Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

Similar documents
Emergency Lighting User's Guide

Emergency light. Safe solutions

Compliance Guide 2015 NFPA 101 LIFE SAFETY CODE EXIT STAIR PATH MARKINGS. for Ecoglo Photoluminescent Markings to meet the requirements of

Emergency Lighting: what, when & how? Richard Caple MSc MSLL Lighting Applications Manager

licht.wissen 10 Free Download at Emergency Lighting, Safety Lighting

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

COSINE DEVELOPMENTS Reg. No. IT 1637/97

Dublin airport - Dublin, Ireland

The SLL Lighting Handbook

New Fire Safety Order

Emergency Lighting Design

TES-1339 INSTRUCTION MANUAL

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Element C3.5 Means of Escape

Technical reference Reference & design

Lighting in the workplace is it just about vision?

Lighting Laboratory. Ensuring the performances and compliance of your lamps and luminaires

Lindsey Beane. Executive Summary

Optics & Radiometry Laboratory

Hospitality. Emergency Lighting

Fast. Precise. Versatile. UL Lighting Sciences

New GuideLed safety luminaires

THE EFFECTS OF SMOKE ON PEOPLE S WALKING SPEEDS USING OVERHEAD LIGHTING AND WAYGUIDANCE PROVISION

w w w. l e t t h e r e b e l i g h t. c o m. a u

EMERGENCY LIGHT SERIES

Lighting Guidelines. Planning Services Department Corporation of the Municipality of Clarington

Maintenance of Fire Systems

AS/NZS :2006 Interior and workplace lighting - Part 1: General principles and recommendations

Emergency Lighting. This is a free 7 page sample. Access the full version online. Irish Standard I.S. 3217:2008

Selecting And Applying Emergency Lighting Systems

FIRE SAFETY LOG BOOK

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

ISO Clean Version of Revised Working Draft (N 348)

MONTHLY SAFETY INSPECTION REPORT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A Guide To BS Understanding the selection, spacing & siting of detectors

ISO INTERNATIONAL STANDARD

Main Lobby Area (North Vestibule thru South Vestibule):

Guidance Note. Guidance Document for Testing and Maintaining Self-Contained Emergency Lighting and Luminaires

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

CELMA-ELC Guide. Joint PLDA European Lighting Industry Forum. PLDC 2011, 19 October in Madrid. Peter Dehoff, CELMA (FEEI & ZVEI / Zumtobel)

Low Location Lighting

Lighting Concepts: Residential

Advanced Lighting For Office

RETAIL SAFETY AUDIT EMPLOYEE SAFETY

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

Photoluminescent emergency pathway marking systems bring a new level of safety to manufacturing environments.

All NIGHTBRIGHT photoluminescent signs are non-electric, non-toxic and nonradioactive.

Saving on maintenance and energy

The fundamental requirements for lighting for healthcare could be as follows:

Fire Safety Register

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

ISO INTERNATIONAL STANDARD

SECTION INTERIOR LIGHTING

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Requirements of EN 1838: illuminance of 5 lx for safety equipment

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

EMERGI-LITE An authoritative guide to emergency lighting & central power systems

DISTRIBUTION PANEL BOARDS; NEW CONSTRUCTION. Subpart 1. Circuit index. All circuits in light and power

Dentistry Operating lights

ENERGY EFFICIENT LED SOLUTIONS

How Photometric Design Enhances Energy Savings and Asset Management

Lighting at work. HSE Books

Dear Customer. Section Old F8 February 2014 Amendments to F8. Replace with new title page and document history pages 1 2B

Lighting. at Work HSG 38

ISO CIE S 020/E

FR-A180 FR-A360. Occupancy detector. Use

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

High Efficiency LED Panel Lights

NEW ENHANCED CAPITAL ALLOWANCE EXPLAINED NEW ECA EXPLAINED HELEN LOOMES 2013/2014 SLL MASTERCLASS

HRS Hand Rail System 1

and Contrast Manual The Colour, Light WILEY-BLACKWELL Designing and managing Geoffrey Cook inclusive built environments Keith Bright

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES EXTERIOR IMPROVEMENTS DIVISION 32 Exterior Lighting

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Sylproof Superia LED G2

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Lighting Design Guide Mains Lighting. Lighting Design Guide Mains Lighting. Mains Lighting Design Guide

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

Lum. Flux** [lm] 6500 K 1700 lm

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH GENERAL INDUSTRY STANDARDS

Paper Modern LED Light Solutions for Safe Navigation on Inland Waterways

The Optimum LED Headlight. I. Company Introduction Product Features Product Certification

Avenue Metro. The evolution of an icon. UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

Design Considerations of LED based Visible Notification Appliance SUPDET 2015

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

ISO Submissions on Revised Working Draft (N 348)

PD-32: Light Pollution

COMMERCIAL LIGHTING DESIGN GUIDE

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

Light expertise down to the last detail. Many lights are shining with Wacker Neuson. Overview of all lighting products.

