Security systems Protecting people and property

Similar documents
Fire and Security Products and Services

Loss Prevention Standard

Loss Prevention Standard

Loss Prevention Standard

Loss Prevention Standard

Loss Prevention Standard

Services. Monitoring. t f e. w.

Standards and third party certification

LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB

Fire Performance of external thermal insulation for walls of multistorey buildings

fire resistance testing

BRE & LPCB Ruth Tucker -Passive Fire Protection

Loss Prevention Standard

t w. marlowefireandsecurity.com e.

Working in Partnership with our Customers.

Perimeter Security. Gates and fences are the first signs of a secure home and act as a good deterrent to intruders. Make sure they are in good repair.

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

BURGLAR, BALLISTIC, BLAST & FIRE RESISTANT SYSTEMS

Third Party Closed Circuit Television (CCTV) Standard- Good practice. Issue 1 Date: 29/07/2016, David Jury, BT Security

Panic and Emergency Exit Devices

ATM DEVICE THEFT & ATM GAS ATTACKS:

Third Party Certification:

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Red Book News November 2010

Fire prevention and protection

A Gateway to Safety The New Powered Gates Certification Scheme

Hardware for Sliding Doors & Folding Doors

Secured by Design Reducing crime by good design

Comprehensive Security for Banks and Credit Unions

BT SECURITY SECURITY: BEST PRACTICE GUIDE FOR NON-BT PEOPLE

Fire prevention and protection

TECHNICAL BULLETIN No: 0040

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

Brochure. Security Designed, Installed by Experts

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

DATA CENTRES & IT SECURITY. High security solutions

The Route to Third Party Certification

Loss Prevention Standards

Retail security solutions

Controlled Door Closing Devices

Council is committed to its groups working together, and to working closely with other relevant agencies, including the Queensland Police Service.

AUTOMATIC FIRE DETECTION AND ALARM SYSTEMS

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

CCTV Policy. Core values in daily life at St John Rigby College are expressed as:

Corporate Plan reference: 2. A Strong Community 2.1 Safe and healthy communities

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Ultimate Security Provider

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Electromagnetic Locking Devices

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Mechanically operated locks and locking plates

The Association for Specialist Fire Protection. Understanding Best Practice in passive fire protection

Contents EN :2006+A2:2016 (E)

FG-400:2. Product registration Anti-intruder products applicable to burglary and thefts insurance. Gyldig fra

HERE IS THE SOLUTION FOR YOUR NEEDS. Powered by BANK SECURITY SOLUTIONS

High Security. No compromise. security.gallagher.com

FIRE & SECURITY SOLUTIONS. Protecting property and life from fire, theft and vandalism

An ASSA ABLOY Group brand. ABLOY safety and security systems for MINING INDUSTRY

INTRUDER ALARM FOR BUSINESS SECURITY

Contents CONTENTS FOREWORD REGISTRATION REGISTRATION PERIOD DISCONTINUATION OF PERFORMANCE SPECIFICATIONS...

file://c:\documents and Settings\Wigstonn\Desktop\Natalie - Red Book News Files\...

Security & Monitoring Services

ETEM SECURITY. for private and professional use

Free Advice Free Quote Nationwide. Security Direct property protection. Home Security Buying Guide SECURITY DIRECT.

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Code of Practice on Closed Circuit Television (CCTV)

Ma Dejun Vice chairman of IEC/TC61 WIC 12 Nov 2014 Tokyo, Japan INTERNATIONAL ELECTROTECHNICAL COMMISSION

ROCHÉ SYSTEMS. Designer, manufacturer & installer of high quality physical security, awning & glass room solutions. COMMERCIAL

CALL FOR A FREE SURVEY

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Integrated Security and Building Automation Technology Solutions and Services. SDI Security Center of Excellence Charleston, SC

Today s world has more risk than ever. Today s G4S has more ways to protect you.

