MVE Chart Tech Tips PRODUCT INFORMATION. MVE CryoSystem Series

Similar documents
MVE Chart October 2014 Tech Tips

Tech Tips (April 2016) Product Information

Tech Tips. Chart MVE CryoSystem 6000 Full Auto. Serving Customers around the World. (March 2016) Product Information

MVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

MVE HEco 800 Series Freezers

Tech Tips (December 2016) Product Information

Chart Cryogenic Freezers. with MVE TEC3000 Controllers Operating and Maintenance Manual

MVE TEC 3000 TECHNICAL FREEZER MANUAL

Thermo Scientific Cryopreservation Storage Equipment

Biobank Series. CryoSmart Series. CryoMaster Series. CryoMajor Series. CryoTrans Series. CryoCarrier Series. CryoCenter Series

MVE TS Controller (Touch Screen)

Thermo Scientific Cryopreservation Equipment

MVE Variō Series with MVE Variō Pro Controller

Thermo Scientific Cryopreservation Equipment

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Chart MVE TS Controller (Touch Screen) TECHNICAL MANUAL

ECC-1 user manual and installation guide

Qingdao Innova Bio-Meditech Co.,ltd. ADD: No Jinshui Road, , Qingdao,China Website:

Liquid Nitrogen Storage Solution

7400 Series. CRYO Plus Liquid Nitrogen Storage System

Thermo Scientific Cryopreservation Equipment. Indefinite storage, infinite possibilities. your samples our obsession.

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

MVE CRYOGENIC FREEZER with MVE TEC 3000 TECHNICAL MANUAL

ECC-1 user manual and installation guide

201 Series Dryers Features and Benefits...3 Dimensions...4 How to Order...5 Product Specifications...5

The CAST-X 2500 is our most compact dual-tube model, a powerful and versatile mid-sized heater.

Vacuum Insulated Pipe

-86 C Ultra-Low Freezers. How It s Made. Matters

SOP SF SOP for LN2 Freezers

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Bio System Installation

Controlled Environment Equipment Solutions for the Lab

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

ph COOLING TOWER CONTROLLER

CURTIS GOLD CUP BREWER

Newsletter LUMC Places large order for several MVE1841 and MVE1536 vessels. Refurbish your existing storage vessels with CryoFill

REVCO MECHANICAL CRYOGENIC FREEZER

Biorack Series. S TATEBOURNE cryogenics. High Thermal Efficiency. 5 Year Vacuum Warranty. Cryobox Storage. Goblet Storage.

Owner s Manual Therma-Stor II Heat Recovery System

Installation Manual BCS2000/3000

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

Norcold Repair Guide for Ice Maker

FLT93 Installation, Operation and Troubleshooting Guide

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

Introduction. Brand introduction. Company profile

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

Understanding the Proper Design & Implementation of Elements in Creating Your Outdoor Living Experience. Presented By: Jeff Moyer & Matt Hanna

Refrigerant Recovery Unit, Model RRU134

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

Installation Manual BCS 1000/1500

PWEE Technical Data Sheet

EMKG Easy-to-use workplace control scheme for hazardous substances

Sporlan Valve Division Parker Hannifan/CIC Group

UHC-P /HCP * * Service, Parts Manual for 4, 2-Slot and Narrow Models. 24-Hour Service Hotline

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Warm Case Troubleshooting Guide 9/18/2014

UHC-P /HCP * * Service, Parts Manual for 4, 2-Slot and Narrow Models. 24-Hour Service Hotline

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L Technical Data Sheet

Wi Flow, Smart Flow and Easy Flow IVC Air Handling Units

Daily Refrigerator Medication Temperature Log Template

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

Salinas Valley Ammonia Safety Day. May 26, 2011 Salinas, CA

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

Corning LSE 6L Digital Water Bath

Chemistry - Tools for chemistry

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

CONTROL BE MADE CHANGES MAY NOT. Page 1

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

- EVAPORATION PANELS FOR ALL COOLING TOWERS ADVANTAGES MORE SECURE - MORE EFFICIENT - UNIVERSAL

Corning LSE Digital Dry Bath Heater

OPERATION MANUAL MODEL & ACCELEROMETER

Fast Track Troubleshooting

APC BC300 Series 40kW 208/450/480V User Guide

Image Key Part Number Description Substitution Qty.

2019 Orange County Black History Cultural Faire Commercial Food Vendor Information

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

JAG group microwave manual. (updated October ) Table of contents. 1 General information 2. 2 General safety rules 2. 3 The microwave reactor 3

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

Essentia Project Artica Platform No Frost 60 cm Appliances 2011

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

LIBERO PDF Logger for Cryogenic Container Monitoring

TruVision Bullet IR Camera Pocket Guide

FOR SERVICE TECHNICIAN S USE ONLY

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

Transcription:

