Arc Fault Detection Devices (AFDDs) Protecting People and Property

Similar documents
17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

NFPA 70E Electrical Safety in the Workplace

Arc Flash Protection Training - NFPA 70e Electrical Safety

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Electrical Safety Compliance: NFPA 70E

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

The Basics Arc Flash Protection

PROTECTING AGAINST ARC FLASH HAZARDS

Applying the 2012 NFPA 70E. Arc Flash Standard

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

PGR-8800 TECHNICAL FAQ

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Electrical Safety Through Design. Mersen EP formerly Ferraz Shawmut

How to reduce exposure to arc flash hazards

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

NECA. Standard for Electrical Safety in the Workplace

Webinar November 12, 2014

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

NFPA 70E Edition Update

The safe way to verify the absence of voltage.

Safety Meeting Topic #37 NFPA 70E What is it?

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Arc Fault - Minimize damage

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

NFPA 70E Electrical Safety & Arc Flash Training

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Safety requirements for voltage testing instruments

Compliance without compromise Safety without sacrifice

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

ADIPEC 2013 Technical Conference Manuscript

2009 NFPA 70E Clearing Up Confusion

US Navy Leading the Way in Switchboard Protection

NECA S System Approach to Electrical Safety for NFPA 70E

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

NFPA 70E Update: Key Changes You Need to Know to Assure Compliance

Compliance Solutions: NFPA 70E 2018 Edition from Schneider Electric Services

CIRCUIT BREAKER FAIL PROTECTION

Arc Fault Protection ARCON. ARCON. The Lightning Fast Airbag for Your Switchboard.

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

United Electric Controls One Series Safety Transmitter Safety Manual

Measurement of Safety Integrity of E/E/PES according to IEC61508

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

AQ 100 Series. Arc Flash Protection System

Promoting Electrical Safety through NFPA 70E Standards Adherence

Operating Guide Safe Torque Off

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

IEC61511 Standard Overview

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

NECA S System Approach to Electrical Safety for NFPA 70E

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

New Developments in the IEC61511 Edition 2

NFEC FIRE SAFETY SEMINAR Krish Mysore

For Complete Fire and Gas Solutions

STRATEGIES FOR RELIABLE ARC FLASH DETECTION IN LOW- VOLTAGE SWITCHGEAR

Arc Fault Protection ARCON ARCON. The Lightning Fast Airbag for Your Switchboard.

Continuous, real-time detection, alarming and analysis of partial discharge events

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Predictive Maintenance Training

FALCON SERIES 12 METAL CLAD

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Major Fault Caused by Stator Winding Circuit Ring Failure

2015 Functional Safety Training & Workshops

Arc Flash and Selective Coordination

NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE 2012 Edition

2015 Honeywell Users Group Europe, Middle East and Africa

We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express

Arc Fault Detection Device (AFDD) is an innovative automated equipment for prevention of fires from arcing in electrical circuits and electrical

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Siemens Process Automation End-user Summit- 2011

SALISBURY ASSESSMENT SOLUTIONS

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

Operating Manual MS220KA and MSR220KA

SIPROTEC Products and Solutions for Protection Systems

OPUCN CUSTOM INCENTIVE RATE PLAN PERFORMANCE REPORT

Safety of Electrical Installations

1S20 User Guide. Arc Fault Monitor. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide. Test Manual

Electrical Energy department

CSE. Arc Flash Safety eguide. Sponsor Overview. Preventing Arc Flash Incidents By Design. Integrating Electrical Safety With Design

Documentation guide to get your plant on the positive list (Category A1/A2)

Applications and Discussions of Arc Flash Protection Relay as a Main Busbar Protection in MV Switchboards

Transcription:

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Singapore Standard : CP5 Code of practice for electrical installations - Foreword 2

BS 7671 : the 18 th Edition report Short Brief 3

BS 7671 : the 18 th Edition report Significant changes Protection against overvoltage 4

BS 7671 : the 18 th Edition report Significant changes Protection against overvoltage 5

Overview Electrical Switchboard has to be safe and available balanced with the constraints of reliability and maintainability. Safety Reliability Availability Maintenability Switchboard conforming to IEC 61439 provides insurance on switchboard realization quality 6

Why arc flash protection? 7

What is arc flash/blast? 8

Statistics related to arc flash incidents US Statistics Arc flash injuries 30,000 Arc Flash Incidents per year 7,000 Burn Injuries per year 2,000 Hospitalisations per year 400 Fatalities per year 80% of Electrical Worker fatalities are due to burns, not shock - Arc flash statistics 2013 by ISHN 9

Statistics related to arc flash incidents 10

Statistics related to arc flash incidents The fifth victim, in his 40s, suffered some discomfort in his left ear, following the incident. He told Shin Min Daily News at the hospital that when he and a manager were in the room overseeing electrical works, they saw a sudden flash of light before hearing a very loud explosion. 11

