Powerblanket Thermostatic Controller (A421)

Similar documents
Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

CHR Inc. Custom Heaters & Research Digital Heating Jacket Instruction Manual

Quick Tips Electronic Temperature Controllers (ETC)

Digital Pail Heater Instruction Manual

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Operation and Maintenance Manual OM 897-3

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

K00364 Electronic Bin Thermostat

User s Manual

Owner s Manual RD432-0 Chemical Controller

108A OTP1800. Grid Support. General Description

MULTI-STAGE CHILLER CONTROL

User Guide. Stainless Steel Filter Housing Heater

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Refrigerated air dryers

SC Installation, Operation & Application Guide

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

M790 ph/orp Controller. Owner s Manual

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Introduction. OM-THA2

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

DNC-PS700-A10 Differential Pressure Control Meter. Operation and Installation Manual

Installation Guide: PowerAire Quad

Dryer Controller M720

MODEL 721 ELECTRICAL DATA: FEATURES: ACCESSORIES: DIMENSIONS: SHIPPING INFORMATION: CONVECTION OVEN 1/2 SIZE PAN

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

User Manual. Dryer Controller M720

ST Wiring diagram. Product description. Four-stage controller. Order number

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Programmable Thermostat

Wiring Instructions. High-Capacity Steam Humidifiers

Digital Marine Exhaust Temperature Alarm

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

EasyTronic III MANUAL SERVICE

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Oakton TEMP 9500 Advanced Multiparameter Controller

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

CG Series Digital Temperature Controller OPERATIONS MANUAL

Autofire Express Ramp/Hold Controller Instruction Guide

T-32-TS Touchscreen Thermostat. Installation Manual

M770 ph Controller Owner s Manual

Owner s Manual MODEL 8555

SC Installation, Operation & Application Guide

BV382510V 1.0 L gooseneck variable electrical kettle

CT500 Electronic Thermostat

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

1F90W-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat WHITE-RODGERS

SC Installation, Operation & Application Guide

Quality Refrigeration OWNER S MANUAL

215-HVR. Benchmark 215-HVR. 120 VAC, Single Phase, 20 amp

CommStat 4 Controller

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

HEAT HEAT HEAT COOL COOL

CAREL IR33+ CONTROLLER

flexibility programmed settings.

TEMPERATURE CONTROLLER (STANDARD MODEL)

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

QD-ENG-68 Controller for Thermoelectric Thermal Management

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

REV: 000. Radiant Flash Service Manual

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Hoshizaki America, Inc.

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

Installation and Operation Manual

OPERATION MANUAL. CLASSIC PLUS 14 and CLASSIC PLUS 26 ~ SECTION EN FRANÇAIS

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

User Guide. Uno sous vide controller

Note To The User: This product has updated features not yet mentioned in the product manual.

RCS Residential Control Systems Inc.

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

1F90-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 5 Day/2 Day Electronic Digital Thermostat

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

Operator: Save these instructions for future use!

Owner s Manual. Part Number 33CSCPACHP-01

Model: Available in: Sapphire Black and Glacier White. 1 Series

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

1F91W-71 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! Multi-stage Electronic Digital Thermostat

OFFICE PRO 36 and OFFICE PRO 60 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

Digital Thermostat Models: VS30W and VS30B

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

OWNER S MANUAL Venstar Inc. 08/07

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

ECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)

Three Ventilation Stage Control. TVS user manual

Installer Guide. WARNING Important Safety Information. 1 Specifications

Demand Duo Principle of Operation:

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Transcription:

Powerblanket Thermostatic Controller (A421) PAGE 1

Powerblanket Thermostatic Controller Instructions Powerblanket 3130 South 1030 West, Ste. 1 Salt Lake City, UT 84119 PAGE 2

POWERBLANKET THERMOSTATIC CONTROLLER INSTRUCTIONS Thank you for purchasing a Powerblanket GHT2002J Thermostatic Controller. Please read and understand these instructions before continuing. Please retain these instructions and the A421 Series instruction set (Johnson Controls use A421AEC within) for future reference. GHT2002J Thermostatic Controller. From left to right, please note the input power supply cord (~6 long) with plug, gray temperature sensor lead (~6 long) with steel encased temperature sensor/probe at the end, hanger kit installed and the output 2 long cord with connector (a k a receptacle). The GHT2002J controller plugs into your GFCI protected power supply (wall, etc.). The controller will power up when you plug in its power supply cord. Your Powerblanket heating blanket plugs into the output receptacle cord of the GHT2002J. The controller turns on and off the power to the receptacle depending upon the temperature of the probe/sensor versus the OFF and ON temperatures you have programmed into the controller (more information below). PAGE 3

