Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Similar documents
Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

KPSW CONSOLE TERMINAL UNIT

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

LOW STATIC HYDRONIC DUCTED UNIT

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

CASSETTE UNIT. Comfort Circle

EHH SERIES DRAW THROUGH FAN COILS CFM

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Blower-YEFB-020-3R-1maxVel

COMFORT HYDRONIC TERMINALS

Energy. The Energy ducted units have been designed. Heat Recovery Unit

UCS UCS/M UCS/H UCS900

Conditioning your ambient, maximising your comfort.

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

QTS SELECTION TECHNICAL BOOKLET

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

FAN COIL UNITS LASER / LOW BODY / CONCEALED

SIGMA PRISMA LOW BODY CONCEALED

Conditioning your ambient, maximising your comfort.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

CHILLED BEAM CASSETTE IQ STAR LYRA

YFCN Fan Coil Unit centrifugal fan

technical data Fan coil unit FWB small duct unit

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

YAH SERIES FAN COIL UNITS

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

MORE VALUE TO YOUR WELL-BEING

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

MHW Air Handling Unit (50/60Hz)

The Sabiana. of Fan Coil

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

iq Star LYRA II chilled beam cassette

Application guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E

DIRECT DRIVE BLOWER COILS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

TopMaster Air Handling unit. Installation instructions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

System architecture. Air treatment Index

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

a-life Hydronic terminals Fan-coil for professional applications, with cabinet or built-in version 1,50-7,50 kw <<< BACK INDEX

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

Product Specifications. Vertical Floor Consoles By First Co.

INDEX. Main components 3. General features and description of the components 4

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

UniTrane Ductable Units D-line and B-Line

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

TopVent Design Handbook

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Series VENTS VUT R WH ЕС

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

GHE Dehumidifiers for radiant cooling systems with heat recovery

Technical documentation Fan coil unit

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

VERTICAL FAN COIL UNITS

Transcription:

Technical Manual New Water Cassette Series BREZZA DOUBLE

AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2

INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA EFFECT.4 4- KEY READING CODES 5 5-TECHNICAL DETAILS..6 6-TECHNICAL DATA (AC motors) 8 6.1-Cassette with 3 rows coil... 8 7-TECHNICAL DATA(EC motors).9 7.1-Cassette with 3 rows coil... 9 8- COIL TECNICAL DATA(AC motors)...10 8.1- Cassette with 1 or 2 rows coil... 10 9-TECHNICAL DATA OPTIONAL COILS (EC motor) 11 9.1- Cassette with1 or 2 rows coil... 11 10-DIMENSIONAL & WEIGHT...12 11-ACCESSORIES 13 11.1- Valves (V) and auxiliary tray (ADPB)... 13 11.2- Hose connecting valves (Flex2 and Flex4)... 15 11.3- Condensate drain pump Auxiliary (PSCC-BI)... 16 11.4- Speed motor control board... 16 11.5- Flange for air delivery duct (FLMA)... 19 11.6- Flange for external air intake (FLAE-FLAE2)... 19 12-Electrical wiring diagrams 20 12.1- Wiring diagram cassette with AC motor... 20 12.2-Wiring diagram cassette with EC motor... 22

1-INTRODUCTION The new Water Cassette Series units BREZZA are designed for air conditioning in residential and commercial plants. The installation is indoor and not exposed to ice or extreme temperatures, dust-free environment and not explosive materials. The manufacturer is not responsible in case of incorrect use. The series BREZZA is proposed with traditional AC motors with three speeds and which EC motors with low consumption. The table below shows the electric power saving that can be achieved with EC motors (at constant working point of the machine). 2- WORKING CONDITION LIMITS Electrical power supply 220 240V / 50Hz Inletcoil water temperature 5 70 C Return air temperature 10 50 C RH air intake 15 70% It is advisable to let work the Brezza Cassette at the above mentioned extremes limits of operation ONLY for short periods, because the operation for long periods can reduce normal components. 3- COANDA EFFECT New cassette Series BREZZA has been developed to ensure a high comfort. In fact, the particular shape of the panel as per the COANDA effect, avoids the annoying cold drafts (since ever the problem of fan-coil cassettes). The COANDA effect is the tendency of a fluid jet to follow the contour of a nearby surface. So the air flow follows the ceiling, then fells nearly at the wall. Since the air speed at this point is very low, this does not create discomfort to people. Traditional Cassette Cassette with Coanda effect

In case where the ceiling is higher than 3m, accordingly there is the need to channel down the air flow, Aertesi provides an accessory panel with adjustable flaps. So you can set manually, for each of the four turns, the orientation of the flow: horizontal (with Coanda effect), or in vertical position. Flaps on horizontal position (Coanda) Flaps on vertical position 4- KEY READING CODES The standard version is with 3-rows coil (for versions 2 pipes) or 1 + 2 ranks (for versions 4 pipes), with fixed blades in COANDA position. All other versions are optional.