What happens? Time matters! 0.2 sec Steel fire 0.15 sec Copper fire 0.1 sec Cable fire 12 kv, 40 ka 12

Causes of arc accidents The most common reasons for arc flash accidents Human errors Mechanical faults Bad connections Aging/Insulation defect Animals When do arc flash accidents occur? 25 % without operator 10% with operator in front of a closed door 65 % with operator working in the switchgear 13

Arc flash standards and regulations World wide standard US IEEE-1584 OHSA NFPA 70E ABS Europe: IEC work-arc box Asia AS/NZS 3000/4836 GB/14598.302 Specification for arc flash equipment 14

Arc flash standards and regulations World wide standard US IEEE-1584 OHSA NFPA 70E ABS Europe: IEC work-arc box Asia AS/NZS 3000/4836 GB/14598.302 Specification for arc flash equipment 15

Arc flash study history 25th annual Electrical Engineering Safety Seminar 2015, Australian 16

Arc flash study history 25th annual Electrical Engineering Safety Seminar 2015, Australian 17

What s future of arc flash study? 25th annual Electrical Engineering Safety Seminar 2015, Australian 18

What are the directives in Australia? 25th annual Electrical Engineering Safety Seminar 2015, Australian 19

What are the directives in Singapore? 20

Incident energy (IE) calculation IEEE 1584 NFPA 70E -2004 The end customer doesn t want to do this calculation 21

NFPA Hazard Levels Hazard Risk Category Typical Personal Protective Equipment (PPE) Arc Rating (cal/cm 2 ) 0 Non-melting, flammable materials with at least 4.5 oz/yd 2 0-1.2 1 AR pants and AR shirt, or AR coverall 1.2-4 2 Cotton underwear, plus AR shirt and AR pants 4-8 3 Cotton underwear, plus AR shirt and AR pants and AR coverall 8-25 4 Cotton underwear, plus AR shirt and AR pants and multilayer flash suit Moonsuit 25-40

Typical PPE Suit Requirements 0 1 2 3 4 <1.2 cal/cm 2 1.2-4 cal/cm 2 4-8 cal/cm 2 8-25 cal/cm 2 25-40 cal/cm 2

Mitigation activities?

Incident energy (IE) reduction

Incident energy (IE) reduction

Arc flash detection and outcome minimization : Arc guard system TVOC-2 27

Arc guard system TVOC-2 How does it work? Arc initiation Detection Activation Breaker opens 1. Arc is detected by the fiber optic sensor 2. Signal is sent to the TVOC-2 arc monitor 3. TVOC-2 arc monitor sends a trip signal to shunt trip of circuit breaker 4. All this occurs in under 1ms 28

Arc guard system TVOC-2 How does it work? 29

Arc guard system TVOC-2 Safety Integrity Level - SIL Safety Integrity Level (know as SIL) as per IEC-61508 and IEC-62061 A measure of safety system performance in terms of Probability of Failure on Demand (PFD), established to define a metric for evaluating a system s (or function s) level of operational reliability with regards to maintaining safety TVOC-2 is certified with a PFD of 3.49 x 10-03 (0.00349) per year for a period of 10 years after it is first connected (as long as suggested maintenance is performed annually) 30

Arc guard system TVOC-2 Safety Integrity Level To meet SIL-2 safety standards, we need: Redundancy Hardware (IGBT s, relay outputs, IRF,etc) Software (HMI, PC boards, etc) Reliability Self-monitoring of internal faults All light sensors will be manufactured and tested in similar conditions according to EN ISO 13849-1 Reduce the probability of errors caused by external factors Cannot adjust the sensitivity of the sensors Cannot shut down the system for maintenance Cannot change safety configuration parameters via HMI Third-party certification TVOC-2 is certified SIL-2 by TÜV Rheinland 31

Arc guard system TVOC-2 Installation Example 32

Arc guard system TVOC-2 Where the system is used Chemical Plant Oil Rigs Substation 33

Arc guard system TVOC-2 Where the system is used Manufacturing Hospital Transport 34

Arc guard system TVOC-2 Current Sensing Module to prevent Nuisance Tripping Used to monitor current Simply connect CT s with an output of 1, 2 or 5A Can monitor only 1 phase although 3 is suggested Must be adjusted to nominal current level Once current reaches 140% of set level, trip signal is sent 2 types of signals sent from CSU to TVOC-2 1. Light = no fault, proper operation 2. No light = overcurrent signal Total reaction time of TVOC-2 + CSU = 2-3ms when monitoring current on 3 phases 36

Arc guard system TVOC-2 How does it work? 60W at 2 cm of distance 1 20 60 150 190 220 500 2000 Arc detected lux (symbol: lx) is the SI derived unit of illuminance and luminous emittance, measuring luminous flux per unit area 37

BS 7671 : the 18 th Edition report Full report 38