Remote Controller Manual

Similar documents
CR193-RG70E2(2)BGEU

SYSCONTROL RM 52. SYSPLIT Type Remote controller user manual CR090 RG52A A

DVC/DVH 09/12/18/24 Series

SPLIT-TYPE ROOM AIR CONDITIONER

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM. Quick-Start Guide ON/OFF TEMP MODE SILENCE FP FAN SPEED SWING TIMER ON SWING TIMER OFF SLEEP

CONTENTS ,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons...

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons Auto operation...

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

REMOTE CONTROL MANUAL

Remote Control Operation Manual Split Type Air Conditioner

CR034-RG36F

AIR CONDITIONER REMOTE CONTROLLER MANUAL

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

Owner's Manual TABLE OF CONTENTS

USER MANUAL MIDEA FAIRWIND

Remote Control User Manual

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR137-RG51F

Owner's Manual TABLE OF CONTENTS

Portable Air Conditioner Instruction Manual

A IR CONDITIONE R REMOTE CONTROLLER ILLUSTRATION CR087-RG05F2EU

Buttons on remote controller

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR004-RG35/

REMOTE CONTROLLER CR057-RG51Q&J MANUAL

Owner s Manual TABLE OF CONTENTS

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

SERIES AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR054-RG51B

Owner s Manual TABLE OF CONTENTS

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Remote Control Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Operating Functions Temperature Parameters

SET TEMPERATURE( F) AUTO COOL DRY HEAT TEMP MODE SWING RESET LOCK LED DISPLAY

OWNER S & INSTRUCTION MANUAL

Portable Room Air Conditioner Remote Control for:

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

Remote Control Instructions

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

REMOTE CONTROLLER OWNER S MANUAL

REMOTE CONTROL MANUAL

High Wall Split Air Conditioners 53QHCT KHCT

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

CR103-RG57A3. REMOTE CONTROLLER ILLUSTRATION (Function selection)

2. Pictographs 2.1 Basic Operation

HMCI 125F-EH MOVABLE TYPE AIR CONDITIONER WITH OZONE-FRIENDLY R410A REFRIGERANT USER S MANUAL CAUTION:

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

Inverter Air Conditioner User Manual KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH

OWNER S MANUAL ENGLISH REMOTE CONTROLLER R05 YDS-R

Inverter Split System Room Air Conditioner User Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

SPLIT TYPE. Instruction manual

BTU Units WORKING PROGRAM MANUAL

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

Hi Wall Split Air Conditioners

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Remote Controller. <Open the front cover> <ARC452A4>

Slim Line Ceiling Concealed Ducted Split Systems

REMOTE CONTROLLER RG57

WORKING PROGRAM. Heating dehumidifying cooling T 27

INDOOR UNIT/OUTDOOR UNIT

Owner s Manual TABLE OF CONTENTS

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

USER'S OPERATING INSTRUCTIONS

USER MANUAL MPF. EasyCool Portable. MPF08CR71 MPF10CR71 MPF12CR71 MPF14CR71

REMOTE CONTROLLER KSWM units

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

SAT-3 Room Temperature Controller

INDOOR UNIT/OUTDOOR UNIT

Owner s Manual CS

Model: Slimline-RF. 1 Slimline Series

Owner s Manual TABLE OF CONTENTS

Remote Control Features & Functions

All about the. Use&Care. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

SALVADOR ESCODA S.A. OWNER S MANUAL. Provenza, planta Barcelona Tel Fax

ENGLISH REMOTE CONTROL MANUAL

User manual. Split Type Room Air Conditioner

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

MR-EH00_IB_04667A-01_Cover_EN.indd 오후 1:31:11

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

OWNER S MANUAL VMH 09/12/18/24

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

ETN1000/MIGA - Operating manual

Owner's Manual. Owner's Manual. Air Conditioners

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Split Air Conditioner

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

Owner s Manual TABLE OF CONTENTS

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Transcription:

Wall Mounted AIR CONDITIONER Remote Controller Manual KS Series KS09 KS12 KS18 KS24 KS28 + Mode Fan - J3498_Kaden_Controller Manual_280817.indd 1

J3498_Kaden_Controller Manual_280817.indd 2

Table of Contents 1. Remote controller specifications 4 2. Function buttons 4 3. Handling the remote controller 5 4. Remote LCD screen indicators 6 5. How to use the basic functions 7 6. How to use the advanced functions 13 Important note Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. Kaden Remote Controller Manual 3 J3498_Kaden_Controller Manual_280817.indd 3

