4TEMPERATURE CONTROLLER

Similar documents
Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

F4 Process Controller Installation and Operation Guide

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Temperature Controllers

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

MICRO CONTROLLER S Z SERIES

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

TEMPERATURE CONTROL MODULE MODEL R3-TC2

02/11/2015

I/A Series 716C 1/16 DIN Temperature Controller

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

99 Washington Street Melrose, MA Phone Toll Free Visit us at

02/11/2015

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

TEMPERATURE CONTROLLER

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

MICRO CONTROLLER E Z SERIES

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

Instruction manual Micro-computer based digital indicating controller

7EF/7HF/7EC/7ES Temperature Controllers

Model 96VTR ¼ DIN Process Controller

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Instruction manual Temperature Controller KT7

GCS-300 No.GCS31E

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

UDC 700 Universal Digital Controllers and Indicator Specifications

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Instruction manual for DIN rail mounting type indicating controller DCL-33A

VERTEX F4 Instruction Manual

Specification , July 2015

CN4800 Series CONTROLLER

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Series Temperature Controller Instruction Sheet

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

MC-5 Series Micro Processor Temperature Controller

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Nov 08 PRODUCT SPECIFICATION SHEET

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Temperature Controller

Terwin Instruments Ltd.

CB103/CB403/CB PRODUCT CHECK 2. MOUNTING - * - / /Y INSTRUCTION MANUAL WARNING. 2.1 Mounting Cautions CAUTION RKC INSTRUMENT INC.

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

SR70 (SR ) Series Digital controller Instruction Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Universal controller for panel mounting Models CS6S, CS6H, CS6L

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

TC515 and TC600 Installation Manual. a Winters company

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

1. PRODUCT CHECK 2. MOUNTING - * - / /Y

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

SHIMADEN DIGITAL INDICATORS

1. PRODUCT CHECK 2. MOUNTING

AutomationDirect. PC35 Configuration Sheet

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

INSTRUCTION MANUAL FOR TOUCH PANEL MONITORING UNIT CMT-220-K

General Specifications

Multi-point Digital Controller MA900/MA901. Initial Setting Manual IMR01H03-E4 RKC INSTRUMENT INC.

Operation manual for BOD-80. 3, Hagavish st., Holon,Israel Tel: , Fax: Page 1 of 6 pages

+ A B V B NO NC V COM PV PV

Example of Applications and Parameter Functions

Series Digital Controller Instruction Sheet

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Temperature Controller SA100. Initial Setting Manual IMR01J03-E1 RKC INSTRUMENT INC.

DC1000 Series Digital Controller Product Manual August 2005

MODEL MP-1S OVERSPEED UNIT

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Table of Contents SECTION PAGE

KC-400 KC-600 KC-700 KC-800 KC-900

UDC100 Universal Digital Controller Specifications

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

OVEN INDUSTRIES, INC.

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

Thank you for purchasing an Autonics product.

CEMA CM20 Series Digital Controller Operation Manual CM24 CM22 CM21 CM23 CM25

Preface USER MANUAL. Copyright Reserved Autonics Co., Ltd. I

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

203RE ph v 1.0 Instructions

Low Temperature Zirconia Oxygen Analyzer

ESSEX ENGINEERING CORPORATION

Process & TeMPerATUre UniversAl input DigiTAl MeTers

CM 8. Temperature controllers with compact dimensions. Manual 42/61-71 EN Rev. 01

INSTRUCTIONS FOR THE 8500 SERIES MICROPROCESSOR BASED TEMPERATURE CONTROL

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

The range of ATR243 controllers comes in three versions. Refer to the table below to easily select your preferred model.

