Shown here with optional quick-disconnect cable kit.

Similar documents
Quick-disconnect cables. Adjustable mounting brackets

Safety Light Curtains Area Access Control

GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

GuardShield PAC Type 4 (Perimeter Access Control) Safety Light Curtain User Manual

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Ultrasonic Proximity Sensor

Class 1 laser beam sensor safe for your eyes

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

General Specifications

INFRARED MODULATED BARRIERS

FF-SYB14, FF-SYB30 and FF-SYB50 Series Safety Light Curtains. FF-SYB234 Multibeam Systems for Access Detection

2 General Application Photoelectric Sensors

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

/ / 2018

Class 1 laser beam sensor safe for your eyes

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

PHOTOELECTRIC AMPLIFIER SERIES

Class 1 laser beam sensor safe for your eyes

2 General Application Photoelectric Sensors

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Dräger Polytron Pulsar 2 Open Path Gas Detector

Line Smoke Detector LRMX

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Red Crane Warning Strobe Laser - 5mW Laser - 1 Flash Per Second - Red Line on Floor - IP54-120/240

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

GuardShield Safe 2 and Safe 2 PAC Safety Light Curtains User Manual

ACTIVE INFRARED BARRIER

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Installation And commissioning manual. Series S Double Beam 1/16

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

MA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

2 General Application Photoelectric Sensors

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Infrared Single Light Barrier. Mounting Instructions DO560

Ultrasonic Reflective Sensor

CM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity

P E R I M E T E R m i n i c a t a l o g u e

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Flameproof Type Light Curtain Type 4

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

ISIS SAFETY SYSTEM Installation guide

4 Channel Contact Closure SFP DIN Fiber Link System

Power Supply Display Module PSDM. Installation and Operation Manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors. R Series

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Laser Collimated Beam Sensor

Ultrasonic Reflective Sensor

BARRIERE & SENSORI BARRIERS & SENSORS

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Sensor Interface Module Installation/Operation Instructions

Safety Photo Beam UL MONITORED DEVICE

XPSLCM1150 Safety light curtains mute module User s Manual

CATALOGUE LASER POINTERS

Retroreflective sensor with polarization filter

Retro-reflective Sensing range: 0mm to 2000mm

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

DUAL OPTIC. Installation manual

English. Series. Installation and Use Manual

E3M-V. Mark Sensor. Applications

AC/DC Power Supply and Battery Charger Installation and Maintenance

Twin Photobeam Detectors Manual

Safety & Signaling Mats. Sensing Bumpers Pressure-sensitive actuation with a large, cushioning surface that protects both. personnel and equipment.

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

4-Channel Contact Closure Fiber Link Card System

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Topscan G3 Presence detector for automatic doors

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers


Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

UV - flame detector dual fuel burners for intermittent burner operations

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

VA G 052 S

LED LANDSCAPE LIGHTING

Plug-in Base, Long Range Sensor E3B2

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

5.0. Photoelectric Sensors. Technical Reference. Introduction

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

200mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - 250V DC

Transcription:

File No. L90200 Description BeamSafe Long-ange, Single-Beam Safety Control 200 foot (60 meter) range Four possible transmit codes eliminate crosstalk from multiple units in the same area Signal strength indicator and integral Gun Sight allow easy installation No interconnecting cables required, which speeds longrange installations Three models available: elay output with 24VDC power input elay output with 85 to 250 VAC power input Solid-state output with 24VDC power input Switch selected Automatic Start or Start/estart Interlock operation Lens heater Shown here with optional quick-disconnect cable kit. The STI BeamSafe is a longrange single-beam safety control designed for perimeter and access guarding. Diverse redundant microprocessor design provides safe, control reliable operation. A BeamSafe system consists of one transmitter and one receiver. No interconnecting cables or separate control enclosure are required. Mounted on the receiver, four separate visible indicators provide instant information on system clear, blocked or interlocked status as well as signal strength. Additional diagnostic indicators on the receiver provide codes to assist with trouble shooting. Output options include redundant solidstate or force-guided relays located in the receiver. Immunity to weld flash and ambient light are enhanced by coding the infrared beam. This feature also eliminates interference from other BeamSafe units installed in close proximity. A tight beam angle reduces problems associated with reflective surfaces. The Beamsafe s builtin lens heater is effective in environments where condensation may form on the transmitter or receiver lens. Adjustable mounting brackets allow easy alignment Designed in accordance with IC61496, N954-1 and ANSI B11.19 C108