5-TECHNICAL DETAILS STRUCTURE: made on galvanized steel sheet, thickness 1.00mm. The robust design prevents the vibration and it includes mounting brackets to the ceiling. FRONTAL PANEL: painted plate thickness 0.8mm. The conformation of the baffles ensures a Coanda Effect to the air flow output. As an accessory, you can have the adjustable deflectors to have the Coanda effect or vertical airflow (or intermediate positions). The fresh design of the panel fits perfectly into any environment and type of ceiling. ACCESSIBILITY : the filter can be removed without any tools. The accessibility to internal components (fan and condensate pump) is guaranteed by removing the front panel. Water connections, valves and electrical panel are on the same side and thus you need only one inspection hatch in the ceiling. FILTER: Class G1 (EN779), 6 mm thickness, made in polypropylene mesh. FAN GROUP: The fan is made of reinforced plastic material (nylon PA6-25GF); it is backward curved blades, directly coupled to the motor. The motor and fans are balanced after assembly to ensure, vibrations absence. Motor is mounted on ball bearings without any maintenance. The AC motor has three speed, degree of protection IP44, insulation class "B". Thermal protection incorporated. The EC motor is controlled 0-10V, IP54 protection, insulation class "B", noise emissions according to EN 61000-6-3 (civil environment), thermal motor protection and electronics, protection locked rotor. COIL: made with copper pipe diameter 3/8 "and corrugated aluminum fins with high efficiency, with manual air vent valve at the top. Nominal pressure PN10. WATER TRAP: blower housing made of expanded polystyrene (EPP) with condensation molded plastic tray, which ensures no water leakage even after a long use. The shape of the pan facilitates the outflow and ensures minimum water stagnation.

INSULATION: cassette body insulated with cross-linked polyethylene foam 10 mm thick, class B-BL-s2d0 s1d0 according to EN13501-1. Front panel insulated with polyethylene thickness 3mm. ELECTRICAL BOARD: made of galvanized steel plate and positioned on the same side of water connections. CONDENSATE DRAIN PUMP: centrifugal type, equipped with a double level float (on-off pump and alarm) and check valve (to avoid the return of odors from the plughole and reduce the noise power). The maximum head of the pump is 650mm, measured from the edge of the panel.

6-TECHNICAL DATA (AC motors) 6.1-Cassette with 3 rows coil 2 TUBI 4 TUBI 133 163 135 165 Speed(E) min med max min med max min med max min med max Airflow mc/h 560 800 1140 860 1260 1470 560 800 1140 860 1260 1470 COOLING Air 27 C b.s., 19 C b.u. Input water temperature 7 C, output water temperature 12 C Total capacity(e) kw 4,11 5,51 7,46 5,88 8,10 9,16 3,52 4,75 6,23 5,00 6,69 7,47 Sens. capacity(e) kw 2,94 4,00 5,30 4,25 5,72 6,44 2,57 3,37 4,36 3,58 4,68 5,20 Water flow l/h 706 946 1279 1008 1389 1571 603 815 1069 859 1148 1281 Δp water(e) kpa 3,3 5,6 9,8 6,3 11,3 14,1 3,8 6,4 10,5 7,0 12,0 14,6 HEATING Air 20 C inlet water temperature 50 C,same for cooling flow Capacity(E) kw 4,79 6,50 8,71 6,91 9,44 10,66 - - - - - - Water flow l/h 706 946 1279 1008 1389 1571 - - - - - - Δp water(e) kpa 3,1 5,3 9,2 6,0 10,7 13,4 - - - - - - HEATING Air 20 C - inlet water temperature 70 C, output water temperature 60 C Capacity(E) kw - - - - - - 5,25 6,69 8,47 7,03 8,96 9,90 Water flow l/h - - - - - - 476 606 767 637 811 896 Δp water(e) kpa - - - - - - 3,5 5,5 8,3 6,0 9,2 11,2 ELECTRIC MOTOR ABSORTION Consumption(E) W 60 76 100 108 144 174 60 76 100 108 144 174 Max absorption A 0,46 0,80 0,46 0,80 SOUND DATA Sound power(e) db(a) 39 46 56 53 63 66 39 46 56 53 63 66 Sound pressure db(a) 30 37 57 44 54 57 30 37 57 44 54 57 (E)= EUROVENTcertificated data