Australian/New Zealand Standard

BUSINESS PLAN. CEN/TC 388 Perimeter Protection Products and Systems EXECUTIVE SUMMARY

This document is a preview generated by EVS

a guide to the interpretation of

Type 5 Certifications:

High Speed Rail (London- West Midlands)

Entrance Control Range

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

COMPANY OVERVIEW IN PURSUIT OF OUR COMPANY GOALS WE ARE COMMITTED TO: - Continual improvement. - Trained and dedicated personnel

Black WATCH TACTICAL. Security for the future. blackwatchtactical.co.uk Tel +44 (0)

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

VISEUM UK PRESENTATION

Physical security management guidelines

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Crime Reduction Advice

WORLDWIDE CABLE EXPERTS

G4S ACADEMY THE MAMUTE SECURITY ANALYSIS MODEL

A GUIDE FOR SELECTING FLAT ENTRANCE DOORSETS. A publication for housing associations, landlords, building owners and local authorities in England

White Paper. Effective and Energy Efficient Access Control in Commercial Buildings. The global leader in door opening solutions

Australian Standard. Closed circuit television (CCTV) Part 4: Remote video AS AS

Health and Safety Policy Manual Arson Prevention Policy HS 010

A guide to the changes between BS 8418:2010 and BS 8418:2015

Security in museums and galleries: advice for architects and planners

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Safety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance)

Transcription:

www.bregroup.com Security systems Protecting people and property

2 The correct specification of security products and systems is critical in protecting people and property from losses associated with crime and terrorism Overview BRE Global has been setting standards for loss prevention since the 1800 s, and its standards and certification schemes for security products are recognised across the world. That recognition is testimony to the extremely thorough technical evaluation work and rigorous quality audit processes undertaken by BRE Global to ensure the security products it tests and certifies deliver proven levels of protection. BRE Global works closely with government, police, insurers, risk consultants and architects to develop standards and certification schemes which ensure security equipment and services deliver the levels of performance required to protect against criminal and terrorist threats. Certification to BRE Global s Loss Prevention Standards (LPSs) is specified across multiple sectors, including: education, finance, healthcare, manufacturing, the public sector, residential, retail and utilities. The standards are also specified for the protection of critical infrastructure where delivery of specified levels of security performance is critical. LPCB is the certification brand owned by BRE Global for fire and security related certification so you will often see LPCB certified and LPCB s standards. Setting high standards of security The Loss Prevention Standards developed by BRE Global address risks not otherwise covered by existing national and international standards and codes. They are drafted by teams of experts, and are reviewed and endorsed by independent stakeholders representing major interest groups. BRE Global s broad range of standards are designed to simulate a variety of circumstances. This could be the likely length of attack, the tools or methods used, or even the likelihood of a stealth attack. Whatever the situation, an effective physical security solution should deter or delay an attacker and should be complemented by a suitable means of detection and an appropriate response. Loss Prevention Standards can be viewed at www.redbooklive.com. Detection Electronic security Response Delay Physical security

3 Independent testing BRE Global is a fully equipped UKAS accredited testing laboratory No. 0578. BRE Global can also arrange for testing to be conducted at manufacturers premises, whether in the UK or abroad. This has many advantages to manufacturers including reduced costs and timescales. Certification of effective security In order to ensure the LPCB certification mark is, and continues to be, a mark of excellence in loss prevention; the products that bear the LPCB certification mark and the companies that deliver those products onto the market have to complete a thorough evaluation process. That process focuses on the critical factors that combine to deliver the product s performance: design, use and quality control. It also involves thorough processes to ensure the quality of testing conducted in support of the product s certification, whether conducted by BRE Global s own expert team of test engineers or by other independent laboratories recognised by BRE Global. Installation and use Design and construction Quality of manufacture Product performance A product s design, the quality of how it is constructed, and the manner in which it is installed and used contribute to its performance in use. These factors therefore form an integral part of the evaluation and certification process. Why have a product certified? In today s society protecting people, property and the environment is ever more important. The LPCB certification mark reassures purchasing customers that certified systems have achieved a defined performance level and will safeguard individuals, communities and buildings against risk. Manufacturers benefit from certification by being able to positively distinguish their products from the competition in a way that purchasers will recognise, accept, and increasingly insist upon. When a product is certified by BRE Global it is immediately listed in the Red Book, a source used by specifiers and purchasers in selecting security components. Specifiers and designers also benefit by being able to cut through the confusion of claims of compliance, as the LPCB certification mark provides evidence that a product has met a given standard. Red Book Once BRE Global is satisfied that a product or service meets the required standard, it is listed in the Red Book. Red Book listings can be downloaded free of charge from www.redbooklive.com. The Red Book therefore helps to combat false or misleading claims of product certification. Where such claims refer to LPCB schemes or services, BRE Global actively investigates them and takes action as necessary. www.redbooklive.com The evaluation activities BRE Global undertake, not only before issuing an LPCB certificate but while that certificate remains in force, help to ensure the factors that affect product performance are suitably robust and managed effectively. In turn these activities help to ensure the products BRE Global certify meet, and continue to meet, the exacting standards to which they are certified.