Applications Perimeter Guarding Shown here with one transmitter and receiver. Mirrors are used to form two beams and also turn corners. 1 to 59 ft 0.3 to 18 m Long-ange Perimeter Guarding Two transmitter/receiver pairs using two mirrors and STI mounting stands to direct the beam around a corner. 1 to 176 ft 0.3 to 53 m Double Bounce This configuration guards access to hazardous work cells. One transmitter and receiver combined with two STI 4-inch mirrors and mounting brackets. 1 to 75 ft 0.3 to 23 Specifications Performance Protected Height: Single Beam Operating ange: 1 to 200 feet (0.3 to 60 meters) Beam Diameter: 1.2 inches (31mm) Maximum esponse Time: <0.035 seconds for all models DC Models Input Power: 24 V ± 10% (negative ground) /elay Output: 0.45 A Max /SS Output: 0.80 A Max : 0.17 A Max AC Models Input Power: 100 to 230 VAC ±10%, 50/60 Hz; 115 VAC: 230 VAC: 16 VA 25 VA 115 VAC: 10.5 VA 230 VAC: 20 VA ffective Aperture Angle: 2.5 maximum half angle Frequency Selection: 4 non-interfering codes, all models Diagnostics: Built-in diagnostic indicators Output: elay Output Version: Two relays with force-guided contacts, NO rated 4 Amps at 115 VAC, 200 Watts switched power (2.0kVA). DC Loads are limited to 100V maximum. stimated mechanical life is 50,000,000 operations. lectrical life is typically 1,000,000 operations at 200VA. Auxiliary Monitoring elay: 400V AC/DC maximum, 0.1A; total power 180 mw maximum. Solid-State Output Version: Two safety solid-state relay outputs. ach output sources (PNP) up to 0.25 Amps at 24 VDC. Construction: Polyester powder-painted aluminum body. Anodized aluminum end-caps. Operating Temperature: 0 to 55 C Protection Category: NMA 4 / IP65 Agencies: Designed in accordance with IC 1496, type 4 and UL/CSA requirements. Specifications subject to change without notice. 45 Mirror 45 Mirror For the Latest Information Try Our Fax Back System at 1/916/431-6544 On the Internet: www.sti.com -mail: sales@sti.com C109

Dimensions BeamSafe, elay Output Version 2.93 74.3 2.36 60 4.25 108 C B BeamSafe A F. 6.25 6.64 158.8 168.7 F. BeamSafe F1 F2 MOUNTING HOLS (4) FO ALTNAT A MOUNTING (ST-SCWS FACTOY INSTALLD) 1.00 25.4 3.07 77.9 FONT VIW SID VIW ALTNAT A CABL NTY BACK/A VIW IN ± Dimensions: 0.01 mm ± 0.25 MOUNTING BACKT SUFAC MTG "FOOTPINT" DIMNSIONS 35 2.20 0.55 1.075 55.9 13.0 (X2) 27.3 1.380 35.1 2.00 BeamSafe, elay Output Version Unit Length Dims AC AC DC A B C 0.96 24.4 SLOTS FO T-NUTS 197.7 137.2 118.4 0.27 3.9 (X3) 7.79 5.40 4.66 C 0.27 1.28 L 6.9 DIA. DC 197.7 137.2 118.4 BOTTOM VIW 32.4 TOP VIW 9.44 239.6 7.79 197.7 7.79 7.05 178.9 5.40 137.2 5.40 6.31 160.1 4.66 118.4 4.66 ADJUSTABL MOUNTING BACKT BeamSafe, Solid-State Output Version, Tranmitter and This drawing is available in CAD format at www.sti.com/curtains/beamsafe/ 2.00 7.52 F. 4.40 191 111.8 3.66 93.0 MOUNTING HOLS (4) FO ALTNAT A MOUNTING (ST-SCWS FACTOY INSTALLD) 2.17 55.2 3.50 88.9 5.50 139.7 BeamSafe 6.62 168 F. BeamSafe ALTNAT A CABL NTY 1.00 25.4 FONT VIW SID VIW BACK/A VIW MOUNTING BACKT SUFAC MTG "FOOTPINT" DIMNSIONS 35 1.075 27.3 0.27 6.9 (X3) 1.275 32.4 1.875 47.6 C L 0.55 13.0 (X2) 1.38 35.1 2.00 Ø0.27 6.9 TOP VIW 0.81 20.5 SLOTS FO T-NUTS BOTTOM VIW ADJUSTABL MOUNTING BACKT IN ± Dimensions: 0.01 mm ± 0.25 C110