VERY IMPORTANT: Place the temperature sensor between the heating blanket and that which is to be heated, for example, your barrel or tote. CAUTION Improper probe placement can result in unsatisfactory performance and/or damage to your vessel, product or heating blanket. CAUTION Do not submerge the temperature sensor - it is not waterproof. PAGE 4

Here is an example application where the system is completely setup. Please note: i) The controller is plugged into an approved GFCI circuit protector which is plugged into an approved extension cord (not shown). ii) The temperature sensor is placed between the heated wrap and the outside of the poly barrel. iii) The heated wrap is plugged into the output receptacle of the controller. iv) The controller is hanging from the top strap of the heated wrap. v) The system is positioned on a solid woodtopped pallet to reduce heat loss out of the bottom of the barrel. The GHT2002J controller is programmed at the Powerblanket factory to be in its heating mode and to turn the heating blanket OFF at the OFF set temperature and turn it back ON when the temperature of the probe/sensor reaches the ON set temperature. Unless in the programming mode, the display shows the current temperature of the probe. It is important to note that the temperature of the contents in your vessel will lag this displayed temperature. This amount may vary depending on your application. As the contents in your vessel approach the desired temperature this difference will be much less. The green light will glow when there is power to the output receptacle and go off when the power is not connected to the receptacle. There should be an audible click as the controller turns the power to the output receptacle on or off. (You are hearing the internal relay operate.) To program the thermostatic controller to new OFF and ON temperatures, press MENU. The controller is now in programming mode. With OFF flashing, if you push MENU again, it will start flashing the current OFF temperature. Use the UP or DOWN arrow buttons to increase or decrease the temperature set point, one degree per button push. When the correct OFF temperature is flashing on the display, press MENU again. This scrolls the controller to the ON variable. Press MENU again to access the ON variable. Use the UP or DOWN arrow buttons to increase or decrease the temperature set point, one degree per button push. Press MENU again to PAGE 5

exit the ON variable. Press the UP and DOWN arrows simultaneously again to exit programming mode. The display will revert to a steady display of the present temperature of the probe/sensor. CAUTION: Do not program the controller to OFF > 170 F (77 C) as this may damage the heating blanket, your vessel and/or your product. A Quick Look at Programmable Control Functions: OFF, Relay Off Temperature, possible values from -40F to +212F, this is the temperature at which the controller will turn off the heating blanket. Please see CAUTION above. On, Relay On Temperature, the temperature at which you want the blanket to start heating again. Possible values from -40F to +212F ASd, Anti-Short Cycle Delay, Powerblanket presets this to zero minutes. It is the time you want the controller to wait BEFORE it does anything after power is applied to the controller (after you plug it in or after the power comes back on in the case of a temporary power outage). ASd is useful when running, for example, a cooling pump where a quick power outage or temperature cycle will stall the compressor and it won t safely restart until the pressure has equalized in the system which can take several minutes. For heating blankets, there is no reason to wait to restart the system. SF, Sensor Failure Operation, Powerblanket presets this to zero which has the effect of turning off the heating blanket in the rare case of sensor failure. Should you decide you want the blanket to run full power without temperature control if the sensor malfunctions, which Powerblanket does not recommend, set it to one. F or C, Temperature Units, the units can be switched from Fahrenheit to Celsius or back by holding the UP and DOWN arrows simultaneously for 5 seconds. UN will start flashing on the screen. Press MENU to access this variable, then use the UP and DOWN arrows to select F or C. Press the UP and DOWN arrows again simultaneously to return to the main functions of the unit. To change the values of any of these variables (except F or C ), press MENU to enter programming mode, then use the UP and DOWN arrows to scroll to the function you wish to program. Once you reach the desired function, press MENU again to adjust that variable. The present value of each function will be shown. Use the arrow buttons to select the new value then press MENU again to make that the new value in memory. If the controller is left idle in programming mode for 30 seconds, the controller will exit the programming mode and the value will not be changed. Other Controller Information: NEMA/UL 4X Watertight enclosure. 120VAC GHT2002J (A421AEC), 15 Amps max for heating blankets. 240VAC GHT2002J-240V (A421AEC), 10 Amps max for heating blankets. More information via A421 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures also included with the GHT2002J controller. PAGE 6