4 Security Systems LPCB certification ensures that security products provide the reliable delay and means of detection required to protect against intrusion An effective security strategy concentrates not only on one particular element, but addresses each and every layer applicable to the scenario. BRE Global s Loss Prevention Standards (LPS), product certification and Red Book listings cover a broad range of potential solutions, including: Access control systems Access covers and hatches Alarm receiving centres Alarm transmission systems Asset marking systems Bicycle storage Biometrics Cabinets and cages Cladding and roof systems Curtain walling systems Cylinders Doors Electronic locks Enclosures and kiosks Fences and walls Gates and turnstiles Glazing Grilles and barsets Intruder detection systems & components Locks and padlocks RFID Safes and strongrooms Secure asset registers Sheds and tool stores Shutters Specialist security devices Supervised premises transceivers Theft resistant assets Vehicle barriers Windows and roof lights LPCB certifies security equipment to various British and European standards, as well as its own world-renowned Loss Prevention Standards (LPS). These allow specifiers to select appropriate products for each security layer, from the perimeter right through to the asset itself. Intruder-resistant products LPS 1175 LPS 2081 PAS 24 EN 1627 Glazing LPS 1270 EN 356 Perimeter Facade Internals Alarm receiving and alarm transmission LPS 1020 LPS 1277 EN 50136 Asset marking LPS 1224 LPS 1225 Safes and strongrooms LPS 1183 EN 1143 EN 14450 Locking hardware LPS 1654 LPS 1242 Blast protection EN 13123-1 ISO 16933 EN 13123-2 ISO 16934 EN 13541 Intruder & hold-up alarm systems EN 50131 Asset Access control systems EN 60839-11-1 Information technology LPS 1214 Vehicle barriers PAS 68 LPS 1175 IWA14 Theft resistant consumer electronics LPS 1650 Ballistic protection EN 1063 EN 1522 ISO 16935

5 Building and perimeter LPS 1175 Requirements and testing procedures for the LPCB certification and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers. LPS 1175 covers the broadest scope of physical security products and services of any publicly available standard in the world. LPS 1175 is the result of many years of work by LPCB, Government, Insurers and Police, and has rapidly become a core element of physical security specification across many sectors. The standard comprises a number of security ratings with test requirements of ascending intensity. These are measured in terms of attack tools and time available to the attacker, and enables specifiers to select products according to the risks that they and their property face. LPS 1175 can be used in a range of applications, from residential right through to critical infrastructure projects. Level of risk High risk Low risk LPS 2081 Security rating to LPS 1175 SR8 SR6 & 7 SR4 & 5 SR3 SR1 & 2 Resistance provided Products provide resistance to extreme means of attempted forced entry into higher value areas. Products provide high levels of resistance to professional means of attempted forced entry into higher value storage areas using a wide range of tools including mains powered tools. Products resist experienced attempts at forced entry using a wide range of tools including battery powered tools lasting up to 10 minutes depending on the security rating sought. Products provide moderate resistance to determined attempts of force entry using a range of techniques including those that involve creation of noise. Products provide the minimum levels of recognised resistance to opportunist attempts at forced entry using a range of techniques including those that create noise such as those involving breaking glass. Requirements and testing procedures for the LPCB certification and listing of building components, strongpoints, security enclosures and free standing barriers offering resistance to intruders attempting to use stealth to gain entry. While LPS 2081 covers the same scope of products as LPS 1175, it focuses on prevention of a very different threat, i.e. intruders using stealth. Products certified to the standard therefore suit environments where intruders will avoid making noise when attempting to gain access. EN 1627 Pedestrian doorsets, windows, curtain walling, grilles and shutters. Burglar resistance. Requirements and classification. This standard classifies a product s resistance to tiered levels (resistance classes). The lower classes of EN 1627 are aimed at attacks by criminals using stealth to gain access, rather than the higher levels of attack covered by LPS 1175. Certification to EN 1627 can be used to demonstrate part-compliance with the requirements of PAS 24. PAS 24 Enhanced security performance requirements for doorsets and windows in the UK. This domestic security standard includes doors (hinged, sliding, bi-folding) and windows (casement, tilt-turn, sliding sash). PAS 24 is a mix of mechanical loading and manual intervention tests. Doors and windows certified by LPCB to PAS 24, LPS 1175 or LPS 2081 are accepted by the police for use in Secured by Design projects and meet the requirements of Approved Document Q. Glazing LPS 1270 Requirements and testing procedures for the LPCB certification and listing of intruder resistant security glazing units. LPS 1270 classifies glazing s resistance to forced entry to the same levels as specified in LPS 1175. The classification is represented by 3 digits; these signify the glazing s resistance to local penetration, hand hole access, and complete access. Digit Type Description 1st 2nd 3rd Local penetration Hand hole access Complete access Represents glazing s likely resistance to creation of a hole through which a piece of wire, screwdriver, lever or other such device can be passed. Such attacks may be attempted by intruders wishing to operate a panic bar, emergency lever handle or other. Represents glazing s likely resistance to creation of a hand hole. Such attacks may be attempted by intruders wishing to: Operate a thumbturn to release a lock fitted to a certified product. Retrieve an item from the protected side of the glass. Confirms the glazing s resistance to creation of a hole through which an elliptical test block measuring 400 mm by 225 mm may be passed. This replicates the size of a hole a person may be able to pass through and reflects the test block defined in LPS 1175.