1. Remote controller Specifications Model Rated Voltage Signal Receiving Range Environnt RG66A1/BGEF 3.0V (Dry batteries R03/LR03 2) 8m -5ºC~60ºC 2. Function buttons Before you begin using your new air conditioner, make sure to familiarise yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use The Basic/Advance Functions section of this manual. Turns the unit on or off MODE Scrolls through operation modes as follows: AUTO COOL DRY HEAT FAN ECO Starts and stops energy efficient feature. If held down for more than 2 seconds the sleep feature is activated. TIMER Set tir to turn unit on and off (see How to Use Basic Functions for instructions) SLEEP Saves energy during sleeping hours. Turns indoor unit s display on and off. FOLLOW ME Temperature sensing and room temperature display button. TURBO Enables unit to reach preset temperature in shortest possible ti. Mode Fan OURITE Sets and activates your favourite pre-settings. FAN Selects fan speeds in the following order: AUTO LOW MED HIGH NOTE: Holding this button down for 2 seconds will activate Silent feature. TEMP Increases temperate in 1ºC incrents. Max. temperature is 30ºC TEMP Decreases temperate in 1ºC incrents. Min. temperature is 17ºC SWING Starts and stops horizontal louver movent. SWING Starts and stops vertical louver movent. SELF CLEAN Starts and stops the unit self feature. 4 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 4

3. Handling the remote controller Not sure what a function does? Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner. Inserting and replacing batteries Your air conditioning unit cos with two AAA batteries. Put the batteries in the remote control before use: 1. Remove the back cover from the remote control, exposing the battery compartnt. 2. Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartnt. Tips for using remote control The remote control must be used within 8 ters of the unit. The unit will beep when remote signal is received. Curtains, other materials and direct sunlight can interfere with the infrared signal receiver. Remove batteries if the remote control will not be used more than 2 months. 3. Install the back cover. Installing remote control holder The remote controller can be attached to a wall or stand by using a remote controller holder. 1. Before installing the remote controller, check that the air conditioner receives the signals properly. Remove the back cover to install batteries. 2. Install the holder with two screws. 3. Put the remote controller in the holder. Battery notes For optimum product performance: Do not mix old and new batteries, or batteries of different types. Do not leave batteries in the remote control if you don t plan on using the device for more than 2 months. Put the remote controller in the holder. Battery disposal Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries. Kaden Remote Controller Manual 5 J3498_Kaden_Controller Manual_280817.indd 5

4. Remote LCD screen indicators Information is displayed when the remote controller is powered up. display Appears when the unit is turned on, and disappears when the unit is turned off. Transmission indicator Lights up when remote sends signal to indoor unit MODE display Displays the current mode, including: TIMER ON display ( ) Displays when TIMER ON is set TIMER OFF display ( ) Displays when TIMER OFF is set Displays when ECO feature is activated. Battery display Low battery detection Temperature/ display Displays the set temperature by default, or tir setting when using TIMER function Temperature range: 17 30ºC Ti setting range: 0-24 hours This display is blank when operating in FAN mode. Fan speed display Displays selected fan speed: Silent feature display feature display LOCK feature display mode display Low speed Medium speed High speed AUTO Auto fan speed This fan speed can not be adjusted in AUTO or DRY mode 6 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 6

5. How to use the basic functions AUTO operation In AUTO mode, the unit will automatically select the COOL, FAN, HEAT or DRY mode based on the set temperature. 1. Press the MODE button to select Auto mode. 2. Set your desired temperature using the Temp + or Temp button. 3. Press the button to start the unit. 3 1 Mode Fan 2 FAN SPEED can t be set in Auto mode. COOL operation 1. Press the MODE button to select COOL mode. 2. Set your desired temperature using the Temp + or Temp button. 3. Press the FAN button to select the fan speed. 4. Press the button to start the unit. Setting temperature The operating temperature range for units is 17-30ºC. You can increase or decrease the set temperature in 1ºC incrents. 4 1 Mode Fan 2 3 Kaden Remote Controller Manual 7 J3498_Kaden_Controller Manual_280817.indd 7

DRY operation (dehumidifying) 1. Press the MODE button to select DRY mode. 2. Set your desired temperature using the Temp + or Temp button. 3. Press the button to start the unit. FAN SPEED can t be changed in DRY mode. 1 Mode Fan 2 3 FAN operation 1. Press the MODE button to select FAN mode. 2. Press the FAN button to select the fan speed. 3. Press the button to start the unit. You can t set temperature in FAN mode. As a result, your remote control s LCD screen will not display temperature. Mode Fan 1 2 3 8 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 8

HEAT operation 1. Press the MODE button to select heat mode. 2. Set your desired temperature using the Temp + or Temp button. 3. Press the FAN button to select the fan speed. 4. Press the button to start the unit. As outdoor temperature drops, the performance of your unit s HEAT function may be affected. In such instances, we recomnd using this air conditioner in conjunction with other heating appliance. 1 4 Mode Fan 2 3 Kaden Remote Controller Manual 9 J3498_Kaden_Controller Manual_280817.indd 9