DT968C C.T. BATH CONTROLLER

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

R1000 / R1040 / R1080

Transcription:

Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and suffix code () L SUFFIX ODE DESRIPTION MX ONTROL OUTPUT O P T I O N 1 Retransmission output 2 Heater reak Alarm(HA) 3 Remote input F Option is not valid in MX-F. In current output(), lamp signal of OUT does not flash. M S V N N P N MX2/3/// Normal PID Auto-tuning Relay contact urrent(~20ma D) SSR drive pulse voltage(0/12v D) Voltage(1~5V D) None Refer to ODE None HA function(t separately) None Refer to ODE ODE 1 D 0~10mV 2 D 0~100mV 3 D 0~1V D 0~5V 5 D 0~10V 6 D 1~5V D 0~20mA 8 D ~20mA 68

R TEMPERATURE ONTROLLER Functional Description MX-F Auto tuning(at) Remote input(rem) ontrol output(out) Alarm1(AL-1) Mode(SET) key Setting digit shift key AT REM OUT AL-1 AL-2 H-LA MAN PV SV MX Process-value(PV) Set-Value(SV) ontrol loop break alarm(la)/ Heater break alarm(ha) Alarm2(AL-2) Set-Value increment key Set-Value decrement key TEMPERATURE ONTROLLER Input and Range Signal Input Temperature range Signal Input Temperature range K -50~132 (-50.0~. ) -50~2500 (-50.0~.) PR(R) 0~160 32~3200 J -50~1100 (-50.0~. ) -50~2000 (-50.0~.) PR() 0~160 32~3200 E -1~50 (-1.~50.0 ) -1~100 (-1.~.) PR(S) 0~160 32~3200 T Pt 100Ω (DIN) Pt 100Ω (JIS) -1~00 (-1.~00.0 ) -1~6 (-1.~6.0 ) -1~6 (-1.~6.0 ) -1.~50 (-1.~50.0) -1~1200 (-1.~.) -1~1200 (-1.~.) 1~5V ~20mA 0~5V 0~20mA -1~3200 (1 Mode) -1~ (0.1 Mode) -1~3200 (1 Mode) -1~ (0.1 Mode) ** autions for input selection 1) When you select input mode, you must shift jump switch inside of P to ORRET position first. 2) Afterwards select each input mode by key operation. Input T../Voltage urrent Switch position T PT R 6

T. MAIN TEMPERATURE ONTROLLER L MX-F MX-F TEMPERATURE ONTROLLER Appearance External dimension Input Accuracy 6X6mm(1/ DIN), mounting depth:100mm 11 Kinds of input (See input range) 2X2mm, mounting depth:100mm [Setting accuracy] T/: Within±(0.3% of SV 1 digit) or ±2 (Whichever is larger) R.S: ± 1 digit R.T.D: Within±(0.3% of SV 1 digit) or ± 0.8 (Whichever is larger) [Display accuracy] Same as setting accuracy. Power supply ontrol action ontrol output Alarm output Ambient temperature Net weight 100 to 20V A (ommon to 50/60Hz) (Excluding power supply voltage variation) PID (Auto-tuning function), ON/OFF, P.PI.PD Relay contact: A 250V 3A (Resistive load) 1(NO/N) contact SSR driving:12v D (onstant voltage pulse) [load resistance more than 800Ω] urrent: -20mA D [load resistance less than 600Ω] Voltage: 0-10V D [load resistance less than 1kΩ ] Deviation or process setting Relay contact output: A 250V 0.5A (AL-2), 3A (AL-1) 0 ~ 50 (32 ~ 122 ) Ambient humidity:35 ~ 85% RH Approx 35g Approx 300g onnection 10 OM AL-2 20 LA/HA 1 8 18 1.T TRANSMIT REM - 6-20mAD - 16 5 15 A T. - 3 2 1 1 100-20VA 50/60Hz 12VA 13 H 12-20mA D 12VD L 11 OM AL 2 LA/ HA A 6 5 3 2 1 TRANSMIT 20mAD URRENT VOLTAGE 12 11 10 8.T REM 1 18 1 16 15 H 1 L 13 100 20VA 50/60Hz 12VA AL 1 20mAD 12VD 0