Transcription:

Safety Lighting Prof. Grega Bizjak, PhD Laboratory of Lighting and Photometry Faculty of Electrical Engineering University of Ljubljana Safe also without electricity Since it is practically impossible to find a way out of the unknown building in the dark, it is compulsory to provide adequate security lighting in the event of power failure. Safety lighting allows us to: safely finish the work, quickly and safely leave the building and avoid panic. Standards SIST EN 1838: 2011 Lighting applications emergency lighting ISO 30061 (2007) Emergency lighting CIE S 020 (2007) Emergency lighting

Emergency lighting Lighting in the building can be divided into: general lighting, emergency lighting. Emergency lighting Emergency (and safety) lighting ensures that a minimum level of brightness is guaranteed after a failure of general lighting. That mean it needs its own independent source of electrical energy (batteries, rechargeable batteries (individual, group or central), power generator and/or special fire proof electric installation. Emergency lighting Emergency lighting is used as the umbrella term for mains-independent lighting and can be divided into: standby lighting, safety lighting.

Standby lighting Standby lighting is mainsindependent light that is installed where no hazard for employees is anticipated. Usually it is used for normal continuation of work in the event of a power failure. Standby lighting For example in large stores, we do not want to stop the work in the event of a power failure. Standby lighting usually uses general lighting luminaires and diesel generator as a power source. Safety lighting Safety lighting has only safety tasks and is intended to: allow potentially hazardous work to be safely stopped or finished, allow persons to safely and quickly leave the affected premises or building and to prevent the outbreak of panic in areas where there is a greater number of people present.

Safety lighting Safety lighting can be divided into: safety lighting of escape routes, anti-panic safety lighting safety lighting for particularly hazardous working areas (places). Overview of emergency lighting Emergency lighting Safety lighting Standby lighting Escape route safety lighting Anti-panic safety lighting Safety lighting for particularly hazardous workplaces Safety lighting Main features of safety lighting: luminaires need to be mounted at least 2 m above floor level; escape signs need to be illuminated; if emergency exit is not directly visible, escape signs need to be positioned along escape route; safety luminaires need to be installed in proper places.

Isues with safety lighting Visual conditions with safety lighting are not the same as with general lighting: visual acuity vision of colours adaptation time Escape route safety lighting The purpose of the escape route safety lighting is: to allow safe escape from the area and/or building; to allow the identification of safety signs; to enable rough orientation in space and to enable the identification of obstacles on the route. Escape route safety lighting To properly mark the escape route following is used: escape sign luminaires or illuminated escape signs for marking the escape route, luminaires for illuminating the escape route and escape route plans.

Escape route safety lighting Standard SIST EN 1838 gives different requirements for escape route lighting: needed minimum illuminance; minimum uniformity of illuminance; proper glare limitation; minimum colour rendering index; minimum operating time in minimum power-up delay. Escape route safety lighting: requirements Illuminance E min =1lx Minimum horizontal illuminance on floor level (preferably no more than 2 cm high) for escape routes up to 2 m wide. Can decrease to 50 % at a distance of 50 cm. Escape route safety lighting: requirements Uniformity of illuminance E max : Emin 40 :1

Escape route safety lighting: requirements Glare limitation In the case of horizontal escape routes, luminous intensity must not exceed certain limits at any azimuth angles between 60 and 90. For other escape routes the limits must not be exceeded at any angle. Escape route safety lighting: requirements Glare limitation The limiting luminous intensity depends on the height of the luminaire: height (m) up to 2,5 2,5-3,0 3,0-3,5 3,5-4,0 4,0-4,5 over 4,5 lum. intensity (cd) 500 900 1.600 2.500 3.500 5.000 Escape route safety lighting: requirements Colour rendering index R a 40 The colour rendering index of the light sources in luminaires bust be at least 40 so that the colours of safety signs can be recognized.

