Marlin Filament Monitoring October 2014

Similar documents
Integration Guide AXIS Camera Station and AXIS A8004-VE

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

WeatherLink for Alarm Output Addendum

Intelligent Security & Fire Ltd

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Multistate Alarm. Introduction

Summit 3208GLD USER MANUAL. Electronics Line

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

HERCULES 6 GRAPHICS SYSTEM

Control Panel User Guide (TO BE RETAINED BY THE USER)

Watchguard WGAP864 User Manual

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Fire detection and alarm system Operating instructions

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

IntesisBox BACnet/IP Server - Notifier ID3000 series

Manage Alarms. Before You Begin CHAPTER

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Cold chain monitoring technologies. Facility monitoring

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

SALES SUPPORT DOCUMENT

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Added password for IP setup page : Password must be in IP format!

Manage Alarms. Before You Begin CHAPTER

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

False Alarm Management

ZP2 Series Operation Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

OpenDevice Events Guide

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

CBI-064. User Manual. Caddx to KNX-BUS Interface

The EN54 Part 2 & 4 Fire System

Section 9 System Operation

Fire Control Panel FS5100

Sentient. Downloader Manual D4854

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

FlameGard 5 UV/IR HART

SCAN200E USER S MANUAL

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

Alarm module for leak detection with webserver

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

X64 Wireless Training

Configuration and Operation Manual for the Unipos

Alarm project board for micro:bit.

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators reference guide

Contents. Glossary

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Manage Alarms. Before You Begin CHAPTER

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Manage Alarms. Before You Begin CHAPTER

GE Security SAPPHIRE Pro

KFP-AF Series Fire Alarm Control Panel Installation Manual

P2267 NETWORK INTERFACE

Installation and User Instructions

GLOBAL. InstallatIon & operation manual

The complete R&TTE Declaration of Conformity for each Panel can be found at

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

16 and 16 plus User s Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Advisor Advanced Mobile Application User Manual

Paradox Integration Module Settings Guide

Metasys Integrator TITUS Application

Operation Manual For model CM706E

Integrated Security Solutions

DEVELOPMENT OF THE TANGO ALARM SYSTEM

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Section 8 System Operation

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

AK-CS On Board Guide

U ser's Guide PC6010

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

The Challenger Version 8 User Guide

CSP-204 CSP-208 CSP-104 CSP-108

Refrigerated Incubator Model and Operating Instructions

RS485 MODBUS Module 8AI

FieldServer Driver - Serial FS Notifier NCA

Dryer Controller M720

REPEATER FS5200R INSTRUCTION MANUAL

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

QA16 Addressable System

Independent Zone Control (I.Z.C.)

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

IDS816 User Manual H Issued January 2009

VMD Guide for V960 Series Cameras

RMS/RPX Reader. User Manual

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Transcription:

Why is Filament Monitoring Useful? Marlin Filament Monitoring October 2014 There are a number of filament monitors and filament break detectors available which will generate an alarm if the filament runs out. Some will also detect when the filament tangles to the point where it won t feed properly. However the standard Marlin firmware does not have the built in capability to recognise the filament monitor alarm and to automatically pause the print and resume when the filament problem is cleared. The aim of this note is to explain how to add the filament alarm function in Marlin so the print pause and resume can be handled automatically. The notes assume that a RAMPS 1.4 board is used as the printer driver, interface and connections board. The Filament Change function in standard Marlin also assumes that an LCD controller display is connected to the printer. Marlin Software Modifications The mod to add the pause and resume uses the filament Change function built into standard Erik/Zalm Marlin on GitHub. The same modification can also be made to the Marlin firmware adapted for the Robo3d The Marlin mods are intended to be simple and robust and use using existing Marlin functionality where possible. The code changes required in the file marlin_main.cpp are highlighted :

And in the loop() code Note that the alarm is expected to be a LOW signal on Pin 44. The Marlin modification assumes that alarms (ie Pin 44 going LOW) will only ever be received when the printer is actually in operation and printing (ie using filament). Typically Filament Monitors are reset manually before printing and do not generate alarms until after the filament has started moving. In addition to the code modifications, the following standard Filament Change parameters need to be set in the configuration_adv.h file.

You can, of course, modify these X, Y and Z parameters to suit where you want the extruder to move to so you can change or untangle the filament. The Z value is relative to where the Z was when the print was paused. Note that with the choice of X position you need to remember not to pull any further on a filament that may be tangled. Finally save the modified marlin_main.cpp and configuration_adv.h files, recompile and upload the firmware to the printer. Filament Monitor Alarm Signal The Filament Monitor alarm signal needs to be connected to Pin 44 on the RAMPS 1.4 circuit board. This pin is located on the RAMPS 1.4 AUX-2 connector. There are also +5v power and ground pins on the same AUX-2 connector.

Handling Filament Monitor Alarms When a filament alarm is received, the modified Marlin will handle the alarm as follows The printer completes the current gcode command An M600 change filament gcode command is generated which causes the printer to stop printing then move the extruder to the X, Y and relative Z position specified by the configuration_adv.h file Filament Change parameters. The alarm buzzer on the LCD Controller sounds to bring some attention to the alarm. A Filament Change message appears on the LCD display. A M600 log message is sent to the host PC (if connected) The extruder and bed remain heated to their current temperature settings during the pause. While the alarm buzzer is operating there is an opportunity to change or untangle the filament. The alarm buzzer can be annoying when operating for a long time, but that s the way standard Marlin handles a Filament Change. Note : Do not move the extruder by hand (or using any gcode command) during the filament change. The reason is that Marlin needs to know how to move the extruder back to the correct position to resume printing. When the filament is changed and you are ready to resume printing, press the encoder button on the LCD Controller. The alarm buzzer is then cancelled and the extruder moves back and resumes printing exactly from the position where it paused. Note: In a situation where the LCD Controller is defined but there is no LCD Controller actually connected, it is also possible to use the host software to pause the print when the M600 log message is received and then manually resume printing by host command. But in this case there is no audible alarm and the process is not as simple as using the LCD Controller button.

Code Text for copy/paste // filament monitor mod - Ziggy 14/10/2014 boolean FC_Flag = false; // initialise flag to enque M600 command once per alarm // filament monitor mod - Ziggy 14/10/2014 // // note FC_Flag variable must be global // if (digitalread(44) == LOW) { // check filament monitor alarm pin if (FC_Flag == false) { // not already triggered? enquecommand_p(pstr("m600")); // trigger a filament change FC_Flag = true; // } } else FC_Flag = false; // reset for next alarm