6 Ballistic and blast protection LPCB offers independent third-party certification of products offering protection to:- EN 1063 Glass in building Security glazing Testing and classification of resistance against bullet attack EN 1522 Windows, doors, shutters and blinds Bullet resistance Requirements and classification EN 13123-1 Windows, doors and shutters Explosion resistance Requirements and classification Part 1: Shock tube EN 13123-2 Windows, doors and shutters Explosion resistance Requirements and classification Part 2: Range test EN 13541 Glass in building Security glazing Test and classification of resistance against explosion pressure ISO 16933 Glass in building Explosion resistant security glazing Test and classification for arena air blast loading ISO 16934 Glass in building Explosion resistant security glazing Test and classification for shock tube loading ISO 16935 Glass in building Bullet-resistant security glazing Test and classification Hostile vehicle mitigation PAS 68 and IWA14 Impact test specifications for vehicle security barriers. LPCB offers independent third-party certification of vehicle mitigation equipment. This ensures the products supplied by manufacturers deliver the levels of performance claimed and that the performance demonstrated during testing is replicated by the products delivered to site. LPCB can also undertake testing of vehicle barriers together with ancillary equipment, such as hydraulic motor housing, to LPS 1175. This demonstrates their resistance to manual attacks aimed at compromising the barrier s ability to prevent the passage of hostile vehicles. Safes, strongrooms & security cabinets EN 1143 Secure storage units. Requirements, classification and methods of test for resistance to burglary. Safes, ATM safes, strongroom doors and strongrooms. LPCB provides testing and certification to the widely-specified EN 1143 standard, which can be applied to safes, strongrooms and ATM safes. The standard comprises a series of grades, with the designated grade indicating the value of contents acceptable to insurers. LPCB also provide testing and certification of security cabinets to LPS 1175 and EN 14450, both of which are recognised by Insurers and Police. Asset marking and databases LPS 1225 Requirements for the LPCB approval and listing of asset marking systems. LPS 1225 specifies the requirements for the composition and performance of an asset marking system such that, when used according to the manufacturer s instructions, the asset marking device may both: Enable the marked asset to be traced back to the legal owner via a secure database register (see below), and Act as a theft deterrent in the first instance by virtue of known existence. LPS 1224 Requirements for secure database registers. LPS 1224 sets out the requirements for secure databases on which information may be stored pertaining to asset marked products. Installation, service and maintenance It is critical that doors and shutters are appropriately installed and maintained, as poor installation can undermine a product s security performance. LPCB offers the following schemes relating to installation, inspection, service and maintenance: LPS 1197: Requirements for companies inspecting, repairing and maintaining security doors, doorsets and shutters. LPS 1271: Requirements for LPCB approval and listing of companies installing fire and security doors, doorsets and shutters and active smoke/fire barriers.