Escape route safety lighting: requirements Power-on delay 50% of illuminance within 5 seconds, 100% of illuminance within 60 seconds. The power on-delay of luminaires with instantaneous 100% luminous flux should not be more than 15 second. If the full luminous flux is not achieved right after the power-on, upper limits need to be taken into account. Escape route safety lighting: requirements Rated operating time t min 1 h The needed illuminance must be maintained at least for 1 hour or in some cases at least for 3 hours (depending on data in safety assessment documents) Escape route safety lighting Where escape route luminaires should be placed: along the escape route (to achieve needed E); at exit doors; near stair, single steps or any other change of level; at emergency exits and safety signs; at any point of change of direction; at any point where corridors or aisles cross; near any first aid post, fire-fighting facility or alarm device; outside the building up to safe distance from each exit.

Anti-panic lighting The purpose of antipanic safety lighting: To prevent a possible outbreak of panic in areas with a lot of people; To enable people to find escape routes. Anti-panic lighting Main features: luminaires should be directed directly downwards; lighting should shed light on the potential obstacles to a height of 2 m above the ground. Anti-panic lighting: requirements Minimum illuminance E min = 0,5 lx Horizontal illuminance at the floor level need to be at least 0,5 lx. The total area of the room is taken into account except the 0,5 m wide stripe around the walls.

Anti-panic lighting: requirements Uniformity of the illuminance E max : Emin 40 :1 Because of persistence of vision, the ratio of highest to lowest illuminance should be no greater than 40:1; this avoids excessive differences in brightness that interfere with the visual task. Anti-panic lighting: requirements Glare limitation Glare limitation requirements are the same as for escape route safety lighting. Luminous intensity must not exceed certain limits at any azimuth angles between 60 and 90. Anti-panic lighting: requirements Glare limitation Allowed luminous intensity is the same as at the escape route safety lighting. height (m) up to 2,5 2,5-3,0 3,0-3,5 3,5-4,0 4,0-4,5 over 4,5 lum. intensity (cd) 500 900 1.600 2.500 3.500 5.000

Anti-panic lighting: requirements Colour rendering index R a 40 Colour rendering index of light sources should be at least 40 so that safety signs and their colours can be clearly identified. Anti-panic lighting: requirements Power-on delay within 5 seconds: 50% of illuminance, within 60 seconds: 100% of illuminance Anti-panic safety lighting should provide 50% of the required illuminance within the first 5 seconds and 100% in 60 seconds. Anti-panic lighting: requirements Rated operating time t min 1 h Anti-panic safety lighting must provide appropriate conditions (at least on escape route areas) for a minimum of one hour (three hours).

Safety lighting for hazardous work areas The purpose of this type of safety lighting is: to enable safety for workers, which are located in potentially hazardous areas (acting machines, containers of hazardous liquids... Safety lighting for hazardous work areas The main feature: workers who operate machines and processes or control them, must be able to stop these machines and/or processes safely and without putting in danger themselves or other employees. Safety lighting for hazardous work areas: requirements Minimum illuminance Emin = 10% En > 15 lx Minimum illuminance on the working area must be at least 10% of the maintained illuminance required for the task or at least 15 lx.

Safety lighting for hazardous work areas: requirements Stroboscopic effect Stroboscopic effect is not allowed As rotating machines might be present, safety lighting may not have the stroboscopic effect (recommended use of incandescent lamps or fluorescent lamps with electronic ballasts). Safety lighting for hazardous work areas: requirements Uniformity of illuminance E max : Emin 10 :1 Required uniformity of illuminance (ratio between the maximum and minimum luminance) on the illuminated area should not exceed the ratio of 10: 1. Safety lighting for hazardous work areas: requirements Limitation of glare Also in this case the glare is limited with the help of maximum luminous intensity of the luminaires. Luminous intensity must so not exceed certain limits at any azimuth angles between 60 and 90.

Safety lighting for hazardous work areas: requirements Glare limitation The maximum permissible luminous intensity values are in this case two times higher than in case of escape routes and anti-panic safety lighting: height (m) up to 2,5 2,5-3,0 3,0-3,5 3,5-4,0 4,0-4,5 over 4,5 lum. intensity (cd) 1.000 1.800 3.200 5.000 7.000 10.000 Safety lighting for hazardous work areas: requirements R a Colour rendering index 40 Also in this case it is necessary to provide a colour rendering index of at least 40, or more. It is important to ensure the proper distinguishing of safety colours at the machines and devices. Safety lighting for hazardous work areas: requirements Power-on delay 0,5 s Needed illuminance must be continuously present (continuously powered-on safety lighting) or has to be achieved in 0.5 seconds (in any case).

