Installation and Operation Manual

Similar documents
C Installation and Operation Manual

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

GST-FT40N Fire Telephone Panel Installation and Operation Manual

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

ALARMLINE ANALOGUE Linear Heat Detection System

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

CONTENTS. GstDef2.1 Defining Tool User s Manual

SOUNDER CONTROL MODULE SCM-AS4

GST Headquarters. GST Production Base

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Conventional Fire Alarm System 2014 V1.2

Instructions AutroFlame IR Flame Detector BG-201/BG-21

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

XP95 Sounder VAD Base

Interface Modules for SENTRI

Attention Items: I. Brief Introduction

General Routing Interface

Input/Output Modules Data Sheet

Fire & Security Products. Siemens Building Technologies Group

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

ALK-V PHOTOELECTRIC SMOKE SENSOR

SERIES 65 ENGINEERING PRODUCT GUIDE

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Reflective Optical Beam Smoke Detector User Guide

Series 65 Product Guide MAN 3036

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

INPUT / OUTPUT MINI MODULES

Guide To Troubleshooting INEFFICIENT COOLING FANS

LF /2. Fire Alarm Control Panel. Features:

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Intelligent Security & Fire Ltd

Reflective Beam Smoke Detector

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Public Safety DAS Annunciator Panel

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

End To End Optical Beam Smoke Detector. Additional Information

Rosemount High Density Temperature Measurement. Simplify Your Project

5, SE GÅNGHESTER,

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Technical Manual for the Alarm Pull Station PH1

Event Detection System (EDS)

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Reliably Advanced Extinguishing Control

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

S TEM PRODUCT SPECIFICATION

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Helios W.E.S & 2000 (Wireless Emergency Stop) User Guide. E6, Version 1.2. Helios Global Tech Ltd.

HOA Series IR Opaque Optoschmitt Sensor, Transistor Output, Two Mounting Tabs, Plastic Package

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Installation, Operating and Maintenance Manual

IDP-Zone-6 Six Zone Interface Module

Range brochure. Beam detection. others look up to.

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

DAWN Electronics, Inc.

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Exit Stopper. STI-6400 Series

Remote Display Alarm Indicator for Oxygen monitor

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Sensepoint XCL Fixed Gas Detector

TrueAlarm Analog Sensing

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Bagless upright vacuum

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

APPLICATION NOTES. Stone Technologies Corporation Westrock Dr. #4 Austin, Texas OUT + + IN - + IN - + IN - + IN -

Intelligent Security & Fire Ltd

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Open-area Smoke Imaging Detector. Engineering Specification

Heat Sensor Cable Alarm Units DT650L / DT950L

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

The new detector from Rafiki

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

GLD-30 Gas Leak Detector

MD12-1 Vehicle Loop Detector

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

IFD-E Flame Detector User Manual

Transcription:

C90 Rate of Rise and Fixed Temperature Heat (Issue., March 006)

C90 Rate of Rise and Fixed Temperature Heat CONTENTS I General... II Features... III Technical Specifications... IV Structure and Operation Principle... V Mounting and Wiring... VI Applications... VII Troubleshooting... VIII Cautions...

C90 Rate of Rise and Fixed Temperature Heat I General C90 Rate of Rise and Fixed Temperature Heat (hereinafter called the detector) checks ambient temperature with the sensitive feature of the thermosensitive elements. With a builtin SCM, it s fixed with highly reliable fire judging program. Special processing technology ensures its stable and reliable operation. Matching with P9907 Active End of Line Unit, it can connect with compatible fire alarm controller to process detector signals. II Features With novelty structure, attractive appearance, stable and reliable performance, the detector is especially applicable to places where fire occurs with a sharp rise of temperature. Used together with smoke detectors, it can detect fire with more reliability to reduce losses. The detector has a remote LED output terminal to connect with remote LED. III Technical Specifications. Operating Voltage: VDC 8VDC. Static Current 60µA (Note: The detector can work within VDC 8VDC in static state). Alarming Current: 0mA I 0mA (Note: The alarming current depends on the current limit of the controller. It s not allowed to power the detector directly by VDC Otherwise it will be blown as a result of without current limiting resistor.). Maximum Ripple Voltage: V(peaktopeak value) 5. Alarm Reset: Instantaneous Cut out (5s MAX,.5VDC MAX) 6. Powerup Time 0s 7. Weight: About 0g 8. Monitoring Area: 0m for space height not higher than 8m. 9. Operating Environment: Temperature: 0 50 Relative Humidity 95%, no condensation 0. Dimension: Diameter: 00mm Height: 5mm (without base). Wiring: Connecting with the power cable by polarized twowire.. Alarm Confirming LED: Red, not lit when polling, constantly lit when alarming.. Remote LED Output: Directly connect with remote LED (with a k resistor connected in series inside).. Degree of Protection of Enclosure: IP5 5. Material and Color of Enclosure: ABS, ivory white 6. Mounting Hole Distance: 5mm 75mm Page