MX2-F MX3-F MX-F 8 6mm(1/8 DIN), mounting depth : 100mm 6 8mm(Horizontal), mounting depth : 100mm 8 8mm(1/16 DIN) 11 Kinds of input (See input range) Setting accuracy T/ :Within±(0.3% of SV1 digit) or±2 (Whichever is larger) R.S :± 1 digit R.T.D :Within±(0.3% of SV1 digit) or±0.8 (Whichever is larger) Display accuracy Same as setting accuracy TEMPERATURE ONTROLLER 100 to 20V A(ommon to 50/60Hz)(Excluding power supply voltage variation) PID (Auto-tuning function), ON/OFF, P.PI.PD Relay contact:a 250V 3A(Resistive load) 1(NO/N) contact SSR driving :12V D(onstant voltage pulse) load resistance more than 800Ω urrent :-20mA D load resistance less than 600Ω Voltage :0-10V D load resistance less than 1 KΩ Deviation or process setting Relay contact output:a 250 0.5A (AL-2), 3A (AL-1) 0~50 (32~122 ) Ambient humidity : 35~85% RH Deviation or process setting Relay contact output:a 250V 3A (Resistive load) Approx 310g Approx 310g Approx 235g.T REM OM 10 AL 2 LA/HA 8 6 5 3 2 T. 1 A TRANSMIT 20mA D AL 1 MAIN URRENT VOLTAGE 20 1 18 1 16 15 1 100 20VA 50/60Hz 12VA 13 H 12 L URRENT SOLIDSTATE 11 100-20VA 50/60Hz 12VA URRENT SOLIDSTATE 20 1 18 1 16 15 1 13 12 11 TRANSMIT AL-1 H L -20mA/D MAIN URRENT VOLTATE 10 8 6 5 3 2 1 T. A.T REM OM AL-2 LA/HA A 8 10 URRENT SOLIDSTATE T. 5 100 20 VA 50/60Hz 12VA 1 2 6 ALM 3 8 3A 250VA MAIN 5 10 3A 250VA T. 1

Setting of constants in display Signal on PV display Temp. range Name Description Setting range Initial set Temperature range in ramp -1~3200 (-1.~.) - Ramp Ramp(Rate) time setting 0~50 minutes - TEMPERATURE ONTROLLER * * * Proportional band Anti-reset windup Integral time Derivative time Set when proportional control is performed. Prevents overshoot and/or undershoot caused by integral action effect. Eliminates offset occurring in proportional control. Integral action turns OFF with this action set to O. Prevents ripples by predicting output change thereby improving control stability. Derivative action turns OFF with this action set to O. 1 to span ( ) 0.1~. ( ) 0~100 ( ) 0 to 3600 sec. 0 to 3600 sec. 20 ( ) 100 ( ) 20 sec. 60 sec. Hysteresis (in ON/OFF action) Displays hysteresis Set-Value for main output. 0.1~100.0 1 ( ) Proportioning cycle Displays manipulated output cycle(sec.). 1 to 100 sec. (0.1 to 100.0 sec.) Relay contact output : 20 sec. Voltage pulse output : 2sec. *Automatically set by Auto-tuning Alarm mode None Deviation high alarm Deviation low alarm Low alarm hold function of high/low alarm High alarm hold function of high/low alarm Hold function of high/low alarm Hold function of high alarm Process high alarm Hold function of low alarm Hold function of process high alarm and alarm Process low alarm High and low alarm Hold function of process low alarm 2

Operation Manual Normal mode Power supply (Power ON) (Input type) (PV) (SV) Display in Ramp function (Temp. range) Note In case of urrent and Voltage output, PID Auto-tuning does not operate by Autotuning key. Initial values of P.I and D are Programmed and you may use the unit in ordinary applications. If you are not satisfied with given values, you can change values of I and D slightly in normal mode by manual adjustment. TEMPERATURE ONTROLLER Temp. high limit Temp. low limit Output limit range:0~100% Manual output set (Select in SL- 3 mode to display this mode) range:0~100% Display in ON/OFF mode Display in HA function only Remote function mode(select in SL-3 mode to display this mode) Set 1 for operation SYSTEM SET P,A,I,D,: No display in ON/OFF mode Operates only in :1000 position. When flickers, Press to stop. Press and key simultaneously for 3 sec. to enter 3

Function set mode (System mode) (Alarm mode) (HA mode) (Retransmission output mode) TEMPERATURE ONTROLLER Note : Press and key simultaneously for 3 sec. and return to initial PV/SV mode in every step. Press key for 3 sec. in and return to.