Safety lighting for hazardous work areas: requirements Rated operating time As long as a hazard exists Safety lighting for hazardous work areas should be powered-on at least until all potential hazards are removed (all the machines stopped,...). Safety lighting for guidance The features of this type of safety lighting is: if there is a danger that people would lost orientation because of the smoke in the room the safety lighting for guidance can be very helpful. safety lighting for guidance is mounted on the floor level or near the floor and runs along the escape routes (irrespective of whether it is straight or curved). electric or phosphorescent systems can be used. Safety lighting for guidance In smoke filled corridors only the floor mounted dynamic escape routing luminaires are visible.

Safety lighting for guidance Examples of use Safety lighting for guidance Other solution: pointing to the escape exit with laser light. Safety signs Standards: ISO 3864-1 (photometry) ISO 7010 (design)

Safety signs: colours Safety sign is made with two colours: safety colour tell us the purpose of the sign, contrast colour is used to draw a clearly visible symbol. Safety signs: colours Signs for prohibitions: safety colour: white with red stripe contrast colour: black Safety signs: colours Signs for warnings: safety colour: yellow (with black stripe) contrast colour: black

Safety signs: colours Signs for commands: safety colour: blue (with white stripe) contrast colour: white Safety signs: colours Signs for safety: safety colour: green (with white stripe) contrast colour: white Safety signs: colours Signs for fire fighting equipment: safety colour: red (with white stripe) contrast colour: white

Safety signs: colours Markings for dangerous zones: safety colour: yellow or red contrast colour: black or white Safety signs: illuminantion Based on the used principle for providing adequate brightness (luminance) of the safety signs, these can be: illuminated or back-lit. Safety signs: requirements Colours need to be according to ISO 3864-4: Green: x=0,026, y=0,399 White: x=0,305, y=0,315

Safety signs: requirements Luminance: average luminance of green safety colour: 2 cd/m 2 average luminance of the sign as a whole: 5 cd/m 2. Safety signs: requirements Uniformity of luminance (of green white surfaces): L max : Lmin 10 :1 Luminance and its uniformity are key criteria for judging a good safety sign and thus the safety it affords. Safety signs: requirements 5 :1 L white : L 15:1 green Luminance contrast between green and white surface:

Safety signs: requirements Power-on delay (back-lit signs): within 5 seconds: 50% of luminance, within 60 seconds: 100% of luminance Safety signs: requirements Height of the sign: h = viewing distance distance factor Safety signs: requirements Height of the sign (back-lit sign): h = 30 200 = 0,15m = 15cm

Safety signs: requirements Height of the sign (illuminated sign): h = 30 100 = 0,30m = 30cm Safety signs: requirements Good visibility and readability: d v d v = 1 7 Safety signs: back lit, illuminated or retro-reflective? Back-lit and illuminated signs have some advantages compared with the retroreflective ones: colour, operating reliability, luminance, height or viewing distance.

Safety signs: back lit, illuminated or retroreflective? at general lighting after failure of general lighting Safety signs: back lit, illuminated or retroreflective? after 10 minutes after 30 minutes Safety signs: meaning Escape route Escape route

Safety signs : pomen Meeting point Safety exit Luminaires for safety lighting Special safety lighting luminaires Luminaires for safety lighting General lighting luminaires with double lighting source: usual one for main voltage and safety lighting ones for DC voltage

Luminaires for safety lighting Luminaires for general lighting with integrated safety lighting module. The same lighting source is used in both cases. Luminaires for safety lighting Safety lighting luminaires differ depending on operation locations: ceiling mounted luminaires for escape routes; wall mounted luminaires for escape routes; ceiling mounted luminaires for anti-panic safety lighting; ceiling mounted luminaires for safety lighting for dangerous working areas;. Luminaires for safety lighting Example of ceiling mounted luminaire for escape routes.

Luminaires for safety lighting 1 lx at wall 0.5 Lux + 0.5 Lux Providing needed illuminance on the escape route with the ceiling mounted luminaires. 1 Lx min. on axis of escape route Distance from wall Distance between two luminaires Luminaires for safety lighting Example of wall mounted luminaire for escape route safety lighting. Special reflector for proper distribution of luminous flux (luminous intensity) Luminaires for safety lighting Safety lighting of escape route with wall mounted luminaires.

Luminaires for safety lighting Example of ceiling mounted luminaire for anti-panic safety lighting: it has lighting source with larger luminous flux and larger battery. Luminaires for safety lighting Distance between Distance from the wall luminaires 0.3 0.3 Distance from the wall 2 2 Distance between luminaires Use of ceiling mounted safety luminaires for antipanic safety lighting. 0.5 Lx Isolux curve 0.5 m from wall 2 2 0.3 0.3 Luminaires for safety lighting Example of ceiling mounted luminaire for safety lighting of hazardous working areas.