C90 Rate of Rise and Fixed Temperature Heat IV Structure and Operation Principle. Appearance of the detector is shown in Fig.. Fig. Appearance. Operation Principle The detector uses a thermistor as its sensor, whose output signal is input into its SCM after transformed by amplifying circuit, and the SCM processes the signal with algorithm. The detector adopts current output mode. When the SCM checks fire signal, it will light the fire LED, and the loop current increases. V Mounting and Wiring. Mounting of the detector is shown in Fig.. Wiring Tube Embedded Box Orientation Base Fig. Mounting. The bottom and orientation base of the detector are shown in Fig. and. There are four terminals with numbers on the base, connects with the anode of the output end of compatible controller, connects with the power anode of the next detector as output (terminal No. ), connects with the power cathode of the next detector (terminal No. ) and the cathode of the output end of compatible controller. "" connects with anode of remote LED,"" connects with cathode of remote LED. There are location elements on the detector and the orientation base to ensure there is only one installing position. There are two marks on point A and Page

C90 Rate of Rise and Fixed Temperature Heat B of the orientation base, and a mark on point C of the side face of bottom of the detector. When installing, aligning the mark C of the detector to point A of the orientation base, rotate the detector clockwise to point B, then the detector is installed. C Mounting Hole Fig. Bottom of the detector Fig. Orientation base. Wiring: Twisted pair with cross section.0mm. VI Applications. When the detector is connected with compatible controller in series, if a P9907 Active End of Line Unit is connected to the loop output terminal, a diode IN589 should be connected with the detector base. ) When the active end of line unit is used as the detector base, that is to install a conventional detector on it, the system composition is shown in Fig.5. Compatible Controller Output Output Remote LED Remote LED Manual Call Point Active End of Line Unit Fig. 5 System composition ) When the active end of line unit is not used as the detector base, a cover should be added to it. The system composition is shown in Fig. 6. Output Compatible Controller Output Active End of Line Unit Manual Call Point Fig. 6 System composition Page

C90 Rate of Rise and Fixed Temperature Heat. When the detector is connected with compatible controller in series, if a terminal resistor is connected to the loop output terminal, then no diode is connected to the detector base. The system composition is shown in Fig.7. Compatible Controller Output Output.7k Resistor Manual Call Point Fig. 7 System composition Output loop of compatible controller can at most be connected with 5 conventional field devices. The compatible controller has the function of checking loop breakage. When any field device in the output loop is removed, it alarms fault. If P9907 Active End of Line Unit is connected, it will not affect the normal operation of other field devices. VII Troubleshooting When any problem occurs, first check wiring correct or not and screws loose or not, then open the enclosure to see whether anywhere is not well soldered or is blown. Possible problems and solutions in commissioning are listed below. No alarm Check diode VD, thermistor RT, voltage stabilizing integrated circuit N and D and ambient circuits. Nuisance alarm Check triode VT and D etc. VIII Cautions Before installation, the detector should be kept well and taken corresponding measures for dustproof, dampproof and corrosionproof. The dust cover cannot be removed until the project has been plunged into usage. Page

GST China Gulf Security Technology Co., Ltd. No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 06600 Tel: 86 (0) 5 85058 Fax: 86 (0) 5 85089 Email: sales@gst.com.cn www.gst.com.cn GST UK Global System Technology PLC Enterprise Glade, Bath Lane, Moira, South Derbyshire, England. DE 6BD Tel: (0)8578 Fax: (0) 8 0 690 Rigional Office PO Box 7998 Unit ZA0 JEBEL ALI Free Zone, Dubai, UAE Tel: 97 (0) 88050 Fax: 97 (0) 8805 Email: tech.support@gst.uk.com www.gst.uk.com