7-TECHNICAL DATA(EC motors) 7.1-Cassette with 3 rows coil 2 PIPES 4 PIPES 133 163 135 165 Speed(E) 4V 7V 10V 4V 7V 10V 4V 7V 10V 4V 7V 10V Airflow mc/h 410 760 1120 570 1050 1520 410 760 1120 570 1050 1520 COOLING Air 27 C d.b., 19 C w.b.. inlet water temperature 7 C, output water temperature 12 C Total capacity(e) kw 3,11 5,28 7,35 4,17 6,96 9,42 2,61 4,56 6,13 3,58 5,83 7,66 Sens.capacity(E) kw 2,19 3,85 5,22 2,99 4,95 6,60 1,98 3,25 4,29 2,61 4,09 5,35 Water flow l/h 534 905 1260 716 1195 1616 448 783 1052 614 1001 1315 Δp water(e) kpa 2,1 5,3 9,4 3,5 8,6 14,8 2,2 6,0 10,1 3,9 9,3 15,3 HEATING Air 20 C inlet water temperature 50 C, same for cooling flow Capacity(E) kw 3,60 6,24 8,57 4,87 8,12 10,95 - - - - - - Water flow l/h 534 905 1260 716 1195 1616 - - - - - - Δp water(e) kpa 1,8 4,9 9,0 3,3 8,2 14,2 - - - - - - HEATING Air 20 C - inlet water temperature 70 C, output water temperature 60 C Capacity(E) kw - - - - - - 4,16 6,47 8,29 5,32 7,96 10,16 Water flow l/h - - - - - - 377 586 751 481 721 919 Δp water(e) kpa - - - - - - 2,2 5,1 8,1 3,5 7,4 11,7 ELECTRIC MOTOR ABSORTION Consumption(E) W 6 18 42 10 36 97 6 18 42 10 36 97 Max absorption A 0,34 0,76 0,34 0,76 DATI SONORI Sound power(e) db(a) 34 48 59 41 57 66 34 48 59 41 57 66 Sound pressure db(a) 25 39 50 32 48 57 25 39 50 32 48 57 ENERGY SAVING CLASS FCEER (E) A A A A FCCOP(E) A A A A (E)= EUROVENT certificated data

8- OPTIONAL COIL TECNICAL DATA(AC motors) 8.1- Cassette with 1 or 2 rows coil 2 PIPES 4 PIPES 132 162 134 164 Speed min med max min med max min med max min med max Airflow mc/h 560 800 1140 860 1260 1470 560 800 1140 860 1260 1470 COOLING Air 27 C d.b., 19 C w.b.. inlet water temperature 7 C, output water temperature 12 C Total capacity kw 3,37 4,53 5,94 4,80 6,39 7,12 2,28 2,94 3,73 3,12 3,99 4,40 Sens.capacity kw 2,49 3,26 4,20 3,44 4,52 5,02 1,67 2,14 2,67 2,22 2,86 3,11 Water flow l/h 578 778 1019 824 1096 1221 391 504 640 535 684 754 Δp water kpa 3,2 5,5 9,0 6,1 10,2 12,4 2,9 4,5 6,9 4,9 7,8 9,3 HEATING Air 20 C inlet water temperature 50 C, same for cooling flow Capacity kw 4,12 5,45 7,10 5,76 7,63 8,53 - - - - - - Water flow l/h 578 778 1019 824 1096 1221 - - - - - - Δp water kpa 3,0 5,2 8,6 5,9 9,8 12,0 - - - - - - HEATING Air 20 C - inlet water temperature 70 C, output water temperature 60 C Capacity kw - - - - - - 5,25 6,69 8,47 7,03 8,96 9,90 Water flow l/h - - - - - - 476 606 767 637 811 896 Δp water kpa - - - - - - 3,5 5,5 8,3 6,0 9,2 11,2 ELECTRIC MOTOR ABSORTION Consumption W 60 76 100 108 144 174 60 76 100 108 144 174 Max absorption A 0,46 0,80 0,46 0,80 SOUND DATA Sound power db(a) 39 46 56 53 63 66 39 46 56 53 63 66 Sound pressure db(a) 30 37 57 44 54 57 30 37 57 44 54 57