Luminaires for safety lighting Light sources Electric energy sources Single local battery: 1,2 to 3,6 V/cell life: 4 years

Electric energy sources Central power supply system (battery) with limited output (LPS): 24 to 48 V Lead battery (2V/cell) Life: min. 5 years, recommended 10 years max. 1500 W (1 hour) Electric energy sources Central power supply system (battery) with non-limited output (CPS): any voltage (pref. 216 V) Lead battery (2V/cell) Life: min. 10 years Electric energy sources Generator unit with rapid start.

Modes of operation Luminaires for safety lighting can be operated in three modes: non-maintained operation, maintained operation and switched maintained operation. Additional features Power failure simulation: A power failure simulation test button or a connection to a remote test system needs to be located on every single-battery luminaire or on the central power source for safety services. Manually operated test buttons must automatically return to their original position or be equipped with lock switch. Additional features Signaling the status of the luminaire:

Additional features Switch off possibility: in case safety lighting is not needed (e.g. empty building) it can be switched off to safe battery content. Safety lighting systems Safety lighting systems and central monitoring systems Safety lighting systems Functions of central monitoring system: control of individual luminaires (light source, battery,...); function tests (simulation of a power failure); switching-off part of luminaires when part of the building is not in use or during the day; logging and storing data on condition and faults in the system.

Checking of safety lighting systems Safety lighting must be maintained and controlled regularly! Checking of safety lighting systems Routine checking of safety lighting system: all luminaires must have installed functioning light sources and source of electric energy; LPS and CPS battery systems must be regularly (daily) tested; single local batteries should be tested at least once a week; the entire operation of safety lighting system should be tested at least once a month; it is required to keep appropriate log records on all performed tests and interventions on safety lighting system. Measurement of safety lighting Measurements on safety lighting system: verification of the correctness of the project; assessment of the current state of luminaires and safety lighting system; assessment of a new state of the system after alterations and repairs; identifying characteristics of luminaires and parts of the system when selecting appropriate components for safety lighting.

Measurement of safety lighting What needs to be measured: power-on delay times and/or times in which illuminance reaches 50% and 100% of needed illuminance; rated operating times of individual luminaires; illuminance on escape routes in places with anti-panic safety lighting or on hazardous working areas; luminous intensity distribution (connected with glare) - this measurement is usually carried out by the manufacturer; voltage of sources and the ambient temperature due to their impact on the outputted light flux of light sources. Measurement of safety lighting Needed equipment: calibrated temperature measuring device; calibrated volt-meter calibrated stopwatch; calibrated illuminance-meter (lux-meter). Lux-meter must have at least accuracy of class B (total error <10%, error of V(λ) <6%), it must have a probe with diameter of at least 30 mm embedded in the cardan joint or equipped with level control. It must be calibrated every 2 years. Measurement of safety lighting Preparations for measurements: determination of characteristics of space and of safety lighting (escape routes safety lighting, antipanic safety lighting,...); determination of activities that take place in a space and determination of the hazardous working areas; determination of the overall state of safety lighting (in operation, cleanliness,...) selection of measurement points.

Measurement of safety lighting Selection of measuring points along the escape route: Illuminance on escape route is measured in symmetrically placed points along the axis of the escape route (escape route wider as 2 m). If there is only one luminaire on the route, illuminance is measured under the lamp and where required to obtain E min. d d/4 d/4 d/4 d/4 Measurement of safety lighting Measuring points for antipanic safety lighting: Measuring points in a room are selected by means of an appropriate network. Care should be taken that the network raster does not coincident with the luminaire raster. Illuminance is measured on the floor (max. 20 cm high, preferred not more than 2 cm high). Measurement of safety lighting Measuring points for safety lighting of hazardous working areas: Illumination of hazardous working areas should be measured on concrete working areas as specified in SIST EN 12464-1. For larger working areas a similar network raster can be used as in the case of anti-panic safety lighting.

Measurement of safety lighting Procedure for measurement of safety lighting: measurement of the temperature in the room (particularly important when fluorescent lamps are used); safety lighting is switched on and the power-on delay time is measured (or time for luminous flux increase); measurement of the illuminance at selected points. The measurement is made with only safety lighting on. It is also necessary to exclude the contribution of natural light (measurements at night); measurement of the battery voltage; production of the appropriate report. You should remember Security lighting is a very important part of the building with views of the safety of its users. Planning for security lighting should take into account all the specificities of the building. Security lighting should be regularly checked and maintained. end: Questions?