7 Alarm transmission systems Locking hardware LPCB offers certification schemes for hardware including locksets, exit devices, padlocks and cylinders. LPS 1654 Requirements and testing procedures for the LPCB approval and listing of padlocks. LPS 1654 specifies the requirements for resistance to manual attack for padlocks. The standard shares the same security ratings as LPS 1175, allowing specifiers to determine the suitability of padlocks for use on other LPCB certified products. LPS 1242 Requirements and testing procedures for the LPCB approval and listing of cylinders for locks. LPS 1242 describes the requirements for manual attack of mechanically operated cylinders and their original keys, and applies to cylinders that may be employed in locksets used on the doors of buildings, or in padlocks. Access control systems EN 60839 Electronic access control systems BRE Global provide testing and LPCB certification of electronic access control systems to EN 60839-11-1, Electronic access control systems - System and component requirements. Intrusion alarm systems EN 50131 series Intrusion and hold-up systems. BRE Global provides a range of services related to intrusion alarm systems and components, including testing and LPCB certification to the EN 50131 series of product standards. The EN 50131 series of standards specify the requirements for Intrusion and Hold-up Alarm Systems (I&HAS) and components installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to components of an I&HAS which are normally mounted on the external structure of a building e.g. ancillary control equipment or warning devices. EN 50136 series Alarm transmission systems and equipment. BRE Global provide testing and LPCB certification of alarm transmission system components to the requirements of the EN 50136 series of standards, for example; supervised premises transceivers (EN 50136-2) and receiving centre transceivers (EN 50136-3), including the appropriate requirements of the system standard EN 50136-1. LPS 1277 Requirements for LPCB certification and listing of alarm transmission equipment. LPS 1277 builds upon the core requirements of the EN 50136 standards and defines enhanced performance criteria appropriate to intrusion and hold-up alarm systems. The enhanced performance criteria includes a 10 minute fault reporting time (identified as an essential requirement not provided by the EN 50136 standards) and greatly improved reporting of the simultaneous catastrophic failure of multiple alarm transmission paths. All performance testing to LPS 1277 is carried out over representative live networks as a means to replicate real-world installation. Alarm receiving centres BRE Global certify alarm receiving centres (ARC) to its LPS 1020 standard Requirements for Alarm Receiving Centres. This standard specifies requirements for ARC and incorporates additional clarification for ARC receiving fire alarm calls. CCTV security systems CPNI Video Analytics Assessment Programme BRE Global has been awarded an exclusive contract to be the authorised test house for the Centre for the Protection of National Infrastructure (CPNI) Video Analytics Assessment Programme for the Sterile Zone, Abandoned Baggage Detection, Parked Vehicle Detection and Doorway Surveillance scenarios. This testing has evolved from the previous assessment programme commonly known as i-lids, however both the video datasets and test process remain the same. Systems that demonstrate their ability to alert CCTV operators of suspicious alarm events in these key security areas will be permitted by CPNI to use their trademark. European Fire and Security Group BRE Global is a member of the European Fire and Security Group (EFSG) and is signatory to the intrusion alarms mutual acceptance agreement, which helps product manufacturers achieve multiple certification efficiently and without the duplication of testing. e s g f For more information visit www.efsg.org

About BRE BRE Group BRE is an international, multi-disciplinary, building science organisation with a mission to improve buildings and infrastructure through research and knowledge generation, and their application. BRE employs over 600 people in the UK, China, India, the Middle East and the USA who are committed to building a better world together. Our products, services, standards and qualifications are applied in over 80 countries enabling our customers to make a positive difference to the built environment. We are owned by a charity called the BRE Trust, which delivers one of the largest programmes of built environment education and research for the public good. BRE Global BRE Global Limited (incorporating LPCB & BREEAM) is an independent third party certification body for fire, security and sustainability products and services in an international market. BRE Global s product testing and certifications are carried out by recognised experts in our world renowned testing laboratories. BRE Global Limited is custodian of a number of world leading brands including: LPCB for the certification of fire and security products and services, listed on www.rebooklive.com. BREEAM the world s leading environmental assessment method for buildings, sets the standard for best practice in sustainable design and has become the de-facto measure of a building s environmental performance. All of our environmental certifications are listed on www.greenbooklive.com. SABRE is a security assessment and certification scheme for buildings, infrastructure and managed space. The BIM product data library. Free to list. Free to use. www.databooklive.com BRE Watford, UK WD25 9XX +44 (0)333 321 88 11 enquiries@bre.co.uk www.bregroup.com BRE Trust The BRE Trust uses profits made by BRE Group to fund new research and education programmes that will help it meet its goal of building a better world together. The BRE Trust is a registered charity in England & Wales: No. 1092193, and Scotland: No. SC039320. 1132LPC-BRO BRE November 2017