Ordering Model No. BS2X24 BS2XAC BS2XC24 BS224 BS2AC BS2C24 Description, 24 VDC, 85 to 250 VAC, 50/60 Hz, 24 VDC, Compact Size, 24 VDC, elay Output, 85 to 250 VAC, 50/60 Hz, elay Output, 24 VDC, Compact Size, Solid-state Output Accessories Description MI45-FG 4 inch mirror for use with MI45BKT-Front Glass MI45-SS 4 inch mirror for use with MI45BKT-Stainless Steel MI45BKT Bracket for mounting above mirrors at 45 angles for use in double bounce applications BSMK Bracket kit. Allows mounting of one BeamSafe transmitter and one BeamSafe receiver to STI mounting stands SBKT Adapter kit. Allows mounting of BSMK and MI45BKT components to extruded aluminum framing systems and other flat surfaces. MIS-04 4' stand for mounting mirrors and BeamSafe units MIS-06 6' stand for mounting mirrors and BeamSafe units QD-12 12', 12-conductor receiver cable, with quick-disconnect socket QDX-12 12', 4-conductor transmitter cable, with quick-disconnect socket BS2LA Laser Alignment Tool For information on STI safety light curtain accessories, see page C122 Safety Standards and Precautions The BeamSafe meets applicable OSHA, ANSI and IA standards and was designed in accordance with IC1496, DIN N 50100 and prn 954-1. Only use the BeamSafe on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use a BeamSafe on a full-revolution clutched press or machine. The BeamSafe is a single optical beam, not a curtain of light. Therefore it is not designed for use as a point-of-operation device. If one or more BeamSafe systems do not protect all access to the hazardous machine area, the unprotected access must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all appropriate laws, rules and regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. For the Latest Information Try Our Fax Back System at 1/916/431-6544 On the Internet: www.sti.com -mail: sales@sti.com C111

Custom Modifications Custom Modifications For Safety Light Curtains Custom Modifications STI offers a wide range of safety light curtains. The correct curtain for your application is probably in this engineering guide. If it isn't, contact our engineers to discuss your requirements. STI has an established reputation for creating custom modifications of standard products. Some examples are highlighted below. SD-safe Modification Versions of several STI safety light curtains are available for use in areas where it is important to dramatically reduce electrostatic discharge. The curtains have been tested to the standards of the OS/SD associations. Triboelectrification and static charge are well within the required limits. Consult STI for test results. High Temperature Fiber Optic Light Curtain STI can modify our standard MiniSafe MS4400 safety light curtain so that each individual beam is presented by a fiber optic cable. This allows the transmitter and receiver electronics to remain safely out of the high temperature area. Controller Quick-disconnect Certain applications call for to have double-ended quick-disconnect cables. This custom modification is available from STI. Quickdisconnect cables are available for transmitter, receiver, input power and relay output connections. MiniSafe Quick-disconnect Cables LD Indicators MiniSafe Film-safe Safety Light Curtains When used in a photographic film production facility, the infrared light normally emitted by will fog the film and spoil production. STI has designed with no visible indicators and "film friendly" infrared light. C130