on available knowledge, technology and/or information at the time of issuance of this document, and is believed to reflect the best of contemporary technology. The use of this document by others than DNV is at the user's sole risk. DNV does not accept any liability or responsibility for loss or damages resulting from any use of this document.

Standard for Certification - No. 2.9, January 2013 Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E001 Changes Page 3 CHANGES General This is a new document. The document enters into force January 2013. The remaining pages of this document are the exact text and format as agreed between the 12 EU recognised organisations. DET NORSKE VERITAS AS

1. PRODUCT DESCRIPTION... 1 1.a General description of the product... 1 1.b Application limitations... 1 1.c Intended use... 1 1.d System context... 2 2. DESIGN EVALUATION... 2 2.a Engineering evaluation requirements... 2 2.a i. Technical Requirements... 2 2.a.ii. Technical documents to be submitted... 2 2.b Type testing requirements... 3 3. PRODUCTION REQUIREMENTS... 3 3.a. General Requirements... 3 3.b Special Requirements... 3 4. MARKING REQUIREMENTS... 3 5. TYPE APPROVAL CERTIFICATE CONTENT... 3 6. APPROVAL DATE AND REVISION NUMBER... 4 7. BACKGROUND INFORMATION / REFERENCES... 4 1. PRODUCT DESCRIPTION 1.a General description of the product Description of product according to IEC IEV 441-14-20. Circuit breaker: A mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit. 1.b Application limitations Restricted to LV air circuit-breakers (ACBs) and moulded-case circuit-breaker (MCCBs) according to IEC 60947-2 were the rated voltage does not exceed 1000V a.c. (50/60 Hz) or 1500 V d.c. and without electronic devices. Onboard ships with exceptions as per SOLAS Ch. I, Reg. 3. Installation on board ships within locations with climatic, biological, chemically active, mechanically active and mechanical environmental conditions not exceeding those for which performance has been proved according to IEC 60721-3-6 (1993) + A2 (1997). 1.c Intended use Power supply system characteristics as per IEC 60092-101; 2.8. Environment category 6K4, 6B2, 6C2, 6S2 and 6M3 according to IEC 60721-3-6 (1993) + A2 (1997). Circuit breaker shall have their energy for the tripping operation stored prior to the completion of the closing operation. Page 1 of 4

Circuit breakers are to be of the trip-free type and be fitted with anti-pumping control. Circuit breakers are to be equipped with independent manual closing as per IEC 60947-2 Sub-clause 7.2.1. 1.d System context See 1.c. 2. DESIGN EVALUATION 2.a Engineering evaluation requirements 2.a i. Technical Requirements Type, ratings and characteristics of circuit breakers for intended applications to be evaluated. In general, IEC 60947 series shall be observed. 2.a.ii. Technical documents to be submitted All technical documents in English. Type test reports, product descriptions, operation manuals, assembly drawings, dimension drawings, etc. to be submitted in the English language. Prior to tests: Proposed test program and test schedule Description of the test specimens and explanation of the selected test sample(s) providing evidence that the selected sample meets the most rigorous and demanding requirements. Product descriptions, manuals, data sheets, assembly drawings, dimension drawings etc. clearly identifying the product. Complete accreditation certificate of the Test laboratory. Details of production sites. Product specification. Application, working area. Instructions on fitting, assembly and operation. QM-certificate according to ISO 9001. After completion of tests: The test report with an identification number must contain all relevant data and test results including place and date of the tests, the names of the responsible personnel carrying out the test. Type references and serial numbers of the products tested. Page 2 of 4

Test reports and test records must be signed by the personnel members in charge of the test and are to be confirmed by the R.O. by signing and marking the test report. Certificate of conformity to IEC Standards issued by one of the Certification Body under the ILAC or LOVAG or IECEE mutual recognition agreement. 2.b Type testing requirements All type tests according to IEC 60947-2 sub-clause 8.2 and 8.3 to be performed in accredited test laboratories recognized either by ILAC or LOVAG or IECEE. Above tests are to be witnessed by R.O. Test laboratory shall be authorized to conduct type tests according to the relevant IEC standards. Special test according to IEC 60947-2 sub-clause 8.5 and IEC 60947-1 Annex Q Special tests Damp heat, salt mist, vibration and shock; Category D. All tests to be performed on the agreed test samples. Type test reports, product descriptions, manuals etc. to be submitted in the English language. IEC 60947-2 Annex H, Test sequence for circuit-breakers for IT systems. 3. PRODUCTION REQUIREMENTS 3.a. General Requirements Refer to "EU RO Product Quality Assurance". 3.b Special Requirements Routine test according to IEC 60947-2 sub-clause 8.4. Production certification according to ISO 9001 by accredited certification bodies. QM/QS audit (annual) to be submitted to R.O. for review Production of the equipment is limited to those facility listed on R.O. certificate. Changes to the product will void the R.O. certification. R.O. shall be granted access to all manufacturing and testing facilities, and to be provided with all the information necessary to performance its duties. General terms and conditions of R.O. to be observed 4. MARKING REQUIREMENTS Marking as required by IEC 60947-2 (sub-clause 5.2) 5. TYPE APPROVAL CERTIFICATE CONTENT Technical data according to IEC marking. Validity according to "EU RO Product Quality Assurance, validity". R.O certificate is void if IEC standards are up-dated or withdrawn. Page 3 of 4

Reference to approved technical documents. Application and limitations. R.O. certificate remains valid until the date of validity, unless cancelled or revoked. R.O. certificate will not be valid if the applicant makes any changes or modifications to the approved product, which have not been notified to, and agreed in writing with R.O. Should the specified regulations or standards be amended during the validity of this certificate, the product(s) is/are to be re-approved prior to it/they being placed on board vessels to which the amended regulations or standards apply. 6. APPROVAL DATE AND REVISION NUMBER Revision Comment 8 July 0,0 Accepted by Advisory Board 19 Sept. 0.1 Errors corrected 7. BACKGROUND INFORMATION / REFERENCES See testing procedures. Page 4 of 4