9-TECHNICAL DATA OPTIONAL COILS (EC motor) 9.1- Cassette with1 or 2 rows coil 2 PIPES 4 PIPES 132 162 134 164 Speed 4V 7V 10V 4V 7V 10V 4V 7V 10V 4V 7V 10V Airflow mc/h 410 760 1120 570 1050 1520 410 760 1120 570 1050 1520 COOLING Air 27 C d.b., 19 C w.b.. inlet water temperature 7 C, output water temperature 12 C Total capacity kw 2,46 4,38 5,85 3,43 5,57 7,30 1,75 2,86 3,68 2,32 3,53 4,51 Sens.capacity kw 1,92 3,13 4,14 2,52 3,96 5,12 1,34 2,07 2,64 1,69 2,50 3,19 Water flow l/h 423 751 1004 588 956 1253 299 491 632 398 606 774 Δp water kpa 1,8 5,2 8,7 3,3 7,9 13,0 1,7 4,3 6,8 3,0 6,2 9,8 HEATING Air 20 C inlet water temperature 50 C, same for cooling flow Capacity kw 3,16 5,25 7,00 4,18 6,65 8,73 - - - - - - Water flow l/h 423 751 1004 588 956 1253 - - - - - - Δp water kpa 1,7 4,8 8,3 3,1 7,5 12,5 - - - - - - HEATING Air 20 C - inlet water temperature 70 C, output water temperature 60 C Capacity kw - - - - - - 4,16 6,47 8,29 5,32 7,96 10,16 Water flow l/h - - - - - - 377 586 751 481 721 919 Δp water kpa - - - - - - 2,2 5,1 8,1 3,5 7,4 11,7 ELECTRIC MOTOR ABSORTION Consumption W 6 18 42 10 36 97 6 18 42 10 36 97 Max absorption A 0,34 0,76 0,34 0,76 SOUND DATA Sound power db(a) 34 48 59 41 57 66 34 48 59 41 57 66 Sound pressure db(a) 25 39 50 32 48 57 25 39 50 32 48 57 ENERGY SAVING CLASS FCEER A A A B FCCOP A B A A

10-DIMENSIONAL & DRAWINGS 1 Batteria principale IN 1/2" 2 Batteria principale OUT 1/2" 3 Batteria ausiliaria IN 1/2" 4 Batteria ausiliaria OUT 1/2" 5 Scarico condensa d.12 132/162 133/163 134/164 135/165 Unit gross Weight kg 56 60 56 60 Internal volume main coil litri 2,6 4,0 2,8 2,8 Internal volume auxiliary coil litri - - 1,2 1,2

11-ACCESSORIES Accessories available are: HYDRAULIC ACCESSORIES A/K/C V22 V22 2-way valve ON-OFF 230V A/K V42 V42 2-way valve ON-OFF for 4 pipe A/K V23 V23 3-way valve ON-OFF 230V A/K V43 V43 3-way valve ON-OFF 230V for 4 pipe A/K V22M V22M Valve 2-way modulating 0-10V A/K V42M V42M Valve 2-way modulating 0-10V for 4 pipe A/K V23M V23M valve 3 way modulating 0-10V A/K V43M V43M valve 3 way modulating 0-10V for 4 pipe A/K ADPB ADPB Water trap auxiliary (supplied as standard) K FLEX2 Hoses for parallel connection valves (2 pipes) K FLEX4 Hoses for parallel connection valves (4 pipes) K PSCC-BI PSCC-BI Auxiliary Condensate drain pump A ELETTRICAL ACCESSORIES TR24 Transformer 230Vac-24VAC, 20VA for modulating valve A SC3 3-speed motor control board (for EC motor) A AERAULIC ACCESSORIES FLMA Flange for discharge air duct B FLAE Flange for fresh air intake B A = accessory supplied mounted on the base; K = accessory kit supplied unassembled; B = accessory supplied assembled, but not mounted on the base 11.1- Valves (V) and auxiliary tray (ADPB) We recommend the use of motorized valves, to prevent the formation of condensation on the surface of the unit when the fan is stopped.

Valves can be supplied to the unit assembled or in kit (disassembled parts). All codes kits include two valves, one for each battery in double cassette. The drain pan is supplied as standard with the cassette, without extra-price (ADPB) The cassette have two double 1200x600 kit valves, one for the right battery and one for the left battery. Both kits valves are connected in parallel, the aim is a kit consisting of hoses and TEE brass (see paragraph on accessory Flex2 - Flex4). Heating/cooling valve (2 pipes) Valve cooling (4 pipes) Hot valve (only 4 pipes) Heating/cooling valve (2 pipes) Valve cooling (4 pipes) Hot valve (only 4 pipes) Auxiliary drain pan OUT IN OUT IN 2 pipes (hot/cold) 2 pipes (not present) 4 pipes (cold) 4 pipes (hot) Valves group and auxiliary tray (cassette double 1200x600)