: Input mode : Dead band of AL-1 initial value : 1 : Output terminal of AL-1 0: Indicator 1: ontroller 0: ON/OFF 1: PID 0: Direct control action for cooling 1: Reverse control action for heating MX -F Normal type 0: 1: 0: 0.1 resolution 1: 1 resolution No function key (Do not modify) 0: urrent output 1: Relay or Voltage, Pulse 0: None 1: AL-1 output AL-1 terminal(initial value) 2: AL-1 output AL-2 terminal 3: AL-1 output LA/HA terminal : Alarm-2 (Refer to alarm mode) initial value: Hold function of low alarm : Dead band of AL-2 initial value : 1.0 : Output terminal of AL-2 0: None 1: AL-2 output AL-1 terminal(initial value) 2: AL-2 output AL-2 terminal 3: AL-2 output LA/HA terminal : LA/HA function (None) (LA) (25A HA)(50A HA) TEMPERATURE ONTROLLER : Dead band of HA(A) 0: Remote input function 1: No remote input function 0: Manual output function 1: No manual output function No function key (Do not modify) 0: Ramp function 1: No ramp function : Output terminal of LA/HA 0: None 1: LA/HA output AL-1 terminal 2: LA/HA output AL-2 terminal 3: LA/HA output LA/HA terminal : Retransmission display : Input shift value range: within free scale range : Decimal point selection range : 0 ~ 3 (0001 000.0 in PV mode) : Span of free scale range: -1~3200-1/1 (-1~) -1/10 : Zero of free scale range: -1~3200-1/1 (-1~) -1/10 : Alarm-1 (Refer to alarm mode) initial value : Deviation high alarm (None) (PV) (SV) : Span of retransmission output range : 0~05 initial value :3500 (Do not modify) : Zero of retransmission output range : 0~05 initial value :500 (Do not modify) : Remote input calibration (Do not modify) 5

TEMPERATURE ONTROLLER Ramp function Ramp rate can be adjusted. (0~50 minutes) Set RAMP RATE T(urrent Transformer) 22 25 Time 13 31 Model T-25 Model T-50 PID Auto-Tuning (Valid in Relay and SSR output only) Press the key and key at the same time. Then, AT indication lamp flashes to start the Auto-tuning function. If Auto-tuning function ends, the AT indication lamp stops flashing automatically. When checking the auto-tuned value, press the key and conform in turn. When you want Auto-tuning function to be suspended, press the key and key simultaneously, then the AT indication lamp stops flashing to release Auto-tuning function. In this case P.I.D and ARW values are not changed (Maintain the value before the Auto-tuning starts). When you want to change the SV(set-value) during Autotuning, suspend it and perform PID control using the values before Auto-tuning starts. 16 3.5 ontrol loop break alarm(la) LA function starts to measure time from the moment that the PID omputed Value (Output ON time/cycle) become 0% or 100%, and detects the amount of Process Value change at each LA setting time, and determines by the amount of change whether LA is to be ON or OFF. When the status at a 100% PID computed value continues beyond the LA setting time, the LA turns ON if the measured-value(pv) does not rise by 2 ( ) or more. (In direct action, the above alarm turns ON if the measured-value does not fall by 2 ( ) or more. When the status at 0% PID computed value continues beyond the LA setting time, the LA turns ON if the measured-value(pv) does not fall by 2 ( ) or more. Remote input Set-value of controller can be set or changed from outside of the controller by direct voltage/current signal. ut the external signal should be input continuously. (Auto-tuning function is not operated while the external signal is set) Heater break alarm(ha) Set-value of HA to be set about 85% to input of T but the set-value should be less in case that the ratio of voltage variation is high. If several heaters are connected in parallel, the alarm may be turned ON even though one circuit is broken. In such a case, set the value of HA to be slightly high. No HA operates at O setting, but HA operates at 25.0 or 50.0 setting. 6