American Railway Engineering and Maintenance of Way Association Letter Ballot. Draft

Similar documents
Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

High Intensity LED Strobe Light - 10 Watt - 10~30 Volts DC - Permanent Mount - 14 Strobe Patterns

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

SolderSleeve Insulated Electrical Termination Devices

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION LIGHT, WARNING, 360 DEGREE LED BEACON PUBLICATION

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

Standard Specification for Hardened Steel Washers [Metric] 1

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

Standard Specification for Hardened Steel Washers [Metric] 1

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

PIASECKI AIRCRAFT CORPORATION TECHNICAL MANUAL OVERHAUL WITH PARTS BREAKDOWN AIRCRAFT OVEN - P/N X-006 Rev: B

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Owner s Guide and Installation Manual

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Catalog # Project. Comments. Prepared by

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

American National Standard

American Railway Engineering and Maintenance of Way Association Letter Ballot

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

signaling solutions from auer signal

SERVICING INFORMATION

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

High Mast Series HMAO HMSC

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

SECTION (16140) - WIRING DEVICES

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

SENJU SPRINKLER CO., LTD.

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

INTERNATIONAL STANDARD NORME INTERNATIONALE

Wig-Wag (C) Light-Flashing Module Improves Aircraft Visibility

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Installation Instruction Manual ILS-S

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

SF 26X TWO-WAY SOUNDFIELD OPEN BACK 8 OHM CEILING SPEAKERS SPEAKERS. Open back, infinite baffle design. 8 ohm nominal impedance

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

ROAM DCM Control Specification Guideline Division 16520

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

SECTION INTERIOR LIGHTING

Two Circuit Heavy Duty Burner Connector

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

STROBE POWER SUPPLIES - two outlets by Tomar Electronics

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Class 1 laser beam sensor safe for your eyes

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

INDEX. Installation recommendation

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

UNOFFICIAL COPY OF HOUSE BILL 1406 A BILL ENTITLED

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Applications. Standard Materials

Owner s Guide and Installation Manual

Victoreen Primalert 35 Area Radiation Monitor

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

e Bath Fan with Light User s Guide

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

5.0. Photoelectric Sensors. Technical Reference. Introduction

LED Elite BR Series 12W Dimmable Smooth BR K

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Jan05 Rev A EC

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

Product Specifications MaxLumen MRI LED Diffused Lighting

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Quadruple-beam photoelectric detector

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Installation Instructions Dual Fuel Ranges

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

Owner s Guide and Installation Manual

Transcription:

American Railway Engineering and Maintenance of Way Association Letter Ballot 1. Committee and Subcommittee: 36 2. Letter Ballot Number: 36-18-1:03.02.35 3. Assignment: 4. Ballot Item: MP 03.02.35: Recommended Design Criteria for Electric Light Unit for Grade Crossing Signals Including Light Emitting Units and Incandescent Lamps 5. Rationale:

2015 2019 Part 3.2.35 Recommended Design Criteria for Electric Light Unit for Grade Crossing Signals Including Light Emitting Units and Incandescent Lamps Reaffirmed 2015Revised 2019 (5 Pages) A. Purpose This Manual Part recommends design criteria for an electric light unit for grade crossing signals. B. General 1. Unit shall be designed so that the center of the roundels and side lights are 8-½ 1/2 in (21.59 cm) ±+/- 1-¼ 1/4 in (3.18 cm). below the center of the cross arm for 8-⅜ 3/8 in. (21.27 cm) diameter suspended light units, and 11-½ in (29.21 cm) 1/2 ±+/- ½ 1/2 in. (1.27 cm) below the center of the cross arm for 12 in. (30.48 cm) diameter suspended light units, conforming to Manual Part 3.2.50 Recommended Design Criteria for Crossarm for Suspended Lights for Flashing-Light Grade Crossing Signal Without Gate, Assemblies; and Manual Part 3.2.51 Recommended Design Criteria for Crossarm for Suspended Lights for Flashing-Light Grade Crossing Signal with Mast Mounted Gate, Assemblies. 2. Any gaskets or similar sealing provisions, shall be made of a material conforming to Manual Part 15.2.10 Recommended Functional Guidelines for Gasket Material Suitable for Circuit Controllers, Signal Cases and Other Signal Apparatus Housings, and should be fastened securely in place. 3. Unit shall be so designed that optical system parts may be cleaned without disturbing their adjustments. 4. The unit shall be designed such that either the main indication, or an indicator representing the main indication s operation, can be visually detected from 90 left and right of the unit. 5. Unit should be designed with a wire entrance at the point of attachment to its support. 6. Replaceable component parts of a unit shall be interchangeable with like parts of same manufacturer or supplier. 7. The light source shall be designed to operate in accordance with Manual Part 11.3.3, Section C.4.a. Recommended Design Criteria for Surge Withstand Capabilities of Electronic Signal Equipment for Signal Systems. - 1