Hi, just a reminder that you're receiving this email because you have expressed an interest in Chart Industries. Don't forget to add amy.mcdurmon@chartindustries.com to your address book so we'll be sure to land in your inbox! Visit our website to view MVE Chart Tech Tips: http://www.chartbiomed.com/literature_resources/tech_tips.aspx You may unsubscribe if you no longer wish to receive our emails. MVE Chart Tech Tips In This Issue Product Information Helfpul Hints / FAQs Accessories PDF Version To view the PDF version of Tech Tips, click here. Join Our List PRODUCT INFORMATION MVE CryoSystem Series September 2015 The MVE CryoSystem Series combines the benefits of low nitrogen consumption with mid range vial capacity to meet the diverse needs of today's professionals worldwide. The lightweight and low space demands of these containers make them the most economical units in their class. Features Include: * Designed for large capacity storage * Low liquid nitrogen consumption * Convenient lightweight package http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 1/6

Note: Static evaporation rate and static holding time are nominal. Actual rate and holding time will be affected by the nature of container use, atmospheric conditions, and manufacturing tolerances. Note: Normal Working Duration is an arbitrary reference, to estimate container performance under normal operating conditions. Actual working time may vary due to current atmospheric conditions, container history, manufacturing tolerances and any individual patterns of use. HELPFUL HINTS / FAQ's Q: What basic troubleshooting steps can one take to determine why a freezer is overfilling? A: Reference the TEC 3000 Technical Freezer Manual Troubleshooting Steps on page 128. 1. Verify LN2 source pressure is 22 35psi (1.5 to 3.4 bar) 2. Verify freezer lid is not sealing against freezer neck 3. Verify the resistance of the fill solenoid 50 to 70 ohms (single) dual 25 to 35ohms (parallel); replace if necessary; reference page 121 of the TEC 3000 Technical Freezer Manual http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 2/6

4. Verify the freezer level sensing line is not blocked; reference page 126 of the TEC 3000 Technical Freezer Manual Q: If it is suspected that one of the electrical components is not operating properly, what are the resistance values to check during an evaluation? A: Below is a list of specifications for select items normal resistance values 1. Fill Valves (Dual 24 VDC): 30 35 ohms 2. Fill Valve (Singular 24 VDC): 60 70 ohms 3. Bypass Valve: 60 70 ohms 4. Bypass Sensor: a) Room Temp: 1,000 1,100 ohms b) Cryogenic Temp: 200 300 ohms 5. Humphrey 3 way: 140 145 ohms 6. Temperature Probes a) Room Temp: 1,000 1,100 ohms b) Cryogenic Temp: 200 300 ohms ACCESSORIES SUC Canister Racks If storing SUC canisters (PN 9710491) in freezers, Chart offers two racking options to conserve space. These racks work as a two stage shelf, which allows two layers of racks to be stored in the freezer. One of the available racks holds two SUC canisters, PN 11392644, storing one over the other. The second, PN 11395896, holds eight of the canisters, storing four on each shelf. Part Number Number of SUC Canisters (PN 9710491) 11392644 Holds two SUC Canisters 11395896 Holds eight SUC Canisters PN 11395896 http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 3/6

PN 11392644 MVE Freezer Series Optional Vapor Platforms Chart offers optional vapor platforms for the MVE Series. When ordering, please keep in mind that vapor platforms occupy approximately 4 to 5 inches of the freezer's usable space, that will affect the necessary rack size. Freezer Vapor Platform Part Number MVE 205 10544837 MVE 510 10544853 MVE 616 and MVE 616 Cabinet Series 11509726 MVE 808 10544861 MVE 1318 10544896 MVE 1426 and MVE 1426 Cabinet Series Upcoming Events Trade Shows 10544888 MVE 1839 10544909 We will be present at the following trade shows and would love to see you at our booth! World Dairy Expo September 29 October 3 Madison, WI Booth # 226 227 ESBB September 30 October 2 London, England ASRM October 17 21 http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 4/6

Baltimore, MD Booth # 101 AABB October 24 27 Anaheim, CA Booth # 1274 Medica November 18 21 Dusseldorf, Germany World Stem Cell Summit December 10 12 Atlanta, GA Contact Us For ordering information contact Customer Service: United Kingdom +44 (0) 1189 367060 France +33 (0) 05 61 42 94 11 Germany +49 (0) 202 739 55429 Italy +39 049 784 0142 customerservice.europe@chartindustries.com Australia/New Zealand +61 2 9749 4333 customerservice.australia@chartindustries.com Asia/Pac Rim 770.721.7759 csasia@chartindustries.com The Americas 770.721.7759 US Toll Free 800.482.2473 customerservice.usa@chartindustries.com For technical information contact Technical Service: United Kingdom +44 (0) 1189 367060 France +33 (0) 05 61 42 94 11 Germany +49 (0) 202 739 55407 Italy +39 049 644 498 techservice.europe@chartindustries.com Asia/Pac Rim +61 2 9749 4333 techservice.asia@chartindustries.com The Americas 770.721.7759 techservice.usa@chartindustries.com US Toll Free 800.482.2473 techservice.usa@chartindustries.com www.chartindustries.com/life Sciences.com http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 5/6

http://campaign.r20.constantcontact.com/render?ca=3a1f0cea-0439-45fe-94dc-60a6dddfe30d&c=c774f3c0-5287-11e3-9268-d4ae527b6fcc&ch=c80302f0-5287-11e3 6/6