VALVES FOR MAIN COILS --- 132-133-134-135-162-163-164-165 VALVES FOR AUXILIARY COILS 134-135-164-165 --- GENERAL FEATURES Size connections 1/2" 3/4" Kv (valvola 2 vie) 1,7 2,5 Kv (valvola 3 vie, via diritta) 1,7 2,5 Kv (valvola 3 vie, by-pass) 1,2 1,6 Max differential pressure 2,0bar 1,0bar Nominal pressure 16bar Nominal pressure 4-110 C ON-OFF ACTUATOR Power supply 230V-50Hz (24V-50Hz on request) Power consumption 2,5W Running time 180s Feature (valve + actuator) N.C. N.C. (usually closed) Protection IP44 MODULAT ACTUATOR Electrical supply 24V-50Hz Power consumption 1,5W Travel time 8S Control signal 0-10V Impedance control signal 100k Protection IP43 11.2- Hose connecting valves (Flex2 and Flex4) To facilitate the parallel connection of the valves, described in the previous paragraph, you can use the accessory Flex2 (for 2-pipe systems) and Flex4 (for 4-pipe systems). The kit consists of hoses with braided stainless steel (with 3/4 "for the valve) and brass TEE to connect the pipes from 3/4". You can also directly connect the hoses to the coil, inserting an adaptor nipple 1/2 "-3/4" (nipple not supplied). BRASS TEE FLEX INOX Accessory for flexible double cassette 1200x600

11.3- Condensate drain pump Auxiliary (PSCC-BI) The supplementary condensate drain pump is supplied assembled outside of the box, at the side of the drainage pipe. Then must provide for the possibility of inspection also on this side. Maximum water flow Maximum discharge height Sound pressure 1m Supply Micro switch alarm Thermal Protection Protection 20 l/h 10m (4l/h) 28dB(A) 230V 50/60Hz NC 8 resistivi 250V 90 C (riarmo automatico) IP54 11.4- Speed motor control board SC3 The 3-speed motor board allows you to control the EC motor with a traditional thermostat 3-speed or with a thermostat with 0-10V signal. With this accessory, it is also possible to control more than one unit with a single thermostat (not addressable master-slave). For each double cassette, you need two cards SC3 (to be considered as a slave of the other). CONTROL FROM EXTERNAL THERMOSTAT VH Contact on-off valve heating (4 tubes) VC Contact on-off valve cooling (2-4 tubes) MIN Minimum fan speed MED Minimum fan speed MAX Maximum speed fan GND Reference signal 0-10V 0-10V 0-10V signal for motor control

ELECTRICAL CONNECTIONS FOR 3 SPEEDSCONTROL : you must close the jumpers J3 and J4; jumpers J1, J2, J5, J6 are reserved to factory settings and should not be changed. Model J1 J2 J3 J4 J5 J6 7x-13x opened closed closed closed closed closed 9x-16x closed opened closed closed closed closed

ELECTRICAL CONNECTIONS FOR CONTROL SIGNAL 0-10V: you must open the jumpers J3 and J4; jumpers J1, J2, J5, J6 are reserved to factory settings and should not be changed. Model J1 J2 J3 J4 J5 J6 7x-13x closed closed opened opened opened opened 9x-16x closed closed opened opened closed opened

11.5- Flange for air delivery duct (FLMA) You can connect up to 3 throws ducted through D.160 collars. The available prevalence is a function of the number of collars connected and the air flow rate. Collars positions are represented in the figure below. 11.6- Flange for external air intake (FLAE-FLAE2) It is possible to connect an external air intake via a D.100 collar. The maximum flow of outside air is 100MC/h. The outside air has to be treated, filtered and must not be at a low temperature. The flange for fresh air intake has FLAE code or FLAE2 code. These have different installation points on the unit, as in the drawing below.

12-Electrical wiring diagrams 12.1- Wiring diagram cassette with AC motor

12.2-Wiring diagram cassette with EC motor

CONTROL FROM EXTERNAL THERMOSTAT VH Contact on-off valve heating (4 tubes) VC Contact on-off valve cooling (2-4 tubes) MIN Minimum fan speed MED Minimum fan speed MAX Maximum speed fan GND Reference signal 0-10V 0-10V 0-10V signal for motor control NOTES: Aertesi srl. It reserves the right to introduce at any time whatever modifications deemed necessary for improving the product with possible modification of the relevant technical data

AER.MT.I.BREDOPPIA.000.02.15 Aertesisrl Unipersonale viale della tecnica, 6a 35026 Conselve (PD) ITALY t. +39.049.9501109 f. +39.049.9500823 www.aertesi.com info@aertesi.com