Part 3.2.35 2015 2019 C. Housing 1. All unit housings, including inner sub-housings, shall be of a rigid material, which is not injuriously affected by atmospheric conditions or by changes in temperature as defined by Class B in Manual Part 11.5.1 Recommended Environmental Requirements for Electrical and Electronic Railroad Signal Systems. 2. All parts should be uniform in composition, clean, smooth and free from flaws, cracks, blowholes, shrinks and other defects. 3. Outer housings shall not project more than 3-1/2 in. (8.89 cm) to the rear of the centerline of the supporting fixture for 8-3/8 in. (21.27 cm) diameter light units and 4-1/2½ in. (11.43 cm) to the rear of the centerline of the supporting fixture for 12 -in. (30.48 cm) diameter light units. 4. Doors should open in front and be hinged at the side or bottom with a door-fastening device, which shall provide weatherproofing without change in optical alignment. Unit shall provide means of being locked sealed or secured against unauthorized entry. 5. Specific provisions shall be made for protecting against internal damage to wiring or internal components from moisture, heat buildup, contaminants, or insects, such as filtered breather openings, sealing, or other means. 6. A protective finish shall be applied to housings made of materials susceptible to corrosion, weathering, degradation from ultraviolet rays, or other elements identified in as Class B in Manual Part 11.5.1. D. Lamp Receptacles 1. Units using a single contact candelabra bayonet brass lamp receptacle shall be designed for electric lamps having a light center length of 1-1/4¼ in. (3.18 cm) and filament on centerline of the lamp base. The receptacle shall be adjusted on a rigid support and sealed in position at the factory so that the 1 /64 in (0.34 mm) precision lamp will have its filament at the focal point of the reflector. Receptacle shall be insulated from the housing. E. Reflector (For Incandescent Lamp Signals) 1. Reflector shall project parallel light rays through the effective diameter of the roundel used. - 2 Formatted: Superscript Formatted: Subscript

2015 2019 Part 3.2.35 2. Reflectors should shall be capable of meeting the following: a. Immerse for 24 hr. at room temperature in a solution composed of clean water and 20% by weight of sodium chloride. Remove from the salt solution and immerse in clean water at room temperature and gradually heat to the temperature of +171 F (+77 C) and maintained at that temperature for 4 hr. Remove from the water and place in dry air at +171 F (+77 C) for 4 hr. b. After the above test meets the requirements of section E.2.a.Following completion of the above test, the surface should shall show no signs of chipping, cracking or softening of the coatings. There shall be and no separation of the backing into layers or from the mirrored surface., and nthere shall be no appreciable change in the color of the backing or the reflecting surface. The reflector shall, and withstanding ordinary handling without scratching or chipping. F. Background and Hood 1. A background having not less than 20 -in (50.80 cm). diameter shall be provided for the unit. The background may be integral to the unit or designed to be mounted on the unit without requiring special tools. 2. Background color shall be matte or flat black (Color 17038, FED STD 595B) to provide maximum contrast with the red indication. Surface coloration shall be of a material for which reflectivity shall not change by more than 10% within 5 years under the environmental conditions specified in Manual Part 11.5.1, Class B, Recommended Environmental Requirements for Electrical and Electronic Railroad Signal System Equipment. 3. Background material shall meet the same durability requirements set forth in section C.21. and C.32. above. 4. A hood, not less than 8 in. long, projecting substantially at right angles to the body of the housing at least one-half way around the lens opening shall be provided. The hood may be integral to the unit or designed to be mounted on the unit without requiring special tools. 5. Hood color shall be matte or flat black (Color 17038, FED STD 595B) to provide maximum contrast with the red signal indication. - 3