SHORT CUT MODE TIMER ON TEMP Setting the TIMER function Your air conditioning unit has two tir-related functions: TIMER ON sets the amount of ti after which the unit will automatically turn on. TIMER OFF sets the amount of ti after which the unit will automatically turn off. TIMER ON function The TIMER ON function allows you to set a period of ti after which the unit will automatically turn on, such as when you co ho from work. 1. Press the button, the on indicator displays and flashes. By default, the last ti period that you set and an h (indicating hours) will appear on the display. : This number indicates the amount of ti after the current ti that you want the unit to turn on. For example, if you set TIMER ON for 2.5 hours, 2.5h will appear on the screen, and the unit will turn on after 2.5 hours. 2. Press the Temp + or Temp button repeatedly to set the ti when you want the unit to turn on. 3. Wait 3 seconds, then the TIMER ON function will be activated. The digital display on your remote control will then return to the temperature display. The indicator remains on and this function is activated. TIMER OFF function The TIMER off function allows you to set a period of ti after which the unit will automatically turn off, such as when you wake up. 1. Press the button, the off indicator displays and flashes. By default, the last ti period that you set and an h (indicating hours) will appear on the display. : This number indicates the amount of ti after the current ti that you want the unit to turn off. For example, if you set TIMER OFF for 5 hours, 5.0h will appear on the screen, and the unit will turn off after 5 hours. 2. Press the Temp + or Temp button repeatedly to set the ti when you want the unit to turn off. 3. Wait 3 seconds, then the TIMER OFF function will be activated. The digital display on your remote control will then return to the temperature display. The indicator remains on and this function is activated. 1 2 or x10 1 2 x5 3 4 3sec or 3 4 3sec Example: Setting unit to turn off after 5 hours SHORT CUT MODE TIMER ON TEMP Example: Setting unit to turn on after 2.5 hours When setting the TIMER ON or TIMER OFF functions, up to 10 hours, the ti will increase in 30 minute incrents with each press. After 10 hours and up to 24, it will increase in 1 hour incrents. The tir will revert to zero after 24 hours. You can turn off either function by setting its tir to 0.0h. 10 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 10

MODE CUT MODE TEMP CUT Setting both TIMER ON and TIMER OFF at the sa ti Keep in mind that the ti periods you set for both functions refer to hours after the current ti. For example, say that the current ti is 1:00 PM, and you want the unit to turn on automatically at 7:00 PM. You want it to operate for 2 hours, then automatically turn off at 9:00 PM. Do the following: 1 2 x12 3 4 3 sec or SHORT TEMP TIMER ON 5 6 x16 7 8 3 sec or SHORT TIMER ON Kaden Remote Controller Manual 11 J3498_Kaden_Controller Manual_280817.indd 11

Example: Setting the unit to turn on after 6 hours, operate for 2 hours, then turn off (see figure below) Your remote display is set to turn ON 6 hours from current ti is set to turn OFF 8 hours from current ti starts Unit turns ON Unit turns OFF Current ti 1PM 2PM 3PM 4PM 5PM 6PM 7PM 8PM 9PM 6 hours later 8 hours later 12 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 12

6. How To Use The Advanced Functions ECO function This function is only available under COOL mode. ECO operation When the ECO feature is activated, the air conditioner will operate automatically at 24ºC. The fan speed is Auto. SELF CLEAN function Airborne bacteria can grow in the moisture that condenses around heat exchanger in the unit. With regular use, most of this moisture is evaporated from the unit. When the self feature is activated, your unit will itself automatically. After ing, unit will turn off automatically. You can use self feature as often as you like. You can only activate this function in COOL or DRY mode Pressing the button, modifying the mode or adjusting the set temperature to less than 24ºC will stop ECO operation. Under ECO operation, the set temperature should be 24ºC or higher. It may result in insufficient cooling if you feel unconformable, just adjust the temperature to stop it. SLEEP function The SLEEP function is used to decrease energy use while you sleep (and don t need the sa temperature settings to stay comfortable). This function can only be activated via remote control. For detail, see sleep operation in OWNER S MANUAL. The SLEEP function is not available in FAN or DRY mode. TURBO function The TURBO function makes the unit work extra hard to reach your present temperature in the shortest amount of ti possible. When you select TURBO feature in COOL/HEAT mode, the unit will blow cool/hot air with strongest wind setting to jump-start the cooling/heating process. Kaden Remote Controller Manual 13 J3498_Kaden_Controller Manual_280817.indd 13

Hold down Fan button for 2 seconds to activate silent function Mode Fan Mode Fan Hold together for one second to activate LOCK function LOCK function Press button and self button simultaneously for one second to lock or unlock the keyboard. FOLLOW ME function The follow function enables the remote control to asure the temperature at its current location and send this signal to the air conditioner every 3 minute interval. When using AUTO, COOL, or HEAT modes, asuring ambient temperature from the remote control (instead of from the indoor unit itself) will enable the air conditioner to optimise the temperature around you and ensure maximum comfort. SWING function Swing Button Used to stop or start vertical louver movent and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the vertical louver auto swing feature is activated. Swing Button Used to stop or start horizontal louver movent or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If keep pushing more than 2 seconds, the louver will swing up and down automatically. 14 Kaden Remote Controller Manual J3498_Kaden_Controller Manual_280817.indd 14

Silent function Hold down Fan button for 2 seconds to activate /cancel Silent mode. Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity. Favourite Function Used to restore the current settings or resu previous settings. Push this button when remote controller is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated). If pushing more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated). Kaden Remote Controller Manual 15 J3498_Kaden_Controller Manual_280817.indd 15

J3498_Kaden_Controller Manual_280817.indd 16