Part 3.2.35 2015 2019 6. Hood material shall meet the same durability requirements set forth in Section C.21. and C.32 above.. G. Light Unit Performance 1. Units shall produce a uniform, red, light output which shall be highway crossing signal red and conform to Appendix Part FF, Manual Part 7.1.10 Recommended Design Criteria and Functional/Operating Guidelines for Signal Roundels, Lenses, Discs and Cones. H. Visible Distance 1. Visible distance is defined as the distance that the signal shall be clear and distinct under bright sunlight conditions, with the sun at or near the zenith. 2. Visible distance shall be determined when the signal is operated at the manufacturer's recommended voltage. Table 3235-3: Horizontal Axis and Downward Axis Values Shown in Distance (ft) Degree off Axis (Horizontal) 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 Lens Type: 30-15 188 469 938 1500 938 469 188 20-32 469 938 1500 938 469 70 13 13 31 188 313 500 1000 1200 1000 500 313 188 31 13 13 LED 30 30 30 45 120 480 1200 1500 1200 480 120 45 30 30 30 Degree Off AXIS (Downward) 0 5 10 15 20 30 Lens Type: 30-15 1500 945 465 195 20-32 1500 945 465 LED 1500 1200 480 120 45 30 I. Light Unit Electrical Requirements 1. Light Units shall be designed to operate when they are powered by either an ac source of 10 volts rms or dc source of 10 volts. Units shall be designed so as to not be damaged by any voltage up to 115% of the design voltage. - 4 Formatted: Centered

2015 2019 Part 3.2.35 2. Maximum current draw for the light unit shall not exceed 3.0 amps at any voltage up to the maximum rated operating voltage of the unit over the temperature range of -40 F (-40 C) to +160 F (+70 C). 3. Light Emitting Units other than incandescent lamp units should achieve 90% nominal light output (rise-time) within 75 milliseconds when voltage is applied to the unit and be at or below 1% nominal light output (fall-time) within 75 milliseconds when voltage is removed from the unit. 4. Polarity in dc-powered applications shall be internal to the unit and not require observance of polarity for connection to the existing housing terminals. 5. Electrical connections shall be insulated stranded copper wires of sufficient size for the maximum operating current of the light source. In no case shall the wiring be less than No.. 20 AWG, and shall be terminated with insulated, positive retention connectors compatible with the housing terminals. There shall be no requirement for intermediate connectors or other types of adapters. K. Identification 1. Beam deflection classification shall be plainly marked on the light unit. If a unit is suitable for use as a replacement for any of the beam deflection patterns, then the light unit should be marked with each deflection pattern, to which it conforms. 2. Light units shall be plainly marked "Highway Crossing Red". 3. Light unit body shall be plainly marked with the manufacturer's name or trademark, model number and date of manufacture. 4. Any components requiring vertical orientation shall be prominently and permanently marked with an indexing indication marked as "TOP". 5. When used in Canada, units shall meet Transport Canada Grade Crossings Standards, Appendix A Light Emitting Diode (LED) Signal Modules for LED Signal Modules at Grade Crossings and be labeled Meets Transport Canada Specification: 20022014. L. Binding Posts - 5

Part 3.2.35 2015 2019 1. Wire connections shall conform to Manual Part 14.1.11 Recommended Design Criteria for Binding Posts, Nuts and Washers, Details & Assemblies or Manual Part 14.1.2 Recommended Design Criteria and Functional/Operating Guidelines for Solderless Screw-Clamp Type or Screwless Cage-ClampSpring-Type Terminal Blocks Used in Wiring Signal Apparatus with Copper Wire Only. M. Dielectric 1. Dielectric requirements shall conform to Manual Part 11.5.1, Recommended Environmental Requirements for Electrical and Electronic Railroad Signal System Equipment, Class B, except for lamp receptacles that shall conform to Class E. - 6